USER MANUAL 


www.fmuser.org 


STL10 
FM STL TRANSMITTER / RECEIVER 
INTRODUCTION 


The STL10-xxT is a solid-state wideband FM Transmitter providing a continuously 
variable RF output form О to 25 watts into a 50 Ohm load at many frequency within the 
UHF/ VHF band in 10 kHz increments. 


The STL10-xxR receiver uses the same synthesized oscillator as the transmitter. A 
comb line band pass filter ensures image-frequency rejection exceeding 60dB. The 
achieved sensitivity in mono is around LOmvV per 60dB of SNR. low noise and distortion, 
and high interference rejection. 


With full range universal power input and built-in active PFC function. Those STLs can 
operate on either 90 ~ 264VAC / 47~63Hz or 127 ~ 370VDC as mean power to suitable 
most of Countries in the world. 


Digital & Microwave System (D&M) has designed and manufactured broadcast 
equipment since its incorporation in 2000. Our product line has consistently applied the 
best in current technology to the specific needs of broadcasters. 


FEATURES 


Ф Easy and direct programming of the frequency by LCD, Step 10 KHz. 

Soft-start from RF mute status. 

Adjustable power output from О to 25 W with automatic power control, maintaining the 
output at any fixed level. 

Available with External AUX/MPX input connectors. 

Meets or exceeds all FCC and CCIR requirements. 

High reliability provided by conservatively rated components. 

Modular layout with Plug-in, easy replaceable circuits and parts. 

Built-in stereo coder. 


www.fmuser.org 


SAFETY FIRST! 


IMPORTANT: In order to avoid risks to personnel in the installation, utilization and 
maintenance of units, the following safety procedures and guidelines will be followed. 


Improper use or installation of this apparatus could cause serious damage to objects 
and people alike. Therefore it is essential to rely on an installer who has been previously 
authorized or approved by D&M or by our local representative and that both the user and 
the installer read the whole manual before carrying out any operation. 


Failure to apply these guidelines can lead to situations in which legally applicable safety 
standards are not met. In these cases, D&M shall be exempt from any responsibility. 


All units will be properly grounded, through the network wire or through a special 
ground wire for this purpose. The ground should meet guidelines applicable to low voltage 
systems. 


Do not use units in areas containing an explosive atmosphere, or where inflammable 
gases or smoke may be present. 


Fuses blown as a result of short-circuit must be replaced with new one of the same 
value and characteristics. Repaired fuses must never be used. Fuse sockets should be 
checked to ensure that they have not been damaged. 


Do not make any modifications to units. Any modification can lead to additional 
dangers that cannot be controlled. 


Do not use inflammable products, which can lead to a risk of fire. Do not use solvents 
that may damage the paint surface, markings or lettering. 


Maintenance personnel must not remove unit covers without taking required protective 
measures. Any manipulation must always be carried out by qualified or maintenance 
personnel. Appropriate precautions must be taken even when the unit has been 
disconnected: the inside of the unit may still have a dangerous voltage level. 

1 MAINS VOLTAGE MAY KILL !!! 








www .fmuser.org 


TECHNICAL SPECIFICATIONS 


TECHNICAL CHARACTERISTICS for TRANSMITTER 


Frequency гапге........................ 


Output 
Output 


РО%УеГ,. уана ананна 


Соппестог....................... 


Frequency Stability.................... 


Spurious Signal Emission................ 


Base band Frequency Response....... 


Stereo Ѕерагаїіоп......................... 


Total Harmonic Distortion................ 


Signal-to-Noise Еаїїо..................... 


Nonlinear Сго$5їа!К........................ 


Sub сһаппе!-<о-Маїп...................... 


Modulation Capability.................... 


Modulation Input Levels.................. 


Input C 


Mains power supply requirements... 


оппес1ог$........................... 


Operating temperature гапге...... 


Оїтеп$ї0П$............................. 


200.00 to 220 MHz /240 to 260 MHz / 300 to 320 MHz / 320 їо 340 MHz / 
400 to 420 MHz / 460 to 470 MHz / or other frequency on demand. 
25W MAX /250W MAX 

50 ohm, Type N female 

+ 0.0002%, 0°C to + 50°C 

60 dB below maximum carrier power 

+ 0.1 dB or better, 50 Hz to 53 kHz. + 0.3 dB or better, 

30 Hz to 100 kHz, the 3 dB roll off is approximately 220 kHz. 
> 55 dB at 1 kHz modulating frequency 

0.02%, 75 usec de-emphasis 

80 dB below +75 kHz deviation, 75 usec de-emphasis 

50 dB or better 

60 dB or better 

Stereo channel and MUX input for RBDS, SCA, or MUX 
Composite: 3 Vp-p into 2k ohms for + 50 kHz deviation. 

BNC and XLR 

90~264VAC; 127~370VDC, Full range universal input 

-10 to 45 ‘С 

483 x 89 x 400 mm, rack std. 19” 2U (STL10-25W) 

483 x 132.5 x 400 mm, rack std. 19” 3U (STL10-250W) 

6.5 Kg (STL10-25W), 16.5 Kg (STL10-250W) 


TECHNICAL CHARACTERISTICS for RECEIVER 


Frequency гапге........................ 


RF Input Connector ................... 


Ѕепѕіїіуіу........................... 


Stereo Ѕерагайоп...................... 


Total Harmonic Distortion......... 


Crosstalk (Mux-to-Main) ............ 


Signal-to-Noise Ваїіо.............. 


АС ромег.................................... 


Operating temperature range.... 


"Рітепѕіоп...................... «ааа 


The same with transmitter above 

Type N Female, 50 ohm 

30 mV for 60 dB SNR, 400 mV for 80 dB 

50 dB at 1 kHz, 40 dB or better at other frequencies 
0.05% with 75 usec de-emphasis 

50 dB or better 

75 dB with 75y sec de-emphasis at maximum deviation. 
85~264VAC; 120~370VDC, Full range universal input 
-10 to 45 С 

483 x 89 x 320 mm, rack std. 19” 2U 

5 Kg 


www.fmuser.org 


FRONT PANEL 





All FMT-Series digital front panels are pretty similar; they all carry the LCD display and 
function keys for operation control. 
The power-on switch with internal mains signaling lamp is on the right. 


www.fmuser.org 


REAR PANEL CONNECTORS 


AUDIO INPUT 
90~264V AC EXTERNAL) 
50/60 Hz 80VA 
RIGHT \ И 
ВЕ 2 10-100000 Hz 
OUTPUT ) AUX 
50 OHM Nw Й 


FUSE 3A/250V = 20-100 KHz 
N / О 





ЕАВТН 





AUDIO OUTPUT 
MONITOR 


90~264V AC 
50/60 Hz 80VA 


RIGHT \ 
ANT. ( МРХ 


FUSE 3A/250V Е 20-100 KHz 


~ EARTH á 


All STL input and out put are allocated on the rear panel. They are: 


© The audio channels sockets on balanced female XLR-type connectors. 

© The wide-band external processed / stereo composite signal input/output on a 
grounded, unbalanced BNC connector. 

ө The low-frequency limited (20k~100kHz2) auxiliary channel input on a 
grounded, unbalanced BNC connector for transmitter. 

ө The RF antenna connector, N-type. 

© The hot center-pin on the “EXTERNAL” BNC input in physically in parallel 
with the signal + input (pin3) on the mono/right channel XLR socket. For 
this reason both connectors cannot be used at the same time. 

© This panle also carries the IEC-type mains socket with fuse and an earth 
screw for system earthing, besides the ground ping on mains socket. 


www .fmuser.org 


INSTALLATION AND USE 
STL TRANSMITTERS 
FOREWORD TO INSTALLATION 


Install the transmitter in a dry, vented, dust-free environment, with a mean 
temperature of +10~+35 °C. Do not install on surfaces or racks subjected to vibrations, 
external vibrations can impair S/N ratio. 


Connect your audio source using suitable cables and connectors. 


The STL10 Series audio circuitry is similar to hi-fi equipment and should be installed 
and wired with the same attention; avoid earth loops as much as possible. When these 
conditions are met, the transmitter will deliver excellent audio characteristics. 


The STL10 Series are fully RF shielded and can be installed close to the production 
studio, this type of installation allows constant monitoring of audio levels, deviation and 
power parameters. The transmitter can also be installed in other locations away from the 
studio and connected with several meters of LF co-axial cables with no adverse effect on 
modulation quality. Remote installation usually requires STL (Studio to Transmission Link 
equipment). 


Final modulation performance is based upon the system installation, give careful 
consideration to where you will locate the transmitter. Additional advices are given in 
the appropriate paragraphs in this manual to assist you to achieve an optimum 
environment. 


www -.fimuser.org 


RF CONNECTION 


Connect the N type output connector, marked "RF OUT" to the antenna system with 
top-grade 50-ohm shielded cable. 


Note: Although most 50-ohm specified cable has enough power management 
capability, its power attenuation can be too high and may excessively lower the power 
available to the antenna. For this reason use only low-attenuation type cable; we suggest 
RG213 cable or in certain applications, where the power is over dimensioned or the cable 
length is small, RG58 cable can be used. Times Microwave, Cell Flex, Andrews all 
manufacture high quality low loss coax. 


POWER UP 


1) Connect transmitter to mains, check the ground, switch on. 





Menu will display the model and firmware version. “Our ODM Series will display the 
customer’s information” 
If this is the first boot or you need to change the systems configuration select “No” by 


pressing the > button. If no changes are made the unit press the “set” button unit will 
perform a 10 second internal self test, once complete the LCD will look like this: 


www.fmuser.org 





Initially, the PLL requires sometime to lock onto your frequency. During this phase 
the LCD will display “UNLOCK” and “**INH** PLL UNLOCK” alarm. 


Once locked onto your frequency the display will show “LOCKED” and “NORMAL 
STATE”. At this point the transmitter will begin delivering power to your antenna. 





www .fmuser.org 


SETTING FREQUENCY AND TRANSMIT POWER 


From the main menu, press “SET” for 3 seconds, the LCD will display the setup 
mode. You should see FREQ withthe [ ***.**MHz ] in blocks. 


Use “A” “Y” keys to change frequency, press and hold for fast forward, for fine 
tune press and release. You can select any frequency in 10 kHz steps. 


® © 





tim. © 1s 


Once you have set the frequency use the “<” “>” keys to change to the next 
parameter. This will display the output power “PS” with the PS in [0 ] blocks use the 


“А” “Y” keys to set the power from zero to maximum. Power output is displayed 


as “FWD:” reflected power is displayed as “REF”. 


Correct operation will be within a range where the reflected power should be less 
than 10% of the forward power. In the event your reflected power exceeds 10% you 
should immediately inspect all connections, coax cable/feed line, antenna connection 
or antenna match/tune. 


Check the transmitter's maximum output power does not harm the downstream 
amplifier stage (if any). If needed, set output power to the minimum. 


Once you have finished setting the frequency and power press “SET” for 3 seconds 
again; this will save your new settings to the unit’s memory. All parameters will be 
saved even during a power outage or reboot. 


www.fmuser.org 


Usethe “A” “W’ keys to move їо the next display parameter. 





Next, we will repeat the setup mode in the audio display, press “SET” for 3 
seconds or until you see the [ ] blocks. 


Тһе [ ] blocks will be in “MODE” area. Use the “A” “WV” keys to change from 
Stereo to Mono, when you have selected stereo/mono press the “№” key, this will 


advance the selection to “PR” change the pre-emphasis by pressing either “A” 

“Y” keys, now press the “>” key the blocks will advance to “LIM” the units on-board 
limiter, to make changes press the “А” “WV” keys, press the “>” key once more 
and it will highlight the L/R: Audio input level, use the “А” “WV” keys to select the 
audio level, now press the “>” key once more the blocks advance tothe “A” 
section, “Auxiliary Channel” againusethe “A” “WV” keys, to make your 


selection. Once finished remember to press “SET” for 3 seconds for the new 


parameters to be saved to the units memory. The digital menu display system is very 
easy to understand and you will become familiar with its functions very quickly. 


www.imuser.org 


LF CONNECTION 
Pre-emphasis setting “PR:” 


Low frequency and stereo channel signals have to be adequately "pre-emphasized". For 
this purpose, select the setting “PR” and choose О, 25, 50, and 75us. Factory preset is 
50us. (Europe/Pacific/South America). USA requires 75us. When using an external 
processor that employs pre-emphasis you must set the “РЕ” to О. 

If you need to alter the setting, select and adjust the “PR” to the required parameter. 


“ту, 
=- © 





AAA AAA ММА, BAA QAR QR 


LF wiring and impedance selection 





The STL10 Series supports 
balanced/unbalanced signals with selectable 
input impedance. 


The audio inputs can be set to 600/10K 
ohm resistive impedance; factory preset is 
10k ohm. They can be connected to the 
balanced output of a professional mixer or to 
the unbalanced output of a low cost unit 
without appreciable degradation. 


Selection of the input impedance is done 
by jumpers JP1 and JP2 on the input board 





www.fmuser.org 


shown to the right; Impedance selection is silkscreened on the component mask of the 
board. 


LF audio mono or stereo input employ " XLR" female connectors, use balanced coaxial 
cable connected to pin 3(+) and pin 2(-). Connect the ground of the driving equipment to 
pin 1. 

In case of unbalanced drive, input pin 2 shall be 
AUDIO INPUT short-circuited with ground and shield on pin 1, while the 


=x(PUSH)—— signal shall be available on pin 3. 





Уа А 
ке" рар High impedance selection. 5K ohm instead of 10K ohm. 
БУ ОЗО } 
Е Wee With a balanced audio signal, the audio cables can be 
——(s¢ ) гип for 100 meters. 
GUSH Ж MPX ог an externally processed signal, usually an 
Fee Ee “М unbalanced signal, сап be supplied to the female BNC 
LEFT { A Ò) \| connector, marked "EXTERNAL", which is internally parallel 
>) Axe ил J / wired with the mono /right channel connector: for this reason 
“4. it is not possible to connect signals to these two connectors 
т) at the same time. Higher impedance position is 5K ohm in 
сна раа this case. 
2 Signal – f 2 A) Connect this input with a 50-ohm (RG58) cable up to 3 
єй... Ж. хе 39) meters’ distance; if the distance exceeds several tens of 


meters, use 75-ohm (RG5QY) ог 92-ohm (RG62) cables. 


The auxiliary-channel connector, also of the BNC female type, is ground as usual. Use 
50-ohm (RG58) or 75-ohm (RG59) cables to connect to the driver. 


LF input level range, setting and requirements 
In the following paragraph we will refer to О dBm as the audio signal which produce 


1mW оп 600 ohm, і.е. а 775mVrms / 2200 mV pp sine. Irrespective of the impedance we 
will continue to assume OdBm as a LF signal whose peak is + (or-) 1100 mV. 








www.fmuser.org 


In the same way, when discussing the modulation, we will assume a OdB signal 
produces 100% maximum modulation, i.e. 75 kHz deviation. 


There is no absolute world-wide standard regarding LF peak level as a modulation 
signal for a transmitter, nor for the mean deviation. Many Broadcasters use O or +6 dBm as 
LF peak level for 100% modulation, USA often uses +10 dBm. 


Many European countries specify +6dBm for 40 kHz deviation (which is assumed to be 
a "mean" modulation). This allows for 5.5dB headroom to max 75 kHz deviation, i.e. +11.5 
dBm. 


Higher level audio inputs and ambient noise: 

High levels will stress the input circuitry of the transmitter, reducing the dynamic 
distortion-free range over the nominal level (headroom). It will also reduce the quality of 
audio. For this reason we recommend, whenever possible, to adopt a +6 ~ +10 dBm as 
nominal peak level for audio modulation purposes. 


The 57110 Series transmitters allows an input level range оп the main channel of-9 ~ 
+6 dBm to be set for 100% modulation, with almost no difference in modulation 
performances, if a high quality signal is provided. Even at the higher level, +6 dB minimum 
headroom is allowed (i.e. up to 150 kHz deviation, with no distortion). Obviously this 
deviation is not currently allowed by the broadcast standards and the limiter threshold 
must be set at its maximum to permit undistorted performance. 


The auxiliary channel's gain lies within -6 and -24 dB, with respect to O dBm and 100% 
modulation; this input's maximum applicable level is О dBm (775 mV rms). 


Typical input levels for an SCA-type signal (10% max. admissible deviation) may lie in 
the -9 to О dBm range (245 - 775 mV rms / 696-2200 mV pp), when the gain is set 
between -9 dB. Typical-input levels for an RDS-type signal (max. admissible peak deviation 
2 kHz) may lie in the -21.5 to -11.5 dBm (185 ~ 585 mV pp) ranges, when the gain is set 
between -9 dB as above. 


The nominal input level to O dB modulation may be set with good precision on audio / 
stereo composite channels, by change the gain to reach the wanted level. 








www.fmuser.org 


The auxiliary channel level is much more difficult to be precisely set, due to the wider 
range of the continuously variable control, 18 dB vs. 4 dB. Nevertheless dB control is easy 
to be set when applying the nominal signal from an external generator, whose level is 
known, and regulating it to display the wanted modulation on the modulation meter. 


The transmitter’s internal limiter is of the peak-clipping type; this means that as soon 
at it cuts in, modulation distortion increases sharply. For this reason, the modulation signal 
should be kept under control to prevent intervention of the limiter. 


5 © 






оо 66 4244 UUAA ьо ье 
The cut-in limiter threshold is factory preset to +2.5 dB (100 kHz peak value). It may 

be set from О dB (75 kHz) апа more than +6 dB (150 kHz). This threshold value is mostly 

specified in the various national standards, and tolerance to short over-modulating peaks 


varies from country to country. 


In any case, the modulation peak value that is internationally admitted for FM is 75 
kHz for peaks that are not extremely short. For this reason, the limiter's cut-in threshold 
should never be too high. It is highly recommended to use an external multi-band limiter to 
optimize modulation, with higher tolerance for any audio-signal peaks. Such devices 
momentarily reduce the amplifier circuits' gain if the threshold is exceeded and prevent 
severe, significant distortion. 


Any external compressor, limiter or audio meter must be frequency compensated with 
the same time constant of the pre-emphasis to modulate or monitor deviation properly. 


Therefore, the audio level shall be constantly and correctly monitored and adjusted, to 
prevent as much as possible, the internal limiter from cutting in. On the other hand, the 
audio level should be as high as possible, to achieve the best on-air sound. 


-15- 


www.imuser.org 


The tendency to over process the audio signal is common with local broadcasting 
stations: some sort of processing is advisable and we recommend using a top grade 
multiband compressor but not as to compress the signal to a point that impairs the original 
dynamics. 


The audio response of the STL10 Series is very flat, without perceivable loss on low 
and high audio frequency: for these reasons large frequency alterations of the audio 
signal supplied by using a so-called "frequency equalizer," are not advisable. An 
increase of the low and high frequency contents of the audio signal by more than a 
few dB can cause general degradation of modulation dynamics and improper 
functioning of the limiter. 


www.tfmuser.org 


OPERATION 


Stereo Broadcasting with 2 Input Audio Channels: 
1) Wire the XLR-type modulation input connectors, marked "Left" (channel) and "Right" 
(channel), to the output of the two channels 


from the mixer or stereo source. 


2) Change "MODE" to "Stereo". 


Mono Broadcasting, from a monophonic audio 
source: 





1) Wire the "right" (or mono) input connector to the corresponding audio source as above. 
Please note that in this case too, the signal runs through the channel(s) processors and is 
15-kHz filtered and pre-emphasized. 


The FMT-Series with internal stereo-encoder is usually factory preset to process the right 
channel input signal in the mono mode: it is however possible to use the left channel signal 
іп а similar way by moving jumper "ВО1" оп 
the stereo encoder board from position "R" to 
"L". It is also possible to mix automatically the 
left and right channels for mono by inserting 2 
jumpers in "L" and "R" on the encoder: the 
transmitter is thereby already preset for stereo 
operation if needed. 





2) Move "MODE:" to "Mono" and set "L/R: " to "Оав". 


www.fmuser.org 


Mono or Stereo Broadcasting from Radio-Link Receiver or an External Encoder: 


1) In this case, the signal is already 
multiplexed and pre-emphasized. Use the 
"External" or "Stereo" audio input. 


The signal skips the coding and filtering 
stage and therefore is not pre-emphasized. 





2) Move "MODE" switch to "External". 


Operation with a RDS or SCA Encoder 

1) Wire the BNC-type "Aux" connector to the output of the RDS or SCA Encoder, 
momentarily disconnecting any other signal, if present. Wire the pilot-tone synchronization 
output to the corresponding input of RDS encoder, if present. 


2) Momentarily move "MODE:" switch to "Mono". 


3) Adjust RDS or SCA encoder output level and /or transmitter aux level front trimmer, 
marked "aux gain", to achieve the right modulation level. 


Modulation Adjustment with broadcast signal: 

Check the modulation level for adequacy, as follow: 

1) Send a sufficiently constant musical signal to modulator input, check that the meter 
needle hovers around О dBm and moves into the red range during signal peak only and by 
по more than 1 or2dB. For any other reading, adjust the mixer's "MASTER" volume until the 
above conditions are obtained. 


The "Limiter" alarm should never or very rarely shows up as this would indicate distortion. 


If the limiter is set just above 75 kHz, the ”LIM” will shows up above OdB and the 








www.fmuser.org 


meter will never show a much greater value. Factory preset is LOOKHz (+2.5dB). 


"MODE" Switch on "Mono " and “Оав” 


In this position, the audio circuit gain of the transmitter is slightly below unity (90%) 
and corresponds to the sensitivity obtainable in the stereo position, with pilot tone which 
allows for the remaining 10%. 


Use this setting exclusively to test briefly stereo-mono switch, when no volume 
variation is desired in the modulation. In this case, for two-channel mono operation, it is 
preferable to place two jumpers in "L" and "R" at the BDI position on the stereo encoder 
board, to use both channel mixed in transmission. 


For protracted mono broadcasting, use the position "Мопо” “OdB", which permits 
correct 100% modulation with OdB level, as indicated by the internal meter. 


Low power level transmission 


The FMT-Series transmitters are not specified at power level less than 2 Watt, as with 
some power and frequency combinations (usually at less than 0.5 Watt, some 
sub-harmonic and/or spurious signals may be generated. 


Were low power level transmission was imperative, verify with a spectrum analyzer 
that the transmitter is correctly functioning at and just below the operation power: lowering 
the exciter to final amplifier power, via the exciter board power regulator, may help and 
even completely fix the problem. 


The installation of the transmitters is thereby completed. D&M wishes you success in 
your work and remind you that they are always available for further information or to tackle 
any specific problem. 


www.fmuser.org 


STL RECIEVER 
FOREWORD TO INSTALLATION 


Install the RECIEVER in a dry, vented, dust-free environment, with a mean temperature 
of +10~+35 °C. Do not install on surfaces or racks subjected to vibrations, external 
vibrations can impair S/N ratio. 


Connect your audio source using suitable cables and connectors. 


The STL10 Series audio circuitry is similar to hi-fi equipment and should be installed 
and wired with the same attention; avoid earth loops as much as possible. When these 
conditions are met, the transmitter will deliver excellent audio characteristics. 


The STL10 Series are fully RF shielded and can be installed close to the production 
studio, this type of installation allows constant monitoring of audio levels, deviation and 
power parameters. The transmitter can also be installed in other locations away from the 
studio and connected with several meters of LF co-axial cables with no adverse effect on 
modulation quality. Remote installation usually requires STL (Studio to Transmission Link 
equipment). 


Final modulation performance is based upon the system installation, give careful 
consideration to where you will locate the transmitter. Additional advices are given in 
the appropriate paragraphs in this manual to assist you to achieve an optimum 
environment. 


www.fmuser.org 


RF CONNECTION 


Connect the N type input connector, marked "ANT. in" from the antenna system with 
top-grade 50-ohm shielded cable. 


We suggest RG213 cable or RG58 cable can be used. Times Microwave, Cell Flex, 
Andrews all manufacture high quality low loss coax. 


POWER UP 


1) Connect reciever to mains, check the ground. 





Menu will display the model and firmware version. 


“Our ODM Series will display the customer’s information”, then go to normal monitor 
page. 


www.imuser.org 


SETTING FREQUENCY AND OTHER PARAMETERS 


If this is the first boot or you need to change the systems configuration, keeping 
press “<” and ”"®” button same time during power on. It will goes to service mode, 
once complete the LCD will look like this: 





You should see FREQ with the [ ***.**MHz ] іп blocks. 


Use “A” “WV” Кеуѕ to change frequency, press апа hold for fast forward, for fine 


tune press and release. You can select any frequency in 10 kHz steps. 


The frequency of STL receiver is pre-set and fix by factory due to narrow band pass filter 
inside. Only few MHz bandwidths allow adjusting. If you need to change your receive 
frequency, please info your local service or back to factory to get better receiving. 


www.fmuser.org 


Once you have set the frequency use the “<” “>” keys to change to the next 
parameter. 


This will display the MODE with the STEREO in [STEREO ] blocks, use the “A” “YW” 


keys to set the receive mode with STEREO or MONO. 


MUTE 


Use the “<” “P” keys to change to the next parameter. 
This will display the MUTE with the dBuV in [**.*dBuV ] blocks, use the “А” “YW” 


keys to set your minimum receiving level with dBuV. Lower this signal level will force the 


audio output cut off and goes to MUTE mode. 








www.fmuser.org 


AUDIO AND MPX OUTPUT LEVEL 


Use the “<” “>” keys to change to the next parameter. 








This will display the L/R with the dB in [**dB ] blocks, use the “A” “WY” keys to set 


your audio output level from -9 to +6 dB. Use the “<” “>” keys to change MPX output 
level. 





WARNING! 

OPERATION WITHOUT ANTENNA, BADLY TUNED ANTENNA, FAULTY ANTENNA CONNECTION, 
POOR COAXIAL CABLE/CONNECTIONS OR OPERATOR ERROR CAN CAUSE DEGRADATION 
AND POSSIBLE DESTRUCTION TO THE TRANSMITTERS FINAL AMPLIFICATION STAGE. 
FAILURES OF THIS NATURE ARE NOT COVERED BY THE GUARANTEE. 


www.fmuser.org 


GENERAL CONDITIONS OF SALE 


All orders shall imply acceptance of the general conditions laid out herein 
below. Where differences arise between the general conditions and the 
specific conditions stipulated in price quotations, the latter shall prevail. No 
amendments to the present conditions shall be valid without written 
approval from D&M. 


1- ORDERS 


1.1 Orders placed with D&M must be sent either in writing or by fax 
followed by written confirmation within eight days. 


1.2 Like price quotations, any exchanges of information between D&M and 
the purchaser shall not constitute a contractual agreement. The sales 
agreement shall not be binding on both parties until receipt of the 
purchaser's order. 


1.3 The cancellation or interruption of an order shall only be valid with the 
consent and written approval of D&M. Where cancellation is accepted, the 
purchaser shall be liable for payment of compensation which must cover 
the total amount of costs already incurred. In all cases, the said 
compensation shall amount to at least 30% of the total sale price. 





2- PRICES 


2.1 The prices indicated in all price lists or quotations shall be given in USD 
exclusive of V.A.T. and any other tax, except different specification in the 
quotation. 


2.2 Prices are final and shall not be subject to revision, on condition that 
the order is placed before expiry of the period of validity indicated on the 
quotation. Except where otherwise stated, this period shall be 30 days. 


3- CONDITIONS OF PAYMENT 


3.1 Invoices are drawn up on the date of delivery. They should be paid in 
full within 30 calendar days of the invoice date. Payment may be made by 
bank draft (subject to our acceptance), transfer or change. 


3.2 The order shall only be completed on a 100% advanced payment by a 
direct swift to D&M bank. Except specific term mentioned in the quotation. 


3.3 Failure to make payment on the scheduled date shall result in a 
demand for payment of all other outstanding payments. Furthermore, all 
overdue payments shall automatically give rise, after formal notice, to the 
payment of interest for overdue payments, which shall be calculated at a 
rate equal to one and a half times the legal rate of interest. Failure to pay 
may result in D&M suspending or canceling the delivery of orders in 
progress and reclaiming any goods already supplied. In this case, D&M 
shall retain the deposit paid by the purchaser by way of contractual 
compensation. Furthermore, all costs incurred in recovering moneys 
owing, in addition to any legal expenses, shall be borne by the purchaser. 


3.4 Advance payment does not give entitlement to discount. 
4- PACKAGING AND TRANSPORT 
4.1 Packaging costs are included in the price. 


4.2 Carriage costs and any taxes in the country of final destination shall be 
borne by the purchaser. 


4.3 All our goods are carried at the risk of the purchaser, who shall check 
the condition of the delivery before issuing a discharge to the final carrier. 


5- DELIVERY 


5.1 D&M shall not be liable to the Customer or be deemed to be in breach 
of contract by reason of any delay in performing, or any failure to perform, 
any of the obligations in relation to the goods and services, if the delay or 
failure was due to any cause beyond the reasonable control of D&M. 


5.2 Without prejudice to the generality of the foregoing, the following shall 
be regarded, but not limited to, as causes beyond the reasonable control of 
D&M: act of God, explosion, flood, tempest, fire or accident; war or threat 
of war, sabotage, insurrection, civil disturbance or requisition; acts, 
restrictions, regulations, bye-laws, prohibitions or measures of any kind on 
the part of any governmental, parliamentary or local authority; import and 
customs regulations, charges or seizures; strikes, lock-outs or other 
industrial actions or trade disputes by employees of the postal system, 
carriers or other third parties; difficulties in obtaining raw materials, labor, or 
parts; power failure or breakdown in machinery. 


6- TRANSFER OF RISKS AND OWNERSHIP 


6.1 Risks shall be transferred to the purchaser as of dispatch of the goods, 
including goods sent carriage paid. 


6.2 In accordance with Law, D&M shall reserve ownership of the goods 
sold until the purchaser has made full payment of all moneys due. In this 
respect, under the terms of the present provision, the remittance of bills or 
any instrument creating an obligation to pay shall not be deemed to 
constitute payment. 


7- DRAWINGS AND PRELIMINARY DESIGNS 


D&M retains full intellectual property of its designs, which may not be 
communicated to others or executed without its written authorization. 


8- INDUSTRIAL AND INTELLECTUAL PROPERTY 


8.1 Except where authorization is given, documentation and software shall 
not be copied or amended, translated or adapted into any other software 
language or foreign language by the purchaser. However, the purchaser 
may make 2 copies for filing purposes and for the replacement of a 
defective copy. 


8.2 Should the purchaser be sued in relation to a product supplied by D&M 
on grounds of breach of an industrial or intellectual property right held by a 
third party, D&M shall assume responsibility for the defense case at its 
own cost, shall conduct the proceedings and shall pay any damages 
awarded to the said third party. This commitment is subject to the 
obligation upon the purchaser to inform D&M immediately in writing of any 
claims lodged, and to leave D&M free to reach a compromise. 


8.3 Purchasing products from D&M does not imply the grant of rights 
under any patents of third parties, by license or otherwise. If the purchaser 
is not yet licensed, he shall approach administrator, as the case may be, in 
order to apply for a license, if it is necessary. 


9- WARRANTY AND LIMITATION OF LIABILITY 


9.1 The parts and any workmanship commissioned by D&M is guaranteed 
for a period of 12 months from the date of the sales invoice against 
defects, providing the goods: in the case of kits, are constructed and 
soldered properly; are not subject to use that is beyond normal/reasonable 
wear and tear; are not powered with an unsuitable power supply, power 
source or battery; in the case of transmitters are not operated with an 
unsuitable antennas or RF loads that cause damage to the output 
transistors; are not damaged from excessive over heating due to 
inadequate ventilation; any kinds of RF power transistor defect are not 
warranted. 


9.2 Qualifying goods will be repaired or, at our option, replaced providing 
the goods are returned to us, carriage paid and suitably packaged within a 
12 month period, together with a copy of the original sales invoice. To 
prevent import charges being made on returned goods from countries and 
territories outside the Taiwan, 4 photocopies of the original D&M sale 
invoice should be attached to the outside of the packaging, together with 
the relevant completed customs documentation stating that the goods 
originated from the Taiwan and are being returned for repair/replacement. 
Under no circumstances will any returned goods requiring payment of 
import charges be accepted by D&M. 


9.3 Warranty against any manufacturer's defect. Damage due to improper 
installation, overdrive, over voltage, damaged I/O pads or traces, and over 
temperature invalidate warranty. RoHS related failures or performance 
reduction are not warranted. Proper installation procedures electrical and 
mechanical must be followed. Any evidence of solder tampering outside of 
connection areas also invalidates warranty. Shipping costs are not 
covered in warranty. Minor deviations from specifications which do not 
affect the performance are excluded from the warranty. All repairs warranty 
or otherwise, require a Return Material Authorization or RMA. 


10- ATTRIBUTION OF COMPETENT JURISDICTION 


Any disputes concerning the interpretation or execution of the present 
general conditions of sale shall be referred exclusively to the Commercial 
Court in Taipei, regardless of the place of delivery or the means of 
payment accepted.