DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA) MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
www.mlamIdadeazovieconomv
Entegra Roof Tile, LLC
1289 NE SO Ave
Okeechobee, FL. 34972
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER -Product Control Section to be
used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (in
Miami-Dade County) and/or the AHJ (in areas other than Miami-Dade County) reserve the right to have this product or
material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of
such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by
Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable
building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code including
the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Bermuda Concrete Flat Roof Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in
the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall
be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No. 14-1120.06 and consists of pages I through 6.
The submitted documentation was reviewed by Gaspar J Rodriguez.
MIAMI-DADE COUNTY
APPROVED NOA No. 16-0112.07
Expiration Date: 06/07/21
Approval Date: 02/25/16
Page 1 of 6
EFTA00798399
ROOFING ASSEMBLY APPROVAL
Category:
Sub Category:
Material: Roofing
Roofing Tiles
Concrete
1. SCOPE
This approves a roofing system using Entegra Flat Concrete Roof Tile, as manufactured Entegra Roof Tile, LLC
in Okeechobee, FL as described in Section 2 of this Notice of Acceptance, designed to comply with the Florida
Building Code for High Velocity Hurricane Zone. For use in the locations where the pressure requirements, as
determined by applicable Building Code, do not exceed the design pressure values obtain by calculations in
compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be prepared
as a moment based system.
2. PRODUCT DESCRIPTION
Manufactured by Test
Applicant Dimensions Specifications
Entegra Flat Tile Length = 16" TAS 112
Width = 10" Type 3a
Class III
Trim Pieces I = varies
w = varies
varying thickness Product
Description
Flat profile, interlocking, high pressure extruded
concrete roof tile equipped with two nail holes.
For mechanical, mortar or adhesive set
applications.
TAS 112 Accessory trim, concrete roof pieces for use at
hips, rakes, ridges and valley terminations.
Manufactured for each tile profile.
2.1 MANUFACTURING LOCATION
1. Okeechobee, FL
2.2 EVIDENCE SUBMITTED
Test Agency Test Identifier Test Name/Report Date
Redland Technologies 7161-03 Static Uplift Testing Dec. 1991
Appendix III PA 102 & PA 102(A)
The Center for Applied Engineering,
Inc. 94-084 Static Uplift Testing
PA 101 (Mortar Set) May 1994
The Center for Applied Engineering,
Inc. 94-060A Static Uplift Testing
PA 101 (Adhesive Set) March, 1994
The Center for Applied Engineering,
Inc. 25-7094-2 Static Uplift Testing PA 102
(4" Headlap, Nails, Direct Deck, New Oct. 1994
Construction)
The Center for Applied Engineering,
Inc. 25-7094-8 Static Uplift Testing PA 102
(4" Headlap, Nails, Battens) Oct. 1994
The Center for Applied Engineering,
Inc. 25-7094-5 Static Uplift Testing PA 102
(4" Headlap, Nails, Direct Deck,
Recover/Reroof) Oct. 1994
The Center for Applied Engineering,
Inc. 25-7183-6 Static Uplift Testing PA 102
(2 Quik-Drive Screws, Direct Deck) Feb. 1995
MIAMI-DADE COUNTY
APPROVED NOA No. 16-0112.07
Expiration Date: 06/07/21
Approval Date: 02/25/16
Page 2 of 6
EFTA00798400
2.2 EVIDENCE SUBMITTED
Test Agency Test Identifier Test Name/Report Date
The Center for Applied Engineering,
Inc. 25-7183-5 Static Uplift Testing
PA 102 Feb. 1995
(2 Quik-Drive Screws, Battens)
The Center for Applied Engineering,
Inc. 25-7214-1 Static Uplift Testing
PA 102 March, 1995
(I Quik-Drive Screw, Direct Deck)
The Center for Applied Engineering,
Inc. 25-7214-5 Static Uplift Testing
PA 102 March, 1995
(1 Quik-Drive Screw, Battens)
Redland Technologies 7161-03 Wind Tunnel Testing Dec. 1991
Appendix II PA 108 (Nail-On)
Redland Technologies Letter Dated Aug. 1,
1994 Wind Tunnel Testing
PA 108 (Nail-On) Aug. 1994
Redland Technologies P0631-01 Wind Tunnel Testing July 1994
PA 108 (Mortar Set)
Redland Technologies P0402 Withdrawal Resistance Testing of screw
vs. smooth shank nails Sept. 1993
The Center for Applied Engineering,
Inc. Project No. 307025
Test #MDC-77 Wind Driven Rain
PA 100 Oct. 1994
Atlanta Testing & Engineering, Inc. R1.894 Physical Properties Aug. 1994
R2.894 PA 112
R3.894
Professional Service Industries, Inc. 395-40011-1 Physical Properties Feb 2004
PA 112
Celotex Corporation Testing Service 520109-1 Static Uplift Testing Dec. 1998
520111-4 PA 101
Celotex Corporation Testing Service 520191-1 Static Uplift Testing March 1999
PA 101
Walker Engineering, Inc. Calculations Aerodynamic Multiplier March 2004
Walker Engineering, Inc. Evaluation Calculations 25-7094 Feb 1996
Walker Engineering, Inc. Evaluation Calculations 25-7496 April 1996
Walker Engineering, Inc. Evaluation Calculations 25-7584 December
25-7804b-8 1996
25-7804-4 & 5
25-7848.6
Walker Engineering, Inc. Evaluation Calculations 25-7183 March 1995
Walker Engineering, Inc. Evaluation Calculations Restoring Moment, Mg March 2004
Walker Engineering, Inc. Calculations Two Patty Adhesive Set System April 1999
Nutting Engineers 13343.1 TAS 112 05/06/08
American Test Lab of South Florida RT I 210.02-15 TAS 112 12/17/15
MIAMIDADE COUNTY
AIMIKWID NOA No. 16-0112.07
Expiration Date: 06/07/21
Approval Date: 02/25/16
Page 3 of 6
EFTA00798401
3. LIMITATIONS:
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 may
required, refer to applicable building code.
3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform quarterly test in
accordance with TAS 112, appendix 'A'. Such testing shall be submitted to the Miami-Dade Product Control
Section for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
33 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable building code.
4. INSTALLATION
4.1 Entegra 'Flat' Concrete Roof Tile and its components shall be installed in strict compliance with Miami
Dade County Roofing Application Standard RAS 118, RAS 119, and RAS 120.
4.2 Data For Attachment Calculations.
Table 1: Average Weight (W) and Dimensions (I x w )
Tile Profile Weight-W (lbf) Length-I (ft) Width-w (ft)
Enteqra Flat Tile 9.7 1.33 .833
Table 2: Aerodynamic Multipliers - X (ft3)
Tile X (ft3) X (ft3)
Profile Batten Application Direct Deck Application
Entegra Flat Tile 0.189 0.205
Table 3: Restoring Moments due to Gravity - Mg (ft-Ibf)
Tile
Profile 3":12" 4":12" 5":12" 6":12" Greater than
7":12"
Entegra Flat Tile Battens Direct
Deck Battens Direct
Deck Battens Direct
Deck Battens Direct
Deck Battens Direct
Deck
6.53 6.97 6.43 6.86 6.29 6.71 6.14 6.54 5.97 6.35
MIAMI.DADE COUNTY NOA No. 16-0112.07
Expiration Date: 06/07/21
Approval Date: 02/25/16
Page 4 of 6
EFTA00798402
Table 4: Attachment Resistance Expressed as a Moment - Mf(ft-lbf)
for Nail-On Systems
Tile
Profile Fastener Type Direct Deck
(min 15/32" plywood) Direct Deck
(min. 19/32" plywood) Battens
Entegra Flat
Tile 2-10d Ring Shank Nails 30.9 38.1 17.2
1-10d Smooth or Screw
Shank Nail 7.3 9.8 4.9
2-10d Smooth or Screw
Shank Nails 14.0 18.8 7.4
1 #8 Screw 30.8 30.8 18.2
2 #8 Screw 51.7 51.7 24.4
1-10d Smooth or Screw
Shank Nail (Field Clip) 24.3 24.3 24.2
1-10d Smooth or Screw
Shank Nail (Eave Clip) 19.0 19.0 22.1
2-10d Smooth or Screw
Shank Nails (Field Clip) 35.5 35.5 34.8
2-10d Smooth or Screw
Shank Nails (Eave Clip) 31.9 31.9 32.2
2-10d Ring Shank Nails1 50.3 65.5 48.3
1 Installation with a 4" tile headlap and fasteners are located a min. of 2W from head of tile.
Table 5: Attachment Resistance Expressed as a Moment Mt (ft-lbf)
for Two Patty Adhesive Set Systems
Tile
Profile Tile Application Minimum Attachment Resistance
Entegra Flat Tile Adhesive 31.33
2 See manufactures component approval for installation requirements.
3 Flexible Products Company TileBond Average weight per patty 13.9 grams.
3M' 2-Component Foam Roof Tile Adhesive AH-160. Average weight per patty 8 grams.
Table 6: Attachment Resistance Expressed as a Moment - Mt (ft-lbf)
for Single Patty Adhesive Set Systems
Tile
Profile Tile Application Minimum Attachment
Resistance
Entegra Flat
Tile 3M" 2-Component Foam Roof Tile Adhesive AH-160 118.94
3M 2-Component Foam Roof Tile Adhesive AH-160 40.46
4 Lame paddy placement of 45 grams of 3M' 2-Component Foam Roof Tile Adhesive AH-160
5 Medium paddy placement of 24 grams of 3M' 2-Component Foam Roof Tile Adhesive AH-160
MIAMI.DADE COUNTY
APPROVED NOA No. 16-0112.07
Expiration Date: 06/07/21
Approval Date: 02/25/16
Page 5 of 6
EFTA00798403
5. LABELING
All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen below or following
statement: "Miami-Dade County Product Control Approved".
ENTEGRA FLAT TILE LABEL (LOCATED ON UNDERSIDE OF TILE)
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or the applicable Building Code in order to properly evaluate the
installation of this system. This Notice of Acceptance on its own cannot be used to obtain a building permit.
PROFILE DRAWING
ENTEGRA "FLAT" CONCRETE ROOF TILE
I- 16'
10'
MIAMI-DADE COUNTY
APPROVED FIELD TILE
END OF THIS ACCEPTANCE
NOA No. 16-0112.07
Expiration Date: 06/07/21
Approval Date: 02/25/16
Page 6 of 6
EFTA00798404
📷 Images in this document (6 detected)
AI-generated factual descriptions of embedded images (llava:13b). These are searchable across the corpus.
[Image 1] The image shows a document with text, which appears to be a letter or a report. The document is titled "NOTICE OF APPROVAL" and is addressed to "PENNY BAY CONSTRUCTION LLC." It mentions a specific project and includes a reference number. There is a section titled "DELIVERY OF CONSTRUCTION MATERIALS" with a subsection "DELIVERY OF CONSTRUCTION MATERIALS TO THE SITE." The document also includes a se
[Image 2] The image shows a document titled "Reading Assessment Application." It appears to be a form or application with various sections and fields to be filled out. The document includes headings such as "1. Applicant Information," "2. Product Description," and "3. Methods and Procedures." There are fields for the applicant's name, address, and contact information, as well as sections for product details
[Image 3] The image shows a document with a table titled "Testing Results." The table lists various companies, their names, and the dates of the tests. The document appears to be a report or summary of test results conducted by a testing entity. The visible text includes names such as "The Center for Applied Engineering," "National Technologies," and "Waterous Engineering." The dates range from the 1990s to
[Image 4] The image shows a document with a table of data, which appears to be a test report or a technical specification sheet. The table is divided into columns with headings such as "Test Name," "Test Type," "Test Conditions," "Test Results," and "Test Date." There are numerical values listed under each column, indicating test results or specifications. The document is a formal piece of paperwork, likely
[Image 5] The image shows a document with text and a table. The document appears to be a form or application, possibly related to a medical or health-related service. The text includes instructions and a section titled "Table average weight W/W/D/T" with a table below it. The table has columns with headings such as "Table," "Weight," "W/W," "D/T," and "W/D/T." There are numerical values in the table, indica
[Image 6] The image appears to be a scanned document, specifically a page from a technical manual or a patent application. The document contains text and diagrams related to a building system or construction method. The visible text includes headings such as "Building System" and "Building Performance," along with subheadings and bullet points detailing specific aspects of the system or method. There are al