Document text
ExtremeWare Release Notes
Software Version 7.3.1b3
Extreme Networks, Inc.
3585 Monroe Street
Santa Clara, California 95051
(888) 257-3000
http://www.extremenetworks.com
Published: December 2004
Part Number: 120237-00 Rev 01
Alpine, Altitude, BlackDiamond, EPICenter, Ethernet Everywhere, Extreme Ethernet Everywhere, Extreme Networks,
Extreme Turbodrive, Extreme Velocity, ExtremeWare, ExtremeWorks, GlobalPx Content Director, the Go Purple Extreme
Solution Partners Logo, ServiceWatch, Summit, the Summit7i Logo, and the Color Purple, among others, are trademarks
or registered trademarks of Extreme Networks, Inc. or its subsidiaries in the United States and other countries. Other
names and marks may be the property of their respective owners.
© 2004 Extreme Networks, Inc. All Rights Reserved.
Specifications are subject to change without notice.
NetWare and Novell are registered trademarks of Novell, Inc. Merit is a registered trademark of Merit Network, Inc.
Solaris is a trademark of Sun Microsystems, Inc. F5, BIG/ip, and 3DNS are registered trademarks of F5 Networks, Inc.
see/IT is a trademark of F5 Networks, Inc.
All other registered trademarks, trademarks and service marks are property of their respective owners.
Author: Susan Lynott
Editor:
Production: Susan Lynott
Special Thanks: Paul
Contents
Chapter1 Overview
New and Enhanced Features in ExtremeWare 7.3 13
Cable Diagnostics 13
Port Aggregate Bandwidth Control 13
Standard Multinetting 14
PIM Snooping 14
IP Address Security 14
CPU DoS Protect Enhancements 14
SNMP Traps and MIBs for CPU DoS Protect 14
IPDA Subnet Lookup 14
sFlow 14
Stand-alone ELRP 15
RADIUS Server Configuration Enhancements in ExtremeWare 7.3 15
Configuring RADIUS Servers 15
Configuring RADIUS Authentication and Accounting Servers 15
Showing the Current RADIUS Server Authentication Setting 15
Configuring a RADIUS Server for Network Login Users (Wired and Wireless) 16
Management Access with RADIUS Enabled 16
Trusted Organizational Unique Identifier 18
Trusted OUI and Trusted MAC CLI Commands 19
Link Aggregation Control Protocol (LACP) 21
Unified Access Feature Support 22
New .Bxtr Software Image 22
Supported Hardware 22
BlackDiamond Component Support 23
Alpine Component Support 24
Summit Component Support 25
GBIC Support 26
Mini-GBIC Support 26
XENPAK Module Support 27
Channel Mapping 27
ExtremeWare 7.3.1b3 Release Notes 3
Contents
Chapter 2
Chapter 3
Chapter 4
Tested Third-Party Products
Tested NICs
WPA-Compliant Wireless NICs
Tested RADIUS Servers
Tested Third-Party Clients
Tested Laptops
Tested PDAs
Tested Tablets
Tested Scanner
Tested IP Phones
Tested Embedded WNIC Modules
Tested Spectralink Supported Handsets
Tested Spectralink Gateway
Legacy IP Phones
Legacy Phones with Dongle
Upgrading to ExtremeWare 7.3
Staying Current
Upgrading ExtremeWare
Upgrading Switches to ExtremeWare 7.3
Save the Current Configuration
Upgrade the BootROM to Version 8.2
Upgrade to ExtremeWare 6.1.9
Upgrade to ExtremeWare 6.2.2b56
Upgrade to ExtremeWare 7.3
Upgrade T1, E1, or T3 Modules from a Release Prior to ExtremeWare 6.1.8b79
Upgrade T1, E1, or T3 Modules from ExtremeWare 6.1.8b79 or Later
Upgrade ATM, MPLS, ARM, or PoS Modules from a Release Prior to ExtremeWare 7.3
Upgrading an Alpine 3802 to ExtremeWare 7.3
Downgrading Switches
Supported Limits
Supported Limits
Clarifications, Known Behaviors, and Resolved Issues
Clarifications and Known Behaviors
General
HTTPS Access
Unable to Download Image to a Switch with 500 Configured IP VLANs
NP API Generates Error Messages When Disabling a Slot Containing an OC3 or OC12 Module
Cannot Ping localHost Loopback Interface
Hot-swapping an MSM3 Causes Invalid MAC Address on Backplane EEPROM
MSM-3 Displays Broken Connection Recovered Message when Hot-swapping and Inserting an
MSM64i
Hot-Swapping an MSM Causes I/O Modules to Reset
36
36
38
39
39
40
40
40
40
40
40
40
41
41
42
43
43
44
44
45
45
45
46
47
48
48
49
49
51
59
59
59
59
59
60
60
60
60
ExtremeWare 7.3.1b3 Release Notes
Contents
Downloaded Configuration Might Cause Syntax Error With Enable Web Command 60
Wireless Error Messages Display During Bootup 60
show pim snooping Command Shows an Incomplete List of Packets Snooped 60
MSM-Failover Link-Down Not Working on the Remote Side 61
ExtremeWare 7.3 introduces the concept of QoS profiles on a VLAN 61
Repeatedly Hot-Swapping the MSM Might Cause Loss of Connectivity 61
Cannot Save or Download a Configuration If a “ghost” Process is Running in the Background 61
Creating an ACL with a Filter-Precedence of 11 or 12 Generates a Conflict Error with
cpu-dos-protect 61
Hot-Swapping Modules Might Cause Misleading Error Messages 61
G12Ti Module Link Detection Fails 61
Autonegotiation Between Fiber Optic Ports is not Possible 62
show log Command Memory Error 62
unconfigure switch all Command Should Not Restore the Downloaded Configuration 62
WLANSYST Output of the show log Command is Not Correct 62
System Related — All Systems 62
The NVRAM Dirty Bit Being Set from the PoE Code 62
PoE Firmware image Download is not Available in Base Image 62
Autonegotiation Setting Not Preserved on Added and Deleted Loopback Ports 62
Configure Slot for PoE Before Configuring or Downloading PoE Configuration 62
The show log Command Truncates Long Commands 63
The show log Display Truncates Configuration Parsing 63
Do Not Create Single-Character Names 63
Smart Redundancy Enabled in Saved Configuration 63
Microsoft Load Balancing 63
Telnet and the show ports Command 63
The show configuration Output 63
Upgrading to ExtremeWare 7.0 and Bi-Directional Rate Shaping 63
Upgrading to ExtremeWare 7.0 and Debug-Trace 63
Upgrading to ExtremeWare 7.0 and OSPF 64
Blank Space in show port info detail Command Output 64
Using an ExtremeWare 7.0 Configuration with an Earlier Image 64
Console Response with a Large Number of ARP Entries 64
The show log chronological Command 64
BOOTP-Dependent Routes in Downloaded Configuration not Created 64
The disable learning Command and Flooding 64
Port Tag Limitation 64
WinSCP2 Not Supported 65
BlackDiamond 65
Twister Access Error 65
Loopback Port Must be on Same Module on a BlackDiamond Switch 65
Two Trap Messages Sent for Hard Reset/Soft Reset on BlackDiamond 6816 65
Targeted LDP Sessions Become Operational When MPLS is Disabled 65
BGP Fast Fail-over Does Not Work for Change of IP Address 65
CMT Group Will Not Forward Traffic Without a Master Slot 66
Connection to G12SXi Might be Lost 66
MPLS and ESRP 66
EAPS and Hitless Failover 66
Cross-Module Trunking and Hitless Failover 66
Autonegotiation Off Command Accepted on 10 Gigabit Ethernet Modules 66
ExtremeWare 7.3.1b3 Release Notes 5
Contents
Memory Corruption with RRO on PATH Message
No Longer Display Stale TLS NHLFE Entries
MPLS Module Might Not Be Recognized
LSP NHLFE Not Updated
Removing Second MPLS Module Causes Traffic to Stop
Disabling One MSM Might Cause Loss of Throughput
Cannot Delete an LSP Previously Referenced by a TLS Tunnel
EAPS Trap Not Sent if Connection is Through I/O Port
The card-down Option
10 Gigabit Ethernet and CMT
XENPAK with the BlackDiamond 6816
Cross-Module Trunking Not Supported on MSM64i's
Cross-Module Trunking Module Support
Master Slot Must Be Active for CMT
MSM-3 Log Might Be Out of Chronological Order
Source Addresses Might Age Out of FDB
Do Not Use Static FDB Entries with CMT
Saving Health Check Configuration After Failure Causes Console Crash
Diagnostics on MSM-3 with Hitless Failover Causes Failover and Spurious Message
Do Not Configure a Port-Based Backplane Algorithm When CMT is Enabled
Cross-Module Trunking and ACLs
ExtremeWare 7.0 (and Later) Does Not Support xmodem
4,000 VLANs on a BlackDiamond
E1 Module and the restart port Command
PPP Links Through E1 modules
Slot Failure Messages During a Broadcast Storm
No Image Information Reported to SNMP with One MSM
BlackDiamond 6816 MSM C and D Diagnostics Messages not in Syslog
Disabling CLI Paging from the Slave MSM64i
The unconfig switch all Command
BlackDiamond 6816 MIB Value for Input Power Voltage
Alpine
Mirroring Failure on an Alpine 3808 with GM4x Module After a Save and Reboot
With IE5.0 Vista Page is not Accessible Through HTTPS
Autonegotiation on VDSL Ports Set Incorrect Speed
VDSL Ports do not Support Jumbo Frames
New Accounts with WAN Module Installed are pppuser
Limited Commands Mode
VDSL Modules in a Half-Duplex Link
Summit
Spurious Summit48si Power Supply Messages
Output of the show log Command
The unconfigure switch all Command Clears the Default VLAN from s0
Health Check Error Messages
Summit48i Redundant PHY
Summit48i Single Fiber Signal Loss
SNMP Results for Power Sources
Summit48si MIB value for Input Power Voltage
66
67
67
67
67
67
67
67
67
68
68
68
68
69
69
69
69
69
69
69
69
69
70
70
70
70
70
70
70
70
70
71
71
71
71
71
71
71
71
71
71
72
72
72
72
72
72
72
ExtremeWare 7.3.1b3 Release Notes
Command Line Interface (CLD
Mirroring Cannot be Disabled
Console Does Not Wait for User Input
Command Does Not Function
show fdb vpls Command Does Not Accurately Show the Total of FDB Entries
clear counters Command Does Not Clear Number Transmitted in a MPLS Health Check
show fdb port Command Does Not Reflect Correct FDB Data for that Port
Maximum Number of ESRP Groups Supported in the ESRP MIB is Incorrect
Not All configure debug-trace Options Are Displayed
SNMP Trap Commands Not Supported
The show ports mgmt info Output Missing Flags
Press [Return] Key Twice With enable temperature-log Command
User Sessions Cannot Enable CLI Paging
Switching and VLANs
Renew/Refresh Required After Each Logout To Get IP Address
Packets Sent to VRRP-MAC That Do Not Belong to the VRID of the VLAN are also Being
Accepted
The show iproute Output
MAC-Based VLAN Configuration Not Saved
Contents
72
72
72
73
73
73
73
73
73
74
74
74
74
74
74
74
74
74
Load Share Group Might Fail Back to Group with Fewer Ports When Using Software Redundant
Ports
Saving ip-mtu Settings
VLAN priority and STP, EDP
Default Routes or Static Routes
Configuring a Protocol Filter with ‘fff’
Deleting Protocols from a VLAN
MAC-Based VLANs and DHCP Relay
VLAN to VLAN Access Profiles
FDB
FDB Entries Disappear Before Aging Timeout
Cannot Add FDB Entry for Management VLAN
MAC Security
FDB Aging Timer
Configure Less Than 400 Ports in a VLAN
Load Sharing
Removing Modules During CMT Testing Causes Loss of Traffic
74
75
75
75
75
75
75
75
76
76
76
76
76
76
76
76
Backplane Algorithm Not Working Properly When Changing the Algorithm from Address-Based to
Port-Based 76
Autonegotiation 76
Round Robin Load Sharing [t
Port Based Load Sharing on Summit7i 77
Alpine and Cross Module Load Sharing 77
Load Sharing and Specific Ports in a Load Share Group 77
Disabling Load Sharing if the Master is Down Generates Error 77
Mirroring 77
Port Mirroring Does Not Work on Rate Shaping Loopback Port 77
Delete Mirroring Filters Before Disabling Mirroring 77
Port from Deleted VLAN Mirrors When Added to New VLAN on Alpine Switch 77
Do Not Configure Port Mirroring While Port is Down 78
ExtremeWare 7.3.1b3 Release Notes 7
Contents
ELSM 78
Spurious Error Message with ELSM 78
Spanning Tree 78
Adding or Deleting a Port from a VLAN Flushes FDB on All STP Protected VLANs 78
show vlan STP Output is not Correct 78
STP Topology Change in One STP Domain (S1) Flushes FDB in Other STP Domain (S2) 78
STP CPU Utility Usage Increases and Drops Ping Packets 78
Disabling ignore-bpdu Adds CPU MAC Entry to FDB 78
Enabling STP on MAC-based VLANs Might Cause Connectivity Loss 78
Incorrect Log Message 79
RSTP Does Not Detect Topology Change 79
Disabling STP Might Display Topology Change 79
FDB Not Flushed After Link Failure with RSTP 79
Do Not Configure All Ports in s0 79
Error Messages with Topology Changes 79
Large STPD Configuration Download Might Reboot Switch 79
A Large STP Configuration with 10 Link Transitions 79
Configure Fewer than 4,000 VLANs in an STPD 79
Output of show stpName port detail Command in Hex Format 80
If You Delete a Port from the STPD, You Cannot Add It Through a VLAN 80
The unconfigure stp Command Does Not Clear All Configurations 80
Enabling ignore-bpdu or ignore-stp 80
Configuring a VLAN from Vista 80
STP and VLAN Tagging 80
EMISTP and Ingress Rate Shaping 80
Upgrading From an ExtremeWare 6.1.9 (or earlier) Configuration 80
ESRP 81
ESRP Master Does Not Change to the Neutral State 81
The disable slot all Command Generates EDP Errors 81
Large Configurations Might Lock Console when Enabling and Disabling s0 81
ESRP and Protocol-Based VLANs 81
ESRP and Load Sharing 81
Hot-Swapping a Module with 5,000 ACLs 81
Traffic Convergence Time 81
ESRP PDUs on Ports 81
ELRP 82
ELRP and Ingress Rate Shaping 82
VRRP 82
Proxy ARP Replies on VRRP Enabled VLANs Are Incorrect 82
Backup Transition Creates Duplicate Packets 82
QoS 82
QoS Profiles Applied to Non-Master Ports in Load Sharing Groups 82
QoS Profile Statistics Are Not Shown for Non-master Ports in a Loadshared/CMT Group 82
The gosprofile Accepts a Value Greater than 100% 82
Re-Ordering Access List Precedence Numbers 82
Access List FDB Entries not Cleaned Up 83
Access Lists Using the IP Deny Any Rule 83
Access Lists and IP Fragmentation 83
QoS Configuration Bandwidth Parameters 83
8 ExtremeWare 7.3.1b3 Release Notes
Contents
Creating Access Lists from Multiple Sessions 83
5,120 Access Lists and SNMP 83
Monitoring QoS and the show port qos Command 83
MPLS 83
Cannot Delete TLS VLAN After Deleting TLS Tunnel When MPLS is Disabled 83
IP Interface of Local End-point VLAN for TLS Tunnel or VPLS Can be Modified 83
Clear Counters Command Does Not Clear RSVP LSP Count 84
Targeted LDP Sessions Become Operational When MPLS is Disabled 84
Targeted LDP Sessions do not Come Up When OSPF is Disabled and Router ID is Automatic 84
Bi-Directional Rate Shaping 84
Secondary MAC Used for Rate Shaping Not Released 84
Aggregate-Bandwidth Granularity Correction 84
SecureMac Flags Not Shown 85
Locking and Unlocking Learning 85
1000Base-T Ports as Loopback Ports 85
EAPS 85
Configuring Cross Module Trunking Causes EAPS Failure 85
Shared-Port Link ID Limits 86
EAPS Performance Statistics 86
ESRP and EAPS Secondary Port 86
Incorrect show vlan Output 86
IP Unicast Routing 87
Reset the FDB Aging Timer 87
No Static ARP Entries 87
ARP Entry Age 87
Multinetting and the Show VLAN Stats Command 87
Multinetting and VRRP 87
IPv4 Routing 87
PIM CRP Timer Error 87
RIP Routing 87
Problems with Default Route Origination Addition and Purging 87
RIPv1 Learned Routes Might Not Be Purged Immediately 87
RIPv2 Authentication 88
RIP in Conjunction with other Routing Protocols 88
OSPF 88
OSPF Originate Default Cost Can Be Set Incorrectly 88
LSA Batch Interval Not Supported 88
Static Route with Switch’s Address as Gateway Not Advertised 88
AS-external LSAs Might Not Be Regenerated 88
Error Message Not Generated 88
Disable OSPF Before Adding or Removing External Area Filters 88
IS-IS 88
Unicast Packets Considered Broadcast 88
BGP 89
A Session Down Due to Max Prefix Limit Will Not Re-establish 89
Large Number of Access Profiles and a Peer Reset 89
Default Route Might Not Be Deleted 89
BGP Aggregation with a Maximum Prefix of 300,000 89
Redistributing BGP Routes to OSPF 89
ExtremeWare 7.3.1b3 Release Notes 9
Contents
IP Multicast Routing 89
PIM SM Switch Reboot will not Re-establish the Existing Multicast Traffic Present Before Reboot 89
PIM DM Switch Reboot Might Delay Re-establishment of Traffic 89
(S,G) Packets are Sent to CPU When Route to Source is Lost in Last Hop Router 89
The unconfigure igmp Command Does Not Unconfigure All Parameters 90
If PIM-Snooping is Enabled on Current Traffic, All (S,G) Entries Will be Marked as Invalid 90
Enable or Disable IGMP Snooping on a Sub-VLAN 90
Do Not Disable IGMP Snooping with Static Snooping Entries 90
(S,G) Entry Not Created if RP is Rebooted 90
Cisco Interoperation 90
Traffic Rate Exceeding Last Hop Threshold 90
Security and Access Policies 90
Changing VLAN and Wireless Port IP Causes RADIUS Proxy Failure 90
Cannot Apply a New Port after Creating a Trusted MAC Entry on a VLAN 90
Unconfiguring a Slot will not Remove the Ports from Network Login and Network Login Cannot be
Disabled 91
Proxy ARP Setting Should Take Effect When Network Login is Enabled 91
Wireless Clients Forced to Reauthenticate During Roaming 91
Enhanced DOS Protect Rate-Limit Configurations Are Lost 91
Disable Trusted MAC Globally Will Not Automatically Remove Network Login Ports Added as
Tagged Port in other VLANs 91
After Network Login Authentication, Cannot Get an iP Address from the DHCP Server 91
Wireless Ports Do Not Come Online if VLAN Gets IP Address from BOOTP 91
Special Characters Accepted in WEP Plaintext Key 92
A New ACL Might Not Block Packets 92
Roaming Client MAC Might be Aged Out 92
False EAPOL-Flooding Alarm 92
EAP-Failure Messages Not Sent When Client is Unauthenticated by an Administrator 92
Do Not Upload a Configuration Containing Authenticated Clients 93
The show netlogin Output Might Display Wrong Authentication 93
ICMP Access Lists and ignore-overlap 93
CPU DoS Protect and ACL Precedence 93
MSM Failover Clears Logins 93
Network Login RADIUS Server Interoperability 93
Network Login Supplicant Software Interoperability 94
RADIUS and the BlackDiamond 94
RADIUS and Telnet 94
The show netlogin Command Output 94
SLB and Flow Redirection 94
Do Not Use SLB and NAT on the Same Switch 94
Enumeration Mode Redirects ICMP Packets 95
Cache Servers Set To “Down” Under Sustained High Traffic Loads 95
Health Checking Cannot be Disabled 95
NAT 95
Do Not Use SLB and NAT on the Same Switch 95
NAT Rule Configuration Not Updated 95
Vista 95
Failed Vista Login Logged Incorrectly 95
No 10 Gigabit Option for Port Speed 95
SNMP Community and Trapreceiver Information Not Updated 95
10 ExtremeWare 7.3.1b3 Release Notes
Use CLI to Configure SNMPv3
Incorrect Minimum Limit on OSPF Page
Cannot Create User Accounts
Cannot Enable STP
Alpine 3808 Erroneously Displays Four PSUs
Cannot Add Trap Receiver or Community String
Blackhole Flag Missing
Multicast Address Display
Configuration Statistics PSU Display
Vista and RADIUS
Configuration Options with Large Number of Interfaces
SNMP
Performing an SNMP Mibwalk and Polling qBridgeMIB Might Cause High Utilization
ESRP SNMP MIB Table Election Algorithms Missing
The configure snmp community Command Replaced
Only Warm Start Smart Trap Sent After Power Cycle
extremeVlanGlobalMappingTable Exists only for Backward Compatibility
ExtremeEapsTable Not Browsable
MIB Does Not Differentiate Between 110 and 220 VAC
The trapDestOwner is Required in the trapDestTable
Cannot Delete Default Community Strings
Do Not Configure an SNMPv3 Community String with more than 32 Characters
Modular Switch get Error
SNMP and ACLs
Incrementing the Interface Value
Trap Receivers as Broadcast Entry
Bridge MIB Attributes
SNMP Time-out Setting
SNMP Access Profile
SNMP and Auto-negotiation Settings
SNMP and the FDB MIB
Extreme Fan Traps
Extreme Power Supply Traps
Diagnostics and Troubleshooting
OC12 Module Might Report False External Loopback Failure on External Test
A3ci Running Normal Diagnostics Hangs in the “diag” State
NP Module Error Messages in the Log After Running Diagnostics
Errors Not Displayed in show diagnostics Output
Incorrect show diagnostics Output for BlackDiamond 6816
Entering q Does Not Quit Diagnostics Display
Single MSM Not Taken Offline
Automatic Memory Scanning Can Trigger Incorrect Reboot Loop Detection
Packet Diagnostics Display Backplane Incorrectly
Packet Diagnostics Display Wrong Slot Name
Bus-Stats Error Messages
Spurious Message When system-down is Configured
The use configuration Command
Output of the show diagnostics Command
Configure Auto-Recovery to online or Alarm-Level to traps
Error Count Not Accurate
Contents
96
96
96
96
96
96
96
96
96
96
97
97
97
97
97
97
98
98
98
98
98
98
98
98
98
99
99
99
99
99
99
99
99
100
100
100
100
100
100
100
100
100
101
101
101
101
101
101
101
101
ExtremeWare 7.3.1b3 Release Notes
Contents
Configuring Diagnostics Mode Off 102
Disable Remote Syslog Before Enabling IPARP Debug-Tracing 102
Bridging 102
Extended Diagnostics Does Not Include Backplane Connection 102
Documentation 102
Summit48si LED Description Incorrect 102
reauth-period Range is Not Correct 102
EAPS is now supported with Basic Layer 3 License 102
VRRP and ESRP Can Be Simultaneously Enabled 102
The Auto-Recovery Threshold Applies only to BlackDiamond I/O Modules 103
Configure Auto Negotiation to Recognize Single Fiber Failure as Port Failure 103
UAA 103
TCP Transmission Causes an SNMP Send Error when the AP Comes Up 103
Some IAPP Debug Messages Are Not Logged 103
DHCP Port is Disabled When Changing a VLAN Tag 103
Port Related Configuration Returns an Error During Configuration Download 103
ifSpecific Variable of ifEntry Table Shows Incorrect Characters for Wireless Interfaces 103
Issues Resolved in ExtremeWare 7.3.1b3 104
General 104
EAPS 104
Multicast 104
Network Login 104
Security and Access Policies 104
SNMP 104
VLANs 105
Issues Resolved in ExtremeWare 7.3.0b49 105
General 105
Alpine 105
Security and Access Policies 105
UAA 106
QoS 106
PoE 106
SNMP 106
ESRP 106
CLI 106
Issues Resolved in ExtremeWare 7.3.0b44 107
General 107
Summit 107
BlackDiamond 107
Alpine 108
Vista 108
SNMP 108
Spanning Tree 108
12 ExtremeWare 7.3.1b3 Release Notes
Contents
Security and Access Policies 108
Switching and VLANs 108
Network Login 109
Diagnostics 109
VRRP 109
ExtremeWare 7.3.1b3 Release Notes 13
Contents
14 ExtremeWare 7.3.1b3 Release Notes
Overview
These Release Notes document ExtremeWare® 7.3.1b3. ExtremeWare 7.3 enables new hardware products
and software features.
A NOTE
You can only load ExtremeWare 7.0 (or later) on a switch running ExtremeWare 6.2.2 (or later). To
install ExtremeWare 7.3, see “Upgrading ExtremeWare” on page 43.
This chapter contains the following sections:
e New and Enhanced Features in ExtremeWare 7.3 on page 13
e Supported Hardware on page 22
New and Enhanced Features in ExtremeWare 7.3
Following are descriptions of features introduced or enhanced in ExtremeWare 7.3. These features are
documented in detail in the ExtremeWare 7.3 Software User Guide or the ExtremeWare 7.3 Software
Command Reference Guide, unless otherwise noted.
Cable Diagnostics
The Cable Diagnostic Module (CDM) is used to collect cable diagnostic values for the physical ports on
the system. CDM is implemented as two submodules:
e DIAG submodule—Implements the diagnostic functionality of the CDM
e TMR submodule—Handles all timer related issues
Port Aggregate Bandwidth Control
Port Aggregate Bandwidth Control is a feature designed to control aggregate bandwidth of all queues
on a specific port. It is usually deployed when a customer uses several queues for classifying traffic and
needs to restrict the total queue bandwidth to a specific amount.
ExtremeWare 7.3.1b3 Release Notes 13
Overview
Standard Multinetting
Multinetting provides a way of assigning multiple subnets to a routing interface. This benefits networks
that outgrow their allocated subnets. When the network grows due to a lack of address ranges in the
original subnet, a new subnet is allocated. In the Extreme Networks implementation, routing interfaces
can be assigned multiple subnets. IP routing occurs between the different subnets of the same interface,
as well as between the subnets of different interfaces.
PIM Snooping
In networks where a Layer 2 switch interconnects several routers, such as an Internet exchange point
(IXP), the switch floods IP multicast packets on all multicast router ports by default, even if there are no
multicast receivers downstream. With PIM snooping enabled, the switch restricts multicast packets for
each IP multicast group to only those multicast router ports that have downstream receivers joined to
that group. When you enable PIM snooping, the switch learns which multicast router ports need to
receive the multicast traffic within a specific VLAN by listening to the PIM hello messages, PIM join
and prune messages, and bidirectional PIM designated forwarder-election messages.
IP Address Security
CPU DoS Protect Enhancements
This feature allows you to manage and reduce high CPU utilization caused by an ICMP DOS attack. It
will also help your reduce or eliminate the impact of such attacks on switch performance.
SNMP Traps and MIBs for CPU DoS Protect
SNMP traps and MIBs provide access to the statistics available in the ExtremeWare Command Line
Interface (CLI).
IPDA Subnet Lookup
The Extreme Networks IPDA subnet lookup feature Increases IP address coverage in the hardware
forwarding table. It makes it possible for a switch to cover the entire IP address range, from A class to C
class, through setting the length of the IPDA subnet lookup mask. The expansion helps guarantee
wire-speed performance in a L3 switch for all ports.
It also offers better protection of internal traffic from malicious end-users or virus infected clients.
Scanning for virus-infected end users, or malicious users, can cause the FDB table to fill up quickly. The
attacks can significantly hurt the quality of internal traffic if all L3 forwarding is made by only host
lookup. The IPDA subnet lookup feature makes the attack traffic use the IPFDB subnet forwarding table
instead of the host forwarding table. This means that internal traffic, which uses the host forwarding
table can preserve the same quality when under attack.
sFlow
sFlow is a technology for monitoring traffic in data networks containing switches and routers. In
particular, it defines the sampling mechanisms implemented in an sFlow Agent for monitoring traffic,
the sFlow MIB for controlling the sFlow Agent, and the format of sample data used by the sFlow Agent
when forwarding data to a central data collector.
14 ExtremeWare 7.3.1b3 Release Notes
New and Enhanced Features in ExtremeWare 7.3
Stand-alone ELRP
Extreme Loop Recovery Protocol (ELRP) is used to detect network loops in an L2 network. A switch
running ELRP transmits multicast packets with a special MAC destination address out of some, or all,
of the ports belonging to a VLAN. All the other switches in the network treat this packet as a regular,
multicast packet and flood it to all the ports belonging to the VLAN. If the packets transmitted by a
switch are received back by that switch, this indicates a loop in the layer-2 network. Once a loop is
detected by ELRP, different recovery actions can be taken such as blocking certain ports to prevent
loops, or logging a message to the system log. The action taken is largely dependent on the protocol
using ELRP to detect loops in the network.
RADIUS Server Configuration Enhancements in ExtremeWare 7.3
ExtremeWare 7.3 has added enhancements for configuring the RADIUS server:
Configuring RADIUS Servers
In ExtremeWare 7.3, you can configure up to four RADIUS servers: two primary servers and two
secondary servers. P1 and P2 indicates the two primary server settings. S1 and S2 indicates the two
secondary server settings. The Default Authentication Primary and Secondary server setting for both
management and network access is P1 and S1.
Configuring RADIUS Authentication and Accounting Servers
If you set the RADIUS server for management or network access for the current session, the setting
takes precedence over the default setting. If you unconfigure the setting, the default authentication
setting takes effect again.
e Use the configure auth mgmt-access command to set up management access for the primary and
secondary RADIUS servers.
e Use the configure auth netlogin radius command to configure a set of primary or secondary
RADIUS servers for network access.
Showing the Current RADIUS Server Authentication Setting
Use the show auth command to show the authentication servers configured for mgmt-access/netlogin
type of sessions. If you use the configure auth mgmt-access radius or the configure auth
netlogin radius command, the show auth command will show the session setting for the
management or Network Login sessions. If both configure auth mgmt-access radius and
configure auth netlogin radius commands are used, then the show auth command will display
the session setting for both the management and Network Login sessions, and omits the Default Auth
Setting.
The show auth command will not show anything if you are not specifically setting up authentication
using the configure auth command and:
e RADIUS is disabled.
e P1 and S1 are not configured. In other words, you have enabled RADIUS without configuring a
RADIUS server.
e P2 and S2 are configured; P1 and S1 are unconfigured. Although the show radius command still
shows P2 and 82, by default, these RADIUS settings are not set in the default authentication.
ExtremeWare 7.3.1b3 Release Notes 15
Overview
Configuring a RADIUS Server for Network Login Users (Wired and Wireless)
If you want to configure RADIUS for Network Login users only and do not want to configure RADIUS
for management access, do the following:
1 Configure the first primary or secondary RADIUS server.
2 Configure the second primary or secondary RADIUS server using a fictitious IP address.
3 Configure authentication to the fictitious IP address using the config auth mgmt-access radius
command.
4 Login to the switch. RADIUS authentication will always fail, causing the switch to time out and go
to the local account. Authentication is performed at the local account.
Management Access with RADIUS Enabled
Switch management access must use RADIUS for authentication when RADIUS is enabled on the
switch.
Workaround: If you want to use local authentication for management access, you should configure
invalid RADIUS servers (both primary and secondary) for management access. This will cause RADIUS
authentication to timeout and fall back to local authentication. This feature works as designed today
and will be enhanced in a future release.
RADIUS Examples
Example 1:
config radius primary server 10.201.30.8 client-ip 10.201.56.3
config radius secondary server 10.201.30.9 client-ip 10.201.56.3
config radius primary server 1.1.1.1 client-ip 10.201.56.3
config radius primary shared-secret secret
config radius secondary shared-secret secret
enable radius
configure auth netlogin radius primary 10.201.30.8 secondary 10.201.30.9
config auth mgmt-access radius primary 1.1.1.1
Output 1:
* mars:32 # show radius
Radius: enabled
Primary Radius server shared-secret "qijxou"
Secondary Radius server shared-secret "qijxou"
Radius Server Connect Timeout sec 3
Radius servers:
Server name: 10.201.30.8
Server type: Primary
IP address: 10.201.30.8
Server IP Port: 1645
Client address: 10.201.56.3
Radius Server Connect Timeout sec: 3
Shared secret: qijxou
Access Requests: 0 Access Accepts: 0 Access Rejects: 0
Access Challenges: 0 Access Retransmits: 0 Client timeouts: 0
Bad authenticators: 0 Unknown types: 0 Round Trip Time: 0 sec(s)
Server name: FO 20 13.0459
Server type: Secondary
16 ExtremeWare 7.3.1b3 Release Notes
New and Enhanced Features in ExtremeWare 7.3
IP address: 10.201.30.9
Server IP Port: 1645
Client address: 10.201.56.3
Radius Server Connect Timeout sec: 3
Shared secret: qijxou
Access Requests: O Access Accepts: 0 Access Rejects: 0
Access Challenges: 0 Access Retransmits: 0 Client timeouts: 0
Bad authenticators: 0 Unknown types: 0 Round Trip Time: 0 sec(s)
Server name: i Reap Bre
Server type: Primary
IP address: sig ee bere
Server IP Port: 1645
Client address: 10.201.56.3
Radius Server Connect Timeout sec: 3
Shared secret: qijxou
Access Requests: 6 Access Accepts: 0 Access Rejects:0
Access Challenges: 0 Access Retransmits: Client timeouts: 2
Bad authenticators: 0 Unknown types: 0 Round Trip Time: 42949672 sec(s)
Radius Accounting: disabled
Radius Acct Server Connect Timeout sec 3
Primary radius accounting servers:
Secondary radius accounting servers:
* mars:33 # show auth
Session Type mgmt-—access
Not configured
Not configured
Authentication Server Type Radius
Primary Authentication Server Deledda
Secondary Authentication Server None
Primary Accounting Server None
Secondary Accounting Server None
Session Type netlogin
Authentication Server Type Radius
Primary Authentication Server 10.201.30.8
Secondary Authentication Server 10.201.30.9
Primary Accounting Server None
Secondary Accounting Server None
* mars:34 #
Example 2:
config radius primary server 10.201.30.8 client-ip 10.201.56.3
config
radius secondary server 10.201.30.9 client-ip 10.201.56.3
config radius primary shared-secret secret
config radius secondary shared-secret secret
enable radius
configure tacacs primary server 1.1.1.1 client-ip 10.201.56.3
config tacacs primary shared-secret secret
enable tacacs
configure auth netlogin radius primary 10.201.30.8 secondary 10.201.30.9
config auth mgmt-access tacacs primary 1.1.1.1
ExtremeWare 7.3.1b3 Release Notes
Overview
Output 2:
* mars:36 # show auth
Session Type : mgmt-—access
Authentication Server Type : Tacacs
Primary Authentication Server Fie ore tad Bete
Secondary Authentication Server : None
Primary Accounting Server : None
Secondary Accounting Server : None
Session Type : netlogin
Authentication Server Type : Radius
Primary Authentication Server z 0.2013 0..28
Secondary Authentication Server : 10.201.30.9
Primary Accounting Server : None
Secondary Accounting Server : None
* mars:37 #
Trusted Organizational Unique Identifier
The Trusted Organizational Unique Identifier (OUI) feature allows devices, such as IP phones, without
802.1x (Network Login) capability to obtain IP addresses through DHCP on a network login enabled
port.
A trusted OUI configuration requires an IP phone and a desktop PC, both of which are connected to a
single wired port on an Extreme Networks switch. The desktop PC must use untagged 802.1x
authentication. The IP phone must be capable of sending DHCP requests after booting up to obtain IP
address and VLAN ID through the DHCP response. The phone then configures itself to be tagged for
the VLAN ID obtained through the DHCP response.
18 ExtremeWare 7.3.1b3 Release Notes
New and Enhanced Features in ExtremeWare 7.3
Figure 1 shows the sequence of operation for the trusted OUI feature.
Figure 1: Trusted OUI sequence of operation
Figure 1
DHCP request
Untagged
Untagged Switch
802.1x client
Figure 2
DHCP response
DHCP response
packet options
carry the VLAN id Untagged
Untagged Switch
802.1x client
Figure 3
Tagged
Untagged Switch
802.1x client
XM_056
Trusted OUI and Trusted MAC CLI Commands
The switch forwards packets based on the MAC addresses, independent of the 802.1x port state. Prior to
this feature, a network login enabled port cannot be part of a different tagged VLAN. This does not
apply if the trusted MAC feature is enabled on both a global and a VLAN basis.
New CLI commands have been introduced to configure this feature. The following describes each
command:
e Use the create trusted-mac-address command to configure a trusted MAC -address. The mask
keyword is optional. If you do not specify a mask, the default mask of ff:ff:ff:ff:ff:ff is used. If you do
not specify a port list, the trusted MAC is applied to all of the ports in the VLAN. Devices matching
a created trusted-OUI list are allowed to bypass network login using a specified protocol.
ExtremeWare 7.3.1b3 Release Notes 19
Overview
create trusted-mac-address <xx:yy:zz:aa:bb:cc> {mask dd:ee:ff:gg:hh:kk>} vlan
<vlan-name | all> {port <port-list>} {protocol [DHCP |ARP] }
e Use the delete trusted-mac-address to delete a MAC address. If you do not specify the MAC
address to be deleted, all the MAC addresses in the VLAN are deleted.
delete trusted-mac-address {mac-address <xx:yy:zz:aa:bb:cc> {mask
<dd:ee:ff:gg:hh:kk>}} vlan <vlan-name | all> {ports <port-list>}
{protocol [DHCP | ARP] }
e Use the disable trusted-mac-address command to disable trusted OUI or MAC addresses for
port-specific configurations. Disabling this feature will not remove the previous port-specific
configurations.
disable trusted-mac-address {vlan <vlan-name>}
e Use the enabled trusted-mac-address command to enable trusted OUI or MAC addresses for
port-specific configurations. Disabling this feature will not remove the previous port-specific
configurations. The system default is disable trusted-mac-address.
enabled trusted-mac-—address
The global trusted MAC feature should be enabled globally and also with a VLAN for this feature to
be effective.
enabled trusted-mac-address {vlan <vlan-name>}
e Use the show trusted-mac-address command to display the status of the enable/disable keywords
and then displays all of the configured trusted MAC addresses.
show trusted-mac-address {vlan <vlan-name>} {port <port-list>}
20 ExtremeWare 7.3.1b3 Release Notes
New and Enhanced Features in ExtremeWare 7.3
Figure 2: show trusted-mac-address Command Sequence
€
U ~ =a}
—
=
PC IP phone 10.36.11.187
a peer sere
[ee
Alpine 3808
XM_057
Command sequence
create vlan "voice"
configure vlan "voice" tag 120
configure vlan "voice" ipaddress 20.36.11.1 255.255.255.0
configure vlan "voice" add port 8:5 tagged
enable ipforwarding vlan "voice"
create vlan "corp"
configure vlan "corp" tag 9
configure vlan "corp" ipaddress 10.36.11.186 255.0.0.0
configure vlan "corp" add port 8:5 untagged
configure vlan "corp" add port 1:4 tagged
enable ipforwarding vlan "corp"
enable netlogin port 8:5 vlan corp
create trusted-mac-—address mac-address 00:04:0D:28:45:C2 mask FF:FF:FF:FF:FF:FE
corp ports 8:5 protocol dhcp
nable trusted-mac-—address
nable trusted-mac-address vlan corp
enable bootprelay
configure bootprelay add 10.36.11.187
Link Aggregation Control Protocol (LACP)
LACP is part of an IEEE specification (802.3ad) that allows you to bundle several physical ports
together to form a single logical channel. LACP allows a switch to negotiate an automatic bundle by
sending LACP packets to the peer.
Table 1 lists the modules and interface cards used for testing LACP on ExtremeWare 7.3.
Table 1: LACP Testing Matrix, Alpine Modules and NICs
Alpine 3804 Module 1 FM32T | Module 2 G4Tx | Module 4 G16Tx | Module 4 G4x
Server NICs
Built-in Intel 10/100 x* X X N/A
Intel PRO/1000 MTx X X X N/A
Intel PRO/1000 MF N/A N/A NA X
*The built-in 10/100 NIC experienced some link problems when connecting to the FM32T.
ExtremeWare 7.3.1b3 Release Notes
21
Overview
Unified Access Feature Support
ExtremeWare 7.3 supports the following unified access features:
e Wireless network login
e Inter-Access Point Protocol (IAPP), which provides seamless roaming support for data and voice
clients
e Spectralink Voice Protocol (SVP) support for voice over WLAN Spectralink handsets
e Wireless monitoring (AP Scan, Client Scan, Client Statistics)
e Comprehensive wireless security support with WPA/AES
e MAC-RADIUS support for wireless data clients
e Extensive debugging support (MAC, RADIUS, dotlx, WPA, IAPP, AP-Management, and so on)
To use the UAA and PoE features, you must be running the v731b3.xtr or v731b3.Sxtr image.
New .Bxtr Software Image
ExtremeWare 7.3 offers two software images: .xtr and .Bxtr. The .Bxtr software image is available on all
Summit platforms. It does not support the following features:
e UAA (available on Alpine switches only)
e PoE (available on Alpine switches only)
e SSL (HTTPS)
Although the BlackDiamond 6804 and BlackDiamond 6808 switches use the .xtr software image, the
BlackDiamond switches do not support UAA and PoE.
To use SMA and SONET the advanced image (.xtr or Sxtr) must be used (PD3-10674849 and
PD3-10693717).
Supported Hardware
Hardware in the following sections listed in italics is new for this release.
wan
ExtremeWare 7.3 (and later) supports “i
“wan
series or “e” series products only.
Table 2 lists software filenames for the hardware that requires software.
Table 2: Software for supported hardware
Extreme Hardware ExtremeWare Filename BootROM Filename/Version
BlackDiamond 6816 v731b3.Gxtr or v731b3.SGxtr Ngboot8.2.bin/8.2
BlackDiamond 6808 V731b3.xtr or v731b3.Sxtr Ngboot8.2.bin/8.2
BlackDiamond 6804 V731b3.xtr or v731b3.Sxtr Ngboot8.2.bin/8.2
Alpine 3808 v731b3.xtr or V731b3.Sxtr Ngboot8.2.bin/8.2
Alpine 3804 v731b3.xtr or V731b3.Sxtr Ngboot8.2.bin/8.2
Alpine 3802 V731b3.xtr or v731b3.Sxtr/EW-70-3802.mig Ngboot8.2.bin/8.2
Summit7i/7iT v731b3.Bxtr or v731b3.SBxtr Ngboot8.2.bin/8.2
22 ExtremeWare 7.3.1b3 Release Notes
Table 2: Software for supported hardware (continued)
Supported Hardware
Extreme Hardware
ExtremeWare Filename
BootROM Filename/Version
Summitti/1iT v731b3.Bxtr or v731b3.SBxtr Ngboot8.2.bin/8.2
Summit5i/5iT/5iLX v731b3.Bxtr or v731b3.SBxtr Ngboot8.2.bin/8.2
Summit48i v731b3.Bxtr or v731b3.SBxtr Ngboot8.2.bin/8.2
Summit48si v731b3.Bxtr or v731b3.SBxtr Ngboot8.2.bin/8.2
ARM module v731b3.arm v731b3.nprom/1.18
OC3 PoS module V731b3.0c3 V731b3.nprom/1.18
OC12 PoS module
v731b3.0c12
v731b3.nprom/1.18
OC3 ATM module
v731b3.atm3
Vv731b3.nprom/1.18
MPLS module Vv731b3.mpls v731b3.nprom/1.18
T1 module v731b3.t1 t1boot28.wr/2.8
E1 module v731b3.e1 e1boot28.wr/2.8
T3 module V731b3.t3 t8boot28.wr/2.8
A NOTE
The BlackDiamond 6816 requires its own ExtremeWare image. The image that runs on other
BlackDiamond, Alpine, or stackable switches does not support the BlackDiamond 6816.
A NOTE
Systems with 128 MB memory should use the v731b3.Bxtr or v731b3.SBxtr image. To determine how
much memory is available, use the show memory Command.
BlackDiamond Component Support
BlackDiamond components supported with ExtremeWare 7.3, and the minimum ExtremeWare version
required by the chassis to support each component, include:
q y: pp P
Table 3: BlackDiamond component support
BlackDiamond Component | ExtremeWare Required
BlackDiamond 6804 6.2.2b561
BlackDiamond 6808 6.2.2b561
BlackDiamond 6816 6.2.2b561
MSM-3 7.1.1
MSM64i 6.2.2b561
G8Xi 6.1.3
G8Ti 6.1.3
G12S8xi 6.1.4
G16X3 7.0.1
G24T3 7.0.1
F32Fi 6.1.8
ExtremeWare 7.3.1b3 Release Notes
23
Overview
Table 3: BlackDiamond component support (continued)
BlackDiamond Component | ExtremeWare Required
F48Ti 6.1.2
F96Ti 6.1.8
WDMi 6.1.5
10GLRi 7.0
10GX3 7.2.0618
MPLS 7.0
ARM 7.0
P3cMi 7.0
P3cSi 7.0
P12cMi 7.0
P12cSi 7.0
A3cMi 7.0
A3cSi 7.0
DC Power Supply 6.1.5
110 VAC Power Supply 6.1.5
220 VAC Power Supply 6.1.5
1. Older switches do not require ExtremeWare 6.2.2b56. To determine the
minimum revision required for your switch, see Field Notice 115A, here:
http:/Awww.extremenetworks.com/services/documentation/FieldNotices_FN0O115-
MACAddressSoftwareReqmt.asp.
A NOTE
Do not install mixed versions of the power supplies in the same system. Install power supplies of the
same type.
Alpine Component Support
Alpine components supported with ExtremeWare 7.3, and the minimum ExtremeWare version required,
include:
Table 4: Alpine component support
Alpine Component ExtremeWare Required
Alpine 3802 6.2.2b56!
Alpine 3804 6.2.2b56!
Alpine 3808 6.2.2b56!
SMMi 6.2.2b56!
GM-4Si/Xi/Ti 6.1.5
GM-16X3 7.0.1
GM-16T3 7.0.1
FM-32Ti 6.1.5
FM-24MFi 6.1.5
24
ExtremeWare 7.3.1b3 Release Notes
Table 4: Alpine component support (continued)
Alpine Component ExtremeWare Required
FM-24Ti 6.1.7
FM-24SFi 6.1.7
FM-32Pi 7.2.0b18
GM-WDMi 6.1.8
WM-4T1i 7.0.1
WM-4E1i 7.0.1
WM-1T3i 7.0.1
FM-8Vi 7.0.1
AC Power Supply 6.1
DC Power Supply 6.1.5
1. Older switches do not require ExtremeWare 6.2.2b56. To
determine the minimum revision required for your switch,
see Field Notice 115A, here:
http://www.extremenetworks.com/services/documentation/
FieldNotices_FN0O115-MACAddressSoftwareReqmt.asp.
Summit Component Support
Summit components supported with ExtremeWare 7.3, and the minimum ExtremeWare version
required, include:
Table 5: Summit component support
Summit Component ExtremeWare Required
Summitti 6.2.2b56!
Summit5i 6.2.2b56!1
Summit7i 6.2.2b561
Summit7i DC Power Supply 6.2.2b561
Summit48i 6.2.2b561
Summit48si 6.2.2b56!
Summit48si DC Power Supply 7.1.12
1. Older switches do not require ExtremeWare 6.2.2b56. To determine the
minimum revision required for your switch, see Field Notice 115A, here:
http://www.extremenetworks.com/services/documentation/FieldNotices_
FNO115-MACAddressSoftwareReqmt.asp.
2. ExtremeWare 6.2.2 recognizes the Summit48si DC power supply, but
does not indicate the type of PSU installed, issue a warning if both an
AC and a DC PSU are installed in the same chassis, or send an SNMP
trap message when the PSU is hot-swapped.
Supported Hardware
ExtremeWare 7.3.1b3 Release Notes
25
Overview
GBIC Support
GBICs supported with ExtremeWare 7.3, and the minimum ExtremeWare version required, include:
Table 6: GBIC support
GBIC ExtremeWare Required
SX parallel ID 1.0
SX serial ID 2.0
LX parallel ID 1.0
LX serial ID 2.0
ZX 6.2.2
ZX Rev 03 6.2.2
LX70 2.0
LX100 6.1.9
UTP 6.1.9
SX Mini 7.0.1b11
LX Mini 7.0.1b11
ZX Mini 7.0.1b11
The following table describes how each version of ExtremeWare interprets the media type of the
installed GBIC, based on either the Vista web interface, or the show port configuration command.
All versions correctly identify Parallel ID GBIC types; however, some versions do not correctly identify
the Serial ID GBIC type because the Serial ID GBICs were introduced after the software was released.
Table 7: ExtremeWare recognition of GBIC type
ExtremeWare
Version SX Parallel ID LX Parallel ID SX Serial ID LX Serial ID LX70
1.x SX LX Not Supported | Not Supported | Not Supported
2.x SX LX LX LX LX
3.x SX LX CX CX CX
4.x SX LX SX LX LX
6.x SX LX SX LX LX70 (6.1.6 and
above)
7.x SX LX SX LX LX70
Mini-GBIC Support
Extreme products support the Extreme mini-GBIC only. For reliability and stability reasons, third-party
mini-GBICs are not supported at this time.
26
ExtremeWare 7.3.1b3 Release Notes
Channel Mapping
XENPAK Module Support
XENPAK modules supported with ExtremeWare 7.3, the minimum ExtremeWare version required, and
the manufacturers supported include:
Table 8: XENPAK support
XENPAK Module ExtremeWare Required Manufacturers Supported
LR 7.2.0b18 Intel, Opnext
ER 7.2.0b18 Intel, Opnext
Channel Mapping
Table 9 lists the channel mapping for Altitude 300-2i wireless ports connected to a Alpine 3800 series
switch using ExtremeWare 7.3. The UAA features contained in this table apply to Alpine 3800 switches
only.
Table 9: Altitude 300-2i channel mapping
Country 802.11g (802.11b
Country Code 802.11a Channels Channels (Channels
Canada CA 36/40/44/48/52/56/60/64/149/153/157/161/165 1-11 1-11
United States JUS 36/40/44/48/52/56/60/64/149/153/157/161/165 1-11 1-11
Japan JP 34/38/42/46 1-13 1-14
Taiwan TW 56/60/64/149/153/157/161 1-11 1-11
Albania AL None 1-13 1-13
Algeria DZ None 1-13 1-133
Argentina AR 34/38/42/46/56/60/64 None 1-13
Armenia AM 36/40/44/48/52/56/60/64 1-13 1-13
Australia AU 36/40/44/48/52/56/60/64/149/153/157/161 1-13 1-13
Austria AT 36/40/44/48 1-13 1-13
Azerbaijan AZ 36/40/44/48/52/56/60/64 1-13 1-13
Bahrain BH None 1-13 1-13
Belarus BY None 1-13 1-13
Belgium BE 36/40/44/48 1-13 1-13
Belize BZ 149/153/157/161/165 1-13 1-13
Bolivia BO 149/153/157/161/165 1-13 1-13
Brazil BR 36/40/44/48/52/56/60/64/100/104/108/112/116/120/124/128/132/ |1-11 1-11
136/140/149/153/157/161/165
Brunei BN 149/153/157/161/165 1-13 1-13
Darussalam
Bulgaria BG 36/40/44/48/52/56/60/64/100/104/108/112/116/120/124/128/132/ |1-13 1-13
136/140
Chile CL 149/153/157/161/165 1-13 1-13
China CN 149/153/157/161/165 1-13 1-13
Colombia CO 36/40/44/46/52/56/60/64/149/153/157/161/165 1-11 1-11
ExtremeWare 7.3.1b3 Release Notes 27
Overview
Table 9: Altitude 300-21 channel mapping (continued)
Country 802.11g (802.11b
Country Code 802.11a Channels Channels |Channels
Costa Rica CR None 1-13 1-13
Croatia HR 36/40/44/46/52/56/60/64 1-13 1-13
Cyprus CY 36/40/44/48/52/56/60/64/100/104/108/1 12/116/120/124/128/132/ |1-13 1-13
136/140
Czech CZ 36/40/44/48/52/56/60/64 1-13 1-13
Republic
Denmark DK 36/40/44/48/52/56/60/64/100/104/108/1 12/116/120/124/128/132/ |1-13 1-13
136/140
Dominican DO 36/40/44/48/52/56/60/64/149/153/157/161/165 1-11 1-11
Republic
Ecuador EC None None 1-13
Egypt EG None 1-13 1-13
El Salvador |SV None 1-13 1-13
Estonia EE 36/40/44/48/52/56/60/64/100/104/108/1 12/116/120/124/128/132/ |1-13 1-13
136/140
Finland Fl 36/40/44/48/52/56/60/64/100/104/108/1 12/116/120/124/128/132/ |1-13 1-13
136/140
France FR 36/40/44/48/52/56/60/64 1-13 1-13
Georgia GE 36/40/44/48/52/56/60/64 1-13 1-13
Germany DE 36/40/44/48/52/56/60/64/100/104/108/1 12/116/120/124/128/132/ |1-13 1-13
136/140
Greece GR None 1-13 1-13
Guatemala GT 36/40/44/48/52/56/60/64/149/153/157/161/165 1-11 1-11
Honduras HN None 1-13 1-13
Hong Kong HK 36/40/44/48/52/56/60/64/149/153/157/161/165 1-11 1-11
Hungary HU 36/40/44/48 1-13 1-13
Iceland IS 36/40/44/48/52/56/60/64/100/104/108/1 12/116/120/124/128/132/ |1-13 1-13
136/140
India IN None 1-13 1-13
Indonesia ID None 1-13 1-13
Iran IR 149/153/157/161/165 1-13 1-13
Ireland IE 36/40/44/48/52/56/60/64/100/104/108/112/116/120/124/128/132/ |1-13 1-13
136/140
Israel IL None 5-7 5-7
Italy IT 36/40/44/48/52/56/60/64/100/104/108/112/116/120/124/128/132/ |1-13 1-13
136/140
Jordan JO None 1-13 1-13
Kazakhstan KZ None 1-13 1-13
Korea (North) |KP 149/153/157/161 1-13 1-13
Korea ROC KR 149/153/157/161 1-13 1-13
(south)
Kuwait KW None 1-13 1-13
Latvia LV None 1-13 1-13
Lebanon LB None 1-13 1-13
28
ExtremeWare 7.3.1b3 Release Notes
Channel Mapping
Table 9: Altitude 300-21 channel mapping (continued)
Country 802.11g (802.11b
Country Code 802.11a Channels Channels |Channels
Liechtenstein {LI 36/40/44/48/52/56/60/64 1-13 1-13
Lithuania LT 36/40/44/48/52/56/60/64/100/104/108/1 12/116/120/124/128/132/ |1-13 1-13
136/140
Luxembourg |LU 36/40/44/48/52/56/60/64/100/104/108/1 12/116/120/124/128/132/ |1-13 1-13
136/140
Macau MO 36/40/44/48/52/56/60/64/149/153/157/161/165 1-13 1-13
Macedonia MK None 1-13 1-13
Malaysia MY None None 1-13
Mexico MX 36/40/44/48/52/56/60/64/149/153/157/161 1-11 1-11
Monaco MC 36/40/44/48/52/56/60/64 1-13 1-13
Morocco MA None 1-13 1-13
Netherlands NL 36/40/44/48/52/56/60/64/100/104/108/1 12/116/120/124/128/132/ |1-13 1-13
136/140
Norway NO 36/40/44/48/52/56/60/64/100/104/108/1 12/116/120/124/128/132/ |1-13 1-13
136/140
Oman OM None 1-13 1-13
Pakistan PK None 1-13 1-13
Panama PA 36/40/44/48/52/56/60/64/149/153/157/161/165 1-11 1-11
Peru PE 149/153/157/161/165 1-13 1-13
Philippines PH 36/40/44/48/52/56/60/64/149/153/157/161/165 1-13 1-13
Poland PL 36/40/44/48/52/56/60/64 1 00/104/1 08/1 12/1 16/120/124/128/132/ |1-13 1-13
136/140
Portugal PT 36/40/44/48/52/56/60/64 1 00/104/1 08/1 12/1 16/120/124/128/132/ |1-13 1-13
136/140
Puerto Rico PR 36/40/44/48/52/56/60/64/149/153/157/161/165 1-11 1-11
Qatar QA None 1-13 1-13
Romania RO None 1-13 1-13
Russia RU None 1-13 1-13
Saudi Arabia |SA None 1-13 1-13
Singapore SG 36/40/44/48/1 49/153/157/161/165 1-13 1-13
Slovakia SK 36/40/44/48/52/56/60/64 1-13 1-13
Republic
Slovenia 36/40/44/48/52/56/60/64/100/104/108/1 12/116/120/124/128/132/ |1-13 1-13
136/140
South Africa |ZA 36/40/44/48/52/56/60/64/100/104/108/1 12/116/120/124/128/132/ |1-13 1-13
136/140
Spain SP 36/40/44/48/52/56/60/64/100/104/108/1 12/116/120/124/128/132/ |1-13 1-13
136/140
Sweden SE 36/40/44/48/52/56/60/64/100/104/108/1 12/116/120/124/128/132/ |1-13 1-13
136/140
Switzerland CH 36/40/44/48/52/56/60/64 1-13 1-13
Syria SY None 1-13 1-13
Thailand TH 149/153/157/161 1-13 1-13
ExtremeWare 7.3.1b3 Release Notes 29
Overview
Table 9: Altitude 300-21 channel mapping (continued)
Country 802.11g (802.11b
Country Code 802.11a Channels Channels |Channels
Trinidad y TT 36/40/44/48/52/56/60/64 1-13 1-13
Tobago
Tunisia TN 36/40/44/48/52/56/60/64 1-13 1-13
Turkey TR 36/40/44/48/52/56/60/64 1-13 1-13
Ukraine UA None 1-13 1-13
United Arabo JAE None 1-13 1-13
Emirates
United GB 36/40/44/48/52/56/60/64/100/104/108/112/116/120/124/128/132/ |1-13 1-13
Kingdom 136/140
Uruguay UY 149/153/157/161 1-13 1-13
Uzbekistan UZ None 1-13 1-13
Venezuela VE 149/153/157/161 None 1-13
Vietnam VN None 1-13 1-13
Yemen YE None 1-13 1-13
Zimbabwe ZW None 1-13 1-13
New Zealand |NZ 36/40/44/48/52/56/60/64/1 49/153/157/161/165 1-13 1-13
Table 10 lists the channel mapping for indoor Altitude 300-2d wireless ports connected to an Alpine
3800 switch using ExtremeWare 7.3.
Table 10: Altitude 300-2d indoor channel mapping
Country 802.119 802.11b
Country Code 802.11a Channels Channels |Channels
Canada CA 52/56/60/64/149/153/157/161/165 1-11 1-11
United States |US 52/56/60/64/149/153/157/161/165 1-11 1-11
Japan JP 34/38/42/46 1-13 1-14
Taiwan TW 56/60/64/149/153/157/161 1-11 1-11
Albania AL None 1-13 1-13
Algeria DZ None 1-13 1-133
Argentina AR 56/60/64 None 1-13
Armenia AM 36/40/44/48/52/56/60/64 1-13 1-13
Australia AU 52/56/60/64/1 49/153/157/161 1-13 1-13
Austria AT 36/40/44/48 1-13 1-13
Azerbaijan AZ 36/40/44/48/52/56/60/64 1-13 1-13
Bahrain BH None 1-13 1-13
Belarus BY None 1-13 1-13
Belgium BE 36/40/44/48 1-13 1-13
Belize BZ 149/153/157/161/165 1-13 1-13
Bolivia BO 149/153/157/161/165 1-13 1-13
Brazil BR 36/40/44/48/52/56/60/64/100/104/108/1 12/1 16/120/124/128/ |1-11 1-11
132/136/140/149/153/157/161/165
30 ExtremeWare 7.3.1b3 Release Notes
Table 10: Altitude 300-2d indoor channel mapping (continued)
Channel Mapping
Country 802.119 802.11b
Country Code 802.11a Channels Channels /Channels
Brunei BN 149/153/157/161/165 1-13 1-13
Darussalam
Bulgaria BG 36/40/44/48/52/56/60/64/100/104/108/1 12/116/120/124/128/ |1-13 1-13
132/136/140
Chile CL 149/153/157/161/165 1-13 1-13
China CN 149/153/157/161/165 1-13 1-13
Colombia CO 36/40/44/46/52/56/60/64/149/153/157/161/165 1-11 1-11
Costa Rica CR None 1-13 1-13
Croatia HR 36/40/44/46/52/56/60/64 1-13 1-13
Cyprus CY 36/40/44/48/52/56/60/64/100/104/108/1 12/116/120/124/128/ |1-13 1-13
132/136/140
Czech CZ 36/40/44/48/52/56/60/64 1-13 1-13
Republic
Denmark DK 36/40/44/48/52/56/60/64/100/104/108/1 12/116/120/124/128/ |1-13 1-13
132/136/140
Dominican DO 36/40/44/48/52/56/60/64/149/153/157/161/165 1-11 1-11
Republic
Ecuador EC None None 1-13
Egypt EG None 1-13 1-13
El Salvador SV None 1-13 1-13
Estonia EE 36/40/44/48/52/56/60/64/100/104/108/1 12/116/120/124/128/ |1-13 1-13
132/136/140
Finland Fl 36/40/44/48/52/56/60/64/100/104/108/1 12/116/120/124/128/ |1-13 1-13
132/136/140
France FR 36/40/44/48/52/56/60/64 1-13 1-13
Georgia GE 36/40/44/48/52/56/60/64 1-13 1-13
Germany DE 36/40/44/48/52/56/60/64/100/104/108/1 12/116/120/124/128/ |1-13 1-13
132/136/140
Greece GR None 1-13 1-13
Guatamala GT 36/40/44/48/52/56/60/64/149/153/157/161/165 1-11 1-11
Honduras HN None 1-13 1-13
Hong Kong HK 52/56/60/64/1 49/153/157/161/165 1-11 1-11
Hungary HU 36/40/44/48 1-13 1-13
Iceland IS 36/40/44/48/52/56/60/64/100/104/108/1 12/116/120/124/128/ |1-13 1-13
132/136/140
India IN None 1-13 1-13
Indonesia ID None 1-13 1-13
Iran IR 149/153/157/161/165 1-13 1-13
Ireland IE 36/40/44/48/52/56/60/64/100/104/108/1 12/116/120/124/128/ |1-13 1-13
132/136/140
Israel IL None 5-7 5-7
Italy IT 36/40/44/48/52/56/60/64/100/104/108/1 12/116/120/124/128/ |1-13 1-13
132/136/140
Jordan JO None 1-13 1-13
ExtremeWare 7.3.1b3 Release Notes
31
Overview
Table 10: Altitude 300-2d indoor channel mapping (continued)
Country 802.11g 802.11b
Country Code 802.11a Channels Channels /Channels
Kazakhstan KZ None 1-13 1-13
Korea (North) {KP 149/153/157/161 1-13 1-13
Korea ROC KR 149/153/157/161 1-13 1-13
(south)
Kuwait KW None 1-13 1-13
Latvia LV None 1-13 1-13
Lebanon LB None 1-13 1-13
Liechtenstein LI 36/40/44/48/52/56/60/64 1-13 1-13
Lithuania LT 36/40/44/48/52/56/60/64/100/104/108/112/116/120/124/128/ |1-13 1-13
132/136/140
Luxembourg LU 36/40/44/48/52/56/60/64/100/104/108/112/116/120/124/128/ |1-13 1-13
132/136/140
Macau MO 36/40/44/48/52/56/60/64/149/153/157/161/165 1-13 1-13
Macedonia MK None 1-13 1-13
Malaysia MY None None 1-13
Mexico MX 36/40/44/48/52/56/60/64/149/153/157/161 1-11 1-11
Monaco MC 36/40/44/48/52/56/60/64 1-13 1-13
Morocco MA None 1-13 1-13
Netherlands NL 36/40/44/48/52/56/60/64/100/104/108/112/116/120/124/128/ |1-13 1-13
132/136/140
Norway NO 36/40/44/48/52/56/60/64/100/104/108/1 12/116/120/124/128/ |1-13 1-13
132/136/140
Oman OM None 1-13 1-13
Pakistan PK None 1-13 1-13
Panama PA 36/40/44/48/52/56/60/64/1 49/153/157/161/165 1-113 1-11
Peru PE 149/153/157/161/165 1-13 1-13
Philippines PH 36/40/44/48/52/56/60/64/1 49/153/157/161/165 1-13 1-13
Poland PL 36/40/44/48/52/56/60/64/100/104/108/1 12/116/120/124/128/ |1-13 1-13
132/136/140
Portugal PT 36/40/44/48/52/56/60/64/100/104/108/1 12/116/120/124/128/ |1-13 1-13
132/136/140
Puerto Rico PR 36/40/44/48/52/56/60/64/1 49/153/157/161/165 1-11 1-11
Qatar QA None 1-13 1-13
Romania RO None 1-13 1-13
Russia RU None 1-13 1-13
Saudi Arabia SA None 1-13 1-13
Singapore SG 36/40/44/48/149/153/157/161/165 1-13 1-13
Slovakia SK 36/40/44/48/52/56/60/64 1-13 1-13
Republic
Slovenia 36/40/44/48/52/56/60/64/100/104/108/1 12/116/120/124/128/ |1-13 1-13
132/136/140
South Africa ZA 36/40/44/48/52/56/60/64/100/104/108/1 12/116/120/124/128/ |1-13 1-13
132/136/140
32
ExtremeWare 7.3.1b3 Release Notes
Table 10: Altitude 300-2d indoor channel mapping (continued)
Channel Mapping
Country 802.119 802.11b
Country Code 802.11a Channels Channels _ |Channels
Spain SP 36/40/44/48/52/56/60/64/100/104/108/1 12/116/120/124/128/ |1-13 1-13
132/136/140
Sweden SE 36/40/44/48/52/56/60/64/100/104/108/1 12/116/120/124/128/ |1-13 1-13
132/136/140
Switzerland CH 36/40/44/48/52/56/60/64 1-13 1-13
Syria SY None 1-13 1-13
Thailand TH 149/153/157/161 1-13 1-13
Trinidad y TT 36/40/44/48/52/56/60/64 1-13 1-13
Tobago
Tunisia TN 36/40/44/48/52/56/60/64 1-13 1-13
Turkey TR 36/40/44/48/52/56/60/64 1-13 1-13
Ukraine UA None 1-13 1-13
United Arab AE None 1-13 1-13
Emirates
United GB 36/40/44/48/52/56/60/64/100/104/108/1 12/116/120/124/128/ |1-13 1-13
Kingdom 132/136/140
Uruguay UY 149/153/157/161 1-13 1-13
Uzbekistan UZ None 1-13 1-13
Venezuela VE 149/153/157/161 None 1-13
Vietnam VN None 1-13 1-13
Yemen YE None 1-13 1-13
Zimbabwe ZW None 1-13 1-13
New Zealand |NZ 36/40/44/48/52/56/60/64/149/153/157/161/165 1-13 1-13
Table 11 lists the channel mapping for outdoor Altitude 300-2d wireless ports connected to an Alpine
3800 switch using ExtremeWare 7.3.
Table 11: Altitude 300-2d outdoor channel mapping
Country 802.11g 802.11b
Country Code 802.11a Channels Channels Channels
Canada CA 52/56/60/64/1 49/1 53/157/161/165 1-11 1-11
United States JUS 52/56/60/64/1 49/1 53/157/161/165 1-11 1-11
Japan JP None 1-13 1-14
Taiwan TW 149/153/157/161 1-11 1-11
Albania AL None 1-13 1-13
Algeria DZ None 1-13 1-133
Argentina AR 56/60/64 None 1-13
Armenia AM 36/40/44/48/52/56/60/64 1-13 1-13
Australia AU 52/56/60/64/1 49/153/157/161 1-13 1-13
Austria AT None 1-13 1-13
Azerbaijan AZ 36/40/44/48/52/56/60/64 1-13 1-13
Bahrain BH None 1-13 1-13
ExtremeWare 7.3.1b3 Release Notes
33
Overview
Table 11: Altitude 300-2d outdoor channel mapping (continued)
Country 802.11g 802.11b
Country Code 802.11a Channels Channels Channels
Belarus BY None 1-13 1-13
Belgium BE None 13 13
Belize BZ 149/153/157/161/165 1-13 1-13
Bolivia BO 149/153/157/161/165 1-13 1-13
Brazil BR 100/104/108/112/1 16/120/1 24/128/132/136/140/149/153/15 1-11 1-11
7/161/165
Brunei BN 149/153/157/161/165 1-13 1-13
Darussalam
Bulgaria BG 100/104/108/112/1 16/120/124/128/132/136/140 1-13 1-13
Chile CL None None None
China CN 149/153/157/161/165 1-13 1-13
Colombia CO 52/56/60/64/149/153/157/161/165 1-11 1-11
Costa Rica CR None 1-13 1-13
Croatia HR None 1-13 1-13
Cyprus CY 100/104/108/112/116/120/124/128/132/136/140 1-13 1-13
Czech Republic |CZ None 1-13 1-13
Denmark DK 100/104/108/112/1 16/120/124/128/132/136/140 1-13 1-13
Dominican DO 52/56/60/64/149/153/157/161/165 1-11 1-11
Republic
Ecuador EC None None 1-13
Egypt EG None 1-13 1-13
El Salvador SV None 1-13 1-13
Estonia EE 100/104/108/112/1 16/120/124/128/132/136/140 1-13 1-13
Finland Fl 100/104/108/112/1 16/120/124/128/132/136/140 1-13 1-13
France FR None 1-7 1-7
Georgia GE 36/40/44/48/52/56/60/64 1-13 1-13
Germany DE 100/104/108/112/1 16/120/124/128/132/136/140 1-13 1-13
Greece GR None None None
Guatamala GT 52/56/60/64/149/153/157/161/165 1-11 1-11
Honduras HN None 1-13 1-13
Hong Kong HK 52/56/60/64/149/153/157/161/165 1-11 1-11
Hungary HU None 1-13 1-13
Iceland IS 100/104/108/112/1 16/120/124/128/132/136/140 1-13 1-13
India IN None 1-13 1-13
Indonesia ID None 1-13 1-13
Iran IR 149/153/157/161/165 1-13 1-13
Ireland IE 100/104/108/112/116/120/124/128/132/136/140 1-13 1-13
Israel IL None 5-7 5-7
Italy IT 100/104/108/112/116/120/124/128/132/136/140 None None
Jordan JO None 1-13 1-13
Kazakhstan KZ None 1-13 1-13
34
ExtremeWare 7.3.1b3 Release Notes
Table 11: Altitude 300-2d outdoor channel mapping (continued)
Channel Mapping
Country 802.119 802.11b
Country Code 802.11a Channels Channels Channels
Korea (North) |KP 149/153/157/161 1-13 1-13
Korea ROC KR 149/153/157/161 1-13 1-13
(south)
Kuwait KW None 1-13 1-13
Latvia LV None 1-13 1-13
Lebanon LB None 1-13 1-13
Liechtenstein LI None 1-13 1-13
Lithuania LT 100/104/108/112/116/120/124/128/132/136/140 1-13 1-13
Luxembourg LU 100/104/108/112/116/120/124/128/132/136/140 1-13 1-13
Macau MO 52/56/60/64/149/153/157/161/165 1-13 1-13
Macedonia MK None 1-13 1-13
Malaysia MY None None 1-13
Mexico MX 149/153/157/161 None None
Morocco MA None 1-13 1-13
Netherlands NL 100/104/108/112/116/120/124/128/132/136/140 1-13 1-13
Norway NO 100/104/108/112/116/120/124/128/132/136/140 1-13 1-13
Oman OM None 1-13 1-13
Pakistan PK None 1-13 1-13
Panama PA 52/56/60/64/149/153/157/161/165 1-11 1-11
Peru PE 149/153/157/161/165 1-13 1-13
Philippines PH 52/56/60/64/149/153/157/161/165 1-13 1-13
Poland PL 100/104/108/112/116/120/124/128/132/136/140 1-13 1-13
Portugal PT 100/104/108/112/116/120/124/128/132/136/140 1-13 1-13
Puerto Rico PR 52/56/60/64/149/153/157/161/165 1-11 1-11
Qatar QA None 1-13 1-13
Romania RO None 1-13 1-13
Russia RU None 1-13 1-13
Saudi Arabia SA None 1-13 1-13
Singapore SG 36/40/44/48/149/153/157/161/165 1-13 1-13
Slovakia SK None 1-13 1-13
Republic
Slovenia 100/104/108/112/116/120/124/128/132/136/140 1-13 1-13
South Africa ZA 100/104/108/112/116/120/124/128/132/136/140 1-13 1-13
Spain SP 100/104/108/112/116/120/124/128/132/136/140 None None
Sweden SE 100/104/108/112/116/120/124/128/132/136/140 1-13 1-13
Switzerland CH None 1-13 1-13
Syria SY None 1-13 1-13
Thailand TH 149/153/157/161 1-13 1-13
Trinidad y TT 36/40/44/48/52/56/60/64 1-13 1-13
Tobago
Tunisia TN None 1-13 1-13
ExtremeWare 7.3.1b3 Release Notes
35
Overview
Table 11: Altitude 300-2d outdoor channel mapping (continued)
Country 802.119 802.11b
Country Code 802.11a Channels Channels Channels
Turkey TR None 1-13 1-13
Ukraine UA None 1-13 1-13
United Arab AE None 1-13 1-13
Emirates
United GB 100/104/108/1 12/1 16/120/124/128/132/136/140 1-13 1-13
Kingdom
Uruguay UY 149/153/157/161 1-13 1-13
Uzbekistan UZ None 1-13 1-13
Venezuela VE 149/153/157/161 None 1-13
Vietnam VN None 1-13 1-13
Yemen YE None 1-13 1-13
Zimbabwe ZW None 1-13 1-13
New Zealand NZ 52/56/60/64/1 49/1 53/157/161/165 1-13 1-13
Tested Third-Party Products
This section lists the third-party products tested for Alpine 3800 switches. The UAA features contained
in this section apply to Alpine 3800 switches only.
Tested NICs
The wireless NICs in Table 12, Table 13, Table 14, Table 15, and Table 16 are tested with the listed
software (or later) and authentication method.
Table 12: 802.11 a/b/g wireless NICs
NIC Driver os Third-Party Software |Authentication Method
Proxim A/B/G Gold 2421.7 W2K SP4 [Odyssey 2.2/Card PEAP/TLS/TTLS
2.3.0.75 winxp sp4 [Vility
NetGear WAG511 2.4.1.1.30 W2K SP4 [Odyssey 2.2/Card PEAP/TLS/TTLS
2.3.0.73 winxp sp4 [Vility
D-link DWL-AG650 Airpro |2.0.1.254 W2K SP4 [Odyssey 2.2/Card PEAP/TLS/TTLS
winxp sp4 [Vility PEAP/TLS/TTLS
D-link DWL-AG650 213.1 WinXP SP1 (Odyssey 2.2/Card PEAP/TLS
AirExpert AG660 Utility
3Com 3CRWE154A72 241.33 W2K SP4 [Odyssey 2.2/Card PEAP/TLS
winxp sp1_ [Vility
Linksys AG WPC55AG 2324 W2K SP4 [Odyssey 2.2 PEAP/TLS
WinXP SP1 PEAP/TLS
Cisco Air-CB21AG .0.0.305 Card Utility PEAP/TLS
36 ExtremeWare 7.3.1b3 Release Notes
Table 13: 802.11 a/b wireless NICs
Tested Third-Party Products
NIC Driver os Third-Party Software |Authentication Method
Linksys WPC51AB 2.0.1.254 W2K SP4 Odyssey 2.2 PEAP/TLS/TTLS
WinXP SP1 PEAP/TLS/TTLS
Orinoco Gold A/B 7.64.1.316 W2K SP4 Odyssey 2.2 PEAP/TLS/TTLS
WinXP SP1 PEAP/TLS/TTLS
Table 14: 802.11a wireless NICs
NIC Driver os Third-Party Software |Authentication Method
Cisco 11a-only Air-CB20A [3.4.19.0 W2K SP4 Odyssey 2.2 PEAP/TLS
WinXP SP1 PEAP/TLS
Table 15: 802.11b wireless NICs
NIC Driver os Third-Party Software |Authentication Method
Cisco Aironet350 b 8.1.6.0 W2K SP4 Odyssey 2.2 PEAP/TLS
WinXP SP1
Netgear MA401 b-only 2.0.2.0 W2K SP4 Odyssey 2.2/Card PEAP/TLS
Utility PEAP/TLS
Microsoft b card MN520 D-link 2.0.1.254 |W2K SP4 Odyssey 2.2 PEAP/TLS
WinXP SP1 PEAP/TLS
3Com 11b-only 2.1.1.3005 W2K SP4 Odyssey 2.2/Card PEAP/TLS
3CRWE60292B winxp sp4 [Vtllity PEAP/TLS/TTLS
Table 16: 802.11g wireless NICs
NIC Driver os Third-Party Software {Authentication Method
NetGear WG511 2.1.1.4 Odyssey 2.2 PEAP/TLS
Dell True Mobile 1300 3.20.23.0 Odyssey/Card Utility PEAP/TLS
Buffalo WLI-CB-G54 3.10.53.6 W2K SP4 Odyssey 2.2 PEAP/TLS/TTLS
WinXP SP1 PEAP/TLS/TTLS
Linksys WPC54G 3.20.21.0 WinXP SP1 Odyssey 2.2 PEAP/TLS/TTLS
D-link DWL G650Airplus 1.0.0.5 W2K SP4 Odyssey 2.2 PEAP/TLS/TTLS
WinXP SP1 PEAP/TLS/TTLS
D-Link 11g-only 2.1.3.1 W2K SP4 Odyssey 2.2 PEAP/TLS/TTLS
DW LG650-B2 WinXP SP1 PEAP/TLS/TTLS
Microsoft MN-720 3.20.26.0 W2K SP4 Odyssey 2.2 PEAP/TLS/TTLS
WinXP SP1 PEAP/TLS/TTLS
ExtremeWare 7.3.1b3 Release Notes
37
Overview
Table 17: 802.11g MiniPCl wireless NIC
NIC Driver os Third-Party Software |Third-Party Software
Broadcom 54G 3.20.23.0 Card Utility Odyssey 2.2
MaxPerformance
The wireless PCI cards in Table 18 are tested with the listed software (or later) and authentication
method.
Table 18: Wireless PCI cards
NIC Driver os Third-Party Software (Authentication Method
Linksys WMP54G 3.30.15.0 W2K SP4 Odyssey 2.2/Card PEAP/TLS/TTLS
Utility
NetGear WAG311 Tri-mode |2.4.0.72 W2K SP4 Odyssey 2.2/Card PEAP/TLS/TTLS
Utility
NetGear WG311 2.4.0.71 W2K SP4 Odyssey 2.2/Card PEAP/TLS/TTLS
Utility
WPA-Compliant Wireless NICs
The wireless NICs in Table 19, Table 20, and Table 21 are WPA-compliant.
A NOTE
WPA compliant wireless NICs support TKIP and AES with pre-shared and dynamic keys.
Table 19: Wireless tri-mode NICs
NIC Driver os Third-Party Software [Authentication Method
NetGear WAG511 2.3.0.73 W2K SP4 Odyssey 2.2 PEAP/TLS/TTLS
WinXP SP1
D-link DWL-AG650 AirExpert |1.2.0.1 W2K SP4 Odyssey 2.2 PEAP/TLS/TTLS
WinXP SP1
3Com 3CRWE154A72 2.4.1.33 W2K SP4 Odyssey 2.2 PEAP/TLS/TTLS
WinXP SP1
3Com 3CRPAG175 1.0.0.25 W2K SP4 Odyssey 2.2 PEAP/TLS/TTLS
WinXP SP1
Proxim A/B/G 2.4.2.1.7 |W2K SP4 Odyssey 2.2 PEAP/TLS/TTLS
WinXP SP1
D-Link AG660 2.1.3.1 W2K SP4 Odyssey 2.2 PEAP/TLS/TTLS
WinXP SP1
Linksys AG WPC55AG 2.3.2.4 W2K SP4 Odyssey 2.2 PEAP/TLS/TTLS
WinXP SP1
Cisco Air-CB21AG 1.0.0.305 |W2K SP4 Odyssey 2.2 PEAP/TLS
WinXP SP1
38
ExtremeWare 7.3.1b3 Release Notes
Table 20: Wireless 802.11g NICs (WPA compliant)
Tested Third-Party Products
NIC Driver os Third-Party Software /|Authentication Method
Buffalo WLI-CB-G54 3.10.53.6 W2K SP4 Odyssey 2.2 PEAP/TLS/TTLS
WinXP SP1
NetGear WG511T 3.0.0.43 Odyssey PEAP/TLS/TTLS
Linksys WPC54G 3.20.21.0 WinXP SP1 |Odyssey 2.2 PEAP/TLS/TTLS
D-Link DWL-G650-B2 1.0.0.5 W2K SP4 Odyssey 2.2 PEAP/TLS/TTLS
WinXP SP1
Microsoft MN-720 3.20.21.0 W2K SP4 Odyssey 2.2 PEAP/TLS/TTLS
WinXP SP1
Table 21: Wireless 802.11 a/b NICs (WPA compliant)
NIC Driver Os Third-Party Software Authentication Method
D-link AirPro AB650 2.4.0.73 W2K SP4 Odyssey 2.2 PEAP/TLS/TTLS
WinXP SP1
NetGear WAB501 2.4.0.71 W2K SP4 Odyssey 2.2 PEAP/TLS/TTLS
WinXP SP1
Avaya Platinum A/B 2.4.1.21 W2K SP4 Odyssey 2.2 PEAP/TLS/TTLS
WinXP SP1
Tested RADIUS Servers
These RADIUS servers are fully tested:
e Microsoft Internet Authentication Server
e Funk Steel Belted RADIUS Enterprise Edition 4.5
e Meeting House
e Free Radius
e InfoBlox RadiusONE
e Roving Planet
e Cisco ACS
Tested Third-Party Clients
These third-party clients are fully tested:
e Funk Odyssey 2.2
e MeetingHouse Data AEGIS 2.0.5
e Odyssey 3.00.0.937
ExtremeWare 7.3.1b3 Release Notes
39
Overview
Tested Laptops
These laptops are fully tested:
e IBM Thinkpad T40 (Intel Centrino-based 802.11b)
e IBM Thinkpad T41 (Intel Centrino-based 802.11b)
e Dell Latitude D800 (Intel Centrino-based 802.11b)
e HP/Compaq nx9010 (Broadcom 54G MaxPerformance MiniPCI)
e Fujitsu Lifebook N series (Broadcom 54G MaxPerformance MiniPCI)
e Sony PCG-K15
e Dell Latitude D600
Tested PDAs
These PDAs are fully tested:
e iPAQ H5550
e Dell Axim x3i
e HP Pocket PC 4155
Tested Tablets
These tablets are fully tested:
e NEC Tablet
Tested Scanner
The following scanner is fully tested:
e Intermec Scanner Model 700 Color-Pocket PC - 802.11b CF: Open Authentication/No encryption,
Shared /WEP, and Open/WEP
Tested IP Phones
These IP phones are fully tested:
e Symbol Netvision IP-Phone
Tested Embedded WNIC Modules
e Dell Truemobile 1200, 1300, 1350, 1450
e IBM Thinkpad T40p Trimode (Centrino card)
Tested Spectralink Supported Handsets
e Avaya 3606
e Spectralink Netlink 1640
40 ExtremeWare 7.3.1b3 Release Notes
Tested Spectralink Gateway
Netlink SVP Avaya Voice Priority Processor
Netlink SVP100 Gateway
Legacy IP Phones
These wired IP phones have been verified for PoE power up only:
Avaya 4610SW IP
Avaya 4620 IP New 03-016A/B
Avaya 4620SW IP
Super tex PD1 v1
Super PD+PS
TI PTB48540 CLO03ENG
3COM NJ105
3COM NJ220
3COM NJ200 Old
3COM NJ200 New
3COM NJ100 New
3COM NJ100 Old
3COM 3C10248B with 3CNJVOIPMOD-NBX
3COM 3C10248PE IP Phone
3COM 3C10226PE IP Phone
Avaya 4602SW IP Phone
Avaya 4620 IP Phone
Avaya 4630SW IP Phone
Polycom IP 300 With 2457-11077-002 Rev.X1
Polycom IP 500 With 2457-11077-002 Rev.X1
Polycom IP 600
Polycom Speaker IP 3500 with Cisco PIM
Polycom Speaker IP 3500 with IEEE
Linear CD671
3COM 655003403 PD with 3CNJVOIPMOD-NBX
Avaya 4602 IP Phone
Linear LTC42571S8 with 4257
Linear Edge PD
TPS2375 Eval Chip #22
TPS2375 Eval Chip #20
Siemens Optipoint 410 Standard FV
Tested Third-Party Products
ExtremeWare 7.3.1b3 Release Notes
4
Overview
e Siemens Optipoint 410 Entry FV
e Polycom SoundPoint IP LAN/Power Cable
Legacy Phones with Dongle
Cisco 7910
Cisco 7940
Cisco 7960
Cisco 7970
42
ExtremeWare 7.3.1b3 Release Notes
Upgrading to ExtremeWare 7.3
This chapter contains the following sections:
e Staying Current on page 43
e Upgrading ExtremeWare on page 43
e Downgrading Switches on page 49
Staying Current
If you are an Extreme Assist customer, the latest release and release notes are available after logging in
to the Tech Support web site:
http://www.extremenetworks.com/go/esupport.htm.
Upgrading ExtremeWare
You can only load ExtremeWare 7.0 (or later) on a switch running ExtremeWare 6.2.2b56 (or later). You
can only load ExtremeWare 6.2.2 on a switch running ExtremeWare 6.1.9 (or later). Table 22 lists the
BootROM required for each version of ExtremeWare.
Table 22: Required BootROM versions
ExtremeWare Version BootRom Version
ExtremeWare 7.3.0 and later BootROM 8.2 (or later)
ExtremeWare 7.1.1 through ExtremeWare 7.2.0 BootROM 8.1 (or later)
ExtremeWare 7.0.0 through ExtremeWare 7.1.0 BootROM 7.8 (or later)
ExtremeWare 6.2.2 through ExtremeWare 6.2.2 BootROM 7.8
ExtremeWare 6.1.8 through ExtremeWare 6.2.1 BootROM 7.2 (or later)
ExtremeWare 6.1 through ExtremeWare 6.1.7 BootROM 6.5
If your switch is running ExtremeWare 6.1.8 (or earlier), you must first upgrade to ExtremeWare 6.1.9,
then upgrade to ExtremeWare 6.2.2b56 (or later). Following are specific instructions on upgrading to,
and downgrading from, ExtremeWare 7.3 for Summit, Alpine, and BlackDiamond switches.
ExtremeWare 7.3.1b3 Release Notes 43
Upgrading to ExtremeWare 7.3
Upgrading Switches to ExtremeWare 7.3
To install ExtremeWare 7.3, you must:
Save the configuration to a TFTP server.
Upgrade the BootROM to Version 8.2 as described on page 45.
Upgrade to ExtremeWare 6.1.9 as described on page 45.
Upgrade to ExtremeWare 6.2.2b56 as described on page 45.
Upgrade to ExtremeWare 7.3 as described on page 46.
Upgrade T1, E1, or T3 Modules from a Release Prior to ExtremeWare 6.1.8b79 as described on
page 47.
7 Upgrade T1, E1, or T3 Modules from ExtremeWare 6.1.8b79 or Later as described on page 48.
8 Upgrade ATM, MPLS, ARM, or PoS modules as described on page 48.
O a AeA WO N me
If you have already installed ExtremeWare 6.1.9 through ExtremeWare 6.2.2b43, you can skip step 3. If
you have already installed ExtremeWare 6.2.2b56 through ExtremeWare 7.0.1, you can skip steps 3
and 4.
A NOTE
If you are also upgrading your BlackDiamond to MSM-3’s, see the MSM-3 Upgrade Note included with
your MSM-3.
A NOTE
The Alpine 3802 requires a different upgrade procedure, described on page 49.
Save the Current Configuration
Before upgrading ExtremeWare, save your configuration using the following steps. This preserves the
ability to downgrade should it become necessary.
1 If you are using the Network Login campus mode:
a Disable Network Login using the disable netlogin command to prevent users from
re-authenticating during the backup process.
b Use the clear netlogin state port command on all Network Login user ports, causing all
Network Login users to be unauthenticated and all client ports to move back to their respective
unauthenticated VLAN configuration.
c Use the show netlogin and show vlan commands to verify that all Network Login ports are in
the unauthenticated state and the client ports are members of their respective unauthenticated
VLANs.
2 If you are using ACLs and the CPU DoS protect feature, ensure that the CPU DoS protect filter
precedence follows the rules described in “CPU DoS Protect and ACL Precedence” on page 93. If
there is a precedence conflict, CPU DoS protect is not enabled.
3 Save the current configuration in both the primary and secondary configuration spaces using the
save configuration primary and save configuration secondary commands.
4 Configure the switch to use the primary image and the primary configuration using the use image
primary and use configuration primary commands.
44 ExtremeWare 7.3.1b3 Release Notes
Upgrading ExtremeWare
5 Verify that all of the above procedures were completed successfully with the show switch
command.
6 Upload the configuration to a TFIP server for safekeeping using the upload configuration
command.
Upgrade the BootROM to Version 8.2
Before you upgrade ExtremeWare, upgrade to BootROM 8.2 (BootROM 8.2 is compatible with all
ExtremeWare versions back to ExtremeWare 6.1.9):
1 Download the BootROM using the download bootrom [<host_name> | <ip_addr>]
<ngboot 82.bin_name> command.
2 Reboot the switch using the reboot command.
Upgrade to ExtremeWare 6.1.9
If you are running ExtremeWare 6.1.8 (or earlier), upgrade to ExtremeWare 6.1.9:
1 TFIP download ExtremeWare 6.1.9 to the primary image space using the download image primary
command.
A CAUTION
If you do not upgrade to ExtremeWare 6.1.9 before downloading ExtremeWare 6.2.2, the
ExtremeWare 6.2.2 download will fail, and the following message will be printed from the system:
ERROR: File too large
2 Reboot the switch using the reboot command. The previous configuration of the switch is
preserved.
3 Verify that the correct BootROM and ExtremeWare version are loaded using the show switch and
show version commands.
4 Check the log for configuration errors. Manually enter configurations that did not load.
5 If you configured Random Early Drop Probability in ExtremeWare 6.1.8 (or earlier), re-configure the
Random Early Drop Probability using the configure red drop-probability command.
6 Save the configuration to the primary space.
Upgrade to ExtremeWare 6.2.2b56
If you are running ExtremeWare 6.1.9 to ExtremeWare 6.2.2b43, upgrade to ExtremeWare 6.2.2b56 (you
can substitute ExtremeWare 6.2.2 builds 68, 108, 124, 134, and 156 for build 56):
1 TFIP download ExtremeWare 6.2.2b56 to the primary image space using the download image
primary command.
2 Reboot the switch using the reboot command. The previous configuration of the switch is
preserved.
ExtremeWare 7.3.1b3 Release Notes 45
Upgrading to ExtremeWare 7.3
A NOTE
ExtremeWare 6.2.2b56 (and later) stores 75 static log entries. Previous versions stored 100 entries.
To accommodate the new entry limit, ExtremeWare 6.2.2b56 clears the static log after your first
reboot. To preserve your static log entries, use the show log command and save the output.
3 Verify that the correct BootROM and ExtremeWare version are loaded using the show switch and
show version commands.
4 TFIP download the saved configuration, and answer y at the prompt to reboot the switch.
5 Check the log for configuration errors. Manually enter configurations that did not load.
6 Save the configuration.
Do not save to the secondary configuration space until you are certain a downgrade to the previous
image is not required.
A NOTE
After upgrading from ExtremeWare 6.1.9 to ExtremeWare 6.2.2, the IGMP snooping leave time-out
value will be changed from 10 seconds to 0. This results in an IGMP snooping membership entry
being removed immediately when an IGMP leave is received from a host.
This is good for an environment where only one host is connected. Use the configure igmp
snooping leave-timeout command to change the leave time-out value back to 10 seconds.
Upgrade to ExtremeWare 7.3
If you are running any software image from ExtremeWare 6.2.2b56 to ExtremeWare 7.2.0 (or later),
upgrade to ExtremeWare 7.3:
A NOTE
If you are upgrading a chassis with MSM64i’s to MSM-3’s, see the MSM-3 Upgrade Note included with
your MSM-3.
1 Upload the configuration to your TFIP server using the upload configuration command.
2 Clear your switch using the unconfigure switch all command, and enter y at the prompt to
reboot the switch. If you started the upgrade process with ExtremeWare 6.2.2b56 or later, you can
skip this step.
3 TFIP download ExtremeWare 7.3 to the primary image space using the download image primary
command.
4 Reboot the switch using the reboot command.
A NOTE
If you have Hitless Failover enabled on your MSM-3, you can use the hitless upgrade procedure.
5 Verify that the correct ExtremeWare version is loaded on the switch using the show switch
command.
6 TFIP download the configuration you saved in Step 1, and enter y at the prompt to reboot the
switch.
46 ExtremeWare 7.3.1b3 Release Notes
Upgrading ExtremeWare
A NOTE
If you are using EAPS and are upgrading from a version prior to ExtremeWare 6.2.2b134 or from
ExtremeWare 7.0, the default failtimer expiry action changes to sending an alert. This keeps your ring
from failing over when there is no break in the ring, such as in the event of a broadcast storm, busy
CPU, or misconfigured control VLAN. To change the failtimer expiry action to opening the secondary
port, especially if your EAPS traffic flows through switches that do not support EAPS, use the configure
eaps failtime expiry-action command.
7 Check the log for configuration errors. Manually enter configurations that did not load.
8 Save the new configuration to the primary space.
Do not save to the secondary configuration space until you are certain a downgrade to the previous
image is not required.
9 If you are upgrading a BlackDiamond switch, synchronize the BootROM, image, and configuration
across all installed MSM modules using the synchronize command. This command reboots the
synchronized modules.
You can ignore any diagnostics failure messages generated by the synchronization.
10 Reboot the switch using the reboot command.
11 If you are using the Network Login campus mode:
a Manually enable Network Login using the enable netlogin [web-based | dot1x] command.
b Verify that users are able to authenticate and successfully access network resources.
Upgrade T1, E1, or T3 Modules from a Release Prior to ExtremeWare 6.1.8b79
If you are using a T1, E1, or T3 module with an ExtremeWare release prior to 6.1.8b79 or a BootROM
prior to 2.8, upgrade the module to ExtremeWare 7.3:
1 TFIP download ExtremeWare 6.1.8b79 for the module using the download image slot primary
command.
A NOTE
T1, E1, and T3 modules must be using ExtremeWare 6.1.8b79 and BootROM 2.8 before upgrading
to ExtremeWare 7.3.
2 Configure the module to use the primary image with the use image primary slot command.
3 Reboot the module using the reboot slot command.
A NOTE
If you are upgrading multiple modules, skip step 3 until you have upgraded every module, then
reboot the switch instead of rebooting each slot.
4 Verify that the correct ExtremeWare is loaded using the show version command. You should see
output similar to the following:
BootROM: 251.251
Image: WM4T1l Version 6.1.8 (Build 79)
If you see a version other than Build 79, repeat steps 1 - 4.
ExtremeWare 7.3.1b3 Release Notes 47
Upgrading to ExtremeWare 7.3
5 Download the BootROM using the download bootrom slot command.
6 Reboot the module using the reboot slot command.
A NOTE
If you are upgrading multiple modules, skip step 6, upgrade every module, then reboot the switch.
7 Download the latest ExtremeWare to the primary image space.
8 Reboot the module using the reboot slot command.
Upgrade T1, E1, or T3 Modules from ExtremeWare 6.1.8b79 or Later
If you are using a T1, E1, or T3 module with ExtremeWare 6.1.8b79 (or later) and BootROM 2.8 (or
later), upgrade the module to ExtremeWare 7.3:
1 TFIP download the latest ExtremeWare for the module using the download image slot primary
command.
2 Configure the module to use the primary image with the use image primary slot command.
3 Reboot the module using the reboot slot command.
Upgrade ATM, MPLS, ARM, or PoS Modules from a Release Prior to ExtremeWare 7.3
If you are using an ATM, MPLS, ARM, or PoS module with a previous ExtremeWare release or a
BootROM prior to 1.18, upgrade the module to ExtremeWare 7.3:
1 Upgrade your switch to ExtremeWare 7.3 by following the upgrade instructions “Upgrading
Switches to ExtremeWare 7.3” on page 44. When your switch is successfully booted on ExtremeWare
7.3.0 continue with step #2.
2 TFIP download ExtremeWare 7.3 for the module using the download image slot primary command.
Configure the module to use the primary image with the use image primary slot command.
Reboot the module using the reboot slot command.
A NOTE
If you are upgrading multiple modules, skip step 4 until you have upgraded every module, then reboot
the switch instead of rebooting each slot.
5 Verify that the correct ExtremeWare is loaded using the show version command.
6 Download the BootROM using the download bootrom slot command.
7 Reboot the module using the reboot slot command.
A NOTE
If you are upgrading multiple modules, skip step 7, upgrade every module, then reboot the switch.
8 Verify the slot is operational using the show slot <#> command.
48 ExtremeWare 7.3.1b3 Release Notes
Downgrading Switches
Upgrading an Alpine 3802 to ExtremeWare 7.3
To upgrade an Alpine 3802 to ExtremeWare 7.3:
1 Upload the configuration to your TFIP server using the upload configuration command.
2 Upgrade to BootROM 8.2 using the download bootrom command.
3 Reboot the switch using the reboot command.
4
If you are using an image prior to ExtremeWare 6.1.8b79, TFTP download ExtremeWare 6.1.8w3.0.1
b79 to the primary image space using the download image primary command.
5 Verify that the correct BootROM and ExtremeWare versions are loaded on the switch using the show
switch and show version commands.
6 Answer y at the prompt to reboot the switch.
7 TFIP download ExtremeWare 7.0.0b46 to the primary image space using the download image
primary command.
8 Reboot the switch using the reboot command.
9 TFIP download the latest ExtremeWare 7.3 build to the primary image space using the download
image primary command.
10 Reboot the switch using the reboot command.
11 TFTP download the configuration you saved in Step 1, and enter y to reboot the switch.
12 Check the log for configuration errors. Manually enter configurations that did not load.
13 Save the new configuration to the primary space.
Do not save to the secondary configuration space until you are certain a downgrade to the previous
image is not required.
Downgrading Switches
Assuming that the previous configuration is in the secondary configuration space and the previous
image is in the secondary image space:
1 If you saved an ExtremeWare 6.1 (or earlier) configuration during the upgrade process, configure the
switch to use that configuration with the use configuration secondary command.
If you did not save an earlier configuration, re-configure the switch or download a configuration at
the end of this process.
2 If you did not save the earlier ExtremeWare image in the secondary image space, download the
image using the download image secondary command.
A NOTE
If you downgrade to an ExtremeWare version that does not support software signatures
(ExtremeWare 6.2.2b56 or later supports software signatures), you must follow the upgrade
procedures in the preceding sections to get back to ExtremeWare 7.3. You cannot switch between
primary and secondary images on the switch unless they both support software signatures.
3 Use the image in the secondary image space with the use image secondary command.
4 Verify that the above procedures were completed successfully with the show switch command.
ExtremeWare 7.3.1b3 Release Notes 49
Upgrading to ExtremeWare 7.3
5 Downgrade to the appropriate BootROM version. The show version command displays the
BootROM version as “Unknown” when the BootROM is downgraded.
6 Reboot the switch.
A NOTE
When downgrading to a previous version of ExtremeWare, ensure that the switch configuration
matches that version of ExtremeWare or below. Pointing the configuration to a new version of
ExtremeWare and using a previous version of ExtremeWare is not supported. You will get a warning
message from the system when attempting to do so.
7 If you did not save an ExtremeWare 6.1 (or earlier) configuration during the upgrade process,
re-configure the switch or download a configuration.
50 ExtremeWare 7.3.1b3 Release Notes
Supported Limits
This chapter summarizes the supported limits in ExtremeWare 7.3.
Supported Limits
The table below summarizes tested metrics for a variety of features. These limits may change but
represent the current status. The contents of this table supersede any values mentioned in the
ExtremeWare 7.3 Software User Guide.
Table 23: Supported limits
Metric Description Limit
Access List rules Maximum number of Access Lists (best case). 5120
Access List rules—BlackDiamond Maximum number of BlackDiamond 6816 Access | 3500
6816 Lists (best case).
Access List rules—Summit Maximum number of Access Lists in which all 255
rules utilize all available options (worst case).
Access List rules—Alpine Maximum number of Access Lists in which all 255
rules utilize all available options (worst case).
Access List rules—BlackDiamond
Maximum number of Access Lists in which all
rules utilize all available options (worst case).
255 per I/O module
contained in the BGP route table (best case).
Access Profiles Maximum number of access profiles per switch. 128
Access Profile entries Maximum number of access profile entries per 256
switch.
Application Examination rules Maximum number of Application Examination 1000
rules.
Application Examination rules/port | Maximum number of Application Examination 60
rules per port.
BGP—Peer Groups Maximum number of BGP peer groups per 16
switch.
BGP—peers Maximum number of BGP peers per switch. 200
BGP—routes, MSM-3 Maximum number of routes received and 835,000
contained in the BGP route table (best case).
BGP—routes, MSM64i Maximum number of routes received and 300,500
ExtremeWare 7.3.1b3 Release Notes
51
Supported Limits
Table 23: Supported limits (continued)
Metric Description Limit
BGP—routes, Alpine Maximum number of routes received and 335,000
contained in the BGP route table (best case).
BGP—routes, Summit7i Maximum number of routes received and 410,000
contained in the BGP route table (best case).
BGP—routes, Summit48i Maximum number of routes received and 100,000
contained in the BGP route table (best case).
BGP—routes, Summit5i Maximum number of routes received and 80,800
contained in the BGP route table (best case).
BGP—NLRI filters Maximum number of NLRI filters per switch. 128
BGP—NLRI filer add entries Maximum number of NLRI add entries per switch. | 256
BGP—AS-Path filters Maximum number of AS-Path filters per switch. 128
BGP—AS-Path filter add entries Maximum number of AS-Path filter add entries 256
per switch.
BGP—network statements Maximum number of network statements per 256
switch.
BGP—aggregate addresses Maximum number of aggregate routes that can 256
be originated per switch.
Jumbo Frame size Maximum size supported for Jumbo frames, 9216
including the CRC.
EAPS—Domains/switch Maximum number of EAPS domains. 64
EAPS—Domains/ring Maximum number of EAPS domains if no switch | 64
in the ring is connected to another ring.
EAPS—VLAN links Maximum number of Control or Protected VLANs | 4093
per EAPS domain.
EAPS—Bridge links Maximum number of EAPS bridge links per 8192
switch.
EAPS—Bridge links Maximum number of EAPS bridge links on 8192
switches with 256MB memory.
EAPS—Bridge links Maximum number of EAPS bridge links on 4096
switches with 128MB memory.
EAPS—Master nodes Number of Master nodes per EAPS domain. 1
EAPS—Switches Maximum number of EAPS switches per ring. No limit
EMISTP & PVST+ — maximum Maximum number of EMISTP and PVST+ 128
domains, Summit domains.
EMISTP & PVST+ — maximum Maximum number of EMISTP and PVST+ 256
domains, Alpine domains.
EMISTP & PVST+ — maximum Maximum number of EMISTP and PVST+ 512
domains, BlackDiamond domains.
EMISTP & PVST+ — maximum Maximum number of EMISTP and PVST+ ports. 3840
ports
EMISTP & PVST+ — maximum Maximum number of EMISTP and PVST+ 128
domains per port, Summit domains that can be configured per port.
EMISTP & PVST+ — maximum Maximum number of EMISTP and PVST+ 256
domains per port, Alpine domains that can be configured per port.
EMISTP & PVST+ — maximum Maximum number of EMISTP and PVST+ 512
domains per port, BlackDiamond domains that can be configured per port.
ESRP—maximum domains Maximum number of ESRP domains for a single |64
switch.
52
ExtremeWare 7.3.1b3 Release Notes
Table 23: Supported limits (continued)
Supported Limits
Metric Description Limit
ESRP—maximum instances Maximum number of ESRP supported VLANs for | 64
a single switch.
ESRP—maximum ESRP groups Maximum number of ESRP groups within a 4
broadcast domain.
ESRP—maximum ESRP groups Maximum number of ESRP groups within a 3
with bi-directional rate shaping
broadcast domain when bi-directional rate
shaping is enabled.
ESRP—maximum VLANs in a
single ESRP domain — Summit,
Alpine
Maximum number of VLANs that can be joined to
a single ESRP instance through an ESRP
domain.
256 recommended;
3000 max
ESRP—number of VLANs in a
Maximum number of VLANs that can be joined to
1024 recommended;
Summitti, Summit48i, Summit48si,
Alpine 3802
routes for the Summit1i, Summit48i, Summit48si,
and Alpine 3802.
single ESRP domain, a single ESRP instance through an ESRP 3000 max
BlackDiamond domain.
ESRP—Route-track entries, Maximum number of routes that can be tracked 4
Summit, Alpine, BlackDiamond for each ESRP domain.
ESRP—maximum VLAN tracks Maximum numbers of VLAN tracks per VLAN. 1
FDB—maximum ports for Maximum number of ports supported for 2000
permanent entries permanent FDB entries.
FDB—maximum L2/L3 entries — Maximum number of MAC addresses/IP host 262,144
BlackDiamond, Summit5i, routes for the MSM64i, Summit5i, Summit7i,
Summit7i, Alpine 3804, Alpine Alpine 3804, and Alpine 3808.
3808
FDB—maximum L2/L3 entries — Maximum number of MAC addresses/IP host 131,072
Flow Redirection—maximum
Maximum number of rules that can point to the
64 (8 servers is the
(RIP and SAP)
SAP entries.
redirection rules same or separate groups of web cache servers. maximum)
Flow Redirection—maximum Maximum number of active entries for 64,000
enumeration mode entries enumeration mode rules. For example, one /16
rule can take all of the available entries.
Flow Redirection—maximum Maximum number of active entries for subnet 64
subnet mode entries mode rules. Each mask can have 1 entry.
IP ARP entries Maximum number of IPARP entries. 20,480
IP ARP Static entries Maximum number of permanent IP static ARP 512
entries supported.
IP ARP Static Proxy entries Maximum number of permanent IP ARP proxy 512
entries.
IP Route Sharing Entries Maximum number of static or OSPF routes used | 12
(ECMP)—static or OSPF in route sharing calculations.
IP Route Sharing Entries Maximum number of IS-IS routes used in route 8
(ECMP)—IS-IS sharing calculations.
IP Router interfaces Maximum number of VLANs performing IP routing | 512
- excludes SubVLANs.
IP Static Routes Maximum number of permanent IP routes. 1024
IPX Static Routes and Services Maximum number of static IPX RIP route and IPX | 64 for each
IPX dynamic routes and services
Maximum recommended number of dynamically
learned IPX RIP routes and SAP entries.
2000 for each
IPX Router interfaces
Maximum number of IPX router interfaces.
256
ExtremeWare 7.3.1b3 Release Notes
53
Supported Limits
Table 23: Supported limits (continued)
Metric
Description
Limit
IPX Access control lists
Maximum number of Access Lists in which all
rules utilize all available options.
worst case: 255
IS-IS—maximum routing interfaces | Maximum IS-IS routing interfaces. 255
IS-IS—maximum routes Maximum IS-IS routes. 25,000
IS-IS—maximum adjacencies Maximum IS-IS adjacencies per routing interface. | 64
IS-IS—maximum domain summary | Maximum IS-IS domain summary addresses. 32
addresses
IS-[S—maximum redistributed Maximum IS-IS redistributed routes using the 20,000
routes, regular metric regular metric.
IS-IS—maximum redistributed Maximum IS-IS redistributed routes using the 30,000
routes, wide metric wide metric.
IS-[S—maximum redistributed Maximum IS-IS redistributed routes using both 10,000
routes, both metrics metrics.
Logged Messages Maximum number of messages logged locally on | 20,000
the system.
MAC-based VLANs—MAC Maximum number of MAC addresses that can be | 7000
addresses downloaded to the switch when using MAC-based
VLANs.
MAC-based security Maximum number of MAC-based security 1024
policies.
Mirroring—mirrored ports Maximum number of ports that can be mirrored to | 8
the mirror port.
Mirroring—number of VLANs Maximum number of VLANs that can be mirrored | 8
to the mirror port.
NAT—maximum connections Maximum number of simultaneous connections 256,000
per switch.
NAT—maximum rules Maximum number of rules per switch. 2048
NAT—maximum VLANs
Maximum number of inside or outside VLANs per
switch.
The switch’s limit
switch.
NetFlow—Filters Maximum number of NetFlow filters in a switch. 128
NetFlow—Groups Maximum number of NetFlow groups. 32
NetFlow—Hosts Maximum number of NetFlow hosts. 8/group
Network Login—Maximum clients Maximum number of Network Login clients per 1024
Network Login—802.1x
Maximum recommended Session-Timeout value
returned by RADIUS server.
7200 seconds
routes—BlackDiamond, Summit7i,
Alpine
routes contained in an OSPF LSDB of an ABR
router in the OSPF domain.
OSPF areas As an ABR, how many OSPF areas are 8
supported within the same switch.
OSPF external Recommended maximum number of external 100,000
routes—BlackDiamond, Summit7i, routes contained in an OSPF LSDB of an internal
Alpine router in the OSPF domain.
OSPF intra-area Recommended maximum number of intra-area 8800
routes—BlackDiamond, Summit7i, routes contained in an OSPF LSDB of an ABR
Alpine router in the OSPF domain.
OSPF inter-area Recommended maximum number of inter-area 16,000
54
ExtremeWare 7.3.1b3 Release Notes
Table 23: Supported limits (continued)
Supported Limits
Metric Description Limit
OSPF external routes—Summitti, Recommended maximum number of external 27,000
Summit5i, Summit48i, Summit48si | routes contained in an OSPF LSDB of an internal
router in the OSPF domain.
OSPF intra-area routes—Summit1i, | Recommended maximum number of intra-area 2000
Summit5i, Summit48i, Summit48si | routes contained in an OSPF LSDB of an ABR
router in the OSPF domain.
OSPF inter-area routes—Summit1i, | Recommended maximum number of inter-area 8000
Summit5i, Summit48i, Summit48si | routes contained in an OSPF LSDB of an ABR
router in the OSPF domain.
OSPF routers in a single area Recommended maximum number of routers ina _ | 200
single OSPF area.
OSPF interfaces on a single router | Recommended maximum number of OSPF 384
routed interfaces on a switch.
OSPF virtual links Maximum number of OSPF virtual links 32
supported.
OSPF adjacencies—Summit1i, Maximum number of OSPF adjacencies on a 150
Summit5i, Summit48i, Summit48si | switch with 128 MB memory.
OSPF adjacencies—Summit7i, Maximum number of OSPF adjacencies on a 225
Alpine, BlackDiamond switch with 256 MB memory.
RIP-learned routes Maximum number of RIP routes supported 8000
without aggregation.
RIP interfaces on a single router Recommended maximum number of RIP routed 384
interfaces on a switch.
Route Maps Maximum number of route maps supported ona | 128
switch.
Route Map Entries Maximum number of route map entries supported | 256
on a switch.
Route Map Statements Maximum number of route map statements 512
supported on a switch.
SLB—maximum number of For Transparent and Translational and GoGo 500,000/500,000/
simultaneous sessions modes respectively. unlimited
SLB—maximum number of VIPs
For Transparent and Translational and GoGo
modes respectively.
1000/1000/unlimited
SLB—maximum number of Pools For Transparent and Translational (does not 256/256
apply to GoGo mode)
SLB—maximum number of Nodes | For Transparent and Translational (does not 256/256
per Pool apply to GoGo mode)
SLB—maximum number of Applies to GoGo mode only; a group shares any |8
physical servers per group number of common VIPs.
SSH2—number of sessions Maximum number of simultaneous SSH2 8
sessions.
SNMP—Trap receivers Maximum number of SNMP trap receiver stations | 16
supported.
SNMPv3—Users Maximum number of SNMPv3 users. 32
SNMPv3—Groups Maximum number of SNMPv3 groups. 64
SNMPv3—Accesses Maximum number of SNMPv3 accesses. 128
SNMPv3—MIB-views Maximum number of SNMPv3 MIB-views. 128
SNMPv3—Communities Maximum number of SNMPv3 communities. 64
ExtremeWare 7.3.1b3 Release Notes
55
Supported Limits
Table 23: Supported limits (continued)
Metric Description Limit
SNMPv3—Target addresses Maximum number of SNMPv3 target addresses. 16
SNMPv3—Target parameters Maximum number of SNMPv3 target parameters. | 16
SNMPv3—Notifications Maximum number of SNMPv3 notifications. 8
SNMPv3—Filter profiles Maximum number of SNMPv3 notify filter profiles. | 16
SNMPv3—Filters Maximum number of SNMPv3 notify filters. 400
Spanning Tree—maximum STPDs, | Maximum number of Spanning Tree Domains. 128
Summit
Spanning Tree—maximum STPDs, | Maximum number of Spanning Tree Domains. 256
Alpine
Spanning Tree—maximum STPDs, | Maximum number of Spanning Tree Domains. 512
BlackDiamond
Spanning Tree—minimum STPDs Minimum number of Spanning Tree Domains. 1
Spanning Tree—802.1d domains Maximum number of 802.1d domains per port. 1
Spanning Tree—number of ports Maximum number of ports that can participate in | 4096
a single Spanning Tree Domain.
Spanning Tree—minimum number
of ports
Minimum number of ports that can participate in a
single Spanning Tree Domain.
Spanning Tree—minimum number
of domains/port
Minimum number of Spanning Tree Domains that
can be configured per port.
1 for default VLAN, 0
for others
Spanning Tree—Spanning Tree
modes
Maximum number of Spanning Tree modes per
switch.
2 (dotid and dot1w)
protocol-sensitive filters
filters in the switch.
Standard Multinetting—Maximum Maximum secondary IP addresses that can be 64
secondary IP addresses per switch | configured per switch.
Standard Multinetting—Maximum Maximum secondary IP addresses that can be 64
secondary IP addresses per VLAN | configured per VLAN.
Static MAC FDB entries—Summit, | Maximum number of permanent MAC entries 4096
Alpine, BlackDiamond configured into the FDB.
Super-VLAN—number of ports & Maximum number of ports and sub-VLANs 2550
sub-VLANs associated with each super-VLAN.
Syslog servers Maximum number of simultaneous syslog servers | 4
that are supported.
Telnet—number of sessions Maximum number of simultaneous Telnet 8
sessions.
UDP profiles Number of profiles that can be created for UDP 10
forwarding.
UDP profile entries Number of entries within a single UDP profile. 16
VLANs—Summit, Alpine Includes all VLANs plus sub VLANs, super 4095
VLANs, etc.
VLANs—BlackDiamond 6816 fully Includes all VLANs plus sub VLANs, super 681
populated VLANs, etc.
VLANs—BlackDiamond 6816 with Includes all VLANs plus sub VLANs, super 1776
up to 7 I/O modules VLANs, etc.
VLANs—BlackDiamond Includes all VLANs plus sub VLANs, super 4095
VLANs, etc.
VLANs—maximum active The number of simultaneously active protocol 15
56
ExtremeWare 7.3.1b3 Release Notes
Table 23: Supported limits (continued)
Supported Limits
Metric Description Limit
VRRP—maximum VRIDs Maximum number of unique VRID numbers per 4
switch.
VRRP—maximum VRIDs with Maximum number of unique VRID numbers per 3
bi-directional rate shaping switch when bi-directional rate shaping is
enabled.
VRRP—maximum VLANs/switch Maximum number of VLANs per switch. 64
VRRP—maximum VRIDs/VLAN Maximum number of VRIDs per VLAN. 4
VRRP—maximum ping tracks Maximum number of ping tracks per VLAN. 4
VRRP—maximum iproute tracks Maximum number of iproute tracks per VLAN. 4
VRRP—maximum VLAN tracks Maximum number of VLAN tracks per VLAN. 1
ExtremeWare 7.3.1b3 Release Notes
57
Supported Limits
58
ExtremeWare 7.3.1b3 Release Notes
Clarifications, Known Behaviors, and
Resolved Issues
This chapter describes items needing further clarification, behaviors that might not be intuitive, and
issues that have been resolved since the last release. Numbers in parentheses are for internal reference
and can be ignored.
This chapter contains the following sections:
e Clarifications and Known Behaviors on page 59
e Issues Resolved in ExtremeWare 7.3.1b3 on page 104
e Issues Resolved in ExtremeWare 7.3.0b49 on page 105
e Issues Resolved in ExtremeWare 7.3.0b44 on page 107
Clarifications and Known Behaviors
Following are the clarifications and known behaviors in ExtremeWare 7.3. For changes made in
previous releases, see the release notes specific to the release.
General
HTTPS Access
HTTPS is only available on the Alpine switches (PD3-2489351).
Unable to Download Image to a Switch with 500 Configured IP VLANs
Reduce the number of configured IP VLANs to 400 on a switch with no management port. This would
allow you to download a new software image (PD3-3575589).
NP API Generates Error Messages When Disabling a Slot Containing an OC3 or OC12
Module
The NP API generates log error messages whenever you disable a slot that contains an OC3 or OC12
module. The same error messages are generated when you hot plug an OC3 and OC12 module. The
NPAPI can not reboot error message is continuos, occurring about every 5 (+/-) seconds, and will fill
up the log. You will also receive an oobPollTask error message about every 5 minutes (PD2-249436801).
ExtremeWare 7.3.1b3 Release Notes 59
Clarifications, Known Behaviors, and Resolved Issues
Cannot Ping localHost Loopback Interface
You cannot ping the localHost loopback interface (PD3-2791311).
Hot-swapping an MSM3 Causes Invalid MAC Address on Backplane EEPROM
When you hot-swap an MSM-3, the following log message is generated:
CRITICAL ERROR: Backplane EEPROM has invalid MAC Address. System halted
(PD3-1514691)
MSM-3 Displays Broken Connection Recovered Message when Hot-swapping and
Inserting an MSM64i
If you hot-swap and insert an MSM64i and have an MSM-3 installed, the MSM-3 generates the
following log messages:
<Crit:SYST> The broken connection between MSM-A mother board port 24 and I/O module
1 port 6 is recovered (PD3-1221174)
Hot-Swapping an MSM Causes I/O Modules to Reset
Hot-swapping an MSM generates the following log messages:
<Info:SYST> cardScan: <msm insert> Attempting to fix card 2 in reset <FFFFFFFF>.
<Info:SYST> cardScan: <msm insert> Attempting to fix card 4 in reset <FFFFFFFF>.
In the above message, card 2 and card 4 are not present; all of the other cards are present (PD3-1206991).
Downloaded Configuration Might Cause Syntax Error With Enable Web Command
A configuration file uploaded to a server, then downloaded to the switch, might cause a syntax error
when the switch reboots. The downloaded configuration file caused a syntax error when it reached the
entry, "enable web http access-profile none port 80" (PD3-3192200).
Wireless Error Messages Display During Bootup
If two APs are connected to the switch and are online when the switch is rebooted, the following error
messages are displayed during the reboot:
Jul 31 07:12:50 SYST: Invalid security profile with index 2
Jul 31 07:12:50 SYST: Port and interface binding not found
Jul 31 07:12:50 SYST: Request for req_type=WI_SECURITY_PROFILE: No such wireless
interface 3:1:1 (index=300101)
Jul 31 07:12:50 SYST: Request for req_type=WI_SECURITY_PROFILE: No such wireless
interface 3:1:2 (index=300102)
These messages only occur when no slot information is configured and do not impact switch
performance (PD3-3017484).
show pim snooping Command Shows an Incomplete List of Packets Snooped
The show pim snooping <vlan> command shows an incomplete list of the PIM control packets
snooped for the specified VLAN if you are sending more than 10 data streams. This is primary seen
with (S,G) entries (PD3-2721014).
60 ExtremeWare 7.3.1b3 Release Notes
Clarifications and Known Behaviors
MSM-Failover Link-Down Not Working on the Remote Side
The MSM-failover link-down does not bring down the link on the remote side of the switch. It only
brings down the link on the fiber ports (PD2-246448118).
ExtremeWare 7.3 introduces the concept of QoS profiles on a VLAN
QoS profiles refer to the queue configuration of physical ports. The standard way to configure QoS
profiles for ports is by using port numbers. If you configure a QoS profile on a VLAN, the QoS profile is
applied to all of the ports on the VLAN. However, if the port belongs to multiple VLANs, any QoS
profile changes made on the different VLANs affect the same physical port configuration. The QoS
profile changes correspond to the last configured value on the port. The configuration can be either
directly as a port or because of being a part of a VLAN (PD2-243742697).
Repeatedly Hot-Swapping the MSM Might Cause Loss of Connectivity
If you remove and re-insert the backup MSM several times in a row (above 5 times), you might
temporarily lose connectivity between the MSM and the I/O modules (PD2-231933106).
Cannot Save or Download a Configuration If a “ghost” Process is Running in the
Background
If you issue the save configuration command, you might get the following error message:
Failed to save config: a save or download is in progress - please try again Later
This error message can be generated if you are trying to save or download a configuration while the
switch already has a save or download configuration process running in the background. There are
instances where the switch appeared to have a “ghost” save or download configuration process running
but did not. This error message can be issued if a save or download configuration process was
interrupted.
Workaround. Reboot the switch. This should clear the ghost processes and allow you to save and
download the configuration again (PD2-231288723).
Creating an ACL with a Filter-Precedence of 11 or 12 Generates a Conflict Error with
cpu-dos-protect
When enabling cpu-dos-protect on the switch, a filter-precedence of 10 (default) is used. If you
configure another ACL with a filter-precedence of 11 and 12, a conflict error with CPU DOS Protection
is generated (PD2-241094151, PD2-241094160).
Hot-Swapping Modules Might Cause Misleading Error Messages
A module that is receiving broadcast traffic might generate misleading error messages as it is removed.
The messages will be similar to the following: <Erro:Bridge.FrameError> Cannot send
packet out.Card=7 not present 04/21/2004 21:15:00.17 (PD2-231933101).
G12Ti Module Link Detection Fails
Link detection will fail on G12Ti ports set to 100 Mbps full duplex, with autonegotiation set to off, if
you do not use the correct cabling. Auto cross detection does not properly detect this condition. As a
workaround, use the correct cable (PD2-232279701).
ExtremeWare 7.3.1b3 Release Notes 61
Clarifications, Known Behaviors, and Resolved Issues
Autonegotiation Between Fiber Optic Ports is not Possible
A port from a Fast Ethernet switch, when connected to any gigabit port, does not recognize the speed
mismatch. The port appears active even though the gigabit port is inactive (PD3-2073971).
show log Command Memory Error
When running debug-trace for AgentX-APi, the show log command output shows an AP failure due to
the switch being “out of memory,” even though it is not (PD3-2617791).
unconfigure switch all Command Should Not Restore the Downloaded Configuration
When downloading a new configuration to the switch, you are prompted with the following message:
New configuration file has been successfully downloaded to memory.
To make the new configuration ffective, th system needs to reboot.
Would you like to reboot the system? (Y/N)
If you choose n, the new configuration should not take effect. Issuing the unconfigure switch all
command should restore the switch to the factory defaults. However, instead of restoring the factory
defaults, the switch again applies the previously downloaded configuration (PD3-2536041).
WLANSYST Output of the show log Command is Not Correct
The output for the show log command always shows the WLANSYST message twice. This does not
impact switch performance (PD3-2450049).
System Related — All Systems
The NVRAM Dirty Bit Being Set from the PoE Code
The NVRAM dirty bit is being set from the PoE code that saves the connection history (PD3-2963230).
PoE Firmware image Download is not Available in Base Image
The PoE firmware image has been removed from the base image. The current base image will give an
error message if it detects a PoE module on an Alpine switch. For the PoE feature to work correctly, use
the unified (.xtr) image, not the base (.Bxtr) image (PD3-2011501).
Autonegotiation Setting Not Preserved on Added and Deleted Loopback Ports
If you add a 10/100 port as a loopback port and delete it, autonegotiation is set to off (PD2-192574401).
Configure Slot for PoE Before Configuring or Downloading PoE Configuration
You must configure a slot for a PoE module before downloading a PoE configuration. Downloading a
PoE configuration to a switch without a PoE module configured generates an error message similar to
the following:
Error: slot 8 is not PoE capable!
To avoid this, configure the slot for a PoE module before saving the configuration (PD2-209577118).
62 ExtremeWare 7.3.1b3 Release Notes
Clarifications and Known Behaviors
The show log Command Truncates Long Commands
If you download a configuration, the output of the show log command might not completely display
commands longer than 240 characters. This is a display problem; the configuration loads correctly
(PD2-171470611).
The show log Display Truncates Configuration Parsing
If you download a configuration and use the show log command to view the parsing of the
configuration, the log does not display the entire parsing. This is a display problem; the configuration
parses and loads correctly (PD2-171470601).
Do Not Create Single-Character Names
When you create named components such as VLAN or access group names, do not use single character
names. The single character might be interpreted by the switch as a truncated parameter. For example,
if you name an SNMPV3 access group “a” and delete that access group using the configure snmpv3
delete access a command, the switch might interpret the command as configure snmpv3 delete
access all-non-default (PD2-152594408).
Smart Redundancy Enabled in Saved Configuration
Smart redundancy is always enabled in a saved configuration. To work around this, disable smart
redundancy after downloading a configuration (PD2-128133503).
Microsoft Load Balancing
When using Microsoft load balancing, if you replace existing hardware and use the same IP address on
the new hardware (thus associating the same IP address with a new MAC address), IP traffic through
the IPFDB is not forwarded. To work around this, manually clear the IPFDB (PD2-124851229).
Telnet and the show ports Command
If you telnet to the switch and use the show ports info detail command, the line feeds might not be
recognized, resulting in output lines overwriting previous lines (PD2-130127501).
The show configuration Output
After using the unconfigure switch all command, the show configuration output displays the
VLAN default without any ports assigned. The ports still belong to the VLAN default, as the show vlan
output correctly displays (PD2-128233941).
Upgrading to ExtremeWare 7.0 and Bi-Directional Rate Shaping
When you directly upgrade from ExtremeWare 6.2.2 to ExtremeWare 7.0 (or later), bi-directional rate
shaping does not work if the loopback ports were in autonegotiation mode. This behavior is not
displayed by 10/100Base-T or Gigabit fiber ports. A workaround is to remove and re-add the loopback
ports to the VLAN (PD2-107820904).
Upgrading to ExtremeWare 7.0 and Debug-Trace
When you directly upgrade from ExtremeWare 6.2.2 to ExtremeWare 7.0 (or later), the debug-trace
configuration might change. Verify the debug-trace configuration, if any, after upgrading. Use the show
ExtremeWare 7.3.1b3 Release Notes 63
Clarifications, Known Behaviors, and Resolved Issues
debug-trace command to display the configuration. You can either re-configure manually, or download
the ExtremeWare 6.2.2 configuration instead of doing a direct upgrade (PD2-106733988).
Upgrading to ExtremeWare 7.0 and OSPF
If you upgrade directly from ExtremeWare 6.2.2 to ExtremeWare 7.0 (or later), the OSPF metric for 10
Gigabit interfaces is incorrect. A workaround is to manually configure the OSPF metrics, or to upload
the configuration before upgrading and then download the ExtremeWare 6.2.2 configuration
(PD2-108161623).
Blank Space in show port info detail Command Output
The output of the show port info detail command contains several blank pages. The output still
contains all of the requested information (PD2-107800978).
Using an ExtremeWare 7.0 Configuration with an Earlier Image
If you are using an ExtremeWare 7.0 (or later) configuration and attempt to use an earlier image, the
switch prompts you for confirmation (because this combination is not recommended). If you answer “n
at the prompt, you receive the following error message:
Error: bad image.
You can safely ignore this message (PD2-110983501).
Console Response with a Large Number of ARP Entries
Console response is slow when the switch is learning 10,000 or more ARP entries. This does not affect
performance. Console response returns to normal when the entries are learned (PD2-104103941).
The show log chronological Command
When the syslog contains more than 1,000 lines, the show log chronological command displays
nothing. However, the command show log displays correctly (PD2-104062736).
BOOTP-Dependent Routes in Downloaded Configuration not Created
Static and default routes that depend on a BOOTP IP address/subnet are not created when you
download a configuration (PD2-86888351).
The disable learning Command and Flooding
The disable learning command does not remove the port from the security flood list. Thus, you cannot
disable flooding when learning is disabled (PD2-73199618).
Port Tag Limitation
There is an absolute limit of 3552 port tags available in a system. The usage of these port tags depends
on a combination of factors:
e Installed ATM, MPLS, ARM, and PoS modules
e Mirroring
e IPX routing
64 ExtremeWare 7.3.1b3 Release Notes
Clarifications and Known Behaviors
e Static FDB entries
If the switch reaches the limit of available port tags, the following messages appear in the syslog:
<WARN:HW> tNetTask: Reached maximum otp index allocation
<WARN:HW> tBGTask: Reached maximum otp index allocation
If this occurs, you must compromise some features (for example, mirroring) in order to expand your use
of other functionality. (1-E5U7Y).
WinSCP2 Not Supported
The application WinSCP2.exe is not supported. Using WinSCP2 does not cause any problems
(1-A5C6C).
BlackDiamond
Secondary MSM Access Error
The following access error might be logged in the show diagnostics command output while the
secondary MSM is in the reset state after running the synchronize command:
07/14/2004 14:51:50.00 <Crit:ENG> ENG: trxdiag: Twister access on MSM-B failed
(tmp=31)
This does not affect switch performance and there is no need for any hardware replacement
(PD3-1437438, PD3-1437361).
Loopback Port Must be on Same Module on a BlackDiamond Switch
The loopback port must be on the same module as the rate shaped ports. Though you can configure a
loopback port on another module, this is still not a supported configuration. This applies to
BlackDiamond switches only (PD2-124299901).
Two Trap Messages Sent for Hard Reset/Soft Reset on BlackDiamond 6816
When performing a hard reset/soft reset on a BlackDiamond 6816 with SNMP traps configured, two
SNMF traps are sent. On the BlackDiamond 6816 this behavior occurs repeatedly with both MSM-A and
MSM-B having MSM3s (PD3-1135809).
Targeted LDP Sessions Become Operational When MPLS is Disabled
Issuing the command, show mpls ldp, might display operational targeted LDP sessions, even on
switches with MPLS disabled. The TLS tunnel VC state is displayed as “Complete” and the LSP state is
displayed as “Down.” No traffic traverses the tunnel. There is no workaround (PD2-229043816).
BGP Fast Fail-over Does Not Work for Change of IP Address
If a BGP session exists with fast-failover enabled and the connection has been established with large
keepalive and hold timer values, if you change the IP address, BGP will continue to stay in the
established state until the hold timer expires.
ExtremeWare 7.3.1b3 Release Notes 65
Clarifications, Known Behaviors, and Resolved Issues
Workaround. Do not allow IP address changes to be made to the VLAN transmitting BGP traffic
(PD2-238197001).
CMT Group Will Not Forward Traffic Without a Master Slot
When you create a cross-module trunk (CMT) group with the master slot missing or disabled, the group
will not forward traffic. A save and reboot will resolve the problem. If a working CMT group already
exists, and that group is disabled and re-enabled, the CMT group works correctly (PD2-175975513).
Connection to G12SXi Might be Lost
If you reboot a BlackDiamond, you might lose the connection between the MSM64i and a G12SxXi in slot
4 of a BlackDiamond 6804 or BlackDiamond 6808, or in slot 9 of a BlackDiamond 6816 (PD2-149449300).
Messages similar to the following are generated:
<CRIT:SYST> [2] The connection between MSM-A mother board and I/O module 4 is broken,
need to fix immediately
<INFO:SYST> Start initializing module in slot 4
<INFO:SYST> Generating default port configuration for slot 4 module oper type G12SXi
config type Unknown
To avoid this, install the G12SXi in a different slot, or use an MSM-3. To work around this, reboot the
switch again. For more details, see Field Notice FN 0147.
MPLS and ESRP
When a TLS VC is configured for an ESRP sub VLAN, the TLS VC is not deactivated when ESRP goes
into the slave state (PD2-85254107).
EAPS and Hitless Failover
If you have an EAPS domain with one MSM64i installed in the master switch and two MSM-3s installed
in the transit switch, the master switch enters the unknown state when you initiate hitless failover on
the transit switch (PD2-219743398).
Cross-Module Trunking and Hitless Failover
For traffic load-shared across I/O modules, failover is not hitless; traffic loss occurs for approximately
four seconds (PD2-186133901).
Autonegotiation Off Command Accepted on 10 Gigabit Ethernet Modules
Although you cannot disable autonegotiation on the 10 gigabit Ethernet modules, the command to turn
off autoneogtiation is accepted and the resulting display shows autonegotiation status as off
(PD2-223283401, PD2-232279703).
Memory Corruption with RRO on PATH Message
When the egressing switch receives an RSVP PATH message with a Record Route Object (RRO) from a
directly attached peer with the Session Attributes Flags set to Label Recording Requested, the switch
might crash. This can happen when the Session Attribute Flags field indicates Label Recording
Requested on a non-Extreme Networks switch (PD2-213821701).
66 ExtremeWare 7.3.1b3 Release Notes
Clarifications and Known Behaviors
Workaround. Disable the Label Recording Request on the non-Extreme Networks MPLS switch and
reboot.
No Longer Display Stale TLS NHLFE Entries
Using an LSP tunnel label that is no longer valid creates stale TLS NHLFE entries that might cause lost
date packets. This can be caused by a configuration change, by an LSP going down and back up, or
when the label for a tunnel LSP is changed without the LSP going down and back up (PD2-203414601).
Workaround. Reboot the slot with the MPLS module.
MPLS Module Might Not Be Recognized
When you have more than one MPLS module in your chassis and you enable MPLS, one of the
modules might not be recognized. If an MPLS module is not recognized, reboot the slot
(PD2-199489301).
LSP NHLFE Not Updated
The values for the LSP NHLFE are not updated in the MPLS module when the downstream label is
changed. This might be the result of a change in the TLS’s address (PD2-203606001).
Workaround. Reboot the slot with the MPLS module.
Removing Second MPLS Module Causes Traffic to Stop
If you remove an MPLS module from a chassis with more than one MPLS module installed and using a
TLS tunnel, traffic stops. To work around this, replace the MPLS module (PD2-199171622).
Disabling One MSM Might Cause Loss of Throughput
If you disable one MSM in a dual-MSM configuration, you might lose half of the throughput on ARM
and MPLS modules (PD2-199171610).
The output of the show diagnostics backplane utilities command shows slots with ARM or
MPLS modules as having only two backplane links, rather than the normal four backplane links.
Cannot Delete an LSP Previously Referenced by a TLS Tunnel
You cannot delete an LSP previously referenced by a TLS tunnel. To delete the LSP, first reboot the
switch (PD2-222522101).
EAPS Trap Not Sent if Connection is Through I/O Port
If the EAPS secondary port link is down, the EAPSStateChange trap is not sent to the management
station if the connection is through an I/O port that is part of the protected VLAN instead of to the
management port. To avoid this, connect the management station through the management port or an
I/O port that is not on the protected VLAN (PD2-180185834).
The card-down Option
In a fully redundant configuration, if you configure the card-down option in the configure
sys-health-check command and checksum errors are detected, the MSM is not taken offline as
ExtremeWare 7.3.1b3 Release Notes 67
Clarifications, Known Behaviors, and Resolved Issues
expected. To work around this, use the configure sys-health-check auto recovery 3 offline
command (PD2-105991401).
10 Gigabit Ethernet and CMT
If you use 10GLRi or XENPAK ports with the address-based or round robin load-sharing algorithms
and the master link is lost, FDB entries are not learned (PD2-197753713).
XENPAK with the BlackDiamond 6816
On a BlackDiamond 6816, if you configure the MSM to keep links up, save the configuration, and
reboot the switch, XENPAK links do not come up (PD2-198280301).
Cross-Module Trunking Not Supported on MSM64i’s
If you enable cross-module trunking on a chassis with MSM64i’s installed, you receive the following
error message:
All load share ports must be on the same modul
Cross-module trunking is not supported with MSM64i’s. To enable load sharing across modules, install
MSM-3’s (PD2-193845958).
Cross-Module Trunking Module Support
Table 24 lists the modules that support load-sharing across modules.
Table 24: Cross-module trunking module support
Module CMT Support
G8Xi Yes
G8Ti Yes
G12SXi Yes
G16X3 Yes
G24T3 Yes
F32Fi Yes
F48Ti Yes
F96Ti Yes
WDMi No
10GLRi Yes
10GX3 Yes
MPLS No
ARM No
P3cMi No
P3cSi No
P12cMi No
P12cSi No
A8cMi No
A3cSi No
68 ExtremeWare 7.3.1b3 Release Notes
Clarifications and Known Behaviors
Cross module trunking is not supported on WDMi modules (PD2-176314520).
Master Slot Must Be Active for CMT
The slot with the master load-sharing port must be populated and active when you configure a
cross-module load-sharing group. If the master slot is unavailable at configuration, cross-module
load-sharing traffic is not forwarded (PD2-175825901, PD2-175854401).
MSM-3 Log Might Be Out of Chronological Order
Log events are stored independently on the master and slave MSM-3. Thus, a failover might cause the
log to appear out of chronological order, or missing information. Concatenating the logs provides all log
information (PD2-172852704).
Source Addresses Might Age Out of FDB
If a MAC source address is exclusively sourced on a slave CMT slot, such as with a port-based
algorithm, the FDB entry might be aged out. To avoid this, use address-based load sharing on the
neighbor switch (PD2-170942776).
Do Not Use Static FDB Entries with CMT
Do not use static FDB entries with cross-module trunking. If the CMT master fails, static FDB entries are
not transferred to the group members (PD2-170942732, PD2-170942701).
Saving Health Check Configuration After Failure Causes Console Crash
If an MSM fails a system health check with packet memory errors and is taken offline, the slave
becomes the master, but you cannot save the configuration. To avoid this, clear the diagnostics, upload
the configuration, and reboot the switch before saving (PD2-171914501).
Diagnostics on MSM-3 with Hitless Failover Causes Failover and Spurious Message
Running diagnostics on the master MSM-3 with hitless failover enabled causes the MSM-3 to fail over
to the slave and log a hardware failure message. You can safely ignore this message (PD2-168317013).
Do Not Configure a Port-Based Backplane Algorithm When CMT is Enabled
Do not configure a port-based backplane policy when CMT is enabled. It might cause all egress ports on
a given slot to be skipped. To work around this problem, configure an address-based backplane policy.
In a similar manner, if a port-based algorithm is selected for the trunk, some egress ports might be
skipped. To change the load share policy of a trunk, disable sharing for the port and enable sharing
with an address-based policy, then reboot the switch (PD2-165883601).
Cross-Module Trunking and ACLs
Flooding on a CMT trunk cannot initially be blocked by ACLs. After the remote end responds with a
PDU, the destination address is learned via source address learning. Once the address is learned,
packets are blocked in hardware by an ACL (PD2-153404501, PD2-115139620, PD2-130299801,
PD2-130299807).
ExtremeWare 7.3.1b3 Release Notes 69
Clarifications, Known Behaviors, and Resolved Issues
ExtremeWare 7.0 (and Later) Does Not Support xmodem
You cannot use xmodem to transfer ExtremeWare 7.0 (or later) to an MSM (PD2-137101701).
4,000 VLANs on a BlackDiamond
If you configure more than 4,000 VLANs, EDP might crash, causing ESRP to fail (PD2-153821210).
E1 Module and the restart port Command
After you use the restart port command, E1 modules occasionally fail to establish a physical link
(PD2-85857901).
PPP Links Through E1 modules
PPP links through the E1 module are not always re-established after a reboot. To re-establish the PPP
link, use the restart ports command (PD2-109252301).
Slot Failure Messages During a Broadcast Storm
If you have more than 15 Gigabit Ethernet links between two chassis, all in the same VLAN and
generating a broadcast storm, the system health check records slot failures in the log. When the
broadcast storm stops, the log messages also stop (PD2-117946811).
No Image Information Reported to SNMP with One MSM
If you only install an MSM in slot B of a BlackDiamond 6804, BlackDiamond 6808, or BlackDiamond
6816, no primary or secondary image information is reported to your SNMP NMS (PD2-129612901).
BlackDiamond 6816 MSM C and D Diagnostics Messages not in Syslog
If you run diagnostics on an MSM in slot C or D of a BlackDiamond 6816, messages are not recorded in
the syslog. To view the diagnostics messages, use the show diagnostics command (PD2-118049501).
Disabling CLI Paging from the Slave MSM64i
Enabling or disabling CLI paging from the slave MSM64i has no affect on the master MSM64i paging
configuration (PD2-104377501).
The unconfig switch all Command
If you use the unconfig switch all command and immediately use the config default vlan
delete port all command, the switch reboots (PD2-105474401). To avoid this situation, after you
unconfigure the switch, wait for the switch to completely reboot before you delete the ports.
BlackDiamond 6816 MIB Value for Input Power Voltage
On the BlackDiamond 6816, the extremeInputPowerVoltage attribute in extremeSytemCommonInfo is
shown as “0” and the extremePowerSupplyInputVoltage in the extremePowerSupplyTable is shown as
“unknown.” These values cannot be obtained from the switch (1-841J1).
70 ExtremeWare 7.3.1b3 Release Notes
Clarifications and Known Behaviors
Alpine
Mirroring Failure on an Alpine 3808 with GM4x Module After a Save and Reboot
Port mirroring might fail on the Alpine 3808 with a Gigabit Ethernet, 4-port, GBIC module after saving
and rebooting the switch. As a workaround, disable and enable the mirroring port after rebooting the
switch (PD3-1025737).
With IE5.0 Vista Page is not Accessible Through HTTPS
Using IE5.0, you cannot access the Vista page through HTTPS. However, you can access the Vista page
through HTTPS using IE5.5+ (PD3-2738891).
Autonegotiation on VDSL Ports Set Incorrect Speed
A VDSL port configured to autonegotiate sets the speed to 100 Mbps when connected to a 100 Mbps
port (PD2-209953030). The maximum speed for the VDSL port is 10 Mbps. As a workaround, configure
autonegotiation off, and set the speed to 10 Mbps, full duplex. For example, to configure port 3:1, use
the following command:
configure port 3:1 auto off speed 10 duplex full
VDSL Ports do not Support Jumbo Frames
Do not enable jumbo frames on VDSL ports. Jumbo frames are not supported on VDSL ports
(PD2-208090059).
New Accounts with WAN Module Installed are pppuser
If you have a WAN module installed and you create a user account, the account is automatically created
as pppuser (PD2-197374626).
Limited Commands Mode
When in limited commands mode, the slot status LED remains orange, though the link is taken down
(PD2-99107226).
VDSL Modules in a Half-Duplex Link
A VDSL CPE operating in a half-duplex link can lock up when used with a hub and running wire-rate
randomized traffic. This is a hardware limitation. A restart of the VDSL port will recover, but if the
traffic continues at wire-rate and is randomized, then the problem will reoccur (PD2-71538118).
Summit
Spurious Summit48si Power Supply Messages
When a Summit48si powers up, some power supplies might generate error messages similar to the
following:
<INFO:SYST> PSU-A output failure recovered.
<INFO:SYST> PSU-A powered on.
<INFO:SYST> PSU-A powered off.
ExtremeWare 7.3.1b3 Release Notes 71
Clarifications, Known Behaviors, and Resolved Issues
You can safely ignore these messages (PD2-208576301).
Output of the show log Command
The most common reason for transceiver diagnostics failure is heat. Thus the show log output displays
the TRXDIAG tag in the temperature log message (PD2-147462529).
The unconfigure switch all Command Clears the Default VLAN from s0
After you reset the switch to the factory defaults using the unconfigure switch all command, s0
does not contain the default VLAN. To add the default VLAN to s0, delete then add all ports in the
default VLAN (PD2-143709201).
Health Check Error Messages
Error messages from the system health check display the incorrect location (PD2-110132842).
Summit48i Redundant PHY
When the primary port of a redundant pair is disabled and the link removed, the LED for that port
continues to flash indicating it has a link and is disabled (9239).
Summit48i Single Fiber Signal Loss
The Summit48i is currently not able to detect a single fiber strand signal loss due to the hardware based
Auto Negotiation parameters (10995).
SNMP Results for Power Sources
The inputPower MIB is unable to differentiate between 110 VAC and 220 VAC input on the Summit
series switches when accessing this MIB attribute through SNMP (10870).
Summit48si MIB value for Input Power Voltage
On the Summit48si, the extremeInputPowerVoltage attribute in extremeSytemCommonInfo is shown as
“0” and the extremePowerSupplyInputVoltage in the extremePowerSupplyTable is shown as
“unknown.” These values cannot be obtained from the switch (1-841J1).
Command Line Interface (CLI)
Mirroring Cannot be Disabled
Mirroring cannot be disabled until all mirroring ports are deleted (PD2-244886705).
Console Does Not Wait for User Input
The console is not waiting for a response after issuing the prompt Continue? (yes or no) <<<.
When you press the ENTER key, the key strokes being sent are CR+LF. With a console connection, the
switch interprets this as though you pressed the ENTER key twice. This problem does not occur if you
are using a Management port connection.
72 ExtremeWare 7.3.1b3 Release Notes
Clarifications and Known Behaviors
Workarounds.
e Connect through the Management port.
e Change your terminal setting to Ctrl+M instead of CR+LF (TELNET new line) if using PuTTY
version 0.54.
e Use Tera Term. When using Tera Term, CR is sent by default instead of CR+LF.
(PD2-247002201)
Command Does Not Function
The functionality associated with the command configure wireless ports x:x interface x
client-scan keep-ies [onjoff] is not implemented. The command exists on the switch, but is not
functional (PD3-3004440).
show fdb vpls Command Does Not Accurately Show the Total of FDB Entries
The show fdb vpls command does not show the correct total of FDB entries running on the switch
(PD3-2780831).
clear counters Command Does Not Clear Number Transmitted in a MPLS Health Check
The clear counters command does not clear the number of VPLSPINGS sent by the switch
(PD3-2570481).
show fdb port Command Does Not Reflect Correct FDB Data for that Port
The show fdb portlist command shows the same total as the show fdb command for the entire
switch. For example, if you issue the show fdb po 1:1 command, the output should show two MAC
addresses whereas a total of 55 is shown (PD3-1857861).
Maximum Number of ESRP Groups Supported in the ESRP MIB is Incorrect
The maximum number of supported ESRP Group and ESRP Neighbor Group is from 0 to 31, not 1 to
65535, as stated in the ESRP MIB table (PD2-244686417).
Not All configure debug-trace Options Are Displayed
The following configure debug-trace command options are available but are not displayed:
e ap-scan
e client-diag
e mac-radius
e wpa
e iapp
(PD3-2179879)
ExtremeWare 7.3.1b3 Release Notes 73
Clarifications, Known Behaviors, and Resolved Issues
SNMP Trap Commands Not Supported
The disable snmp trap port-up-down port mgmt and enable snmp trap port-up-down port
mgmt commands are not supported by the CLI. To enable or disable SNMP port-up-down traps on the
management port, use SNMP (PD2-162482918).
The show ports mgmt info Output Missing Flags
The output of the show ports mgmt info command does not display the flags (PD2-156475701).
Press [Return] Key Twice With enable temperature-log Command
You must press the [Return] key twice when entering the enable temperature-log command. If you
only press the [Return] key once, the system does not display the asterisk indicating a configuration
change. The log is correctly enabled by pressing the [Return] key once (PD2-152215201).
User Sessions Cannot Enable CLI Paging
You cannot enable CLI paging when logged in to a user account. It is enabled by default
(PD2-145565305).
Switching and VLANs
Renew/Refresh Required After Each Logout To Get IP Address
A DHCP enabled VLAN port might assign the same IP address to different clients. If you do not
perform a release/renew after each logout, other clients might not be able to get an assigned IP address
from the internal DHCP server (PD3-3255805).
Packets Sent to VRRP-MAC That Do Not Belong to the VRID of the VLAN are also Being
Accepted
Packets that are sent to VRRP-MAC that do not belong to the VRID of the VLAN are also being
accepted. This occurs when the same port is added to more than one VRRP VLAN as tagged
(PD2-244356901).
The show iproute Output
The output of the show iproute command now displays only the first eight characters of the VLAN
name (PD2-128392829).
MAC-Based VLAN Configuration Not Saved
If you configure and enable a MAC-based VLAN, save the configuration, and reboot the switch, the
configuration is lost (PD2-224261163).
Load Share Group Might Fail Back to Group with Fewer Ports When Using Software
Redundant Ports
If you have a primary load share group that fails over to the redundant load share group, and you
remove and reinsert the I/O module that contains the primary load share group, traffic fails back to the
74 ExtremeWare 7.3.1b3 Release Notes
Clarifications and Known Behaviors
primary load share group even though the primary load share group has fewer active ports. However, if
another port in the primary group fails, traffic correctly fails over to the redundant load share group.
For example, ports 1:1-1:5 are the primary load share group and ports 2:10-2:15 are the redundant load
share group. If you remove the cables from ports 1:1-1:3, the load share group fails over to ports
2:10-2:15. If you remove and reinsert the I/O module installed in slot 1 and do not attach the cables to
ports 1:1-1:3, the load share group fails back to the primary load share group. If you then remove the
cable from port 1:4, traffic fails over to the redundant load share group (PD2-223253601, PD2-225707301,
PD2-246246401, PD2-246246404).
Saving ip-mtu Settings
Dynamic TLS (Martini TLS) checks the MTU received from its peer in order for TLS to come to the
established state. It compares against the egress VLAN’s IP-MTU. If the egress VLAN does not have an
IP address defined, any non-default ip-mtu setting will not be saved through a switch reboot
(PD2-64084527).
VLAN priority and STP, EDP
STP and EDP (thus ESRP and EAPS) do not transmit packets in the queue specified by the VLAN
priority (1-5HOZ9).
Default Routes or Static Routes
If you define a default or static route, and then delete the VLAN on the subnet associated with the
default route, the default route entry remains although it is invalid. You must manually delete the
configured route.
If you define multiple default routes, the one with the lowest metric is used. If there are multiple routes
with the same lowest metric, the switch picks one of the routes.
Configuring a Protocol Filter with ‘ffff’
Creating a protocol filter with LLC of value Oxffff and assigning it to a VLAN will not work, and should
not be attempted. Doing so will assign all traffic to the VLANs containing that filter and will prevent
VLANs with no protocol filter to function properly. If configured and saved, you must issue an
unconfigure switch all to restore normal operation (2644, 4935).
Deleting Protocols from a VLAN
Adding a protocol to a VLAN might cause an EPC if the protocol was added to the VLAN, deleted
from the VLAN, recreated by the user, and re-added to the VLAN (6128).
MAC-Based VLANs and DHCP Relay
MAC based VLAN configurations should not be used in conjunction with DHCP. Currently, a host
which enters a MAC-based VLAN will not be able to use DHCP to obtain an IP address.
VLAN to VLAN Access Profiles
VLAN to VLAN access profiles are no longer supported on the BlackDiamond switch in ExtremeWare
6.0 or higher (7022).
ExtremeWare 7.3.1b3 Release Notes 75
Clarifications, Known Behaviors, and Resolved Issues
FDB
FDB Entries Disappear Before Aging Timeout
If you configure fdb agingtime to 100,000 seconds, the FDB entries disappear before the 100,000
seconds. The values disappear around 200+ seconds (PD2-248579601).
Cannot Add FDB Entry for Management VLAN
You cannot add an FDB entry for the management VLAN (PD2-156475718)
MAC Security
The source FDB address configuration will not discard ICMP packets (16340).
FDB Aging Timer
In ExtremeWare 6.2.0, the default value of the FDB aging timer was set to 1800 seconds on a newly
configured ExtremeWare 6.2.0 switch. In ExtremeWare 6.2.1 the default value has been changed back to
300 seconds. However, when upgrading from ExtremeWare 6.2.0 to ExtremeWare 6.2.1, the default value
will remain 1800 seconds. For upgrades from ExtremeWare 6.1.9 (or earlier) the default value will
remain 300 seconds. The FDB aging time can still be set to all previous values (1-85QD3).
Configure Less Than 400 Ports in a VLAN
If you use the clear slot command (which flushes the FDB) when there are 256,000 or more FDB
entries, the watchdog timer can cause the switch to reboot. To avoid this, configure less than 400 ports
in a VLAN (PD2-90223209).
Load Sharing
Removing Modules During CMT Testing Causes Loss of Traffic
When you perform the CMT trunk up/down tests and remove the modules and re-insert them, the
switch receives 50% less traffic. As a workaround, after you re-insert the modules and notice a 50% loss
of traffic, remove the ports and re-insert them (PD3-2162531).
Backplane Algorithm Not Working Properly When Changing the Algorithm from
Address-Based to Port-Based
When the backplane algorithm is changed from address-based to port-based the backplane still behaves
as an address-based algorithm, causing the traffic to appear on all ports instead of one port. As a
workaround, save and reboot the switch after changing the backplane algorithm (PD2-238168901).
Autonegotiation
Load sharing ports must be configured with autonegotiation set to on. Load sharing ports will not
transmit traffic correctly using any other setting (PD2-64617405).
76 ExtremeWare 7.3.1b3 Release Notes
Clarifications and Known Behaviors
Round Robin Load Sharing
If a port in a round robin load share group is removed, the traffic that was being transmitted on that
link will be distributed on only 1 of the other active load share links in the round robin group. The
traffic is not distributed evenly between the remaining ports (6977).
Port Based Load Sharing on Summit7i
Port-based load sharing on the Summit7i requires ingress ports to be on the same side of the switch
(ports 1 - 4, 9 - 12, 17 - 20, and 25 - 28 on the left, ports 5 - 8, 13 - 16, and 21 - 24 on the right) as the 8
ports in the load share group for all ports in the load share group to transmit/receive traffic (6975).
Alpine and Cross Module Load Sharing
The I/O module configured to contain the “master” port must be physically present in a cross-module
load sharing group for the system to pass traffic (8589, PD2-119098401).
Load Sharing and Specific Ports in a Load Share Group
Due to the load sharing algorithm used for round robin load sharing, when using 3, 5, 6 or 7 ports ina
load share group packet loss will be observed when sending wire-speed traffic across the load share
group. This occurs because some ports will be selected to transmit more packets than other ports
resulting in bandwidth over-subscription and subsequent packet loss. This only occurs with round-robin
load sharing configurations (10311).
Disabling Load Sharing if the Master is Down Generates Error
If the load sharing master link goes down, and you disable load sharing, the switch generates a ptag
error message (PD2-129379272).
Mirroring
Port Mirroring Does Not Work on Rate Shaping Loopback Port
You cannot use port mirroring on a port you have configured as a loopback port for ingress rate
shaping (PD2-243424420).
Delete Mirroring Filters Before Disabling Mirroring
You must delete all mirroring filters before you disable mirroring on the switch. If you attempt to
disable mirroring before deleting the mirroring filters, an error message similar to the following
appears: ERROR: Delete mirrored port(s) before disabling mirroring.
If you see this message, use the configure mirroring delete command to delete the mirroring filters
followed by the disable mirroring command to disable mirroring (PD2-246368703).
Port from Deleted VLAN Mirrors When Added to New VLAN on Alpine Switch
On an Alpine switch, if you configure a VLAN port for mirroring, delete the VLAN, and then add the
original port to anew VLAN, it is still configured for mirroring (PD3-1757651).
ExtremeWare 7.3.1b3 Release Notes 77
Clarifications, Known Behaviors, and Resolved Issues
Do Not Configure Port Mirroring While Port is Down
If you reconfigure port mirroring while the physical port is down, switched traffic that crosses a routing
boundary is duplicated (PD2-147476551).
ELSM
Spurious Error Message with ELSM
Disabling or enabling ELSM or the ELSM auto-restart port feature might generate an error message
similar to the following:
hfoCliEvent: Command does not support Hitless Failover
You can safely ignore these messages (PD2-182478105).
Spanning Tree
Adding or Deleting a Port from a VLAN Flushes FDB on All STP Protected VLANs
Adding or deleting a port from a VLAN flushes FDB on all STP protected VLANs, which causes the
flow redirect rules with ping tracking configured to also go down (PD2-245992601).
show vlan STP Output is not Correct
The output for the show vlan command does not mark the flag as “T” (member of the STP domain)
when the VLAN has no ports associated with it. Because the VLAN has no associated ports, it is not
shown as part of the STP domain (PD2-246881901).
STP Topology Change in One STP Domain (S1) Flushes FDB in Other STP Domain (S2)
When two STP instances (S1 and S2) in dotlw mode share the same physical ports, that is, the physical
port is part of both domains, then a topology change in one STP domain (S1) will flush the FDB learned
in the other STP domains (PD2-145439733).
STP CPU Utility Usage Increases and Drops Ping Packets
The STP task CPU utility increases up to 20% and drops ping packets when adding/deleting a port
from the VLAN. Disabling or enabling ports, or adding a tagged port to the VLAN does not affect
switch performance. A workaround is to enable STP on ports that have STP disabled (PD2-236187221,
PD2-239254001).
Disabling ignore-bpdu Adds CPU MAC Entry to FDB
If you disable ignore-bpdu, an entry for the CPU MAC is added to the FDB for the VLAN
(PD2-225957431).
Enabling STP on MAC-based VLANs Might Cause Connectivity Loss
On a BlackDiamond, if you enable STP on a MAC-based VLAN, you might experience a loss of
connectivity (PD2-223958706).
78 ExtremeWare 7.3.1b3 Release Notes
Clarifications and Known Behaviors
Incorrect Log Message
If you reboot after enabling STP and VLANs, the device might log the following incorrect message:
<STP.OutBPDU.Drop> Port=8:2: Illegal message ag (65517)
This is a display issue only; functionality is not affected (PD2-208909326).
RSTP Does Not Detect Topology Change
If a physical link transitions from down to up when the ports are configured with point-to-point links
and 802.1w, RSTP does not detect a topology change (PD2-197365089).
Disabling STP Might Display Topology Change
When you disable STP, the output of the show stpd command displays a topology change. If there was
not actually a topology change, you can safely ignore this indicator (PD2-165211765).
FDB Not Flushed After Link Failure with RSTP
When using RSTP, the FDB is not flushed when recovering from a link failure. This is the expected
behavior (PD2-143730501).
Do Not Configure All Ports in s0
With all ports on several FM-32 modules in s0 and more than 256,000 FDB entries continuously
learning, deleting a range of ports from a VLAN, adding the same range to another VLAN, deleting
them from that VLAN, then adding them back to the first VLAN can cause a watchdog reboot. Do not
configure all ports in s0 (PD2-118450167).
Error Messages with Topology Changes
If you have STP domains configured on a switch and add active ports to the domain, bringing the links
up and down might generate error messages similar to the following (PD2-159834201):
<Erro:STP.OutBPDU.Drop> Port=4:13: Illegal message age (21)
Large STPD Configuration Download Might Reboot Switch
If you download a configuration with more than 70 STP domains, and each domain has more than 120
VLANs, the switch might reboot. To avoid this, disable the system watchdog timer, download the
configuration, and enable the timer (PD2-136044092).
A Large STP Configuration with 10 Link Transitions
If you have more than 120 802.1w STPDs with more than 2,000 total VLANs, a link failover might form
a loop. The loop might last as long as 40 seconds, depending on the number of VLANs configured
(PD2-135691018).
Configure Fewer than 4,000 VLANs in an STPD
If you add more than 4,000 VLANs to an STP domain, the switch might run out of memory
(PD2-135842818).
ExtremeWare 7.3.1b3 Release Notes 79
Clarifications, Known Behaviors, and Resolved Issues
Output of show stpName port detail Command in Hex Format
The output of the show stpName port detail command displays the Port ID in hex format instead of
decimal format. If you do not specify the detail parameter, the output correctly displays in decimal
format (PD2-136044001).
If You Delete a Port from the STPD, You Cannot Add It Through a VLAN
If you delete a port from the STPD, then add a VLAN containing that port to the STPD, the deleted port
is not added. To work around this, add the port back to the STPD (PD2-144382901).
The unconfigure stp Command Does Not Clear All Configurations
The unconfigure stpd command does not clear the tag, VLAN, operational mode, rapid root failover,
port mode, or port link-type. To clear these configurations, use the delete stpd command
(PD2-137310575).
Enabling ignore-bpdu or ignore-stp
If you enable ignore-bpdu or ignore-stp on a VLAN and then enable STP, the switch still participates in
STP election. To work around this, reboot the switch (PD2-140533593).
Configuring a VLAN from Vista
If you create an STPD using ExtremeWare 6.1.9 (or earlier), add a VLAN, save the configuration,
upgrade to ExtremeWare 6.2.2b68 (or later), and save the configuration, you receive the following error
message when you try to modify the VLAN from Vista:
ERROR: Cannot assign bridge to stpd! HINT: If a port is part of multiple vlans, the
vlans must be in the same Spanning Tree domain.
To work around this problem, make configuration changes from the CLI (PD2-118450190).
STP and VLAN Tagging
VLAN tagging is not supported with 802.1d Spanning Tree (STP) BPDUs. Therefore, all BPDUs in a
802.1d STP domain are untagged. However, Extreme Multiple Instance Spanning Tree (EMISTP) and
Per-VLAN Spanning Tree (PVST+) do support VLAN tagging of BPDUs.
EMISTP and Ingress Rate Shaping
If a loop exists in your network, but STP is not enabled and Ingress Rate Shaping is, the switches
appear to hang and are rebooted by the watch-dog timer. A similar situation exists if a loop is covered
by STP on both sides and is disabled on one side; normally the other switch immediately blocks the
right port(s), but when Ingress Rate Shaping is present, both switches appear to hang and are rebooted
by the watch-dog timer (1-5E9R1).
Upgrading From an ExtremeWare 6.1.9 (or earlier) Configuration
After downloading an ExtremeWare 6.1.9 (or earlier) configuration to an ExtremeWare 6.2.0 (or later)
image, a port belonging to a non-default VLAN generates the “Stpd s0, Port 1:1 does not exist” error
message because that VLAN does not belong to domain s0 by default (1-BMP5D).
80 ExtremeWare 7.3.1b3 Release Notes
Clarifications and Known Behaviors
ESRP
ESRP Master Does Not Change to the Neutral State
The ESRP Master might not change to the neutral state on the super-VLAN, even though there are no
active ports on any of the sub-VLANs.
Workaround. Disable the ESRP on the VLAN and enable it again (PD2-251147301).
The disable slot all Command Generates EDP Errors
If you have ESRP enabled, the disable slot all command generates EDP errors. You can safely
ignore the error messages (PD2-166105101).
Large Configurations Might Lock Console when Enabling and Disabling s0
If you have more than 60 STP domains with more than 200 tagged VLANs between them and more
than 6 ports in each, and you enable then immediately disable s0, the console might freeze for up to a
minute. Larger networks cause the console to remain locked for longer periods. The switch is still
operating, and the console unlocks after the processing finishes. To work around this, either wait before
disabling s0, or wait until the console unlocks (PD2-159834277, PD2-151426418).
ESRP and Protocol-Based VLANs
ESRP-aware switches cannot connect to an ESRP switch through a port configured for a
protocol-sensitive VLAN using untagged traffic (PD2-99007701).
ESRP and Load Sharing
If you enable load sharing on ports that belong to more than 200 VLANs, the switch reboots. To avoid
this, first enable load sharing, then add the ports to the VLANs (PD2-99259801).
Hot-Swapping a Module with 5,000 ACLs
Hot-swapping a module on a switch that has 5,000 or more ACLs configured can cause an ESRP state
change (PD2-107800998, PD2-103938301). To avoid the state change, configure the neighbor timeout
value to 12 seconds.
Traffic Convergence Time
Traffic convergence after a link failure can take as long as 5 seconds with 2,000 VLANs and 256,000 FDB
entries. This delay can cause ESRP state changes as traffic converges (PD2-89915300).
ESRP PDUs on Ports
ESRP PDUs received on ports that do not belong to any VLAN are processed as valid ESRP PDUs and
can trigger state changes (PD2-89481346). To avoid this, assign all ports to valid VLANs with matching
tags.
ExtremeWare 7.3.1b3 Release Notes 81
Clarifications, Known Behaviors, and Resolved Issues
ELRP
ELRP and Ingress Rate Shaping
Do not use ingress rate shaping on an ELRP-enabled VLAN (PD2-133066184).
VRRP
Proxy ARP Replies on VRRP Enabled VLANs Are Incorrect
When sending out proxy ARP replies on a VRRP enabled VLAN, the sender MAC address in the ARP
Reply contains “System MAC” instead of “VRRP MAC” (PD3-1275521).
Backup Transition Creates Duplicate Packets
A VRRP transition from backup to master might cause duplicate data packets to be transmitted for a
short period of time. The packets are dropped, so no action is required (PD2-129379226).
QoS
QoS Profiles Applied to Non-Master Ports in Load Sharing Groups
Although QoS profiles should only be applied to the master port in a load sharing group, the CLI does
not enforce this behavior. When a QoS profile is applied to a non-master port, the CLI accepts the
command, issues no error, but does not apply the profile (PD2-243742691).
QoS Profile Statistics Are Not Shown for Non-master Ports in a Loadshared/CMT Group
When a QoS Profile is applied to traffic being transmitted through the trunk ports (CMT), the QoS
profile statistics for some ports is 0, even though the port statistics show that the traffic is being sent
through the same ports (PD2-235114601).
The qosprofile Accepts a Value Greater than 100%
The maxbw parameter in the configure qosprofile command incorrectly accepts values greater than
100%; however, the maximum bandwidth is still 100% (PD2-123662004).
Re-Ordering Access List Precedence Numbers
When you add a new ACL rule with a precedence number, the switch re-orders existing rules with
lower precedence numbers to make room for the new rule. If, during this re-ordering, two rules have a
precedence number difference greater than one, the switch generates an error message similar to the
following:
<WARN:KERN> Access rule does not exist
You can safely ignore this error message (1-FAO8M).
82 ExtremeWare 7.3.1b3 Release Notes
Clarifications and Known Behaviors
Access List FDB Entries not Cleaned Up
If you delete an access list with the “f” flag (flow rule), the associated FDB entries might not be cleared
(PD2-110082518).
Access Lists Using the IP Deny Any Rule
When using an access control list with an IP deny any rule, all ICMP traffic will be blocked within a
VLAN (Layer 2). If using an access list with an IP deny any rule across VLANs (Layer 3), ICMP traffic
will not be blocked.
Access Lists and IP Fragmentation
When using IP fragmentation, since the TCP header is treated as data and only the IP header
information is being replicated in each packet, access-lists that apply to that flow will not apply as the
TCP/USP port information is not included after the first fragment (for subsequent fragments).
QoS Configuration Bandwidth Parameters
Minimum and maximum percentage parameters for a specific port on the default VLAN will not be
saved across reboots. The configuration change will be applied when configured. This issue only occurs
on the BlackDiamond (15500).
Creating Access Lists from Multiple Sessions
When creating or modifying access control lists, please ensure that no other administrator sessions are
attempting to create or modify the system access control lists simultaneously. This might result in data
corruption (1-579HD).
5,120 Access Lists and SNMP
Although you can configure up to 5,120 ACLs, SNMP only recognizes 1,280. Deleting an ACL that is not
recognized by SNMP generates the following error (PD2-64880917):
<WARN:SNMP> SNMP IPQOS Could not find entry instance 5083 to delete
Monitoring QoS and the show port qos Command
When monitoring QoS, do not use the show port qos and enable qosmonitor commands on the
same port at the same time. These commands in conjunction lock the console session. However, the
syslog does capture the output (PD2-64202681, PD2-80836531).
MPLS
Cannot Delete TLS VLAN After Deleting TLS Tunnel When MPLS is Disabled
You cannot delete a TLS VLAN after you delete a TLS tunnel when MPLS is disabled. To delete the TLS
VLAN, enable MPLS or reboot the system (PD3-2553271).
IP Interface of Local End-point VLAN for TLS Tunnel or VPLS Can be Modified
When you configure a VLAN with loopback-mode and IP forwarding enabled, and an IP address, a TLS
tunnel or VPLS is configured using this VLAN as the local end-point. You can disable IP forwarding
ExtremeWare 7.3.1b3 Release Notes 83
Clarifications, Known Behaviors, and Resolved Issues
when either the TLS tunnel or VPLS is using the VLAN as a local end-point. The IP address of the
VLAN can be changed or unconfigured when a VPLS is using the VLAN as the local end-point, but not
the TLS tunnel (PD2-243426413).
Clear Counters Command Does Not Clear RSVP LSP Count
The clear counters command does not clear the RSVP LSP count (PD3-3250311).
Targeted LDP Sessions Become Operational When MPLS is Disabled
Issuing the command, show mpls idp, might display operational targeted LDP sessions, even to
switches with MPLS disabled. The TLS tunnel VC state is displayed as “Complete” and the LSP state is
displayed as “Down.” No traffic traverses the tunnel. There is no workaround (PD2-229043816).
Targeted LDP Sessions do not Come Up When OSPF is Disabled and Router ID is
Automatic
When router ID is automatic, and OSPF is disabled, the router ID is 0.0.0.0. When a TLS tunnel or VPLS
is created in this state, the source address is copied from the router ID. A workaround is to manually set
the router ID or enable OSPF first (PD2-218047403).
Bi-Directional Rate Shaping
Secondary MAC Used for Rate Shaping Not Released
When you have added a rate-shaping port to a VLAN and then to a load-sharing group, that port is
removed from the VLAN. In this situation, the secondary MAC address used for rate limiting is not
released (PD2-249582310)
Aggregate-Bandwidth Granularity Correction
The granularity for the aggregate-bandwidth must be closely aligned with the configured values
(PD2-249336801).
Table 25: Bandwidth Configuration for Hierarchical Rate Shaping
Suggested Bandwidth Configuration
Requited Bandwidth Fixed Frame Size Random Frame Size
3 — 3
5 — 6
8 — 8
10 15 10
15 20 15
20 25* 20
25 25 25
30 30* 30*
35 30 35
84 ExtremeWare 7.3.1b3 Release Notes
Clarifications and Known Behaviors
Table 25: Bandwidth Configuration for Hierarchical Rate Shaping
Suggested Bandwidth Configuration
Requited Bandwidth Fixed Frame Size Random Frame Size
40 40 40*
45 45 40
50 50* 50
55 55* 50
60 65 60
65 65 65
70 70* 70*
75 75 70
80 80 80
85 85 80*
90 90 85*
95 95 95
100 100 100
A NOTE
Numbers marked with an asterisk (*) have appreciable discrepancy on the higher side. For example, if
the port is configured for 70% bandwidth, 72% bandwidth might be seen.
SecureMac Flags Not Shown
SecureMac flags are not shown on FDB entries of rate shaped ports (PD2-171300406).
Locking and Unlocking Learning
If you configure a rate shaping port to lock learning and unlock learning, the loopback FDB is not
flushed. This causes traffic destined for the port to be flooded. You must manually flush the FDB using
the clear fdb command (PD2-124568416).
1000Base-T Ports as Loopback Ports
If the loopback port for bi-directional rate shaping configurations is configured on 1000Base-T ports, the
speed of that port cannot be changed from 1000 Mbps to 100 Mbps as the bandwidth settings will not
be accurate when configured in 100 Mbps mode.
EAPS
Configuring Cross Module Trunking Causes EAPS Failure
When configuring cross module trunking, if you connect a slave port, the transit switch does not
forward the EAPS hello packets and the EAPS ring is in the failed state (PD2-238232230).
ExtremeWare 7.3.1b3 Release Notes 85
Clarifications, Known Behaviors, and Resolved Issues
Shared-Port Link ID Limits
When you configure a shared-port link ID, the CLI does not enforce a limit. However, if you input a
value greater than 65535, the value is chopped to be within the range 1 - 65535 (PD2-243424458).
EAPS Performance Statistics
Table 26 lists the EAPS performance statistics for a single EAPS domain with the default filter.
Table 26: EAPS performance statistics with the default filter
Link Down Link Down Link Up Link Up
Protected Convergence Convergence Convergence Convergence
VLANs Upstream (ms) Downstream (ms) Upstream (ms) Downstream (ms)
1 106 101 100 99
500 260 220 170 130
1,000 310 220 170 227
4,000 534 533 675 900
Table 27 lists the EAPS performance statistics for a single EAPS domain with no filters.
Table 27: EAPS performance statistics with no filters
Link Down Link Down Link Up Link Up
Protected Convergence Convergence Convergence Convergence
VLANs Upstream (ms) Downstream (ms) Upstream (ms) Downstream (ms)
1 1.9 1.8 1 1
500 54 54 70 100
1,000 106 106 170 226
4,000 415 415 675 900
Table 28 lists the EAPS performance statistics for a single EAPS domain with a single protected VLAN
and varying FDB sizes.
Table 28: EAPS performance statistics with varying FDB sizes
Link Down Link Down Link Up Link Up
Convergence Convergence Convergence Convergence
FDB Entries Upstream (ms) Downstream (ms) Upstream (ms) Downstream (ms)
2,000 2.4 3.2 1.1 1.2
10,000 2.5 3.5 1.3 1.4
50,000 4 5 2.8 3
100,000 5 6 4 4
ESRP and EAPS Secondary Port
Configuring ESRP Host Attach on an EAPS secondary port causes a broadcast storm (1-B1O04L).
Incorrect show vian Output
The show vlan output incorrectly lists the EAPS secondary port as active with an asterisk (*). The
number of active ports is correctly displayed (PD2-59142420).
86 ExtremeWare 7.3.1b3 Release Notes
Clarifications and Known Behaviors
IP Unicast Routing
Reset the FDB Aging Timer
When you disable multinetting, you must reset the FDB aging timer to 300 seconds using the
configure fdb agingtime command (PD2-160697401).
No Static ARP Entries
The use of Static ARP entries associated with superVLANs or sub-VLANs is not supported in this
release (5106).
ARP Entry Age
The age of ARP entries changes to a large value when system time is changed (1-E7FIV).
Multinetting and the Show VLAN Stats Command
The show vlan stats <vlan_name> command is not supported on multinetted VLANs (12196).
Multinetting and VRRP
Multinetting is not supported with VRRP (1-9YG1B).
IPv4 Routing
PIM CRP Timer Error
If you configure the PIM CRP timer to a high value and then reconfigure the timer to a lower value, the
lower value is not accepted. The switch continues to use the original higher value to send out the
advertisements. As a workaround, delete the existing CRP and add it again, or add another CRP
(PD2-249465903).
RIP Routing
Problems with Default Route Origination Addition and Purging
Default routes are not being sent and withdrawn using trigger update messages. When you issue the
disable rip command, the default route is removed from the peer routing table after the route
timeout duration (PD2-243713601).
RIPv1 Learned Routes Might Not Be Purged Immediately
When a RIPv1 learned route has a matching subnet on one of the learning router’s own interfaces, and
when the subnet mask of that particular interface is modified, the RIP routes with both the subnet
ranges are advertised to it neighboring RIPv2 peer. This can create blackholes in the network for the RIP
route timeout duration (PD3-2535701).
ExtremeWare 7.3.1b3 Release Notes 87
Clarifications, Known Behaviors, and Resolved Issues
RIPv2 Authentication
The authentication feature of RIPv2 is not supported.
RIP in Conjunction with other Routing Protocols
It is recommended that RIP be enabled only on routers running with less than 10,000 routes from other
routing protocols, such as BGP or OSPF.
OSPF
OSPF Originate Default Cost Can Be Set Incorrectly
When configuring OSPF Originate Default, an incorrect cost of 0 (zero) is accepted. If you configure the
OSPF Originate Default cost to 0 (zero) the default route will not propagate (PD2-213413326).
LSA Batch Interval Not Supported
The LSA batch interval feature is not currently supported. Though you can configure the feature,
(PD2-222030701).
Static Route with Switch’s Address as Gateway Not Advertised
If you configure a static route with the switch’s IP address as the gateway, that route is not advertised.
To avoid this, do not use the switch’s IP address as the gateway (PD2-222030705).
AS-external LSAs Might Not Be Regenerated
AS-external LSAs are not regenerated after an active LSA is removed or a neighbor goes down
(PD2-149426154).
Error Message Not Generated
If you configure a low ase-limit with a lot of type-5 LSAs, enabling OSPF causes a database overflow
state before OSPF adjacency is built. This should generate a critical error message, but does not
(PD2-148164866).
Disable OSPF Before Adding or Removing External Area Filters
If you configure an OSPF area external filter on an ABR, and the filter is set to exclude routes that have
already been learned, an OSPF failure occurs. A workaround is to disable OSPF before adding or
removing OSPF external area filters (PD2-105170634).
IS-IS
Unicast Packets Considered Broadcast
Unicast packets are occasionally considered broadcast packets and dropped (PD2-142499344).
88 ExtremeWare 7.3.1b3 Release Notes
Clarifications and Known Behaviors
BGP
A Session Down Due to Max Prefix Limit Will Not Re-establish
BGP peering Session that goes down as a result of exceeding the peer maximum prefix limit restriction
without the Hold timeout option, will fail to re-establish itself, unless that BGP peer session is disabled
and enabled again (PD3-3333831).
Large Number of Access Profiles and a Peer Reset
You can add a maximum of 10 BGP community numbers in inbound and/or outbound route updates
using access-profiles and/or route-maps. If you add more communities, BGP might crash
(PD2-160136950).
Default Route Might Not Be Deleted
If you have the export of static BGP routes enabled, the IP route table has a default static route and BGP
is redistributing the default route using the configure bgp add network command, then after you
delete the default route from BGP using the configure bgp delete network command, the default
BGP route is not withdrawn from the neighbor’s table (PD2-159150038).
BGP Aggregation with a Maximum Prefix of 300,000
Disabling BGP, configuring the maximum prefix to 300,000 or more, enabling BGP aggregation,
configuring some aggregate routes, and enabling BGP generates error messages similar to the following
(PD2-147347223):
<Erro:BGP.Misc.DelAggrtNetErr> Count lost sync for Net 202.7.243.0 Mask 255.255.255.0
Redistributing BGP Routes to OSPF
Redistributing 70,000 or more BGP routes into OSPF depletes the system resources and the switch might
run out of memory, causing task exceptions. Do not redistribute 70,000 or more BGP routes into OSPF
(PD2-74932501).
IP Multicast Routing
PIM SM Switch Reboot will not Re-establish the Existing Multicast Traffic Present
Before Reboot
If multicast traffic is flowing through a switch configured for PIM SM, and that switch is rebooted, the
steam will be dropped (PD3-3359901).
PIM DM Switch Reboot Might Delay Re-establishment of Traffic
If multicast traffic is flowing through a switch configured for PIM DM, and that switch reboots, it might
take a long time to re-establish the traffic (PD3-3031243).
(S,G) Packets are Sent to CPU When Route to Source is Lost in Last Hop Router
If a PIM SM enabled router looses the route towards the Source (S) but has interested receivers (*,G), all
the multicast packets are directed to the CPU (PD3-2423281).
ExtremeWare 7.3.1b3 Release Notes 89
Clarifications, Known Behaviors, and Resolved Issues
The unconfigure igmp Command Does Not Unconfigure All Parameters
The unconfigure igmp command does not set the forward-mcrouter-only or flood-list parameters
to the default values (PD2-141266115).
If PIM-Snooping is Enabled on Current Traffic, All (S,G) Entries Will be Marked as
Invalid
If traffic is present before PIM-Snooping is enabled, or the PIM-Snooping switch reboots as traffic is
present, all (S,G) entries will be marked as invalid. If PIM-Snooping was enabled before the traffic is
received, the entries are marked correctly (PD2-229351706).
Enable or Disable IGMP Snooping on a Sub-VLAN
To disable or enable IGMP snooping on a sub-VLAN, delete the sub-VLAN from the super-VLAN,
change the IGMP snooping status, and add the sub-VLAN to the super-VLAN (PD2-136478101).
Do Not Disable IGMP Snooping with Static Snooping Entries
If you disable IGMP snooping on a VLAN, the configured static IGMP snooping entries do not reply to
the IGMP querier, while real hosts attached to the VLAN will (PD2-158477713).
(S,G) Entry Not Created if RP is Rebooted
An (S,G) entry is not created if the RP is rebooted (1-F4YIP).
Cisco Interoperation
For proper Cisco interoperation, use Cisco IOS version 11.3 or later, which supports PIM 2.0. Cisco
customer support also recommends using PIM in favor of DVMRP whenever possible on Cisco routers
(4669).
Traffic Rate Exceeding Last Hop Threshold
When the traffic rate exceeds the configured last hop threshold, the last hop does not initialize; but if
the sending traffic rate is set to 50 Kbps, it switches to STP correctly (1-57NMY).
Security and Access Policies
Changing VLAN and Wireless Port IP Causes RADIUS Proxy Failure
Authentication failures occur when you change the VLAN and wireless port IP resulting in a RADIUS
proxy failure (PD3-7388921, PD3-6751371).
Cannot Apply a New Port after Creating a Trusted MAC Entry on a VLAN
When creating a trusted-mac-address on a VLAN and omitting the port option, the trusted MAC is
applied to all ports in the entire VLAN. However, the trusted MAC does not apply the newly added
port. You must manually apply trusted MAC to the newly added port (PD3-3625781).
90 ExtremeWare 7.3.1b3 Release Notes
Clarifications and Known Behaviors
Unconfiguring a Slot will not Remove the Ports from Network Login and Network Login
Cannot be Disabled
When unconfiguring a slot with Network Login enabled on a port, Network Login is not removed.
However, the ports are removed from the default VLAN, and Network Login cannot be disabled on the
port because the VLAN does not contain the port. As a workaround, to disable Network Login on the
port, add the port back to the VLAN, and disable Network Login on the VLAN (PD3-3599531).
Proxy ARP Setting Should Take Effect When Network Login is Enabled
When the switch has a proxy ARP setting and Network Login is not enabled, the proxy ARP setting
works correctly. However, when you enable Network Login on the port, the actual MAC address is sent
back to the ARP request from the switch (PD3-3523432).
Wireless Clients Forced to Reauthenticate During Roaming
Wireless clients are forced to reauthenticate during roaming under the following conditions:
e When the default-user-vlan is set to wireless Mgmt VLAN
e When the use-dynamic-vlan is set to No in a dotlx configuration
(PD3-3514072)
Enhanced DOS Protect Rate-Limit Configurations Are Lost
Uploading or downloading configurations does not restore rate limiting for enhanced-dos-protect
rate-limit configurations (PD3-3305879).
Disable Trusted MAC Globally Will Not Automatically Remove Network Login Ports
Added as Tagged Port in other VLANs
You cannot disable trusted MAC when a Network Login port is added to a VLAN as a tagged port
without first removing the port from the tagged VLAN manually. Running the disable trusted-mac
command without first manually removing the port from the tagged port generates the following error
message:
Cannot disable Trusted MAC first remove port 1:4 from Tagged VLAN voice
You must remove the Network Login port added as a tagged port in the other VLANs before you
disable trusted MAC (PD3-2257721).
After Network Login Authentication, Cannot Get an iP Address from the DHCP Server
After campus-mode web-based network login is authenticated, the authenticated client cannot get an IP
address from the external DHCP server. When network login is removed, you can get a DHCP address
from the external DHCP server. This only applies to the Alpine FM32T switch. As a workaround, after
you unconfigure the slot on the Alpine FM32T, you can get an IP address from DHCP after
authentication (PD2-241015302).
Wireless Ports Do Not Come Online if VLAN Gets IP Address from BOOTP
If configuring the default VLAN IP from BOOTP, the wireless ports will not come online.
Workaround. Manually configure the VLAN IP (PD3-3017425).
ExtremeWare 7.3.1b3 Release Notes 91
Clarifications, Known Behaviors, and Resolved Issues
Special Characters Accepted in WEP Plaintext Key
While configuring the WEP Plaintext key, the following characters are accepted in the CLI and are also
stored as part of the key:
e - (hyphen)
e _ (underscore)
e . (dot)
For example, eg.con sec open64wep wep key add 0 plaintext a-_.. would be an accepted key.
The following character is accepted in CLI but not stored as part of the key:
e # (hash)
For example, eg.con sec open64wep wep key add 0 plaintext a-_..AHHHHHHHHHHH is accepted by the
switch, but is seen as identical to the previous example.
The following characters are rejected in the CLI:
e ~@$%*&*()+={[}] I N\s7"<,>?/
For example, eg.# con sec open64wep wep key add 0 plaintext abcd’ generates a syntax error at the ’
character.
(PD3-1853431)
A New ACL Might Not Block Packets
In certain unusual cases, a new ACL might not block packets. If you apply an ACL (without specifying
a precedence) to a port, then disable and enable the slot for that port, the ACL functions correctly.
However, if you now delete the ACL, then create a new one, it does not block packets (PD2-221267902).
Roaming Client MAC Might be Aged Out
If a network login client moves from one layer 2 switch to another switch on a different VLAN, the
MAC address might be aged out and de-authenticated, generating an error message similar to the
following (PD2-191169610):
ERROR: Port 1:3 not in vlan
False EAPOL-Flooding Alarm
If both primary and secondary RADIUS servers fail or are unreachable, you might get a false alarm of
an EAPOL-Flooding attack in the log. This is most likely to occur after boot-up with large numbers of
802.1x clients (PD2-172518964).
EAP-Failure Messages Not Sent When Client is Unauthenticated by an Administrator
If an 802.1x supplicant MAC is forced into the unauthenticated state by an administrator, an
EAP-Failure message is not sent to the client. Using the clear netlogin state, disable port, or
restart port commands can force the client into the unauthenticated state. If this happens, the client
is not authenticated, but some 802.1x client applications appear to be authenticated and can cause
confusion in troubleshooting. This problem does not occur if the client logs off (PD2-160278605).
92 ExtremeWare 7.3.1b3 Release Notes
Clarifications and Known Behaviors
Do Not Upload a Configuration Containing Authenticated Clients
In network login campus mode, do not save and upload a configuration containing authenticated
clients. Doing so can corrupt the configuration. To back up a configuration:
1 Disable network login using the disable netlogin command.
Unauthenticate all client ports using the clear netlogin state ports vlan command.
2
3 Verify that all ports are unauthenticated using the show netlogin and show vlan commands.
4 Save the configuration using the save configuration command.
5
Upload the configuration to your backup server using the upload configuration command.
When you download this configuration, remember to enable network login (PD2-142190901).
The show netlogin Output Might Display Wrong Authentication
If you disable network login, the output of the show netlogin command incorrectly displays all
existing authenticated 802.1x clients as HTTP. If you enable network login again, the display corrects.
This is cosmetic, and does not affect the actual authentication (PD2-171477134).
ICMP Access Lists and ignore-overlap
The ignore-overlap feature is not supported with ICMP access lists. Use precedence to manage
overlapping. If you specify ignore-overlap when you create an ICMP access list but do not specify a
precedence number, a precedence of 0 is assigned. In addition, the ICMP access list gives the highest
precedence to the rules created first, instead of giving precedence to the most specific rule
(PD2-157416614).
CPU DoS Protect and ACL Precedence
If you configure the CPU DoS protect feature with a filter precedence of x, you cannot create an access
list with a precedence of x, x+1, or x+2. All other values are acceptable.
If you configure an access list with a precedence of x, you cannot configure the CPU DoS protect feature
with a filter precedence of x, x-1 or x-2. All other values are acceptable (PD2-129163428).
MSM Failover Clears Logins
An MSM failover clears the Network Login state, forcing users to log in again (PD2-109075331).
Network Login RADIUS Server Interoperability
The following RADIUS authentication servers are tested and supported with Network Login:
e Microsoft Windows 2000 Internet Authentication Service
e Funk Steel-Belted-Radius Enterprise Edition version 4.0
The following authentication methods are supported with Network Login:
e PAP (web-based only)
e EAP-MD5 (802.1x only)
e EAP-TLS (802.1x only)
e EAP-TTLS (802.1x only)
ExtremeWare 7.3.1b3 Release Notes 93
Clarifications, Known Behaviors, and Resolved Issues
e PEAP (802.1x only)
Network Login Supplicant Software Interoperability
The following supplicant software applications are tested and supported with Network Login:
e Web-Based: Internet Explorer 6 web browser
e Web-Based: Netscape Navigator 7 web browser
e 802.1x: Microsoft Windows XP native OS client
e 802.1x: Microsoft Windows 2000 Professional native OS client (patch 313664)
e 802.1x: Funk Odyssey Client, version 2.0
e 802.1x: MeetingHouse Data AEGIS Client for Windows, version 2.0.5
e §802.1x: MeetingHouse Data AEGIS for Windows, version 1.3.6.1
e 802.1x: MeetingHouse Data AEGIS for Linux, version 1.1.2
RADIUS and the BlackDiamond
When RADIUS authentication is configured on a BlackDiamond switch, upon reboot, you will see the
following message indicating that the system is initializing before authentication messages will be
transmitted to the configured RADIUS server(s) (7046):
“Warning: Radius is going to take one minute to initialize.”
RADIUS and Telnet
If one of the following two situations occurs:
1 You have a single RADIUS server configured with a RADIUS timeout value of 10 seconds or more
2 Both primary and secondary RADIUS servers lose their connections and the configured RADIUS
timeout value is 5 seconds or more
The switch might not be able to fail over to the local user authentication for telnet sessions. If this
happens, the switch cannot be accessed via telnet. This does not occur with the default RADIUS timeout
configuration of 3 seconds, or when using alternate session types such as console, SSH, or Vista
management (PD2-109828821).
The show netlogin Command Output
If you remove a module with configured Network Login ports and reboot the switch, the output of the
show netlogin command incorrectly omits the configured ports. Network Login remains enabled on
the configured ports and operates correctly if you reinstall the module (PD2-92593101).
SLB and Flow Redirection
Do Not Use SLB and NAT on the Same Switch
Do not use SLB and NAT on the same switch (PD2-224957457).
94 ExtremeWare 7.3.1b3 Release Notes
Clarifications and Known Behaviors
Enumeration Mode Redirects ICMP Packets
When you create a flow redirection rule for source address based on a subnet mask of /24, enumeration
mode is selected, and all ICMP packets are redirected to the next hop. To work around this, use a
subnet mask of /16 (PD2-118471863).
Cache Servers Set To “Down” Under Sustained High Traffic Loads
Under very high sustained loads flow redirection might fail and set a cache server to the “down” state
and then bring it back up. This only occurs during high loads for a duration of more than 2 minutes.
The server will come back up immediately; however, during that time connections that were established
might be dropped due to a flushing of the associated IP forwarding database entries. A “down” state is
depicted in the log with the following message:
09/01/2000 10:51.56 <INFO:IPRT> redirect next hop test <ip_addr> changed to down
Health Checking Cannot be Disabled
Flow redirection health checking of the next hop address is turned on by default and cannot be
disabled.
NAT
Do Not Use SLB and NAT on the Same Switch
Do not use SLB and NAT on the same switch (PD2-224957457).
NAT Rule Configuration Not Updated
If you change the name of a VLAN that is part of your NAT configuration, the NAT rule configuration
is not updated. NAT rule matching continues to operate correctly, but if you save or upload the
configuration, the rule is saved or uploaded incorrectly (PD2-82963707).
Vista
Failed Vista Login Logged Incorrectly
A failed Vista login appears in the syslog with the wrong IP address and login user name
(PD2-203782108).
No 10 Gigabit Option for Port Speed
There is no 10 Gigabit option for the port speed on the port configuration page. To work around this,
use the CLI (PD2-208090014).
SNMP Community and Trapreceiver Information Not Updated
The SNMP community and trapreceiver information is not updated when you refresh the SNMP page
(PD2-208635103).
ExtremeWare 7.3.1b3 Release Notes 95
Clarifications, Known Behaviors, and Resolved Issues
Use CLI to Configure SNMPv3
You cannot configure SNMPv3 community authentication, information, or trap receivers via Vista. To
work around this, use the CLI (PD2-208635101).
Incorrect Minimum Limit on OSPF Page
The Miscellaneous Parameters on the OSPF page lists a minimum of zero for the costs and timers. The
minimum limit is one (PD2-194279901).
Cannot Create User Accounts
You cannot create a user account using Vista; you can only create admin or pppuser accounts. To work
around this, create the account using the CLI (PD2-197374642).
Cannot Enable STP
You cannot enable a STP domain using Vista. If you try, Vista does not generate an error message, but
does not enable STP. (PD2-158471801).
Alpine 3808 Erroneously Displays Four PSUs
Vista displays PSU C and PSU D on an Alpine 3808 chassis. The Alpine 3808 supports only two PSUs,
PSU A and PSU B (PD2-135911601)
Cannot Add Trap Receiver or Community String
On the SNMP configuration page, if you add a trap receiver or community string Vista indicates
success, but does not make the change to the switch. To successfully add a trap receiver or community
string, use the CLI (PD2-120713201).
Blackhole Flag Missing
The blackhole flag is missing from the FDB statistics screen (PD2-129387401).
Multicast Address Display
If you configure a routing protocol on multiple interfaces, the Vista statistics page displays the wrong
Locally Registered Multicast Address (PD2-105094265).
Configuration Statistics PSU Display
The Vista configuration statistics switch display for the BlackDiamond 6808 shows four power supplies
when only two are installed (1-D3RSP).
Vista and RADIUS
If a switch configured for RADIUS authentication loses communication with the RADIUS server,
subsequent attempts to use the Vista Web application will take a very long time (measured in several
minutes). When communication is lost with the RADIUS server, Vista will continue to make
authentication requests for every page. Each request has a timer that will expire leading to an excessive
amount of time to bring up each page (5144).
96 ExtremeWare 7.3.1b3 Release Notes
Clarifications and Known Behaviors
Configuration Options with Large Number of Interfaces
When selecting a configuration applet with a large number of configured interfaces, the traversal of the
VLAN interfaces by Vista can cause a Watchdog reset due to the task utilization of Vista during the
interface data collection. It is recommended that Vista not be used for configurations with Watchdog
enabled where the Vista Configuration applet is used with a large number of VLAN interfaces.
SNMP
Performing an SNMP Mibwalk and Polling qBridgeMIB Might Cause High Utilization
Performing an SNMP mibwalk and polling qBrigeMIB might cause high CPU utilization for the task
tSnmpd. You might see error messages similar to the following:
08/02/2004 08:36:32.66 <Warn:SYST> task tSnmpd cpu utilization is 81% PC: 80fed744
(PD3-3011496).
ESRP SNMP MIB Table Election Algorithms Missing
The following ESRP election algorithms are not included in the ESRP SNMP MIB table
extremeEsrpTable:
e ports-track-priority
e track-ports-priority
The extrmeEsrpNeighborTable should contain the following additional algorithms:
e ports-track-priority-mac
e priority-ports-track-mac
e priority-track-ports-mac
e track-ports-priority-mac
e priority-mac-only
e ports-track-priority
e track-ports-priority
(PD2-244686415)
The configure snmp community Command Replaced
The configure snmp community command has been replaced by the configure snmp add
community command. Though you can enter the configure snmp community command, it has no
effect (PD2-225385999).
Only Warm Start Smart Trap Sent After Power Cycle
When a switch is power cycled, only a warm start smart trap is sent. Previously, a cold start smart trap
was sent (PD2-209311102).
ExtremeWare 7.3.1b3 Release Notes 97
Clarifications, Known Behaviors, and Resolved Issues
extremeVlanGlobalMappingTable Exists only for Backward Compatibility
The extremeVlanGlobalMappingTable exists only for backward compatibility and has no specific value
(PD2-204237301).
ExtremeEapsTable Not Browsable
The ExtremeEapsTable is not browsable. It is used only for SNMP traps (PD2-176373732).
MIB Does Not Differentiate Between 110 and 220 VAC
The Inputpower MIB attribute does not differentiate between 110 VAC and 220 VAC PSUs in
BlackDiamond 6804, BlackDiamond 6816, Alpine, or Summit switches (PD2-199834514).
The trapDestOwner is Required in the trapDestTable
ExtremeWare 7.1 (and later) requires the trapDestOwner in the trapDestTable to send the community,
address, owner, and status in the create request for the trapreceiver entry through SNMP
(PD2-126200001).
Cannot Delete Default Community Strings
You cannot delete the default community strings (public and private) using the configure snmpv3
delete community command. To delete these strings, use the configure snmp delete community
command (PD2-153687501).
Do Not Configure an SNMPv3 Community String with more than 32 Characters
You cannot configure an SNMPv3 community string with more than 32 characters. If you download a
configuration containing such a string, that line in the configuration fails, returning the following error
message to the console (PD2-150132207):
ERROR : SNMPV3 Community Creation Failed
The rest of the configuration loads correctly.
Modular Switch get Error
A get request from an NMS to a modular switch for the if{Mau<object> on the management port returns
a “no such instance” error (PD2-124250702).
SNMP and ACLs
Polling the ACL table with a network manager can cause high CPU utilization. For example, with 1,000
ACLs, CPU utilization could be as high as 95%, which could make the console unresponsive
(PD2-57475201).
Incrementing the Interface Value
With a getnext or bulkget on a non-existent iflnde
…[truncated]