RainMaster FM Remote Control System Owners

Survival, Water, Medical Field Manuals

Military Manuals

Document text

FM Remote Control System 


User Manual 











A 
qu 
= 
O 
i 
O 





Models: 
PROMAX 
PROMAX-UA 





aan MASTER 


Document No. 500055 Rev. E 





Rain Master Irrigation Systems Pro Max User's Manual 





Table of Contents 

L.0:Introducton... «naar 1 
lil (Prodfax Peatutes eu pectin cae iuo de lare deti lo A E 2 
1.2 Ranges and Method of Transmission o Actes Seid setae quie al 3 
1:3: "Licensing Information santa ie goes beoe ti i plac n oed Bra osea IV te Foot P Dvd Gens 4 
2.0 Model Pro Max Remote Control System (Rain Master Only)...................... 6 
2.] Using the Receiver with a Rain Master Controller ....................... eene 7 
2.1.1 Connecting the Receiver to a Rain Master Controller ........................... eee 7 
2.1.2 Disconnecting the Receiver from a Rain Master Controller........................... esses 8 
2.2 Permanent Mount Pro Max Recerversc st uscirono 8 
23: E O kene e E E A E ESE a aa 11 
2.3.1 Evolution DX2 Keystroke Operations... eri 14 
3.0 Model Pro Max-UA Remote Control System (Universal) ........................... 15 
3.] Using the Pro Max-UA Universal Adapter with a Non Rain Master Controller ............. 16 
3.2. Installing the Pro Max-UA System... urinaria 16 
3.3 Temporary Connector Toa LL 19 
3.4 Disconnecting the Pro Max-UA from a Non-Rain Master Controller ............................. 19 
3.5 Non-Rain Master Controllers Lacking 24 Volts AC.............. i 19 
3.6  Disconnecting the Pro Max-UA from a Non-Rain Master Controller ............................. 20 
3.7 Non-Rain Master Controllers Lacking 24 Volts AC................... eee 20 
3.9. Permanent Wire Connections: 2.03... lei A Raise A d eus 20 
39° ‘Keystroke Opera sida 21 
4:0Détalled:Operationi.:. lla iva 22 
ÆT Remote Operativa rana 22 
4:2. -Stations On and Oia stes Estados 22 
Z3- Auto Dp and AO ORO nó 23 
Qu Omand ORO ia 23 
4.5: «Master V.alve/PUump: Reysan ir sacs e UNO a 23 
4.6 "Controller Access Code... uinci rer eee ipee de iii 24 
AT Add SUA OMS eec secedere deuda eae ele dde. 25 
Z LU. AOS Oneto ei 25 
4.7.2 Add Stations — Auto Up and Auto down Keys ........... sse 25 
4:75: -Add Stations~ OT 25 
48 "Program Func iter lla du tesa dise eed oia ui cli Si lia lie 26 
4.5.4 Program =O Key tl Rel liebe 26 
45.2. Program = AU up Key «des costi e Hebel tried loto as 26 
4.8.3 Program - Sensor Switches irritare 26 
4.0, Minutes PUHCDODS nocte A ir sali pa ciali a e ie Sees 27 
4-10 Besper Opera On ise ital pirlo iaia une ali ni rina lirica LL 27 
4.10.1. Power on Beeper Operation specs rari 27 
4.10.2 Universal Adapter Over-Current Detection Beeper........................... i 28 
4.11 Transmitter Battery Replacement. eere ele die dera A AA A 28 


Page i 


Pro Max User's Manual Rain Master Irrigation Systems 





5.0 Checking Out Electrical Problems................................- seno neeeee seen neereeeeneneneceso 30 
5.] Field Wiring Shorts, the Receiver, and Rain Master Controllers....................... 30 
5.2 Field Wiring Shorts, the Receiver, and Non Rain Master Controllers............................. 30 
5.3 -A Note about SOC DOLUS ene aa 30 

0:0Eroubleshootnp....... lalla iii diia. 31 

7.0 Pro Max Speciicatiolis ao cación 33 
TA -Pro Max Transredes 33 
12. ProMax ReoelVer,. aucibus das ció 33 
des” Pro Max Universal Adapters Sirinka iae es a E Ta a ei 33 
TA Pró Max Camry Me Case h arsen o mass E E EA iaia 33 

8:0 Pro Max Series Parts. EdSt iieri nari 34 

Rain Master Limited Warranty... «iii 35 


Page ii 


Rain Master Irrigation Systems Pro Max User's Manual 





Table of Figures 
Figure 1: Pro Max FM Remote Control System aa cioe Probi pte ies 1 
Figure:2 Complete Pro Max yt reti idoli sio 6 
Figure 3: Pro Max Receiver to Rain Master Controller..................... eene 8 
Figure 4: Permanent Mount Pro Max Recelver. sai abet esta lisi teras 9 
Figure 5: Pro Max Transmitter (PM-XMTR) occitano 10 
Figure 6: Complete Pro Max-U Ac System. siria doni ossia reda dst s 15 
Figure 7: Relay (such as Rain Master RLY iii bade la eee ia 17 
Figure 8: Pro Max-UA Installation to a Non-Rain Master Controller................................ ss 19 
Figure 9: Non-Rain Master Controller 24 Volts AC .............. sese 20 
Figure 10: Pro Max-UA. Permanent Connection... recall 21 
Etgure- 11: Battery Replacement: uito iba 28 
Notice: 


Information furnished by Rain Master Irrigation Systems Inc. is believed to be accurate and 
reliable. However, Rain Master shall not be liable for errors contained herein or for incidental 
or consequential damages in connection with the furnishing, performance or use of this 
material. 


The information contained in this document is subject to change without notice. 


Page iii 


Rain Master Irrigation Systems Pro Max User's Manual 





Pro Max 


Congratulations... you have chosen one of the ultimate weapons to use in keeping maintenance 
costs down and satisfaction high — the Rain Master Pro Max Remote Control System. Rain 
Master engineer’ s take great pride in all their work, but they are especially proud of Pro Max. 
You'll find it packed with features you've been looking for and it's extremely easy for everyone 
to use. Pro Max has been designed to give you years of dependable service. 


To take full advantage of all the ways Pro Max can help you do your job more efficiently and 
economically, please take a few minutes and read your User Manual. It won't be long before 
your best friend in the field is Pro Max. 





Figure 1: Pro Max FM Remote Control System 


1.0 Introduction 


The Pro Max Remote Control System is designed to save valuable time and energy, which would 
have been spent walking back and forth between the controller and the irrigation field zone 


Page 1 


Pro Max User's Manual Rain Master Irrigation Systems 





location. It makes light work of system checkouts and service work, providing field personnel 
with complete control over the irrigation controller. 


Controllers may be operated remotely from watering zone sites allowing immediate evaluation of 
the irrigation configuration and performance. Using the hand-held battery operated Pro Max 
Transmitter from a remote zone location; the operator may turn ON a single station or any 
number of stations with the push of a few simple keys. 


An access code feature allows independent control of multiple Pro Max receivers permanently 
installed in up to 999 controllers. In addition to the maintenance features, the Pro Max system 
provides specialized irrigation functions, which are described in Section 1.1. 


The Pro Max remote control system is composed of two model numbers: 


Model No. Description 
Pro Max Used with Rain Master only controllers. (See Section 2.0) 
Pro Max-UA Used with any manufacturers’ 24-volt AC controller. (See 
Section 3.0) 
1.1 Pro Max Features 
Simplicity 
e The industries easiest remote to use. 
e Fits in shirt or pants pocket or can be attached using the convenient belt clip. 
e Large dedicated feature keys allow most functions to be performed with a single key 
operation. 
e Auto-up and auto-down station operation. 
Flexibility 


Page 2 


Can be used with any manufacturers’ 24-volt AC controller (Model Pro Max-UA). 
Independent control of the master valve and/or pump. 

Single or multi-station capabilities for testing system hydraulics. 

Timed station operation selectable from 1 to 60 minutes. 

Control up to 999 individual Pro Max receivers from a single Pro Max transmitter. 


Ability to turn a program ON or OFF (when used with RME Sentar, RME Hawk, RME 
Eagle, or Evolution DX2 controllers). 


Small and compact Pro Max receiver design facilities permanent internal controller 
mount. 


Compatibility with Rain Master RTS/RRAD remote. 


Rain Master Irrigation Systems Pro Max User's Manual 





Intelligence 


e Detects and provides an audible alert against field wiring short circuits (Model Pro Max- 
UA). 


e No more tripped circuit breakers or blown fuses during installation checkout. 
e Receiver has built-in safety default to automatically turn station OFF after 60 minutes. 


e Audible Pro Max transmitter and Pro Max receiver tones verify proper Pro Max remote 
control operations at all times. 


e High tech power saver circuitry means no more battery recharging required (no down 
time). 


e Transmitter has a single replacement lithium battery that can be purchased locally and 
field replaced. The battery will last an entire season, under normal conditions. 


e Audible low battery alert. 
e No fuses required. 


Durability 


e Tough, rugged all metal construction with shock absorbing rubber bumpers. 


e Hard cover case for carefree transportation. 


Reliability 
e Utilizes three mechanisms to insure reliable, interference-free communications. 
- Digital filters 
- Factory set coding 
- VHF FM communications 


1.2 Ranges and Method of Transmission 


It is not possible to exactly predict the distance over which the Pro Max system will perform. 
Several factors may affect the distance and reliability of any radio transmission: 


e Frequency used e Transmission Power 

e Terrain e Antenna placement 

e Building Structures e Weather conditions 

e On channel interference e Atmospheric disturbances 

e Antenna types e Mode of operation (AM, FM, etc.) 


Your Pro Max system has been designed to operate at distances up to one mile. Under ideal open 
field conditions, it can readily operate up to 5 miles. 


When attempting to use Pro Max over extended distances, it is important to ensure that the 
receiving antenna is properly located. If possible, avoid Pro Max receiver antenna locations, 


Page 3 


Pro Max User's Manual Rain Master Irrigation Systems 





which are indoors, especially basements, or structures, which are concrete and steel. It may be 
possible to remotely locate an external antenna whenever poor Pro Max receiver locations exist. 
Call Rain Master Technical support for assistance, telephone (805) 527-4498. Moving the Pro 
Max transmitter to a more favorable location or usage of optional high gain antennas on both the 
Pro Max transmitter and Pro Max receiver may improve operations. 


The Pro Max system utilizes VHF/FM communications and the Pro Max receiver/Pro Max 
transmitter pair is factory encoded to insure that other services including other Rain Master 
remotes do not interfere or false trigger the Pro Max receiver. Digital filtering further enhances 
operation in interference prone environments. FM transmission is employed for its inherent 
quality and immunity to atmospheric, static, and electrical interference which are commonly 
found in AM types of equipment such as citizen’s band radio, garage door openers, etc. Usage of 
FM transmissions also insures that the stronger signal prevails (capture ratio), meaning that all 
received signals, which are weaker than the Pro Max transmission, are completely overridden. 
Note: Antennas are not just a piece of wire; they are cut for a precise frequency of 
operation in order to ensure optimal performance. When using antennas with the 
Pro Max system, only utilize Rain Master specified parts, which are available 
through your authorized Rain Master distributor. 


1.3 Licensing Information 


Your Rain Master Pro Max radio operates on FM radio communication frequencies and is 
subject to the rules and regulations of the local communications governing agencies. These 
agencies may require that all operators using private land mobile or general mobile radio 
frequencies obtain a radio license before operating their equipment. The operator receives a 
license for use of the radio equipment under a specific eligibility and ON a particular frequency 
or set of frequencies. To determine eligibility for use of private land mobile service frequencies, 
contact your local communications governing agency. This agency can supply information 
required to properly obtain and complete the license application form. 
For U.S. License Applications, contact: 

FCC Forms Distribution Center 

1 (800) 418-3676 

Request form 600 and all schedules and instructions. 

For license questions call the FCC at 1 (888) 225-5322. 


The following are addresses of communications agencies in North America: 


United States Canada 

Federal Communications Commission Department of Communications 
1270 Fairfield Road 1241 Clyde Avenue 
Gettysburg, PA 17325-7245 Ottawa, Ontario 
1-800-322-1117 K2C 143 


Page 4 


Rain Master Irrigation Systems Pro Max User's Manual 





Mexico 


Sectretaria De Comunicaciones 

Y Transportes 

Direccion General de Politicas Y Normas de Comunicaciones 
Av. Eugenia No. 197-50. Piso 

Mexico, D.F. 06700 


Page 5 


Pro Max User's Manual 


Rain Master Irrigation Systems 





2.0 Model Pro Max Remote Control System (Rain Master Only) 


The Pro Max receiver is designed to connect directly to any Rain Master controller by plugging 
the 9-pin connector from the Pro Max receiver into the front panel remote control jack found ON 


Rain Master controllers. 





Figure 2: Complete Pro Max System 






































Pro Max Parts List 

Part No. Ref. Description 
PM-XMTR 1 | Pro Max Remote radio transmitter 
PM-RCVR 2 | Pro Max Remote receiver 
PM-SER99 3 | 36” remote cable 
500055 4 | Pro Max User's manual 
PM-CASE 5 | Pro Max carrying case 
PM-ANT-XMTR | 6 | Antenna, BNC 
PM-ANT-RCVR 7 Antenna, hinged, BNC 





Page 6 





Rain Master Irrigation Systems Pro Max User's Manual 





2.1 Using the Receiver with a Rain Master Controller 


One of the unique and patented features of Rain Master Controllers is the built-in capability for 
remote control. Making the connections between the hand held remote transmitter and the Pro 
Max receiver, which is attached to the controller, takes just a few seconds. 


2.1.1 Connecting the Receiver to a Rain Master Controller 


Connecting the Pro Max receiver to the controller is a very simple operation. The following 
procedure steps are all that is required. Please refer to Figure 3: Pro Max Receiver to Rain 
Master Controller. 


Step 1 


Step 2 


Step 3 


Step 4 


Make sure the controller is in the Automatic mode press the controllers” QUIT 
key. 

Make sure the controller's Rain Switch, if so equipped, is in the automatic 
watering position. 


Place the Pro Max receiver on top of the controller with the antenna pointing 
straight up. Do not allow the antenna to touch any metal objects or wire. 


Connect the female end of the PM-SER99 cable to the Pro Max receiver and 
secure with lock screws. Hands tighten only. Connect the other end of the cable 
to the remote control receptacle on the front panel of the controller (it is keyed 
to fit only in one way). 


The controller's display will either go blank or indicate that the remote is active. 
The Pro Max receiver will beep to indicate that it is ready for use. 


Note: NEVER operate the Pro Max transmitter without the 
CORRECT antenna properly installed. 


Page 7 


Pro Max User's Manual Rain Master Irrigation Systems 

















Upon Receiver Connection 
Beep Response Description 
1 Beep (1/2 sec) Ready 
Multi-Pro Max receiver mode: 
2 Beeps e Requires corresponding access code to 


enable Pro Max receiver operation. 





Failed internal diagnostic tests. Contact Rain 


PECES Master. 




















Figure 3: Pro Max Receiver to Rain Master Controller 


2.1.2 Disconnecting the Receiver from a Rain Master Controller 
To disconnect the Pro Max Pro Max receiver, follow the procedure below. 

Step 1 Disconnect the Pro Max receiver's plug from the controller’s front panel by 
grasping the plug housing, not the cable, and pulling straight out. The controller 
display should now return to the automatic screen display. 

22 Permanent Mount Pro Max Receiver 
Pro Max Receivers may be permanently installed into any Rain Master controller. 


Two items are required for permanent controller installation: 


Page 8 


Rain Master Irrigation Systems Pro Max User's Manual 





1. Part No. JACK-IRC 


e Factory installed permanent interface. 


e Factory programmed Pro Max receiver with a programmed access code (1-999). Access 
codes are required whenever one Pro Max transmitter controls multiple Pro Max Pro 
Max receivers. 


2. Part No. PMRKIT 
e Permanently mounted Pro Max receiver 
e Antenna Pro Max-ANT 
e All interconnecting cables and hardware 


Note: Operation of a permanent mount Pro Max receiver requires usage of the 
ACCESS CODE feature key. Refer to section 4.6. 











Figure 4: Permanent Mount Pro Max Receiver 


Page 9 


Pro Max User's Manual Rain Master Irrigation Systems 














Figure 5: Pro Max Transmitter (PM-XMTR) 


Page 10 


Rain Master Irrigation Systems Pro Max User's Manual 





2.3 Keystroke Operation 
The Pro Max keyboard layout is shown in Figure 5. 





Basic Operation 





Function Keystrokes 








Increment to next Station Q 





Decrement to next Station 
DOWN 





Turn On Station 12 EB 





Turn Off Station 12 Q 





Turn On Master Valve/Pump 





M 
PUMP 








Turn Off Master Valve/Pump 








26 
ES 4 





Note: Any prior operating station will turn OFF when an Auto-Up, Auto-Down, Station 
On, Station Off key is pressed. 





Timed Station Operation (Minutes) * 


Function Keystrokes 








Turn On Station 1 for 5 minutes EB ra MINUTES 








Increments To Next Station and Re- 
start Timer 











Decrement To Next Station and Re- TE 
start Timer DOWN 





09 





Page 11 








Pro Max User's Manual Rain Master Irrigation Systems 








Multiple Stations On (Add Stations) 





Function Keystrokes 








Turn On Multiple Stations 

1, 2, 6, 

Turn Station 6 OFF r3 
(Station 1, 2 remain) 


Turn All Stations OFF 











Turn All Stations OFF 


and Increment the stations 
selected From Last 


Station 








* When this function is used with the Rain Master RME Sentar, RME Hawk, or Evolution DX2 
controllers, the controller will automatically turn ON the appropriate Master Valve or Pump. 





Program Operation (Program) ** 








Function Keystrokes 











Turn Program 5 On PROGRAM 5) 





Increment to Next Station in 
Program 





Turn Program 5 Off 











Page 12 


Rain Master Irrigation Systems Pro Max User's Manual 








Using Multiple Receivers (Access Code) 





Function Keystrokes 








Enable Pro Max Receiver #15. 
Controller now accepts all 
remote keys. 





ACCESS 
CODE 








Disable Pro Max Receiver #15 





‘ors 
CODE 











i , ACCESS 
Disable All Pro Max Receivers CODE Q 











** This function only works with the following Rain Master controllers: RME Sentar, Hawk, 
Eagle, Evolution DX2 controllers. Only one program can be operated at a time. 


Page 13 





Pro Max User's Manual Rain Master Irrigation Systems 





2.3.1 Evolution DX2 Keystroke Operations 


The following operations are only available when using the Pro Max Remote Control System 
with the Rain Master Evolution DX2 Controller: 





Evolution DX2 Master Valve 


























PUMP 





Function Keystrokes 

MV 

Turn On Master Valve One PUMP EB > 
MV 

Turn ON Master Valve Two PUMP EB > 

Turn On Normally Open Master 

Valve MV 

(Closes the normally open PUMP 

valve) 

Turn Off Normally Open 

Master Valve MV ES 

(Valve returns to normally open PUMP 

state) 

Turn On Pump > 





Page 14 





Rain Master Irrigation Systems 


Pro Max User's Manual 





3.0 Model Pro Max-UA Remote Control System (Universal) 


The Pro Max-UA Universal Adapter Model offers the capability to connect to virtually any 
controller, regardless of manufacturer. This system consists of: 





Figure 6: Complete Pro Max-UA System 


Pro Max-UA Parts List 









































Part No. Ref. Description 
PM-XMTR 1 Pro Max Remote radio transmitter 
PM-RCVR 2 Pro Max Remote receiver 
PM-SER99 3 36” remote cable 
PM-UADAPT 4 Universal adapter 
32 PC 5 30” permanent connector 
500055 6 Pro Max User Manual 
PM-CASE 7 Pro Max carrying case 
PM-ANT-XMTR |8 Antenna, BNC 
PM-ANT-RCVR |9 Antenna, hinged, BNC 








Page 15 


Pro Max User's Manual Rain Master Irrigation Systems 





The Universal Adapter is equipped with a 35-conductor connection cable RMIS Part Number 
32PC, which must be physically wired to each station of the generic controller. 


Note: If you have purchased model Pro Max-UA and you need to connect to a 
Rain Master controller, the Universal Adapter box (PM-UDAPT) is not 
required. Refer to section 2.0 for installation and operation. 


In cases where the controller does not provide the required 24 Volts AC, a step-down 
transformer is employed to convert standard 117 Volts AC or 220 Volts AC to 24 Volts AC. 


3.1 Using the Pro Max-UA Universal Adapter with a Non Rain Master 
Controller 


The controller serves only two purposes when using the Universal Adapter. 


First, it provides 24 Volts AC for the Pro Max receiver. Never allow more than the “normal” 24 
Volts AC (up to 28 Volts AC maximum) to enter the Pro Max receiver through the wires 
designated for 24 Volts AC. If the controller runs ON a voltage other than 24 Volts AC, use a 
step-down transformer to convert the voltage to 24 Volts AC for input to the Pro Max receiver. 
Transformers that convert higher voltages to 24 Volts AC are available from Rain Master. 


Secondly, the controller serves as a point of connection for the field wires and the Pro Max 
receiver's output. Usually the point of connection is the terminal strip or a quick disconnect 
within the controller or pedestal. Rain Master offers several types of connector cables for wiring 
to the controller. The RMIS Part Number 32PC or RMIS Part Number 24PC Permanent 
Connector Cable, which is intended to be permanently connected to the controller. The other is 
the RMIS Part Number 32TC Temporary Connector using alligator clips. 


3.20 Installing the Pro Max-UA System 


To install a Permanent Connector, follow the instructions below. Prior to installation, please 
observe the following precautions: 





CAREFUL CAUTION DANGER 


WARNING: STOP - PLEASE READ ALL INSTRUCTIONS AND 
THE FOLLOWING WARNING MESSAGES 
BEFORE OPERATING THIS EQUIPMENT. 











Always use with the approved Rain Master cable connector assemblies (RMIS Part Number 
24PC, RMIS Part Number 32PC, RMIS Part Number 32TC, RMIS Part Number 32EX) Use of 
any other connector will void the warranty and may damage the Pro Max remote control system. 


NEVER allow more than the “normal” 24 Volts AC to enter the Universal Adapter on 
any of its wires. If there is any question about a connection voltage, check the voltages 
with a voltmeter. 


NEVER operate the Pro Max transmitter without the CORRECT antenna properly 
installed. 


Page 16 


Rain Master Irrigation Systems Pro Max User's Manual 





NEVER connect the Universal Adapter to more than one controller at a time. 


Procedure (Refer to Figure 7) 


Step 1 
Step 2 


Remove power from the controller. 


Connect a single wire to each station (up to 32) of the RMIS Part Number 32PC 
wiring harness at the controller's terminal strip. The field wiring should remain 
connected and in place. Simply add the RMIS Part Number 32PC wiring to it. 
Make sure to follow the station color code-wiring list illustrated ON the back 
cover of this manual. 


Note: The chart defines the connections for the following cables: 
RMIS Part Number 32PC (supplied with Pro Max-UA), 
RMIS Part Number 24PC, 12PC, and RMIS Part Number 
32TC. 


Make sure that any unused station wires on the PC cables are insulated and will 
not short to any metal object. 


If there is a Master Valve and/or Pump in the system, make sure you understand 
how they are controlled before hooking up the Master Valve and/or Pump wire 
of the Permanent Connector. If there is any doubt - find out before connecting it 
to a voltage above the “normal” 24Volts AC will damage the Pro Max Pro Max 
receiver unit. 


If the Controller Supplies 24 Volts AC to activate the Master Valve/Pump, then 
connect the Master Valve/Pump wire of the Permanent Connector to the 
controller' s Master Valve/Pump terminal. 


If the Controller acts as a switch to activate the Master Valve/Pump Finding two 
terminals in the controller associated with the Master Valve/Pump usually, but 
not always, indicates that a relay will be required. The relay is wired such that 
its coil terminals are activated by the Master Valve/Pump and COMMON of the 
PC and its switch contacts are in parallel with the controller's two terminals, see 


Figure 4 below. 
To MV/P Switch 
Type Terminals 


of controller 


From MV/P wire 
of the Interface 
Cable 


Common of the 
Cable or 
Controller 


mE 


Figure 7: Relay (such as Rain Master RLY1) 


Page 17 


Pro Max User's Manual Rain Master Irrigation Systems 





Step 3 
Step 4 


Step 5 


Step 6 
Step 7 


Step 8 


Step 9 


Connect the wire for the PC Cable COMMON to the COMMON terminal of the 
controller. 


Important! If 24 Volts AC is not available from the controller’s terminal strip, 
see Section 3.5 and skip to Step 6 below. 


Connect the wire from the PC cables 24 Volts AC to the 24 Volts AC terminal 
of the controller. Note that the PC cable has only one wire for 24 Volts AC 
despite the controller having two 24 Volts AC terminals. This is because the 
controller takes one of its 24 Volts AC terminals and connects it to the 
COMMON terminal and you have already attached the PC cables COMMON 
wire to the controller s COMMON terminal. 


You must find which 24 Volts AC terminal on the controller is NOT electrically 
the same as the controller s COMMON terminal and connect the PC's 24 Volt 
AC wire to it. 


Using a voltmeter, power up the controller and set the voltmeter on a 30 Volts 
or higher AC scale. Place one of the voltmeter leads ON the controller's 
COMMON terminal and use the other lead of the meter to read each of the 24 
Volt AC terminals. Connect the PC cables 24 Volt AC wire to whichever 
terminal gives a reading of 24 Volt AC on the meter. 


If the controller does not have any terminals marked 24 Volts AC then leave 
one of the voltmeter leads ON the controllers COMMON and try the other lead 
of the meter to measure the low voltage wires ON the secondary of the 
controller's transformer. Connect the PC cables 24 Volts AC wire to whichever 
terminal provides a reading of 24 Volts AC ON the meter. 


Place the Rain switch in the OFF or Rain position. 


Connect the 9-pin female end of the PM-SER99 cable to the Pro Max receiver 
and the male end to the universal adapter. Hands tighten the screw locks. 


Align the large connector of the RMIS Part Number 32PC cable with the 
connector ON the universal adapter and plug them together. 


Reconnect power to the controller. Refer to the following table: 





Upon Receiver Connection 








Beep Response Description 





1 Beep (1/2 sec) Ready for use. 





2 Beeps 


Multi-Pro Max receiver mode: 
e Requires corresponding access code to enable Pro 
Max receiver operation. 





3 Beeps 


Failed internal diagnostic tests. Contact Rain Master. 








Page 18 


No Beeps 








Check the 24 Volts AC and COMMON connections. 


Rain Master Irrigation Systems Pro Max User's Manual 





3.3 Temporary Connector Installation 


The RMIS Part Number 32TC Temporary Cable is wired in the exact same fashion as the 
Permanent Cable Connector described above except that it uses alligator clips for connection to 
the terminal strip within the controller so that it may be easily installed and removed. Follow the 
connection instructions for the permanent connector; be very careful that the alligator clips are 
secure and not “shorting” to any metal or each other. 


3.4  Disconnecting the Pro Max-UA from a Non-Rain Master Controller 
To disconnect the universal adaptor, use the following procedure: 


Step 1 Disconnect the large 37 pin connector plug from the universal adaptor by 
grasping the plug's body, not by the cable, and pull straight out. 


3.5 Non-Rain Master Controllers Lacking 24 Volts AC 


24 Volts AC is required to power the Universal Adapter. If 24 Volts AC is not available from the 
controller, use a step-down transformer to convert from the line voltage (usually 117 or 240 
Volts AC) to 24 Volts AC and run the 24 Volts AC wire into the PC cable to the two wires 
designated for 24 Volts AC and COMMON. There is no need to worry about the polarity of 
these two connections. Additionally, connect the PC cables COMMON wire to the controller's 
COMMON terminal. Do not connect the PC cables 24 Volts AC wire to the controller. 











Figure 8: Pro Max-UA Installation to a Non-Rain Master Controller 


Page 19 


Pro Max User's Manual Rain Master Irrigation Systems 





3.6 Disconnecting the Pro Max-UA from a Non-Rain Master Controller 
To disconnect the universal adaptor, use the following procedure: 


Step 1 Disconnect the large 37 pin connector plug from the universal adaptor by 
grasping the plug’ s body, not by the cable, and pull straight out. 


3.7  Non-Rain Master Controllers Lacking 24 Volts AC 


24 Volts AC is required to power the Universal Adapter. If 24 Volts AC is not available from the 
controller, use a step-down transformer to convert from the line voltage (usually 117 or 240 
Volts AC) to 24 Volts AC and run the 24 Volts AC wire into the PC cable to the two wires 
designated for 24 Volts AC and COMMON. There is no need to worry about the polarity of 
these two connections. Additionally, connect the PC cables COMMON wire to the controller's 
COMMON terminal. Do not connect the PC cables 24 Volts AC wire to the controller. 


Non-Rain Master Controller 
without 24 VAC 


COMMON 


COMMON on PC 


High Voltage 
Input 24 VAC 
Output of 
Transformer 
» 24 VAC on PC 





Figure 9: Non-Rain Master Controller 24 Volts AC 


3.8 Permanent Wire Connections 


A permanent mount connector can be installed on any controller so that the Pro Max-UA can be 
easily installed and disconnected without having to deal with wiring connections. Three parts are 
required (see Figure 9). 


]. RMIS Part Number 32PC (or appropriate size cable) 
2. RMIS Part Number CMAD (chassis mount adaptor) 
3. RMIS Part Number 32EX (48" extension cable) 


Page 20 


Rain Master Irrigation Systems Pro Max User's Manual 





3.9 Keystroke Operation 


Refer to section 2.3. 








Figure 10: Pro Max-UA Permanent Connection 


Page 21 


Pro Max User's Manual Rain Master Irrigation Systems 





4.0 Detailed Operation 


4.1 Remote Operation 


When the remote Pro Max receiver is connected to a Rain Master controller, all running 
programs are aborted, any stations and/or any master valves or pumps that are ON will be turned 
OFF. During the time the remote is connected, the controller will display the “Remote” message. 
Some controllers will blank the display or display additional information. 


When the remote is disconnected, all stations and any Master Valve or Pumps, which are ON, 
will be turned OFF. The only exception are programs, their operation remains unaffected upon 
disconnection of the Pro Max receiver. (See section 4.8) 


The Pro Max Series remote commands are an extended set of the older Rain Master 
RTS/RR/RRAD remote control. The user interface for Pro Max remains identical when 
performing like functions. The Pro Max remote control system however has several newer 
capabilities and features, which will be delimited in subsequent sections. 


In general, turning a station ON or OFF is independent of the master valve operation. That is, 
turning a station ON will not affect the state of the master valve and vice versa. The exception to 
this is timed station operation. Turning a station ON for a certain period of time will 
automatically select the proper master valve and/or pump as required in order to perform 
irrigation. 

With the older Rain Master RTS series remote system, only one station was allowed to be on at a 
time. All remote key operations resulted in the previous station being turned off, prior to the next 
station turning on. This is also true with Pro Max with one exception. The ADD STATIONS 
feature has been incorporated so that multiple stations may be turned on simultaneously. 


Each time a key is depressed at the Pro Max transmitter, a confirmation audio beep is generated. 
Upon receipt of the command, the Pro Max receiver also generates a confirmation beep. 
Consequently, basic Pro Max system performance can be verified by hitting a key at the Pro Max 
transmitter while listening for the corresponding beep at the Pro Max receiver. 


4.2 Stations On and Off 


When one of the Pro Max transmitter's keys is pressed, a signal is transmitted and an audible 
tone is generated to acknowledge that the signal has been transmitted. 


All stations, except the Master Valve/Pump, are turned on by pressing the number of the station 
followed by the ON key. To turn off a station, simply press the OFF key. To turn the station on 
again, press the ON key. There is no need to press the station's number until a new station is 
desired. 


Example: To turn Station 12 on, then off, and then on again. 


“aH 66 


Page 22 


Rain Master Irrigation Systems Pro Max User's Manual 





Example: To go to Station 3, there is no need to turn 12 off. 


The controller automatically turned Station 12 off prior to turning Station 3 on. 





4.3 Auto Up and Auto down Keys 


For convenience and the rapid checkout of a system, pressing Auto Up will turn off the current 
station and turn on the next sequential station number. There is no need to enter the station 
number. 


Note: If the last station in a Rain Master controller is reached and Auto-Up is 
pressed, wrap-around occurs (station 1 turns on). In a Pro Max-UA model, 
wrap-around occurs after station 32 is reached. 


Similarly, pressing Auto Down will turn off the current station and turn on the next lower station 
number. 


Once you find the station you want, you may turn it on and off simply by pressing the ON and 
OFF keys. There is no need to know the station number. 


Example: You come to a job site and you know it has a problem but you don’t know which 
station has the problem. Simply hook up the Pro Max receiver, go out to the field 
and press Auto Up until you find the problem, then use the ON and OFF keys. 


4.4 On and Off Keys 


When the ON key is pressed, the station previously entered will be turned on, any other station 
that was on will be turned off. 


The previous station may have been entered explicitly by the digit keys or implicitly by using the 
AUTO UP or AUTO DOWN keys. When the remote is first connected and the ON key is 
pressed, nothing happens because the previous station is undefined. 


When OFF is pressed, any station that was on will be turned off. 


4.5 Master Valve/Pump Key 


The Master Valve/Pump may be turned on or off at anytime. Its on/off state is unaffected, as 
other valves are turned on or off. Therefore, checkout of an electrical problem on any valve may 
be accomplished without actually watering, simply by turning the Master Valve/Pump off. This 
assumes the system has a Master Valve and/or Pump. 


Example: To turn the Master Valve/Pump on, 


. au 
Press: PUMP 


To turn it off, 


ia MV 
TOSS: PUMP 


Page 23 


Pro Max User's Manual Rain Master Irrigation Systems 





Refer to section 2.3 for additional Master Valve and Pump operations, which are applicable to 
the Evolution DX2 controller. 


4.6 Controller Access Code 


The Access Code key is used to enable/disable the remote control Pro Max receiver. This allows 
the user to have numerous Pro Max receivers permanently attached to Rain Master Controllers or 
(any manufacturer's controllers) at different geographic sites each with their own Controller 
Access Code. One transmitter can be used to address them individually. 


Access codes are factory-defined numbers ranging from 1 - 999. These codes are factory 
programmable and should be requested at the time the unit is ordered. You must know the 
Controller Access Code of the individual Pro Max receivers. The access code number of any Pro 
Max receiver is listed within the Pro Max receiver serial number on the Pro Max receiver label. 


Example: S/N RX031001-007-001 


The access code appears as the third set of 3 digits (last digits) following the second dash; in this 
case, the access code is 001. 


Example: To enable Pro Max receiver number 1, 


ACCESS 
Press: CODE ER 


Receiver number 1 is now enabled and responds to all commands. 





Example: To disable Pro Max receiver number 1, 


ACCESS 
Press: CODE 
Pro Max receiver number 1 is now disabled and will not respond to any commands. The attached 


Rain Master controller returns to its automatic mode and operates as if the remote has been 
disconnected. 


Note 1: It is possible to have more than one Pro Max receiver enabled simultaneously 
(broadcast mode). In this mode, all enabled Pro Max receivers would respond to 
commands from the Pro Max transmitter. 


Note 2: It is also possible to disable all enabled Pro Max receivers without using their 
Controller Access Code by pressing: 


ACCESS 
CODE 


Note 3: the Pro Max receivers will automatically time-out (after 8 hours) if a Pro Max receiver 
is left enabled and no remote activity has occurred. The controller shall then resume its 
normal operation (return to automatic mode). 





Page 24 


Rain Master Irrigation Systems Pro Max User's Manual 





4.7 Add Stations 


The Add Stations feature allows additional stations to be added to the current operating station 
group. Simultaneous station operation is important for testing system hydraulics and operation of 
multi-station irrigation systems. 


Example: To add a station, 


Station number 1 will operate in addition to any current station, which may be in operation. If no 
station is currently in operation, then station 1 will be the only station on. 


Example: To turn the added stations off, 


Additional stations may be added in the same manner. 


Warning: The use of the Add Stations feature is limited to the maximum amperage 

DER supplied by the controller. Even though the Pro Max universal adapter is 

protected against over-current, it is possible that non-Rain Master 
controllers may blow a fuse and/or damage the controller if excessive 
current is drawn. Caution should be exercised when using this feature. 


Note: The Add Stations only allows up to 5 stations and 1 master valve to be 
turned ON at the same time. Attempting to turn on a sixth station will 
turn the previous 5 stations off. The master valve will remain unaffected. 


4.7.1 Add Stations - On Key 


Pressing the ON key during multiple station operation will turn off all stations except the one 
corresponding to the current number. The remote will resume standard remote operation 
executing only one station at a time. 


4.7.2. Add Stations - Auto Up and Auto down Keys 


Pressing AUTO UP or AUTO DOWN during multiple station operation will advance the 
previously entered number station accordingly and turn off all other stations. The remote will 
resume standard remote operations executing only one station at a time. 


4.7.3 Add Stations - Off Key 


If the OFF key is pressed during multiple station operations, all stations will be turned off. 


If the OFF key is preceded by digits, then only the entered station number will be turned off. 


Page 25 


Pro Max User's Manual Rain Master Irrigation Systems 





4.8 Program Function 
The Program feature is designed to be used only with the following Rain Master products: 
e RME Sentar 
e RME Hawk 
e RME Eagle 
e Evolution DX2 Controllers 


The Program feature allows any program currently in the controller to be turned either on or off. 
This allows special programs to be executed for testing, evaluation, and supplemental irrigation 
cycles. 


Example: To start Program 4, 


~ Bao 


To turn Program 4 off, 





Press: 





Once started, the program will run to completion whether or not the Pro Max receiver remains 
connected, whether the Access Code is turned off, or whether 60 minutes have elapsed. 


4.8.1 Program — Off Key 


Pressing the OFF key while the program is running will turn the program off and the controller 
returns to the Automatic Mode of the operation. 


Similarly, when the program is completed, the controller returns to the Automatic Mode of 
operation. 


4.8.2 Program — Auto up Key 


Pressing the AUTO UP key while the program is running will advance the program to the next 
station. If the last station in the program is running, the program will terminate. 


4.8.3 Program - Sensor Switches 


The position of the Rain Switch will not affect the running of the program. The program will still 
run if the Rain Switch is in the “NO WATERING" position. 


Programs configured under the control of sensors will continue to operate as configured. When a 
sensor detects sufficient watering, the program will shut off watering. 


Page 26 


Rain Master Irrigation Systems Pro Max User's Manual 





4.9 Minutes Function 


The Minutes feature allows a station to be operated for a specified amount of time up to 60 
minutes maximum. A station must first be selected and turned on prior to using the Minutes key. 


Example: To turn on station 15 for 47 minutes, 


— EB E3 Ó E3 EA = 


The station will turn on immediately after pressing the ON key and all other stations will go off. 
The time count will start when the Minutes key has been pressed. 


Note: If a station number is not entered, the currently selected station will be 
turned on for the specified time of 47 minutes. 


The maximum allowable remote control operations time is 60 minutes. 
When the selected station is on, the only 3 keys that are recognized are: 


1. OFF Key - The OFF key will turn the station, the master valve or the pump off. The 
controller will return to the Automatic Mode. 


2. AUTO UP - The current station turns off and the next sequential station turns on. The 
minute counter automatically re-starts. 


3. AUTO DOWN - The current station turns off and the previous sequential station turns 
on. The minute counter automatically re-starts. 


When the station run time is complete, either by the operator pressing the OFF key or the run 
time as elapsed, the controller will return to the status of a newly connected remote. 


e AUTO UP will turn on station 1 
e AUTO DOWN will turn on the next sequential station 
e ADD STATIONS feature will do nothing, as there is no current number defined. 


4.10 Beeper Operation 


Beep tones are used to indicate the operational status of the Pro Max transmitter or Pro Max 
receiver. A valid beep occurs when a key is pressed and the Pro Max transmitter unit 
acknowledges the key entry by producing a single short tone burst. An invalid response occurs 
when a invalid key is pressed, resulting in a series of short tones going on and off continuously. 


The Pro Max receiver will emit a valid beep whenever a valid command is received from the Pro 
Max transmitter. An invalid beep will occur whenever an illegal command sequence is received. 


4.10.1 Power on Beeper Operation 


When a Pro Max receiver is first powered on, a single beep is emitted for a duration of 
approximately 1/2 second. The single beep indicates that the Pro Max receiver is operational. 


If the Pro Max receiver emits two beeps on power up this indicates that the Pro Max receiver is 
programmed for access code operation. Refer to section 4.6 for details on access code operation. 


Page 27 


Pro Max User's Manual Rain Master Irrigation Systems 





If the Pro Max receiver emits three beeps upon power up or at any other time, this indicates an 
invalid condition. Remove power and try again. If the invalid operational condition continues, 
contact your local Rain Master distributor. 


4.10.2 Universal Adapter Over-Current Detection Beeper 


If an over-current condition in the Universal Adapter has been detected, a beep sequence of once 
every six seconds will occur. This sequence will repeat until the power is cycled or the 
Controller Access Code times out. 


4.11 Transmitter Battery Replacement 


When the battery is low, the normal “beep” sound, which is emitted when a key is pressed, will 
instead be an intermittent fast beep. The battery should be replaced immediately. 


The Pro Max transmitter battery is a 6-volt dual lithium battery pack, GE/Sanyo (CR-P2), 
Duracell (DL223A), Energizer (EL223AP) or equivalent. This battery is available at most 
retailers, including Radio Shack, Home Depot, or from your local Rain Master distributor. 





Figure 11: Battery Replacement 


To replace the battery refer to Figure 11 and do the following steps: 


Step 1 Remove the two screws from the Pro Max transmitter bottom end cap. Pull the 
end cap off to expose the battery. 


Step 2 Remove the battery from the battery compartment. 


Step3 The battery holder is designed with an extruded tab(s) in the center to prevent 
the battery from being installed backwards. 


Position the new battery as shown and insert with the battery terminals facing 
into the Pro Max transmitter. 


Note: Be sure to push battery all the way in. 


Page 28 


Rain Master Irrigation Systems Pro Max User's Manual 





Step 4 With the battery contacts properly mated; press the reset button located at the 
end of the circuit board, to reset the electronics. 


Step 5 Replace the bottom rubber end-cap plate and secure it with the two screws. This 
ends the battery replacement procedure. 


The Pro Max transmitter has been designed to minimize power consumption, to prolong battery 
life. Power is only consumed for a very short duration whenever a key is depressed. 


Due to the various use of the Pro Max transmitter, it is impossible to predict exactly how long 
the battery will last. In general, you may expect a battery life of 6 to 12 months. 


Page 29 


Pro Max User's Manual Rain Master Irrigation Systems 





5.0 Checking Out Electrical Problems 
5.1 Field Wiring Shorts, the Receiver, and Rain Master Controllers 


If you suspect there is a short circuit in either the wiring or the solenoid of a station, then it is 
important to understand what will occur when you transmit a signal, to the controller, to turn on 
that station. 


Example: If there is a short circuit on station 3 and you send a command to turn on Station 
3, the controller will attempt to turn it on. If the controller has a built-in over- 
current detector (standard on the Rain Master RME Sentar, RME Hawk, RME 
Eagle, and Evolution DX2 controllers), the station will not be allowed to turn on. 
The user should isolate/repair the short-circuit and try again. The Pro Max system 
will remain fully operational. 


5.2 Field Wiring Shorts, the Receiver, and Non Rain Master Controllers 


The built-in over-current sensing capability of the Pro Max Universal Adapter protects the unit 
and controller transformer against damage due to short circuits in solenoids or field wiring. If 
you attempt to turn on a valve, which has a wiring problem, the Pro Max will sense the over- 
current and turn that station OFF immediately. The Pro Max receiver will beep every six seconds 
to indicate that you have attempted to operate a faulty station. Other stations will operate 
normally. 


Once the problem is fixed, the station can be retried without having to walk back to the 
controller. 


When you finish your testing and return to the controller, the beeping indicates that you have a 
problem with one or more stations. Power down and then up the Pro Max receiver, this will 
eliminate the beeping. 


5.3 A Note about Solenoids 


A solenoid should never be turned ON without a plunger in place. If this is done, the solenoid 
may draw from 2 to 5 times its normal electrical current. This will cause a rapid and dangerous 
heating cycle and may destroy the solenoid very quickly. Depending upon the solenoid, this 
electrical current may be enough to activate the attached controller's circuit breaker, pop the 
fuse, or damage the controller. 


Page 30 


Rain Master Irrigation Systems Pro Max User's Manual 





6.0 Troubleshooting 





Pro Max System Troubleshooting 

















Symptom Action 
No beep tone when Pro Replace Battery. 
Max transmitter key is 
pressed. 
No beep tone when Pro Remove end cap and press the Pro Max transmitter- 


Max transmitter is pressed | reset button. Ref. Figure 10 Page 33. 
after changing the battery. 


"Rapid beeps" when Pro Replace battery. Rapid beeps indicate low battery 





Max transmitter key is condition. 
pressed. 
Key presses beep at the e Check installation and antenna connections. 


Pro Max transmitter but NO | e Remove PM-SER99 cable from the controller 
valves turn ON at Rain and then reinsert. 


Master controller. ; : i 
e Upon re-insertion of the cable listen for a Pro 


Max receiver tone(s). 
- One tone OK (approximately 1/2 second) 


- Two tones OK (see Section 4.6 Access 
Codes) 


- Any other tones (contact factory) 


e Press the AUTO UP key and listen for a 
confirmation beep at the Pro Max receiver. If 
no beep heard contact factory. 


- The controller display should show 
remote station activity as AUTO UP is 
pressed. If nothing displayed contact 
factory. 

e Verify water is ON at selected stations. If no 
water is available, is a Master Valve/Pump 
required? Verify field station wiring is correct. 


e Confirm that the remote continues to work at 
maximum distance. If not, contact factory. 





Receiver beeps once every | e The universal adapter has detected an 
six seconds continuously. electrical short circuit when attempting to turn 
For non-Rain Master ON a station. 

controller. (Model Pro 




















Page 31 


Pro Max User's Manual Rain Master Irrigation Systems 








Pro Max System Troubleshooting 








Symptom Action 


Max-UA) - Check the valve solenoid and replace if 
necessary. 








- Check the station wiring for short circuit 
to common, check for insulation nicks 
and exposed wiring in standing water. 


- When field problem is fixed, turn station 
back ON. 
- Cycle Pro Max receiver power to reset the 
unit. 
Note: The Pro Max system will continue to 
operate normally for non-shorted stations. 





Keys beep at Pro Max e Check installation, and antenna connections 
transmitter but no valves (see Section 3.2, Figure 8 and Figure 9) 

turn on at a non Rain 
Master controller. (Model 
Pro Max-UA) 


e Remove the large 37-pin connector from the 
universal adapter assembly and then re-insert. 
e Upon re-insertion of the cable listen for the 
Pro Max receiver tone(s). 
- No tone - check the 24 Volts AC and 
common connections. 
- One tone, OK (approximately 1/2 
second) 


- Two tones, OK (see Section 4.6 Access 
Code) 


- Any other tones (contact factory) 
e Press the AUTO UP key and listen for a 


confirmation beep at the Pro Max receiver. If 
no beep contact factory. 


e Verify water is ON at the selected stations. If 
no water is available, is a Master Valve/Pump 
required? Verify field station wiring is correct. 


e Confirm that the remote continues to work at 
maximum distance. If not, contact factory. 




















Page 32 


Rain Master Irrigation Systems 


Pro Max User's Manual 





7.0 
7.1 


Pro Max Specifications 


Pro Max Transmitter 


Operating Frequency................ 
Modulation type ..................... 
Frequency Stability................... 
Power Output......................... 
Power Source........................ 


Operating Temperature Range... 


Storage Temperature Range...... 
Humidity Range....................... 


7.2 Pro Max Receiver 


Operating Frequency................ 
SOHSIIVILY A a ipu Ea Eire 
POWer SOUFCe. «oe eco eon nno 


Operating Temperature Range... 


Storage Temperature Range... 
Humidity Range....................... 
DIMENSIONS: nina 


7.3 Pro Max Universal Adapter 


Power SOU lia 
Operating Temperature Range... 


Storage Temperature Range... 

Humidity Range....................... 
Output Capability..................... 
DIMENSIONS i sleale 


*Connectors not included 


7.4 Pro Max Carrying Case 


DIMENSIONS................ Lt 


154.600 MHz 

Frequency Modulation 

.005% 

1 Watt nominal 

One 6 volt type CR-P2 lithium battery 
0 to 60 degrees Celsius (32 to 140 ° 
Fahrenheit) 

-20 to 70 degrees Celsius (-4 to 158 ? 
Fahrenheit) 

0 to 9096 non-condensing 

CR-P2 Lithium 6V (user replaceable) 
1 season (typical) 

3"L x 1 3/8"W x 5 27H (less antenna) 
12 oz. 


154.600 MHz 

0.4 micro-volt typical 

22 — 32 Volts AC 50/60 Hz. 

0 to 60 degrees Celsius (32 to 140 ? 
Fahrenheit) 

-20 to 70 degrees Celsius (-4 to 158 ? 
Fahrenheit) 

0 to 90% non-condensing 
64°Lx34"Wx1 1/16"H * 

11 oz. 


22 — 32 Volts AC 50/60 Hz. 

0 to 60 degrees Celsius (32 to 140 ? 
Fahrenheit) 

-20 to 70 degrees Celsius (-4 to 158 ? 
Fahrenheit) 

0 to 9096 non-condensing 

1 amp/station, 1.5 amp total 
64°Lx34"Wx1 1/16"H * 

13 oz. 


12 L x 7 VW x 10"H 


Page 33 


Pro Max User's Manual 


Rain Master Irrigation Systems 





8.0 Pro Max Series Parts List 


Model 


Pro Max 
Pro Max-UA 


Accessories 
PMRKIT 


CMAD 


12PC 


RMIS Part Number 
24PC 
RMIS Part Number 
32PC 
RMIS Part Number 
32TC 


RMIS Part Number 
32EX 


Pro Max 
Replacement Parts 


PM-XMTR 
PM-RCVR 
PM-UADAPT 


PM-PM-ANT 
PM-PM-ANT2 


PM-RCVR-ANT* 
PM-XMTR-ANT* 
PM-SER99 





Option 
417-2013 


PM-CASE 
JACK-IRC 


Description 

The complete remote set for Rain Master Controllers 

The complete remote set for Non-Rain Master Controllers, 
include universal adaptor. 


Description 

Permanent mount remote Pro Max receiver, includes 
antenna (PM-PM-ANT) cables & hardware. 

Chassis mount access door, gives access to the permanent 
connectors through the wall of other manufacturers 
controllers. 

30" permanent connector cable for 12 stations and Master 
Valve/Pump on non-Rain Master controllers. 

30" permanent connector cable for 24 stations and Master 
Valve/Pump on non-Rain Master controllers. 

30" permanent connector for cable 32 stations and Master 
Valve/Pump on non-Rain Master controllers. 

60" temporary connector with alligator clips, for up to 32 
stations and Master Valve/Pump on non-Rain Master 
controllers 

48" extension cable to connect to Pro Max receiver and 
PC or TC cables (Typical use with CMAD) 


Description 


Pro Max remote Pro Max transmitter, includes battery and 
antenna (PM-XMTR-ANT) 

Pro Max remote Pro Max receiver and antenna (PM- 
RCVR-ANT) 

Universal adapter (32 station and Master Valve/Pump 
output control) 

Pro Max permanent mount 16" chassis antenna 

Pro Max permanent mount Low-Profile, encapsulated 
chassis mounted antenna 

Replacement antenna for Pro Max receiver (right angle) 
Replacement antenna for Pro Max transmitter 

36" remote cable with a DB9 (9-pin) connector 


Description 

Receiver connection cable for Rain Master controllers 
with rear permanent mount interface. 

Pro Max Remote Case 

Factory installed rear permanent interface RME Hawk, 
RME Sentar & Evolution DX2 only. Includes access code 


e (Add - T to these parts for telescope high gain version.) 


Page 34 


Rain Master Irrigation Systems Pro Max User's Manual 





Rain Master Limited Warranty 


Rain Master Irrigation Systems Inc. warrants to the first customer purchaser that this Rain 
Master brand product (the “product”), when shipped in its original container, will be free from 
defective workmanship, and materials and agrees that it will, at its option, either repair the defect 
or replace the defective product or part thereof at no charge to the purchaser for parts or labor for 
the time period set forth below. 


This warranty does not apply to any appearance items of the product nor to any product has the 
exterior of which been altered or modified in design or construction. (See additional exclusion 
below). This limited warranty described above is in addition to whatever implied warranties may 
be granted to purchasers by law. 


This limited warranty does not apply to product failure caused by improper installation or 
grounding, improper handling, physical abuse, neglect, whether accidental or malicious, acts of 
God, such as lightning and/or power surges, floods, earthquakes, hurricane, tornados, vandalism 
etc. 


(All implied warranties including the warranty of merchantability, and fit for use are limited to 
the period(s) from date of purchase set forth below). 


Neither the sales personnel of the seller nor any other person is authorized to make any 
warranties other than those described above, or to extend the duration of any warranties beyond 
the time period described herein. 


The warranties described above shall be the sole and exclusive warranties granted by Rain 
Master Irrigation Systems Inc. and shall be the sole and exclusive remedy available to the 
purchaser. Correction of defects, in the manner and period of time described herein, shall 
constitute complete fulfillment of all liabilities and responsibilities of Rain Master to the 
purchaser with respect to the product, and shall constitute full satisfaction of all claims, whether 
based on contract, negligence, strict liability or otherwise. 


In no event shall Rain Master be liable or in any way responsible, for any damages or defects in 
the product which were caused by repairs or attempted repairs performed by anyone other than a 
Rain Master Service dealer or center. Nor shall Rain Master be liable or in any way responsible 
for an incidental or consequential economic or property damage. Some states do not allow the 
exclusion of incidental or consequential damages, so the above exclusion may not apply to you. 
The Rain Master Pro Max series products carry a 2 year limited warranty unless otherwise 
specified. In order to enforce the rights of this limited warranty, please follow the directions as 
described in the following sections. 


SERVICE 
Prior to sending your Pro Max system for service: 
1. Please refer to the troubleshooting section of the manual for possible solutions. 


2. Contact Rain Master Technical Support at (805) 527-4498. Be sure you can describe your 
problem(s) and if possible, be able to reproduce your problem(s) while ON the phone. You 
will need the serial numbers of both your Pro Max transmitter and Pro Max receiver. 


3. If required to ship, ensure the unit is properly packaged, preferably in the original shipping 
case. Include all cables and components, and make sure adequate packaging material is used 
to protect the unit(s) from shipping abuse. 


Page 35 


Pro Max User's Manual Rain Master Irrigation Systems 





4. Enclose a complete description of the type of problem that is occurring, and be sure to 
include your name, address and phone number where you can be reached. 


5. Product can be: 


A. Sent or take to an authorized Rain Master Distributor. Call Rain Master at (805) 527- 
4498 for nearest distributor. 


B. Sentortake to: 
Rain Master Irrigation Systems 
Attn: Service Dept. 
310-B Royal Ave. 
Simi Valley, CA 93063 


Warning: This equipment has been tested and found to comply with the limits for Class 
A digital device pursuant to part 15 of the FCC Rules. These limits are 
designed to provide reasonable protection against harmful interference when 
the equipment is operated in a commercial environment. This equipment 
generates, uses, and can radiate radio frequency energy and if not installed 
and used in accordance with the instruction manual, may cause interference 
to radio communications. Operation of this equipment in a residential area is 
likely to cause interference in which case the user will be required to correct 
the interference at the user's expense. 


The user is cautioned that changes and modifications made to the equipment 
without approval of the manufacturer could void the user's authority to 
operate this equipment. 


Page 36 


Wiring List for PROMAX-UA 









































































































































Station Base Color 1° Stripe 2 Stripe Cable 
Color Color 
1 Black Large 
2 White Large 
3 Red Large 
4 Green Large 
5 Orange Large 
6 Blue Large 
7 White Black Large 
8 Red Black Large 
9 Green Black Large 
10 Orange Black Large 
11 Blue Black Large 
12 Black White Large 
13 Blue Red Large 
14 Red Green Large 
15 Orange Green Large 
16 Black White Red Large 
17 White Black Red Large 
18 Red Black White Large 
19 Green Black White Large 
20 Orange Black White Large 
21 Blue Black White Large 
22 Black Red Green Large 
23 White Red Green Large 
24 Red Black Green Large 
25 Black Small 
26 White Small 
27 Red Small 
28 Green Small 
29 Brown Small 
30 Blue Small 
31 Orange Small 
32 Yellow Small 
MV/P Green White Large 
COMMON Orange Red (Standard) Large 
COMMON* Red White Large 
24 VAC Blue White Large 
*Some cables may use this color scheme for common 