Solar Portable Water Purification TMS Survivor 300 User Manual E

Survival, Water, Medical Field Manuals

Military Manuals

Document text

< Water Systems 
Swiss Made F 


User Manual 


Original 


Trunz Mobile System - Survivor 300 





Name of the machine: TMS - Trunz Mobile System 
Series, Type: Survivor 300 

Year of construction: 2012 

Manufacturer: 


Trunz Water Systems AG 
Ahornstrasse 1, CH-9323 Steinach, Switzerland 
Phone: +41 71 447 85 45 , Fax: +41 71 447 85 46 , Email: [email protected] 


Please keep for future reference! 


Trunz Water Systems AG  www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 1 von 52 


TRUNZ 


User Manual Survivor 300 Ql water systems 


Table of Contents 


1 USer TAS UIC NO INS a E E A 3 
1.1 Scope of Document, Validity ......... cee ccccccesseceecceeeeeceeeceeeseceeeeseeeeeeeesseaeeeeessaaseeeessaaeeeeeessaganss 3 
12 Representation of Safety Instructions ............cccccccecsseeeceeeceeeeeeeeeeeeeseeeeeeseaeeeeeeesaeeeeeesaaeeeeneeeas 4 
2. General Safely Insiru HONS iea a aa A aaa ai 5 
2.1 MENCO UOO eaa E E E E E E E E e E 5 
2.2 Technical DANA ss cricucerasaiusacsdetictsanessitonjeaentanasisnintannialhsaiatstiventicersecesalabotadinasote strates faiai Si 6 
2.3 Reasonably foreseeable MISUSEC.............ccccccseseecceeceeeeeceeeeaaeeeceeeeeaeeeceeessaaeeeeeeesaaeeeeesaageeeeeeeas 6 
2.4 REMAINING RISKS ...........ccccccceeecceceeeeeeeseeeeecaeseeeeseeeeeeseueeeeeeaueeesseeeeeeeaeeeessaneesseneeessegeeeesseneeeeas 7 
2.5 Obligation Of the USEF 00.0.0... ceecccccecccesseeeeeceeeeeeseeeeeeeeeeeeeseeeeeeeeeeeeeeaeeeseeeeeeeesesaaaeeeeeeeesaaas 7 
2.6 Responsibility & Qualification of the Staff... ccc ccccccccccssssseeeeeeeeesseeeseeeeeeeeesaeeeeeeeeeesssaeaeees 7 
2.7 Personal Protective E QUID MC ia daresitsts cansnaxvedaietaveadavetéamocravsiadeintinaceiaadiedsatiscancnedendmetts sedneniios 8 
2.8 Safety- and Protection D@VICES..............cccccccccccasseeceeecaeeseceecceeuseeeeeeseaeeeesssaueeeesaaaeeeeessaaaeeeess 8 
3. Description OF the Machine  casecsticeseccsecetncccseteccccasteraenssecdeanewendadxsnceteinewensenstiuadenbuwtadnconacateeaasence 9 
3.1 Design of the Machine & Process Flow Diagram ............ccccsesecccsseeeeeceeeeeesseeeeeseeeseseeeeeesaees 9 
3.2 Process Description rae caaite tee tentemenenteh manenetdandoaneaendanediandetusscacauntdhenetiieecswentteatantee dened axmiats 10 
3.3 Devices and COMPONENMS.............ccccccssseeccceeesseceeecceeeeeeecsaeeeeeeesseaseeeeessaeeceessuaaeeesssaegeeeeseaas 12 
3.3-1 Ultrafiltration Module M1 ssrrsrcrirsesirsriiiissreneeneas aara rae ETEA E EEEE 12 
3.3.2 diirantraton PUMO FI eesssisea isene E eA 13 
3.3.3 Prener oN Fo sc creck cece sshcice seared A A E E 14 
3.3.4 Backflush Pressure Tank V4 sancuasvaavscartanndusssneibeunanikitenn dintsvanicuedenddesissaanisdhsnn iiawindunpxatecununces 14 
3.3.5 Acivated Carbon Filter FS aciccdccesehecsnnsencdenatexeceenasteegeveaundedcosseiesinentdetestnasscanenddezousstecmeuneee: 15 
3.3.6 Manually Valves V1 GON 2 ocienechcresinananasthanienntnichinndbsvesnctiabian siyeiaciashehcathsitamenhahiansxentsunsnend 15 
3.0.1 venting Unis VUT & VUZ cocine E EEE EE ncaimiquncmaciemanancovean 15 
3.3.8 Nanometer PH -PRES P arean TEE E TENi 16 
3.3.9 molar Charge Controler C Uscetseseceeece secccianessecescmaaadencacedenanceacenracsnes ETRE De 16 
3.3.10 Patay GCParger OZ aeron a E E EE 17 
3.3.11 BAO D a E E E 17 
3.3.12 Sel IA gare (=| E E E A E E E A E ee nee A E E E eee 18 
3.4 ACOS OM SS e E a E E 18 
4. Transport & Positioning of the Machine ...............ccsscseeeseesseeeeeeseeseeesseeeeesseeseenseeseeensensonanenses 18 
5. Installation, Initial Start Up .........aanannnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nnmnnn nnmnnn nn 19 
5.1 Preparing the System sisecc.dsccs csvedasn gesdseeccexedesves scbceeeseadeswsecbsdaagesadssacecasdeeqaweneecssexedeseei<aocueds 20 
5.2 NNN ells SUL NNO EA ET I A A AEN EA EE E A AT 21 
5.2.1 Step 1 — Start and fill the Feed Side 2.0... ceccccccceseeeeeeceeeeeeeeeseeeeeeeeeeeeaaeeeessaeageeeeseseaess 21 
5.2.2 Step 2 — Fill & Vent the Complete Unit ........... ce ccccccssseeceeceeeseeeeeseeeeeeeeseeeeaeeeeseseaeeeeesseaees 22 
5.2.3 Step 3 — Flushing the Unit / Membrane Backflush Procedure ...............ccccccceeseeeeeeeeeeeeeenees 22 
5.2.4 Step 4 — Start Up Checks ................0..ccceccceeeeecescceseeeeescceseeeeesccseeeeensccseneeessccseneeesccceeseeessccess 23 
5.2.5 Install / Replace of the Carbon Cartridge and Venting of the Carbon Filter..................0. 24 
6. Operating the SUN UO ect ectirs tte tees tae yacht a amaaa a a a Eaa 24 
6.1 Process CTO CS casa cetssaccrancecaccaqrasesescea-nuudaaenesetadda sae EREE ARETE EDEA EENE ATE orhi 25 
6.1.1 Dead- -ENO FIANO sarruses nen ARI E EEE E AE AOA EERE o EE 25 
6.1.2 Cross-Fiow FIITatiON sessuthendsanintaw seta satensnan ated statesman nA EAE EE AE ASETETAAN tiadiawtat 26 
6.2 Operating- & Monitoring Elements and System Control ..............cccccecessseseeeeeeeeeeeeeenseeeeeeees 27 
6.2.1 Operating ElEmENTS srmsiiyesrnniis inna nnani aE R E anir iE 27 
6.2.2 Monitoring Elements sissscmaniuxuiniedenctntsisaetbontsatnhateadiarsdecnsadieosidiiansesinsvesaiinbapsecinaiiettbeadscakats 28 
6.2.3 Sae leE OM Ol EE E O A E E OE nseeast 34 
6.3 Monitoring of the Water Quality 00... ccc cccccccccccsssseeeeeeeeeeeaeeseeeeeeeeeseaeeesseceeesessaeaeeeeeeessaaaaeses 34 
7. Service, Cleaning, Maintemance..............:::::::cccsssssescccsensseeccesnnssesceennnsseaceennnsseseeennnsseseeennnseess 35 
7.1 Maintenance AVIA TIX sicensecsasdunchtinteraxatindysumtasiensckaihunnentaa pee tiienaalntedystbanheumensiencehivedaawaiedyontinn 36 
7.2 Replacement of the Carbon Filter Cartridge .............ccccccseeecceeeseeeeeeeeeeeeeeeeeesaeeeeeeseeaeeeeeeeeas 36 
7.3 Prefilter SOrviCe ............cccccccccccecccsseececccsseccccscceseeeesccceceecesecnseseeesscusneeeesscusaeceeseceseeeeessceseeeeeses 37 
7.4 Chemical Cleaning & Anti-Scaling of the Ultrafiltration... eeccceeeeesseeeeeesseeeeeeeessaeees 37 
T: Integrity Test ..........cccccccsseccccessceecseseeeceseeeceueeecseueceeseaseeeseaeeesseaeceeseaeeeessaeeesseseeesseseeessageees 43 
7.6 Auxiliary- and Consumables ............cccccccseeeseeeceeeeeeaeeeeeeceeeeeeeeeeeeeceeeeessaaeaseeeeeeeesseaeeseeeeesesaas 45 
7.7 Spare- and Wear Parts ...........cccccccsssseccccceeeceeecseeseeeeeeseeeeeeeeeeeaeeeeesaeaaeeeeseseaeeeeesseageeeeessaaees 45 
8. Defect Location, Troubleshooting ............nsnnnunnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nnmnnn nnmnnn 45 
8.1 List Of Alarms & MalfUNCTtIONS.............ccccccccccecceceeeeeceeeeeceeeesseeeeseeeeeseueeeseueeesaeeessaeeesseeeesaneeees 45 
8.1.1 Solar Charge Controller (C1) Protection FUNCTIONS ..............ccccccccsseeeeeeeeeeeeeeeeeeaeeeeeeeeseaeees 46 


Trunz Water Systems AG  www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 2 von 52 


User Manual Survivor 300 


8.1.2 Solar Controller (C1) Error Messages ............:cseeccceccceeeeeeeeeaeeseeeeeeeeeeeeeeeeaaaeeeess 
8.2 Troubleshooting ...........ccccccseeeeceeecaeeeeeeeecaeseeeeeecaeeeeeeeessaaseeeeesaeaeeeeesaaaeeeeesssaeeeees 
9. MAKING OUU OF SERVICE sissa a E a aeaio 
9.1 Temporary Giving Up .........ceeccccccssececceeceeeeeeeeeeeeeeeeeseeeeeeesseaeeeeeesseaeeesessaaeeeeeeas 
9.2 Taking the System out of Service ..........cceceecccccesccaeeeeeeeeeeeeeeseeeeeeeeeeeesssaeaeeeeeees 
9.2.1 Long Term Storage ...........cccccccssseecececeeeseecceeeeeceeeceeeeeceeeseeueeeeesseaaeeeessaaeeeessaaaaes 
9.2.2 WV TITONIZ Soi ecteosenidce santieddaxerenset ninia ARE AAE a AENA 
10. Disassembly, Disposal.........sssnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nnna 
11. APD EROD eena E A Mereraey Al ea eae er Se senmer eneeise Henne aes 


A1 Packing List / Spare Part List (Service Kit) 

A2 Declarations of Conformity 

A3 TWB 003 Process Flow Diagram and Flow Descriptions 
A4 Control Description with Trunz Setup 

A5 Preliminary Controller Settings (Blank List) 

A6 Wiring Diagrams 


1 User Instructions 


1.1 Scope of Document, Validity 


q Water Systems 
Swiss Made F 


This here presented Operating Manual describes the functionality, the correct installation, operation, 
service and maintenance of the machine, gives important references for a safety and efficient handling with 


the machine. 
The appendixes to this operating manual are an integrated component of this document. 
This operating manual only apply for the machine mentioned on the cover page. 


The state of manual version is specified in the footer. 


Trunz Water Systems AG www.trunzwatersystems.com Version 1.0 — 07/2012 


Seite 3 von 52 


TRUNZ 


User Manual Survivor 300 Ql water systems 


1.2 Representation of Safety Instructions 


DANGER 


Referred to an imminent danger. When not comply with the informations, that will 
cause death or serious injuries for the body (invalidity). 


Designated a possible hazardous situation. 
When not comply with the informations, this may have consequences like death or 
serious injuries for the body (invalidity). 


Referred to a potentially dangerous situation. 
When not comply with the informations, this may have consequences like property 
damages and slight to middle assaults. 





References, useful tips or property damages: 


NOTICE 


Designated general notes, helpful user-tips and operating references, which have no 
influence to the reliability and health of the personal. 

Highlights helpful tips, references and informations for a efficient and trouble-free 
operating. 





Reference to bigger property damages (alternative): 


Describes a potentially dangerous situation. 


When not comply with the informations, the results are property damages. 
Advices to possible dangerous situations, what may cause property damages, when 
they do not avoided. 





Trunz Water Systems AG  www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 4 von 52 


TRUNZ 


User Manual Survivor 300 Ql water systems 


2. General Safety Instructions 
2.1 Intended Use 


This machine is a water treatment system to produce drinking water. The assembly of this movable and 
portable machine in case design is carried out complete and ready to deploy ex works. At site the treatment 
plant is to complete by electrical supply wires, water hoses or optional delivered equipments. The Solar 
Panel is to install according to Trunz instructions. The site installation will be accomplished generally by the 
customer itself and is very simple. Further questions will be answered by the manufacturer Trunz directly or 
by the site / regional sales-, service offices. 


The water treatment plant provides app. 180 liter per hour of potable water per hour from any non saline 
water source. Water sources are fresh water wells from lakes, rivers, boreholes and so on. 
No treatable fluids are waste waters from sewage plants or industrial production processes. 


DANGER 


Water, contaminated with chemical or toxic (dissolved) substances, is not to be the 
side of the intended use. For such substances are other treatment processes 
necessary. Antecedent and periodically raw / well water analyses are mandatory 
necessary to evaluate the water quality (filtration ability, toxicity, health hazards by 
unknown dissolved or undissolved substances). 


DANGER 


Antecedent and periodically fresh water analyses (bacteriological & chemical), that 
means the analyses of the treated potable water, are mandatory necessary to 
evaluate the water quality (toxicity, health hazards by unknown dissolved or 
undissolved substances). Such an examination also will give information about the 
accurate and safety plant operation in the production of drinking water. 


Trunz refuses all guarantees and responsibilities in cases of unknown water quality 
analyses, changed water sources or changed operating / environment conditions. 
In cases of changes in the plant operations or contract conditions the manufacturer 
Trunz is to consult. 


The <Survivor> may only use for the above mentioned intended use. 

The treatment of other fluids can damage the machine and may cause important 
health hazards for the staff or end customer. 

In case of operating with not allowed fluids the warranty for the device is foreclose. 
Trunz assume no responsibility in case of misuse, misapplication, abuse. 


NOTICE 


The power supply of the machine incl. voltages occurs per mains supply or 
photovoltaic power. The user can decide which power supply is useful for him. 





Trunz Water Systems AG  www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 5 von 52 


User Manual Survivor 300 


2.2 Technical Data 


Dimensions of the Case 
Weight of the Case 
Dimensions of Solar Panel 


No. solar wings / No. cells per wing 
Weight of the foldable Solar Panel: 
Filtration Technology 

Raw Water Source 

Contamination 

Size of removable particles 
Quality of produced water 
Application / Installation 

Capacity 

Prefiltration 

Membranes 


Activated carbon filter 
Power supply 

Power consumption Total 
VRLA-Battery 

Power input 

Controls 

Self priming circulation pump 
Tube / Hose package 
min./max. water temperature 
min./max. air temperature 
Optional features 
Certificates 


< Water Systems 
Swis Made F 


L x W x H, 850 x 550 x 350 mm 

51 kg, net (empty, without filled water) 

1400 x 700 mm (opened), 

Complete panel: 0,98 m? 

Effective black solar cell area: 0,7544 m? 

4/8 

5,3 kg 

Ultrafiltration 

well, river, lake, borehole, non toxic fresh water 

organic contamination, filtratable particles 

down to 0.02 micron 

99.9999% virus- and bacteria free 

local or portable 

app. 180 I/h potable water 

Strainer Basket 0,6-2,2 cm & Nylon Strainer 175 um 

1 pc. Ultrafiltration-Module, Type: Inge Dizzer S 1,5 MB 2,0 
LxD: 672 x 110 mm, PES Multibore Membranes D: 1,5 mm, 
0,02 um, 2,0 m?, 5 kg 

1 pc. Cartridge type 10", 10 - 20 micron 

power connection or solar 

average app. 40-50 W 

1 pc. Gel-Battery, 12V / 33 Ah 

12 VDC 

manually, autom. battery charging 

1 pc. Diaphragm pump Shurflo max. 6,8 I/Min, 12 V, 4,1 bar 
DN 15/ 1/2" , PVC, PE, pre-assembled, ready for connection, 5m 
0/40°C 

0/50°C 

Cleaning and Testing Kit for the UF-Module 

NSF/ANSI 61 

KTW 

TUV - EN ISO 9001:2008 


The declaration of conformity is provided in the attachments of this user manual. 


2.3 Reasonably foreseeable Misuse 


An other use as defined under 2.1 "Intended Use“ or a beyond that using is deemed as not intended and is 
prohibited. Any other using requires consultation with the manufacturer. 


Rebuilding, Reconstruction, Changes: 
In case of unauthorized rebuildings and changes of the machine determinates any liability and warranty by 


the manufacturer. 


Spare parts, Wear parts and Auxiliary products: 
The adoption or insertion of spare- and wear parts from aftermarket supplier can cause risks. 
Use only original parts or approved ones from manufacturer. 


Trunz Water Systems AG  www.trunzwatersystems.com 


Version 1.0 — 07/2012 Seite 6 von 52 


TRUNZ 


User Manual Survivor 300 Ql water systems 


2.4 Remaining Risks 


The machine is constructed and manufactured according to the state of technology and the recognised 
safety-related codes of practice. Following generally remaining risks exist and are to consider with handling 
and using of the machine. Further remaining risks are described in the respective chapters. 


DANGER 


Transport & assembling risks! 


Not professional positioned, installed and fixed units and devices can cause labour 
bodily harms. 

Offload and remove heavy boxes and machinery by a lifter or with 2 or more 
persons. Take care against fall down. 


DANGER 


Transport & assembling risks! 


Not professional positioned, installed and fixed hoses and cables can cause 
risks of falling. Do not position hoses and cables over ground on roads and ways 
if possible. 


DANGER 


Electrical risks! 


Not professional positioned, installed and fixed electrical cables can cause risks of 
electric shock. It's also possible that are cables will be damaged during long 
transports or during installation. Observe the cable insulation before installing. 


The shown pictogram (lightning) gives a reference to electrical risks. In some 
Trunz plants such labels are touched on dangerous positions. 
(prevalent on 230 / 110 V — devices). 





2.5 Obligation of the User 


The user / owner commits to permit only persons / operators which 

e are exposed with basically regulations and instructions about job safety and accident prevention 
e are introduced in the operating at the machine 

e this user manual have read and understood. 


The requirements of this manual and the local regulations for the using of such a machine are to maintain 
and adhere. 


2.6 Responsibility & Qualification of the Staff 


All persons which are assigned and authorized to operate the machine commits themselves: 
e to consider the basically regulations about job safety and accident prevention 


e to have read the safety chapter and the safety instructions in this manual and have understood them 
and to regard them 


Trunz Water Systems AG  www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 7 von 52 


TRUNZ 


User Manual Survivor 300 q asia Santen 


Qualification of the staff 


Persons | Specific Instructed Instructed Persons 
Instructed Operators with expert training 
Function Personal (Mechanic/Electric) 


Transport XK 


Startup XK 
Operating SS e X e 
Maintenance f= 
Dismounting, Disposal |XX 


Caption: X..permitted --..not required 





2./ Personal Protective Equipment 


Eye damage by cleaning chemicals! 


Cleaning agents and chemicals like acid or lye can cause eye damages. 
During all activities when chemicals will be used is to bear a protective glass and 
safety gloves. 





2.8 Safety- and Protection Devices 


The <Survivor> is a simple and manually operating filtration device. 

Especially safety / protection devices are not designed and provided. 

Nevertheless is to take care in the handling and operating procedures to avoid property damages and 
health hazards. 


Device for Emergency STOP: 


= 
aa at 


niin ANN 
MD 












HA Switch <OFF> the Main Switch. 
mi na wt EN The complete Machine stops. 

r The main switch has additionally the 
function as <Emergency Switch> 


Trunz Water Systems AG  www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 8 von 52 


TRUNZ 


User Manual Survivor 300 q sie Santen 


Swiss Made F 


3. Description of the Machine 


3.1 Design of the Machine & Process Flow Diagram 


The water treatment unit TMS Survivor 300 is designed very compact with small dimensions and weight. 
The complete machine can be installed permanent on a usable place or can also installed on a trailer or 
movable vehicle like a car-roof or a boat. 

The housing is designed in a robust and weather resistant plastic case. 

The <Survivor> is complete assembled and ready to deploy. 

The system is able to produce app. 180 |/h drinking water from various fresh water wells. 

The exact flow rate is dependent to the water pollution, particles in the raw water and the water 
temperature. 

The integrated Ultrafiltration system removes all particles and all microorganism and bacteria bigger than 
0,02 um size. In principle the water will be sterilised only by solid-fluid-separation (filtration) without requiring 
toxic or hazardous chemicals. 


The case is ideal for decentralised water purification in remote communities , clinics, resort application, 
private adventure holidays, camping etc. The system is easy to install and to maintain. A manually operating 
backflush system cleans the ultrafiltration module independent with low necessary manpower. 







<4— Solar Panel 1 m? 


External Power 230 VAC IN 
Solar Cable IN 


Drinking Water 
>A ON / OFF Switch 


Filtrate Outlet 
F3 Activated Carbon Filter 


Backflush 
Drain OUT 


Water Inlet (Feed) 


k F <Q F1 Strainer Gasket 


| <4 F2 Strainer 175 um 


C1 Solar Charge Controller 


Case 
VU2 Venting Unit (Module Filtrate Side) 


T1 Backflush Tank PI2 Backflush Manometer 


B1 Battery l cee oreo bas s a i | i l- C2 Battery Charger 


V1 3-way Filtrate Valve 
P1 UF-Pump 


Filtrate Hose 


PI3 Drain Manometer , , 
VU1 Venting Unit 


M1 Ultrafiltration Module (Module Raw Water Side) 


V2 Drain Valve PI1 UF Inlet Manometer 


Backflush 


Drain OUT > N j o uii vi Raw Water Inlet 


( Y F2 Strainer 175 um 


j ON / OFF Switch 


External Power Solar Cable IN 


230 VAC IN 


Trunz Water Systems AG  www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 9 von 52 


TRUNZ 


User Manual Survivor 300 Ql water systems 

















C1 


Solar Charge Conroller 























VAI 








R 3030 
H24V 30A 


Q) © 
















© Oo © © 





sees eesee ees Sete E ees Leese tee see ay 


pesere sed Sesd ese eee es i Seb ease eee ee ea eas Solas Sees ee ease aes 
















































































































PI2 
Manome! ter 
1% 
Hot i | 
Pg ' T4-Filling 
bate E i 
i 
B1 i V1 i 
th poki ! 3-way Ball Valve Backflush i 
Gel-Battery R B oe ! ackflus! 
12/33 AH SJE | ieee E ' = 
i i ! 
Ka Ese] i 
PIS E i i ! 
Manome: ter i eat i TI ! 
i of i T ! p 
to ! iaphragm Pump 
| | i w ' selfpriming max. 3m ; 12VDC, 7,0 AMPS 
v2 peun i | im max 6,8 l/min, 4,1 bar pz Pecce Sone 
Drain Val C m i |e aa (ae ee a ee eg oT — adjustable shut-off 2,7 - 4,1 bar 
r-t : 2 aaa i m S 3 1 
— = =| 1 i) 
= m ge P1 ine 
[==] ! 1 lii ge Dizzer $ 1,5 MB 2, ta 
iltration: e i ) [| [| e ai Bi 
Backflush: open OS = «| — i 





Raw Water 








Va 


| Permeate / 
| Product 








I Flow Restrictor 























F1 
Strainer Basket 








Drain OUT Water IN 






























































F3 
Activated 
Carbon Filter 
(10", 10-20um) 


F2 


i 
Strainer 
175 um Raw Water 












































Portable Ultrafiltration Case 





3.2 Process Description 


The process flow diagram in chapter 3.1 is showing the installed technology. 
A separate Process Flow Diagram PFD for better view is also in the appendix available. 


Water source can be fresh water (Sweet water) from well, river, lake, borehole ... etc. 


NOTICE 


The Survivor is not able for desalination of Brackish- or Seawater. 


DANGER 


Salt contents exceeding TDS 1000 ppm have influence to the taste and optic of the 
water. Higher salt contents in drinking water can cause health hazards. 
A salty water taste can be caused also by dangerous salts of heavy metals. 





Fresh water will be sucked by the self-priming diaphragm pump from the water source to the treatment 
system. Big particles, fibres, plants or water animals bigger than 6 mm will be retent by the Strainer Basket 
F1. Finer particles but bigger than 175 um will be pre-filtrated by the Strainer F2. The Strainer F2 is a 
protection device for the Ultrafiltration and has inserted a stainless steel cartridge (175u mesh screen). 
Through the transparent strainer housing is viewable the degree of fouling on the mesh screen. Maximal 
flow of the unit is designed up to app. 180 l/h. The pump is able to raise the water up to 40 m (4 bar). The 
maximum distance between water source and Survivor is limited to the standard hose length as supplied. 
The pump don't will be controlled. She has an ON/OFF Switch (main switch of the Survivor) and a maximum 
shut-off pressure switch what is pre-adjustable on the pump head. 


Trunz Water Systems AG  www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 10 von 52 


TRUNZ 


User Manual Survivor 300 Ql water systems 


The water inlet to the Survivor is located at the case front. The water flows at first through the prefiltration 
devices (strainers). 


The UF-pump P1 boost the prefiltrated water to the Ultrafiltration Module M1. 

The Ultrafiltration (UF) is a fine filtration process. Polyethersulohone (PES) membranes have a cut off (pore 
size) of 0,02 um. All particles bigger than 0,02 um can be removed from the water. Also bacteria or other 
microorganism can be separated out of the water. Water passes the membrane wall from inside to outside 
and particles will be rejected in the membrane channels. The geometry of the membrane is a multibore 
type, in this case it means that 7 membrane channels a 1,5 mm diameter are in one membrane fibre. The 
complete module has an effective filter surface of 2,0 m?. 


Trunz operates the treatment in the <Dead End> process. All water what is coming in into the module exit 
the module at the filtrate outlet. The drain outlet of the module is closed (Dead End). The filtrated particles 
will be collected on the capillary inside surface and generate a fouling layer. From time to time the 
membrane will be backflushed to clean the membrane surface. For this it will be used ultrafiltrated water 
from the backflush tank T1. The <Dead End> process is only possible with relative clean water 

(turbidity < 5 NTU). The more pollutions are in the water the more is a membrane backflush necessary. 
Other methods to operate the unit per example in cases of strong raw water pollution with many particles in 
the water are optional to use. Per example it's possible then to operate the system in a <Cross Flow> mode. 
In this mode will be opened the Drain Valve V2 a little bit during the filtration process. The flow within the 
membranes is turbulent and cross along the capillaries. The inlet pressure at the module will be reduced 
and a permanently partially waste water stream exit the UF-module on the drain side. The Filtrate flow also 
will be reduced dependent to the drain flow (Sewage quantity). The advantage of such a processing Is a 
much more longer filtration cycle between necessary module backflushes. Less maintenance, process 
monitoring and controls are necessary what would optimize the operating complexity. So it's possible to 
produce drinking water also with strong contaminated raw water with a turbidity* > 5 NTU. 

“turbidity > see also chapters 6.1 & 6.3 


The pre-conditions for a membrane flushing decides the user and is strong dependent to the well water 
quality. Recommended backflush conditions will be mentioned later in this manual. The initiating of the 
backflush will be done manually by the operator. Backflushed dirty water will be drained via valve V2 back to 
the river or lake. In case of using a borehole as raw water source the drain water can not be given back into 
the borehole. Then it is to utilize a user's sewage system or an to the local regulations allowed storage 
reservoir or pit drainage. It's conceivable that excessive drain water also can be used per example for a 
garden watering (soil irrigation). 


Monitoring of the filtration process and the documentation of all relevant process data will be managed by 
the user manually / visually (pressures, filtrate-flow, backflushing etc.). 

Mechanical but automatically working venting units on the raw water side VU1 and on filtrate side of the 
module VU2 avoid air-cushions in the module what would affect the filtration process. Ultrafiltrated water is 
hygienic clean drinking water (biologically clean) but not free of dissolved substances like heavy metal ions, 
fertilizer substances, chemical / industrial contaminations, faecal substances such as ammonium-, nitrates-, 
nitrite- compounds, salts, chlorine etc. 


For the membrane backflush will be used ultrafiltrated water from the backflush tank T1. The tank will be 
filled manually during water filtration by switch over of the 3-way backflush valve V1. The pump P1 stops 
automatically at an pre-adjusted pressure on the pump's pressure switch. The tank is filled if there is 
reached a pressure of app. 3,0 bar. To observe the pump's stop-pressure see to the Manometer PI1 & Pl2. 
3 bar water pressure deliver enough pressure for an effective membrane cleaning. An in the tank integrated 
rubber balloon with an air-pre-pressure of app. 1,0 bar assists the backflush flow. 

To initiate the backflush it is to open the drain valve V2 quickly. The system pressure drops and the water 
from tank T1 flows to the UF-module backwards. In the normal filtration process the water in the 
membranes flow from inside to outside. In the backflush cleaning mode the water flows from outside to 
inside of the membranes. The reversed water flow in the module loose the collected pollution layers on the 
membrane surface and drains the wastes to the module drain outlet. The flushing process is ended when 
the tank is empty. The system pressure is decreased to nearly 0 bar and the pump P1 starts automatically. 
The pump is running and the membranes will be flushed with a forward flush, that means that particle rests 
on the membrane surface will be flushed away to the drain. This will be done a few seconds. Then the 
operator closes the drain valve V2 and re-adjust the 3-way backflush valve V1 to the normal filtration 


Trunz Water Systems AG  www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 11 von 52 


TRUNZ 


User Manual Survivor 300 Ql water systems 


position. After the backflush the membrane inlet pressure is decreased (monitor it at manometer P11). Now 
the normal filtration and drinking water production will be continued up to the next backflush. 


Energy for the treatment system will be provided by 2 possibilities. 

The first option is an independent solar operation. An 1 m? foldable solar-module uses the natural sun 
power. A 12V gel-battery will be charged and controlled by the solar charge controller C1. With the solar- 
option it's possible to produce drinking water independent of any external power supply stations and also in 
far away regions and territories without of any electrical power sources. The system is quasi usable all- 
around where the sun is shining. The battery buffers the produced energy so that it's possible to operate the 
system for a few time in times of no sun shining. 

The second option for energy using is the installed battery charger C2. This unit transforms voltages 
between 100 and 240 VAC to the needed 12 VDC. Available external power makes it possible to operate 
the <Survivor> 24 hours per day and 365 days in the year. The battery loads will be monitored at the solar 
charge controller C1. 


NOTICE 


The Ultrafiltration is not able to eliminate heavy metals, volatile & dissolved 
substances, pesticides, herbicides, salts, chlorine, acid, lye, gases or 
particles smaller than 0,02 um. 





The <Survivor> includes an "Activated Carbon Filter" F3. The installed type is a cartridge type. Activated 
carbon particles are pressed compact in a cartridge. The small carbon particles in the cartridge are so little 
that the porosity between the particles is app. 10 -20 um. 

Activated carbon is able to eliminate chlorine, bad flavours and smells. Smell and flavour substances in 
water are mostly volatile or dissolved. Activated carbon is an ideal adsorption / absorption method to 
eliminate such substances. The carbon degenerates and lose it's activity and effectivity the more 
undesirable substances react with the carbon. The carbon cartridge is a consumable material. That's why 
the carbon filter should only be used and work in cases of really bad tastes and smells in the water. 


NOTICE 


The delivered carbon cartridge is an original manufacturer's equipment. The 
cartridge design has a worldwide trading standard size. Trunz advices the delivered 
cartridge type. The customer or user can decide for an other brand. 





3.3 Devices and Components 
3.3.1 Ultrafiltration Module M1 
a 
| = The ends of the 


membranes are casted Filtration & Backwash Principle 


in synthetic resin 
In-to-out Filtration 


—> Filtrate 
Filtration Backwash 


Feed Water ý 


Filtrate Filtrate 


Be 





ee PEs ee ee 





44444464 
DADRA AA! 
TETTIUTTY 





Multibore 1.5 mm (MB 1.5) 


app. 150 Membranes. Poewe Water 
oOo Feed Each membrane has 7 
mn capillaries (Multibore) 


Trunz Water Systems AG  www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 12 von 52 


User Manual Survivor 300 


Module 

Type: 

Module Length without EndCaps 
Module Diameter 
Membrane Area: 
Connections: 

Weight: 

Dead-Volume Retentate: 
Dead Volume Total: 
Material Housing: 
Operating Pressure max.: 
Bursting Pressure: 
Temperature max.: 


Membranes 

Type: 

Membrane Diameter: 

Fibre Diameter: 

No. of Membranes per Fibre: 
Active Membrane Length: 
App. No. of Fibres per Module: 
Pore Size: 

Membrane material: 


Technical Data 
Transmembrane Pressure Filtration: 


Transmembrane Pressure Backwash: 


Feed: 
Flux Filtration: 
Flux Backflush: 


Cleaning & Disinfection Agents 
Active Chlorine (free Cle): 


Hydrogenperoxide H202: 
Caustic Soda (NaOH): 
Acid (e.g. Citric Acid): 


3.3.2 Ultrafiltration Pump P1 





PRESSURE P.S.I. (BAR) 


Trunz Water Systems AG  www.trunzwatersystems.com 





| Water Systems 
Swiss Made F 


Inge Dizzer S 1.5 MB 2.0 
500 mm 

110 mm 

2.0 m? 

1%" 

5 kg 

816 ml 

2400 ml 
PVC-U, grey 
5 bar 

app. 10 bar 
0-40 °C 


Multibore 
1,5 mm 
6,0 mm 
7 

440 mm 
150 

0,02 um 
PESM (Polyethersulphone modified) 





0,1 — 1,5 bar 
0,3 — 3,0 bar 
< 250 I/h 


60 — 180 I/m2h (dependent to raw water quality and temp.) 
230 — 300 I/m?h (dependent to membrane fouling) 


max. 200 ppm ; max. 200'000 ppm * h 
max. 500 ppm 

max. pH 13 

down to pH 1 


TYPICAL PERFORMANCE 


PRESSURE 


FLOW CURRENT 
(PSI) (GPM/LIT) 


(AMPS) 


VOLTAGE 


RPM 
MIN/MAX (VOLTS) 


0.5 0 1.5 
(1.9) (3.8) (5.7) (7.6) 


FLOW - GALLONS PER MINUTE (LITERS PER 
MINUTE) 


Version 1.0 — 07/2012 Seite 13 von 52 


User Manual Survivor 300 


Technical Data 


Pump Design: 
Check Valve: 
Motor: 

Voltage: 
Pressure Switch: 
Max Operating Temperature: 
Prime: 

Inlet Pressure: 
Ports: 

Materials: 
Weight: 
Dimensions: 


< Water Systems 
Swiss Made £3 


Positive Displacement 3 Chamber Diaphragm Pump 
1 Way Operation Prevents Reverse Flow 
Permanent Magnet, P/N 11-111-XX 

12 VDC Nominal 

Adjustable Shut-Off Range 2,7 — 4,1 bar 

77 °C 

Self-Priming up to 3,6 m ; Dry Running Able 

Max 2,1 bar 

3/8" Female 

Polypropylene, EPDM, Santoprene, Zink Platened Steel 
2,15 kg 

210 x 100 x 95 mm 


3.3.3 Prefilter Strainer F2 


Fine screen to protect the Ultrafiltration Module / Membranes. 
Mesh Cartridge: stainless steel, 175 um 


Housing: Nylon / Plastics 

Max Temperature: 20 C at 10 bar ; 50 °C at 7 bar 
Connection: 3⁄4" 

L x D (Housing): 140 x 55 mm 

L x D (Screen): 94 x 40 mm 





Maintenance and Cleaning of the Prefilters will be described in Chapter 7. 


3.3.4 Backflush Pressure Tank T1 


TR UF Backflush Tank 
Volume: 5 Liter 
Max Pressure: 10 bar 
Air Pre-Pressure: 1,0 bar 





Pressure Tank Design 


System Connection 
Flange 

Shell 

Membrane 

Air Precharge Valve 
Top Support Fitting 

Plate Holder 

Legs 


-~Q™mImoow> 





Trunz Water Systems AG  www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 14 von 52 


Water Systems 
Swiss Made F 


User Manual Survivor 300 TRU NZ 


3.3.5 Activated Carbon Filter F3 


Type: Standard 10" Housing 
Housing: HOU-10-BR (10" Length) 
Cartridge: Pentair CTO-10 (20 um) or CFB-Plus10 (5-10um) 


LxD: 254 x 68 mm 
Flow 720 l/h at 0,7 bar 
Temperature: 4 — 70 °C 
Pressure loss: 0,8 bar 


Active Carbon eliminates bad smell and flavour in the potable water. 
Active carbon reacts with unwanted substances and will be consumed, 
that means that the carbon activity will decrease. 

That’s why is to change the carbon cartridge from time to time. 





3.3.6 Manually Valves V1 & V2 


V1 — Backflush Valve 

3-way manually ball valve 
+GF+ ; true union 

PVC-U 

Non-metallic valve internals 
DN15/ 1⁄2" 

Simple installation and removal 


V2 — Drain Valve 

= 2-way manually ball 

Rust free 

Stainless Steel 

DN15 / 1⁄2" 

Simple installation and removal 





3.3.7 Venting Unit VU1 & VU2 


Installed are 2 Venting Units VU1 for de-airing of the Retentate-side and VU2 for the Permeate-side of the 
UF Module. 


The automatic air vent purges air from liquid-filled systems. It 
is designed for use on closed hydraulic systems. It is not 
used on systems contaminated with oil or petroleum based 
additives or on steam. The maximum temperature is 110°C 
(230 °F), the maximum structural pressure 12 bar (174 psi). 
Principle is an inserted floating valve. The Red Cap is 12 
round open during filtration and will be closed manually in 
storage times of the Survivor. 





Trunz Water Systems AG  www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 15 von 52 


User Manual Survivor 300 


3.3.8 Manometer PI1, PI2 & PIS 


meen) 
| Sew 
2 | 







Bourdon Gauge 
Type: Wika 213.53.1 






fi / S 
EN 837 


thy, 


4 vri 
\\ 
^ \ 
E E E E E E E 


Housing: CrNi steel 


3.3.9 Solar Charge Controller C1 


The Solar Charge Controller has the duty to control solar 


modules and is suitable to charge 12 V or 24 V 


batteries. The controller performs constant voltage charging of 
the battery. The maximum current available from the charging 


source is used for charging the battery until the 
voltage is reached. 


The Controller C1 is configured by Trunz and usable in the 


Survivor Case. Any manipulations at the contro 


damage the Controller, the solar system or other electrical 


components. 


Technical Data 


Electrical data 

Operational voltage 

12 V voltage range 

24 V voltage range 

Permissible ambient temperature range 
Permissible storage temperature range 
Own consumption in mA 

PWM frequency 

Maximum input voltage 

Minimum battery voltage 


Currents 
Max. constant module current at 25 °C 
Max. constant load current at 25 °C 


Overtemperature switch-off 
Load switch-off 


Load switch-on 


Data on final charge voltage 
Depending on configured battery type 


Normal charging (float) 

Boost charging (boost), for 2 h 

30-day maintenance charging when necessary 
Temperature compensation 


Trunz Water Systems AG  www.trunzwatersystems.com 


i 


00 , connection down , 1⁄4" 


Nominal Size: 50 mm 
Indicating Range: 0 — 10 bar 
Permitted Temperature: max. 60 °C 


Fluid Filling: Glycerine 


rechargeable 


final charge 


PR 3030 


30 


ller can 


SOLAR CHARGE CONTROLLER 12/24V 





12 V or 24 V, automatically detected 
6.9V-17.2V 

17.3V-43 V 

—10 °C to +50 °C 

—20 C to +80 °C 

12.5 mA 

30 Hz 

<47V 

6.9 V 


30 A 
30 A 


>85 °C 
<75 TC 


Gel battery (GEL) 
13.9V/27.8V 
14.4V/28.8V 

14.4 V (28.8 V) 

—4 mV per K and cell 


Version 1.0 — 07/2012 Seite 16 von 52 


Water Systems 
Swiss Made F 


TRUNZ 


User Manual Survivor 300 Ql water systems 


Charge control activation 


Activation thresholds of the different charging modes SOC control Voltage control 
Normal charging SOC 2 70 % 2 12.7 V or 2 25.4 V 
Boost charging SOC 40 % — 69 % 11.7 V — 12.7 Vor 
23.4 V — 25.4 V 
Equalisation charging SOC < 40 % < 11.7 V or 23.4 V 
30-day maintenance charging If no compensation charging or boost charging has 


taken place in the last 30 days. 


Load disconnection 


Load disconnection advance warning SOC < 40 % < 11.7 V / 23.4 V 
Load disconnection SOC < 30 % <11.1V/22.2V 
Load reconnection SOC > 50 % >12.5 V / 25.0 V 
Mechanical data 

Degree of protection P32 

Mounting method Wall mounting 

Weight 350 g 

Casing Recyclable plastic case 

Dimensions L x W x H 187 x 96 x 44 mm 


3.3.10 Battery Charger C2 


The function of the battery charger is it to transform incoming 
voltages between 100 — 240 VAC [50/60 Hz] to battery 
conform voltage 12 VDC. Per example it's possible to use 
external power 230 VAC provided by the user to charge the 
Survivor battery. In this case it is possible to operate the 
Survivor without sun shine or indoor. 

The charger C2 is configured by Trunz and usable in the 
Survivor Case. Any manipulations at the charger can damage 
the charger, the battery or other electrical components. 





The charger is a fully automatic, electronic multi-stage on-board marine battery charger. It is pre-wired for 
easy installation and is 100% waterproof for fresh and salt water applications. It's incorporated extruded 
aluminium housing with plastic end caps. This design offers improved durability and heat transfer while 
comparing it to full plastic case competitive products. The unit offers multi-stage charging which 

includes a “float” maintenance mode that is safe for long and short term storage. The charger can be left on 
indefinitely without harming or overcharging your batteries. The distributed-On-Demand TM multi-stage 
charging technology will automatically sense and distribute 100% of the available charging amp output, i.e. 
8 amps (model specific) to any one bank or combination of all banks. Each battery bank output is fully 
isolated. 

Easy to view LED indicators will provide you with AC power on and charging status. The LED indicators can 
be seen from the front and the side of the charger when installed. 


3.3.11 Battery B1 
Type pbq 33-12LL 
Voltage 12 VDC 
Capacity 33 Ah 
Size (LxWxH) 195x130x168 mm 
Weight 11kg 
Chemical Type Pb 
Protection installed and fixed in a 





water proofed housing 


Trunz Water Systems AG  www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 17 von 52 


TRUNZ 


User Manual Survivor 300 Ql water systems 


3.3.12 Solar Panel 





| | 
f 
l | | | 
f 
f 
r 
J nt Hh 
| | 
Í | 
| 
| 
| 
Í 


Type 4-segment foldable monocrystalline panel 
Rated Power 135 W 
Rated Voltage 16,5 V 
Open Circuit Voltage 19,9 V 
Size (LxH) 1,4 x 0,7 m (0,98 m?) total 

Effective Black Solar Cell Area 0,7544 m? 
Weight 5,3 kg 


3.4 Accessories 


Accessories like hoses or consumption materials are mentioned in the 
<Packing List> and <Spare Part List> in the Attachment of this manual. 


4. Transport & Positioning of the Machine 


The Survivor case has to be installed on a plane, horizontal and solid level surface ideally on concrete. The 
case operates only in horizontal lying position. The box must have good access, must be locked against 
wind, should not stand directly in the sun or in the rain. Very important is the direction of the solar panel to 
the sun. In the southern hemisphere the solar panels should be aligned to the north, otherwise in northern 
hemisphere to the south. If available use a compass. 








The solar panel has a little adaptable framework. 
Use the framework to fix the panel on the ground. 


When unpacking and using the solar panels, 
take care to the fragile material. 


Install-example for 
northern hemisphere. 
The panel looks to the 
_ south in a 90° angel to 
XX the sun. 


NOTICE 


Transport and assembling risks are mentioned in 
chapter <2.4 Remaining Risks> 


The supplied Drain Hose (1/2" green) has a standard length of 5 m. 


Protect the machine against wind / storm, rain, 
floods, directly sun, animal or unauthorized access 
etc. 





Trunz Water Systems AG  www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 18 von 52 


TRUNZ 


User Manual Survivor 300 Ql water systems 


The Survivor has a transport weight of over 
50 kg. Wear the heavy box with 2 men or use 
a platform wagon for transport to the 
installation site. The case is equipped with 
rolls. It's also possible to pull the case. 





When unpacking the Survivor box take care 
that no parts broken or loose. Look for the 
parts and accessories to completeness. 
Compare the parts and units with the 
mentioned units in the attached <User 
Manual>. Read the user manual before 
installing and operating. 





The solar panel is fixed in the lid of the plastic case. Other parts are packed relative bulky in the case. 
The standard lengths of the supplied hoses are 5m. The case should stay in the near of the water well and 
the sewage duct. The self-priming pump is able to suck water from max 3 m depth. 


NOTICE 


The user can install an own hose with a longer hose length. But note that the pump 
priming power will be decrease with the length of the priming hose. 





In cases of chemical cleaning procedures of the filters the customers disposal duct must be in line with the 
local sewage system. Chemical cleaning solutions can have slightly acid or caustic composition. 

Normally local sewage treatment plants are able to process chemical contaminated water by biological 
methods. 


The Survivor will be supplied with 12 V power. A 230 V connection for battery charging is available. 
The customers electrical power system must meet the local regulations. 


DANGER 


Electrical risks! 


Electrical components must be positioned in dry locations, protected against external 
influences (environmental or access of unauthorized persons). 





5. Installation, Initial Start Up 


When unpacking the Survivor please check the fitting of the PVC pipes. During 


transport it can happen that they become loose/dismantled in case of vibration. 
Always turn the main switch off first before working on electrical parts. 

Always make the piping system pressure-less first before working on the 
plumbing part. 





Trunz Water Systems AG www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 19 von 52 


TRUNZ 


User Manual Survivor 300 < taste A 


5.1 Preparing the System 


Preconditions 


= The Survivor is unpacked and positioned as above described. 
= The sun is shining or an external 230 V connection is available 


Preparing the Survivor 








ADEN NEN ADAN AMAD 
17a 1—0 ED ma Hr 
TT] (ah «— [6] 


LL LLL [6A] 
IDN EDN wn AWA 





LS] — a? . [10] 
[4] — J | a, TE [9] 
[5] A 
a E PE a [1] 
2A ay 
[2A] [8] [7] 
[7] 


[1] Connect the feed hose with the Survivor (CEJN-Coupling). Press the coupling onto the nipple until 
you hear a <click>. Position the hose-end with the Strainer-Basket [1A] in the water well. 


[2] Connect the green Drain Hose with the Survivor (Gardena-Coupling). Position the hose-end [2A] in 
an allowed sewage duct. 


[3] Install the premanufactured Activated Carbon Filter. Use the long-holes in the filter bracket. 
Screw and fix the bracket with the Survivor-housing. 


[4] Install the Filtrate Hose with the carbon filter and position the hose-end in a <Product-Vessel> 


[5] Screw the blue carbon filter housing on the black filter head hand-tighten. Take care that the sealing 
in the blue housing is correct positioned. The carbon cartridge [5A] don't will be installed yet. After 
the start up of the Survivor and only if useful and necessary the carbon cartridge will be installed 
later. 


Position the Solar-Panel as described in chapter 4.0 or set it in the Survivor cover as in the picture 
[6] above. For stabilisation place the Panel behind the holders [6A]. The panel front must look ideally 
and optimal to the sun. 


[7] Connect the Solar cable [7] with the Survivor in the right power connection socket (2 pins). Connect 


the other cable-end with the solar panel [7A]. In case that the solar panel don't will be needed 
because of using 230 V main power, then the solar panel don't must be installed. 


Trunz Water Systems AG  www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 20 von 52 


TRUNZ 


User Manual Survivor 300 Ql water systems 


[8] Connect the main power cable (230 V — connection) with the Survivor in the left power connection 
socket (3 pins). If not needed the connection or it's no 230 V power available, then the connection 
don't must be installed. 


[9] The ON/OFF switch [9] is currently in <OFF> position. Don't start the system yet. The starting 
procedure will be described in the next chapter "Initial Start UP". 


[ 10 ] Check the red caps of the ventilation units VU1 & VU2 [10]. The caps must be open app. 12 round. 


NOTICE 





Electrical Connections: see also in the attached Wiring Diagrams 


5.2 Initial Start Up 


NOTICE 


An initial start up procedure is to accomplish at following situations: 
Start up of the machine after a Long Term Storage Phase (flush out of preservative agents and air) 
Start up of the machine after a Chemical Cleaning Procedure (flush out of chemicals and air) 
Start up of the machine after a stop longer than 1day (flush out of growed microorganism and air) 
Start up of the machine after a relocation of the unit (flush out of rest-water and air) 
Start up of the machine after the pull up of the feed hose out of the well (de-airing of the unit is necessary) 


NOTICE 


To operate the system it's necessary to vent (de-airing) all installed devices. 

When the system don't will be ventilated before going into operation, that can cause 
serious damages on some important equipments like Feed Pump, Ultrafiltration Module or 
Activated Carbon Filter. 


The Ultrafiltration Module M1 is filled with the long term storage agent Propylenglycol. This 
chemical must be flushed out of the system before going into operation and using the 
produced water for drinking. 





[T1] 
[V1] 
[ Flow Path] 


Indicated on Hand Lever 





[V2] 


= The Battery is charged (loaded full) or the system is connected with 230 V. 
= The feed hose is positioned in the water well and the other hoses are installed. 
= Take and use the Process Flow Diagram (PFD) too for better understanding. 


Trunz Water Systems AG —_ www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 21 von 52 


TRUNZ 


User Manual Survivor 300 Ql water systems 


=" See the picture above: Adjust the valves (handlever) according to the shown positions. 
The flow direction of [V1] is <Filtration> and valve [V2] is open <Drain>. 

= Start the Survivor by switching <ON> the Main Switch [9] on the case front ... (see also chapter 5.1). 

= The pump P1 begins to run. A slightly knocking and priming is to hear (The hoses are empty and it's air 
in the piping). Don't be confused, the first running noises are normally. 

= The first well water will be sucked into the system. The first incoming water is to see in the transparent 
strainer housing F2. 

= When the feed hose (from strainer basket F1 to the case is filled, then the water flows into the 
Ultrafiltration Module M1. The Drain Valve [V2] is open and the first preservation fluid and rest-air will 
be eject to the drain outlet and sewage duct. 

= Observe the flow and air bubbles out of the drain hose. Let the system run so long till an equally 
constant flow without bubbles comes out of the drain hose. This should require approx. 2-3 minutes. 

= Now let the Survivor run with this valve settings for app. further 5 minutes to flush out Propylenglycol. 


9.2.2 Step 2 — Fill & Vent = Close the Drain Valve [V2] , but not too quickly. 
the complete Unit You don't need stop the pump during turning the 


y 


handlever of the valve. 

A Aa -- = Now this picture shows the operating mode 

TRUN “Vie Ee <Filtration> 

WATER svs | = The red caps of VU1 and VU2 [10] remain 

n 7 : Y% round open all over all stages of 

operating (every time of operating) 

= Water now passes the membranes. It flows through 
the membrane walls. 

=  Filtrated water exit the UF-Module M1 at the Filtrate 
outlet to the valve V1 (see fat red arrows) 

= Preservative fluid and air bubbles in the module 
and piping will be flushed out. 

= Now let the Survivor run with this valve settings for 
app. further 5 minutes to flush out Propylenglycol. 


rary Deus ee Pop abe res Cem 





NOTICE 


The Activated Carbon Filter Cartridge is not installed during the initial start up. 
The flushed Propylenglycol would destroy the carbon activity. 

The vacantly filter housing don't need ventilated. The air will be displaced by the 
filtrate completely through the filtrate hose. 





5.2.3 Step 3 — Flushing the Unit / Membrane Backflush Procedure 





Minimum 4 repeated Backflush to displace and eliminate preservative and air bubbles. 


Le A L 
WATER SYSTEMS | - i i 
SWISS MADE \ 


arara punin iieri yain oF 





Pic 1: Backflush — Phase 1 Pic 2: Backflush — Phase 2 





Trunz Water Systems AG www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 22 von 52 


TRUNZ 


User Manual Survivor 300 q Miter Seater 


A complete Membrane backflush procedure contains 2 phases. For a Membrane flush it will be used only 
Ultrafiltrate from Flush Tank T1. 


Never flush or try to clean the membrane by feeding a dirty, strange or unknown fluid into 


the module filtrate port. This is strictly forbidden. In this case the membrane will be 
destroyed. Only ultrafiltrated filtrate wnat was produced with this module in the Survivor is 
allowed to use. Such usable filtrate is available in the tank T1. 





Backflush Phase 1 — Filling of Tank T1 (see Pic.1 above) 


| ing, fi i V1 — Backflush M 
The pump is running, filtrate comes out of the filtrate hose. ackflush Mode 


Change the flow direction of the Filtrate to the tank T1. 

Do this by change the handlever position of the 3-way valve V1 as shown in the Pict. 
Look and have regard to the indicated "Flow-Path" on the handlever. 

Don't stop the pump for the procedure during the tank filling. 
The tank will be filled now. This can take app. a half minute. The pressure in tank T1 increases. Monitor 
the pressure arising at manometer PI2. 

= The pump P1 stops at app. 3 bar automatically. Now the tank is full and is under pressure. 





Backflush Phase 2 — Flush the Membrane (see Pic.2 above) \/2 — Discharae Mod 
V2 — Disci arge ode 





Open the Drain Valve V2 quickly 
The tank T1 discharges rapidly, the pressure in tank T1 drops down. 
The water flows during the flush from tank T1 backwards to the filtrate port of the module. 
Thereby flows the flush-water through the membrane in outside to inside direction. 
This process is lifting the fouling layers from the membrane-surface inside of the capillaries. 
When the pressure is dropped down under 2 bar, then the pump P1 begins to run automatically. 
The pressure drop from 3 to 2 bar takes about 1 - 2 seconds only. 
= Now the lifted dirties will be flushed away by a forward flush through valve V2 
to the drain outlet. 
= The tank T1 will be discharged completely. 
= The pump continuous to run and pumps well water through the 
module to the drain (forward flush). 
=" Stop the membrane flush by closing of drain valve V2. 


V2 — Stop Mode 





5.2.4 Step 4 — Start up Checks 


= Check the noise of running pump. If bumpy or disturbed run, then ventilate the system again. 
Check all hoses and connections: Is the feed hose with the strainer basket completely submerged? Is 
anywhere priming air through unsealed connections into the piping system? Has the battery enough 
energy? Check it at the solar controller C1. 

= |f using the solar panel, then check if all black cells are completely in the sun. Only 1 black cell in the 
shadow can reduce the charging capacity nearly completely. In this case only app. 2 percent of 
charging activity are active, the other cells are "dead" ... (98 % percent of solar area are inactive). 

= Check the inlet pressure at manometer PI1. Is a low inlet pressure available, then it's good. The well 
water is good and you have to anticipate a longer filtration period without trouble or flushings. 
Is the start pressure at Pl1 nearly 2 bar, then is a closer check or a backflush necessary. 


NOTICE 


In the nature it can be happen, that you meet unfiltrateble waters. Finest pollutions and particles are 
blocking the membrane immediately. Such particles have a particle size of nearly 0,02 um, what would 


clogging and blinding the membrane-pores in shortest time. 

In case of high start pressures or rapidly pressure arises within shorter than 10 minutes up to the next 
necessary backflush, the water is normally unusable to filtrate in <Dead-End> mode with the Survivor. 
How it's possible to run the system nevertheless will be described in the later chapter <Cross Flow>. 





Trunz Water Systems AG  www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 23 von 52 


TRUNZ 


User Manual Survivor 300 Ql water systems 


= Check the filtrated water for colour and turbidity. 
In case of strong coloured raw water it can be happen, that the filtrated water has a slightly colour too. 
Many colour substances in water can not eliminated with Ultrafiltration. 
In case of turbidity in the Filtrate it can be that you have a defect membrane. Normally, all particles 
bigger 0,02 u will be reject on the membrane surface. To be sure that the membrane is not defect you 
must make an <Integrity Test> with the module. This membrane-check will be described later in this 
manual. 
PS: In some cases it's helpful to insert the carbon cartridge. Carbon is able to adsorb many unknown 
substances. Do not drink the <First Filtrate>, that means the water what is coming from the carbon filter 
in the first 5 minutes. Carbon particles from a new cartridge must be flushed out in the first 5 minutes. 
= Check the taste and smell of the filtrated water. For bad tastes and smells is the carbon filter ideally to 
eliminate such substances and he is able to improve the water quality. Insert the carbon cartridge, 
ventilate the carbon filter during filling this unit and consider the first 5 minutes flushing of the carbon 
filter. 


5.2.5 Install / Replace of the Carbon Cartridge and Venting of the Carbon Filter 





Replace a carbon cartridge as shown in following pictures. Then start the Survivor and ventilate the carbon 
filter in the first 2 minutes when water is filling . Press the green button. During ventilation hold additionally a 
cloth over the green button against splashing. 


6. Ventilate Carbon Filter 
Press Green Button until 
Water spills bubble-free 


1. Remove the Housing 2. The blank Housing 3. Insert Cartridge 4. Attention to Gaskets 5. Assembling the Housing 
unscrew clockwise & Center Nozzle vertical centric of the Cartridge screw counterclockwise 


7 





DANGER 


Use, filtrate and drink only water from Known water wells or where you can be sure that the 
well water is not toxic or deadly contaminated. The Survivor is not able to reject such 
dangerous substances (heavy metals, pesticides, fertilizer 


NOTICE 


In cases of longer system stops or component changes (e.g. change of the carbon 
cartridge), repairs etc, don't use the filtrate (product water) for drinking. 
Rinse the system and discharge the "first filtrate" for some minutes (minimum 5 Min). 


6. Operating the Survivor 


The Survivor is a manually operating system. All operations are to initiate and monitor by the operator. 

In this chapter will be described the manually procedures and operating modes. It will be assumed that all 
preparation works are done and a start up procedure was successful. The Survivor is ready to run and the 
machine is connected to a power supply (solar or main), the battery is charged and all hoses are installed 
as described before. 


Trunz Water Systems AG  www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 24 von 52 


TRUNZ 


User Manual Survivor 300 Ql water systems 


Following main operating duties and responsibilities are to manage during the running of the plant: 
Switch ON /OFF the Survivor 

Monitor the water pressures and flows 

Observe and check the water qualities 

Monitor the Solar-, Charging- and Battery-Status 

Regard to the accurate and trouble-free running of the machine 

Initiate the Membrane flushes 

Accomplish additionally chemical cleanings if necessary 

Service, Cleaning , Maintenance 


Never operate the Survivor with closed cover. In case of hot ambient temperatures or when 
the Survivor stands directly in the sun then is danger for overheating. The controller C1 and 
charger C2 would damaged. 





6.1 Process Methods 


In principle it's possible to operate the Survivor with 2 filtration methods. 

Which process is better usable is strong dependent to the well water quality: amount of Suspended solids, 
amount of particles and their size or the grade of microbiological contamination. 

The Ultrafiltration is a pure "solid-fluid-separation"-process. All solids and particles bigger than 0,02 um are 
separable. A process changing or a switch over between the processes is very simple and is manageable 
during the filtration without switch-off of the Survivor. 


It will be distinguish between the <Dead-End> process and the <Cross-Flow> process. 






















































































































































































< Dead End > < Cross Flow > 
Filtrate V1 Filtrate V1 
= DE Backflush == Da Backflush 
Drain Drain 
>< D UF-Module <= Feed q = >< c UF-Module <= Feed 
V2 PIs V2 PIS 
closed slightly open 
Pic. 6.1 





A Turbidity 


An important parameter for decision which filtration method is to use or is better suitable is the Turbidity- 
parameter. The turbidity gives a good information and estimation how many undissolved solids and particles 
are in the water. The measuring unit of the turbidity is NTU (Nephelometric Turbidity Units). It will be 
measured with a photometer (turbidity-meter) by light transmittance. Experienced user also can evaluated 
visual approximately the turbidity. In chapter 6.3 "Monitoring of Water Quality" it will be given some more 
informations about turbidity and proposals for suitable filtration modes. 


6.1.1 Dead-End Filtration 


In picture 6.1 is shown the Dead-End filtration principle. This process is the normally filtration method 
recommended and preferred by Trunz. Dead End Filtration is possible with relative clean well water 

(< 5 NTU turbidity). 

PS: 5 NTU turbidity means that you can look in a lake up to app. 2 meter water depth to the lake ground. 


The feed-water flows into the module. The drain valve V2 is closed (dead end of the module). The filtrate 
valve V1 is adjusted to <Filtration> mode (see adjacent picture or chapter 5.2.1). All feed water passes the 
membrane-walls and flows to the filtrate outlet. The particles will be separated and rejected and form a 
fouling layer on the membrane surface. The fouling layer increases with the time of filtration and the module 
inlet pressure rises up. When the inlet pressure reaches app. 2 bar (this is to observe at manometer PI1) a 


Trunz Water Systems AG  www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 25 von 52 


TRUNZ 


User Manual Survivor 300 Ql water systems 





membrane backflush (see chapter 5.2.3) to clean and purge 
the membrane surface is necessary. Trunz proposes to flush 
the membrane when 2 bar inlet pressure are reached. With 
this pressure the membrane fouling is not too high and the EE panes. 
membrane cleaning brings a better effect and result. The x 

feed pump would stop at 3 bar inlet pressure self-acting. 
This 3 bar stop-pressure is pre-adjusted in the system. A 
filtration with more than 3 bar inlet pressure is not possible. 
The pump don't would run in case of higher pressures. A 
membrane backflush and the membrane cleaning would be 
much more difficulty and problematic in case that the 
machine stops due to an over-pressure. 





After a 3-fold backflush the membrane surface should be 
clean and the inlet pressure in <Filtration> mode should drop to a normal level of a little bit more than 0,2 
bar (the manometer shows 0 bar due to measuring tolerances). 

The frequency and quantity of necessary membrane backflushes is dependent to the feed water quality like 
mentioned in the chapter before. In case of a flush frequency need with more than all 1⁄4 hours it's to decide 
to change the process method to the <Cross Flow> or to have the research that this water is not filtratable. 
The last one is a fact in case that also the <Cross Flow> method don't would bring success or a filtrate 
output in sufficient flow rates. 


6.1.2 Cross-Flow Filtration 


The cross-flow filtration method is a simple and a widely-used filtration process. Compared to the Dead-End 
Filtration here will be opened the drain valve V2 a little bit to release the module pressure. Partially turbulent 
tangential flows along the membrane capillaries outwards to the drain outlet avoid a quickly blocking of the 
membranes because the rejected wastes in the module will be drained out permanently during the filtration 
process. The picture 6.1 shows the principle of the <Cross-Flow>. 


This method will be used in cases of: 

= Very dirty well water (turbidity > 5 NTU) 

= High frequency of needed membrane backflushes 

= Ventilation of the UF-Module 

= Long filtration periods if needed and wanted and the filtrate flow and filtrate amount is not primary 


Advantages of this method: 

Long filtration phases without backwashes 

The membranes don't will be stressed so much 

Lower filtration pressures. 

Very slowly increasing fouling layers on the membrane surface by a turbulent stream in the capillaries 
Not so strong and solid blocking particle layers 

Membranes are easier to clean and backflush 

Minimized and reduced service and maintenance of the membrane and whole unit 


Disadvantages of this method: 

= Reduced but acceptable filtrate flow 

= Much more produced drain water 

= It's needed some Ultrafiltration experiences to operate this process manually 
An operator's feeling for flows and pressures in the system is demanded 


Operating and adjustings at the Survivor: 


In pre-view the Survivor is running in the <Dead End> mode. 

Adjust manually flows and pressures by opening of valve V2 step by step as shown in the next pictures. 

V1 still stay in the <Filtration> position and V2 will be opened slowly more and more. Observe the pressures 
Pl1 and PI3 and the flow rate at filtrate- and drain outlet. 


Trunz Water Systems AG  www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 26 von 52 


TRUNZ 


User Manual Survivor 300 | sie Santen 








Pic 6.2A Pic 6.2B Pic 6.2C 


Test data with Swiss drinking water in the following table are showing valve adjustings and the resulting 
flows. Swiss drinking water is so clear so that no pressures were shown at the manometers PI1 and PIS. 
The polluted the well water the higher the operating pressures. 














































































































































































































Process V2 Valve Position Flow Filtrate Flow Drain 
Handle Opening in [l/h] [l/h] 
0° closed 
Dead End 190 0 
<— 
10° opened 
Cross Flow 178 12 
K m 
15° opened 
Cross Flow 120 70 
K m 
20° opened 
Cross Flow 70 120 
K m 
25° opened 
Cross Flow 35 155 
<— 
30° opened 
Cross Flow 20 170 
K m 


























In the table is to see that only a minimal opening of the drain valve during the filtration has a big influence to 
the flows of filtrate and drain. 

The drain water don't must be loosened water. It can be given back to the water well. In case of a river or 
lake as water well such a question where the drain water can be given is inconsiderable. 


6.2 Operating- & Monitoring Elements and System Control 


6.2.1 Operating Elements 


Switch the machine ON / OFF with the Toggle Switch. 
When switch <ON> the pump starts promptly. 
When switch <OFF> the pump stops promptly. 





Trunz Water Systems AG www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 27 von 52 


TRUNZ 


User Manual Survivor 300 Ql water systems 


Manually Valves: 

The picture shows V1 & V2 adjustings in the 
<Filtration> mode in a Dead-End process. 

The name "Dead-End" is selected because the drain 
valve V2 and drain outlet is closed. The water feeds 
in the module and all incoming water must through 
the membrane walls. The module has a dead end at 
the drain side. 





Consider the mentioned possible operating steps: 


Start up: Chapter 5.2 
Filtration: Chapter 6 
Backflush of Membranes: Chapter 5.2.3 


Stop the machine and maintenance: next Chapters in this manual 


6.2.2 Monitoring Elements 


Manometers (look into Flow-Diagram and see the positioning of the manometers): 


PI1: Shows the module inlet pressure. Up to app. 2,5 bar a normally Dead-End-Filtration is 
possible. Latest at this reached inlet pressure a 3-fold membrane backflush should be initiate. 
Trunz advises to initiate the backflush at app. 2 bar inlet pressure to preserve the membranes 
and guaranties a high filtrate flow over longer periods. 

PI2: Shows the backflush pressure. The survivor has a presetting of 3 bar for the backflush 
process. When valve V1 is adjusted to <Backflush>, V2 is closed and the pump is running then 
the tank T1 will be filled up to 3 bar. Then stops the pump. Then you open the drain valve V2 
quickly and the backflush process Is initiated. 

PI3: This manometer shows also the pressure within the module during the <Dead End> 
filtration. It also shows the drain pressure (counter pressure) in the <Cross Flow> mode. This 
manometer is also important in the chemical cleaning procedures. 





Flow Measurement: 


The flow (filtrate quantity) will be measured manually by the operator staff. The 
measurement unit is Liter per Hour (l/h). 


Hold a measuring glass with scale under the filtrate stream. Measure exactly 15 
seconds. Use a clock with a second hand. Read then the volume in the glass. 


Calculation example: 

You have filled 790 ml in 15 seconds. Convert the 790 ml to Liters 790 : 1000 = 0,79 
Liter. Multiply these 0,79 | with 4 0,79 * 4 = 3,16 I/min (Liter per Minute). 

Multiply the 3,16 l/min with 60. The result is: 190 I/h (Liter per Hour). 





i Note this result with date and time in your own self-made list to comprehend the 
measurements for the future. So you can reconstruct the capacity / effectivity of the 
ultrafiltration module, also after backflushes / cleanings or flow differences over longer 
periods. 


Flux: 

Flux is a designation to describe the water flow in the module per square-meter (m?). The measurement unit is liter 
per square-meter and hour (| / m?h ). With this unit it's possible to compare the effectivity and flows of your module 
with other modules, also modules with different filter-surface or modules of other manufacturers or totally other 
module-types. 

Calculate as follows: 

Your measurement result above was 190 I/h. Your module in the Survivor has a filter surface of 2,0 m?. 

Divide the 190 l/h with the 2 m? 190 / 2 = 95 |/m?h. 

Every square-meter in your module has filtrated 95 l/h. 


Trunz Water Systems AG  www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 28 von 52 


TRUNZ 


User Manual Survivor 300 Ql water systems 


Solar Charge Controller C1 


These instructions describe the functions of a charge controller for 
photovoltaic (PV) systems to be used for charging 12 V lead-acid 
batteries. The charge controller is only suitable for controlling solar 
modules. The controller is not suitable for use with nickel-cadmium, 
nickel-metal-hydride, lithium-ion or any other types of rechargeable 
or non-rechargeable batteries. 





Controller Protection Functions 


The controller is equipped with various systems for protecting its electronics, the battery and connected 
load. Triggering of the protection devices is indicated by an error message (Section Error messages). The 
protection devices automatically reset when the error has been corrected. 


Danger of damage to the controller. Despite the protective functions, the controller can still 
be damaged when more than one component is incorrectly connected. 





The protective functions of the controller cover the following points: 


= Protection against reverse connected solar modules. The rated power of the solar modules must not 
exceed the rated power of the controller! 

= Protection against reverse connected load devices on the load output. Protects the controller but not the 

load device. 

Protection against reverse connected battery charging and discharging of the battery are prevented. 

Short circuit fuse at module input 

Short circuit fuse at load output 

Protection against excessive charging current. The controller disconnects the battery and switches off 

the load. 

= No-load protection when operated without battery or load. Load output is protected from the module 
voltage. 

= Reverse current protection. Prevents reverse current from flowing into the solar modules at night. An 
additional reverse current diode is not required! 

= Overvoltage and undervoltage protection. Immediately switches off the load output in the case of 
excessively high or low battery voltage. 

= Overtemperature protection. If the temperature inside the controller becomes too high, then the 
controller load output is switched off to reduce the power loss. 

= Load output overload protection. If the permissible load current is exceeded, then the load output is 
switched off. 

= Overvoltage protection. A varistor at the module input provides protection against overvoltages > 47 V. 
The component limits the surge energy to 4.4 joules. 

= Deep discharge protection / Overcharging protection Prevents excessive discharging / charging of the 
battery. 

= Conforms to the relevant European CE standards 


Operation of Controller 


The display shows numerous types of system data using symbols and numbers. 
All settings and display windows are controlled via the two buttons. 


Trunz Water Systems AG  www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 29 von 52 


TRUNZ 


User Manual Survivor 300 Ql Water systems 
Ps = [1] Display window for system information and error 
ie = messages 
p = [2] Button for switching between the display windows or 
- = for accessing settings 
i = [3] Manual load switch or confirmation button when 
O = performing settings 





Trunz advises strictly to use only the left button [2] to display the operating status. 
Right button [8] is only to use by Trunz engineer for programming the system. 





The display windows contain different tyoes of system information. The left button can be used to switch 
between the different display windows. After the last window, the first window is displayed once more. 


Symbols for current direction 


Battery symbol 
Sun: Charge / Day Load symbol 
Moon: Night 
_ Face symbol for 
Tool symbol for 


system status 
emor messages 





SOC bar display -7 a 
SOC = state of charge 


Units display 


7-segment display for 
text and numerals 


By pressing the left button [2] (button with the cursor arrows) it's possible 
to scroll between the status windows as the next pictures show: 
1. SOC window 
Monitoring Start and Basic Display 
Displays the charge state, day / night status and load on/ off status. 
In the Voltage control operating mode, the battery voltage is displayed 
instead of the SOC value. 


In the Voltage control with bar display operating mode, the battery voltage 
is displayed both alophanumerically and as a bar display. 


Battery Voltage Display 
Displays the battery voltage measured by the controller. 


Displays the Solar Module Output Current 





Trunz Water Systems AG  www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 30 von 52 


TRUNZ 


User Manual Survivor 300 q ‘iter Svsterne 


4. Charging current 


Solar Energy into Battery 


Current Consumption 
Displays the current being consumed from the load output. 


2 — Ah (total) charged into Battery 


Displays the total Ah charged into the battery since initial installation or the 
last reset of the meter. Pressing and holding both buttons for 3 seconds 
resets the meter to 0. The value is retained when the battery is 
disconnected. 

After reaching a value of 99.9 kAh, the meter jumps back to 0 Ah. 


2 — Ah (total) Discharged by Load Output 


Displays the total Ah discharged via the load output since initial installation 
or the last reset of the meter. Pressing and holding both buttons for 3 
seconds resets the meter to 0. The value is retained when the battery 

is disconnected. 

After reaching a value of 99.9 kAh, the meter jumps back to 0 Ah. 





It's not possible to select the following displays by pressing the left button [2] 
These are protection displays and appears in case of warnings. 





Deep discharge protection advance warning 


The following symbols flash in the various operating modes to provide 
advance warning of deep discharge. 

e SOC bar (SOC with bar display) 

e Voltage value (Voltage control) 

e Voltage value and voltage bar display (Voltage control with bar display) 
The face symbol still looks happy. 


The following symbols flash when the deep discharge protection is active: 
e Bar display (not in Voltage control mode) 

e Battery symbol 

e Right arrow 

e Load symbol 

e Alphanumeric value 

The face symbol remains sad until the switch-on threshold is reached. 





The controller is configured and ready to operate. Changes of settings in the configuration 


by unqualified personal or unauthorized people may have operating trouble or can damage 
unit equipments. 
Trunz urgently advise against independent or unauthorized manipulations at the system. 





Trunz Water Systems AG  www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 31 von 52 


TRUNZ 


User Manual Survivor 300 Ql water systems 


Following items don't will be described in this manual, because not necessary to know for operating: 
Installation and connecting the controller 

SOC calculation 

Deep discharge protection be described in chapter 8. 

Night light function 


Daylight function 
Configuring the controller 


(@}U(@8S By multiplying of the Battery Voltage value [V] (display window 2) with the Consumed 


Load Output value [A] (display window 5) you will get the Power Consumption in Watt [W] 





Solar Charge Controller C1 


General Overview LED Indicator 





The charger is a fully automatic, electronic multi-stage on-board 
marine battery charger. It is pre-wired for easy installation and is 
100% waterproof for fresh and salt water applications. 

It's incorporate extruded aluminium housing with plastic end 
caps. This design offers improved durability and heat transfer 
while comparing it to full plastic case competitive products. The 
producer offers multi-stage charging which includes a “float” 
maintenance mode that is safe for long and short term storage. 
The manufacturer can be left on indefinitely without harming or 
overcharging your batteries. : 
The Distributed-On-Demand TM multi-stage charging technology will automatically sense ano distribute 
100% of the available charging amp output, i.e. 8, 12 or 20 amps (model specific) to any one bank or 
combination of all banks. Each battery bank output is fully isolated. 

Easy to view LED indicators will provide you with AC power on and charging status. The LED indicators can 
be seen from the front and the side of the charger when installed. 

The charger is available in different models and can be used in 12, 24 and 36 volt configurations (model 
specific) without rewiring or switching. With your Charger plugged in properly, it will automatically and fully 
charge your batteries while it conditions and extends the life of your batteries. 


General Safety Instructions 


= Before connecting your batteries or AC power, read all instructions and cautionary markings on the 
battery charger and batteries. 


CAUTION: To reduce the risk of injury, charge only lead-acid type rechargeable batteries (open lead-acid, 
sealed lead-acid, gel cell and AGM). Other types of batteries may burst, causing personal injury. 


= Use of attachments not recommended or sold by Sterling Power Products may result in a risk of fire, 
electrical shock or personal injury. 

"= Do not operate the charger if it has received a sharp blow, direct hit of force, has been dropped or 
otherwise damaged in any way. 

= Do not disassemble the charger. Call the factory directly when service or repair is required. Incorrect 
assembly may result in risk of electrical shock or fire. 

= To reduce the risk of electrical shock, remove AC power from the charger prior to any maintenance or 
cleaning. 


WARNING: RISK OF EXPLOSIVE GASES 


Working in the vicinity of a lead-acid battery is dangerous. Batteries generate explosive gases during normal 
battery operation. 


Trunz Water Systems AG  www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 32 von 52 


TRUNZ 


User Manual Survivor 300 Ql water systems 


Personal Safety Precautions 


To reduce the risk of battery explosion, follow these instructions and those published by the battery 
manufacturer, and of any equipment you intend to use in the vicinity of a battery. Review all cautionary 
markings and labels. 

Someone should be within the range of your voice or close enough to come to your aid when working near 
a lead-acid battery. 

Have plenty of water and soap nearby in case battery acid comes in contact with skin, clothes or eyes. 
Wear complete eye protection and clothing protection. Avoid touching eyes while working with a battery. 

If battery acid contacts skin or clothing, wash immediately with soap and water. If acid enters the eye(s), 
flood eye(s) with running cold water for at least 10 minutes and get medical attention immediately. 

Never smoke or allow a spark or a flame in the vicinity of a battery or engine. 

Be extra cautious to reduce the risk of dropping a metal tool onto a battery. It may spark or short-circuit the 
battery or other electrical parts that may cause explosion. 

Remove all personal metal items such as rings, bracelets, necklaces, watches, and jewellery when working 
near a battery. A battery can produce a short circuit high enough to weld a ring or any metal, causing 
serious burns. 

Use the unit for charging lead-acid batteries only. Do not use the battery charger to charge dry cell batteries 
that are commonly used with home appliances. These batteries may burst and cause injury to persons and 
property. Never charge a frozen battery. 


Safety Precautions Prior to Charging Batteries 


If necessary to remove a battery from a boat to charge, always remove the grounded terminal from battery 
first. Make sure all accessories in the boat are off, as to not cause an arc. 

Be sure the area around the charger and the batteries is well ventilated while the batteries are being 
charged. Gases can be forcefully blown away using a piece of cardboard or other non-metallic material as a 
fan. 

Clean battery terminals with full eye protection to prevent corrosion from coming in contact with eyes. 

Add distilled water in each cell until electrolyte reaches levels specified by the battery manufacturer. This 
helps purge excessive gases from cells. Do not overfill. For batteries without caps, carefully follow the 
manufacturer's recharging instructions. 

Study all manufacturers’ specific precautions, such as removing or not removing cell caps while charging, in 
addition to rates of charge. 

Extension cords should be industrial grade / heavy duty and grounded. Check extension cord before use for 
damage, bent prongs and cuts. Replace if damaged. 

Never charge a frozen battery. 

Always make your extension cord connection on the charger side first. After connecting the extension cord 
to the charger proceed to plug the extension cord to a nearby AC RCD-protected (ground fault circuit 
protected) outlet. 

Always remove the extension cord from the AC outlet first when charging is completed, followed by 
unplugging the charger. 


Charging Batteries 


The charger is designed to charge, condition and maintain your batteries. Follow 

these steps each time you use your charger. 

1. Open all battery compartments and ventilate for at least 15 minutes before applying AC power to your 
charger. While charging your batteries make sure to keep your battery compartment open, allowing for free 
air ventilation. 

2. Make sure all DC battery connections are tight and clean. Follow the battery manufacturer's 
recommendation for battery cell caps. Loosen caps if applicable. 

3. Connect a heavy duty extension cord to the Survivor and correct connection port. 

4. Observe the on-board LED indicators for a solid green and red indication. This will tell you the batteries 
are in the charging process. 

5. Charge your batteries until only the green LED indicator remains on. This indicates that the charging 
process Is completed and your batteries are fully charged and are now being maintained in a gentle float / 
storage mode. The unit can be left on in this mode indefinitely and will never overcharge your batteries. 


Trunz Water Systems AG  www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 33 von 52 


TRUNZ 


User Manual Survivor 300 | ‘iter Svsterne 


AC Power and Charging LED Status Indicators 





Blue “AC Power” LED indicator 
Green charge complete and charger on float. 
Red “Charging” LED indicator, high charge rate on 


Maintenance and trouble shooting for the charger are included in chapters 7 and 8. 
6.2.3 System Control 


The Survivor has no automated system control. 

When the Main Power Switch is ON or OFF then the system is running or not. 

The only electronics are the monitoring display of the solar charger or the indicating LED at the battery 
charger. 


6.3 Monitoring of the Water Quality 


The Survivor has no automatic inline water quality monitoring (quality sensors) integrated. 

To be sure that the unit produces acceptable water quality, what is also in the line with the regional water 
quality standards for drinking water, then are periodically laboratory analyses necessary. 

With such quality analyses also can be evaluated if the UF-membrane is in order. 


The Survivor is a water treatment plant to produce drinking water. Drinking water has strict 
norms in line with food guidelines. The produced drinking water must be suitable for human 
consumption. 


The produced water is to be checked and analysed periodically before it can be used for 
drinking to prevent health hazards. 

The well water (Source water) is the feed water to the unit. This water is to be checked 
generally in short cycles. The well water is the basic for the possible quality of produced 
water. 

The Filtrate (drinking water) is also to be checked periodically in short cycles. This is 
basically advised to prevent health hazards. 

The owner, licensee, operator or user has the full liability or responsibility for the water 
quality which he produces with the unit and therefore for the health of the people who drink 
the water. 





Visual Checks: 
Daily and very uncomplicated it's possible to check the water visual. 


Well water: When the well water changes turbidity, colours, smells or flavour rapidly and significant in 
short time then it's to check the cause or reason. 
In hard cases it can be that the water is contaminated by industrial or agricultural effluents. 
Also environmental influences or natural catastrophes can be a reason. Then it's to check if 
this water is generally and basically usable to produce drinking water. 


Trunz Water Systems AG  www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 34 von 52 


TRUNZ 


User Manual Survivor 300 Ql water systems 


Filtrate: Check the filtrate (drinking water) permanent visually. Ascertain reasons when colours, 
smells and flavours change. The turbidity of the filtrate (drinking water) should be 0,00 NTU. 


Simple Measuring Checks: 


Well water or Filtrate can be checked with simple handheld measuring units. Temperature, pH-value, 
conductivity or per example turbidity are such parameter which are easy to monitor. For further references 
or verification it's useful to protocol the measuring values in a self-made list. 


Laboratory Checks: 


Laboratory checks of well water are only necessary in cases of strong suspicion of a water contamination. 
It's a way for the self-validation against external inspections and public authorities. 

According to regional instructions it may be necessary to take drinking water samples (filtrate) to analyze 
the water quality. For sampling must be considered special methods. Samples should be analyzed for 
chemical and microbiological contaminations. 


Turbidity:* 


* orientation values. The next mentioned examples are approx. values. The turbidity gives no information 
about the amount or size of particles in the water. It also don't gives information about a blocking risk of the 
membranes. It can be quite possible that particles are so little that they are invisible for human eyes, but 
they are able to block an ultrafiltration membrane. Mostly they are only difficult to identify as a micro light 
mist. The water seems to be clean but the mist is available. 


Turbidity Unit | look to the ground of a lake | Approx. frequency of 
[transmittance] necessary backflushes 
E 


rs a 
5 NTU only up to 1⁄2 m depth all 1⁄2 hour (half-hourly) 


The frequency of necessary backflushes increases with rising turbidity of the well water. 





Proposal: a) Use <Dead End> Filtration up to 5 NTU 
b) Use <Cross-Flow> Filtration when well water has more than 5 NTU turbidity 


It's the user's decision if he want or can backflush every 1⁄2 hour or every 3 hours or at longer periods. It's to 
concern that shorter backflush periods require more man-power and activity of the operator. 

With <Dead-Enas> filtration mode will be produced more drinking water in the same time compared with the 
<Cross-Flow> mode. With the <Cross-Flow> mode it's possible to filtrate much more longer time between 
the backflush cycles. 


Stop the drinking water production when visual-, measuring checks or analyses state a bad 


water quality. If necessary or where applicable consult regional experts or the Trunz Service 
Office. 





7. Service, Cleaning, Maintenance 


It's necessary to maintain the system periodically. 


Trunz Water Systems AG  www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 35 von 52 


TRUNZ 


User Manual Survivor 300 Ql water systems 


The system is basically low-maintenance. To ensure a problem-free operation, however, the following 
maintenance instructions are to be followed. 


Pressure release before works, service or maintenance at the Survivor. 


Attention to electrical hazards and to falling covers or unit parts. 
It's to consider the complete installed equipment, inclusive photovoltaic equipments. 





7.1 Maintenance Matrix 


Daily 

= Operating of the unit 

= Leakages or electrical errors 

= Visual check of the water quality 


Weekly 

= Check pressure of the membrane filter; (max. 3,0 bar during backflush) 
= Check prefilter F1 & F2; manually wash with brushes inside and outside 
= Check system for pressure losses 

= Outside cleaning of the Survivor case 

= Check water quality, especially the Filtrate for smell, flavour, turbidity ... 


Check control lamps if necessary 


Monthly 

Carry out weekly check as described above 

Cleaning of prefilter and membrane filter module 

Replacement of the activated carbon filter if necessary 

Carry out manual backwash of the membrane filter (possibly with cleaning liquid) 

Check pressure gauges 

Check flow rate of the product water 

Check the functionality of the switches 

Check pressure of the backwash tank T1 of the membrane filter (1,0 bar) 

Carry out analysis of the product water (viruses, bacteria etc.) 

Clean all battery terminals with a wire brush where required and tighten all battery connections. 
monitor and maintain battery's proper levels of distilled water 

Visually inspect all wiring for cuts and abrasions. 

Contact Trunz if charger needs to be serviced with new wiring. 

= Visually inspect the AC power cord. and if plug blades are in good condition and not bent out of place. 
= Check all mounting hardware to ensure there is no loose hardware. Tighten where required. 


Quarter 
= Carbon Cartridge Change if in use or necessary 
= Check corrosion, hoses, cables (if useful) or other defects 


Yearly 
= Main and generally unit inspection (complete mechanical, hydraulically) 
Check electrical equipment, especially cabling, incl. solar devices 


=» Replace damaged units 
= Order new spare parts for the next season (year) 


7.2 Replacement of the Carbon Filter Cartridge 


=> see chapter 5.2.5 


Trunz Water Systems AG  www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 36 von 52 


TRUNZ 


User Manual Survivor 300 q irede 


7.3 Prefilter Service 


In cases of very dirty Well Water, like contaminated with mud or algae, it's necessary to clean the Strainer 
Basket F1 and the Strainer F2 very often. 

Switch <OFF> the Survivor and pull off the complete feed hose out of the well. 

If necessary or usable then also disconnect the hose from the Survivor at the case inlet (CEJN-Coupling). 


Strainer Basket F1 


The original strainer Basket F1 is made from plastic and is 
a very rough prefilter with 0,6-2,2 cm meshes. In cases 
that the afterward located Strainer F2 will be very quickly 
blocked by pollutions, then the Gasket is too rough. Algae 
are also often a problem. Fix a plastic net with a mesh size 
< 5 mm around the gasket. Fasten it with a plastic cable 
strap such like used for electr. cables (see adjacent 
picture). 

Remove algae and other pollutions manually. Maybe a 
hand-brush is helpful to remove the dirties. 








4. Scrub the Housing 5. Scrub the Screen 
with a Brush with a Brush 
inside and outside inside and outside 


1. Remove the Housing 2. Unscrewed Housing with 3. Take out the 
unscrew clockwise Strainer Screen Strainer Screen 


7.4 Chemical Cleaning & Anti-Scaling of the Ultrafiltration 


Monitor and observe the filtrate flow rates of the ultrafiltration device. Measure and notice the flow rates of 
filtrate before a chemical cleaning (see chapter 6.2.2 Flow Measurements). 

In long Survivor running times, dirty water of indefinable and changing raw water qualities, may generate 
fouling layers on the membrane capillary surface. Also the periodically backflushes aren't be able to avoid 
this fouling effect. 

The creating of fouling is strong dependent to the raw water quality and the prefiltration. 


Fouling layers can be: 

= Deposits of organic or inorganic natural wastes (Chem. Cleaning) 

= Deposits of Microorganism (Chemical Cleaning and Disinfection) 

= Deposits of lime (Carbonate Compounds) e.g. by hard water (Anti-Scaling) 


In cases of decreasing flow rates of the UF filtrate, and this also after periodically backflushes, a chemical 
cleaning of the UF-membranes is necessary and essential. 

<Chemical Cleaning> means: Cleaning and flushing a system with chemical solutions. Only especially 
chemicals are allowed for ultrafiltration membranes. Some chemicals can damage / destroy the membrane- 
material. Cleaning solutions will be prepared by mixing of a concentrated chemical with water. The allowed 
pH-range in such cleaning solutions is pH1 and max. pH13 (e.g. for the Survivor membrane). 
Concentrations of cleaning solutions are simply of lower nature and are between 0,2 — 2 % Vol% 


Trunz Water Systems AG  www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 37 von 52 


TRUNZ 


User Manual Survivor 300 Ql water systems 


concentrated (diluted). Pure concentrated chemicals or solutions with pH1 or 14 are extremely caustic and 
very dangerous. Only experienced personal in handling with chemicals should work with such substances. 


Usable cleaning solutions may be: 

= Acids (organic acids, like Citric Acid or Acetic Acid, or inorganic acids like Sulphuric Acid) 
The pH-value of the ready usable cleaning solution can go down up to 1 

= Bases (Sodium Hydroxide NaOH or other alkaline membrane cleaner) 
The pH-value can be maximum 13. 

= Neutral Cleaner (special membrane cleaner, mostly tenside- or enzyme compounds) 
The pH range is between 6 — 8 


Strictly forbidden substances (for filtration or cleaning) are: 

"= All reagents and agents with chlorine or bromine components higher than 200 mg/l Cl concentrated 
= Hydrocarbon compounds (benzene, phenols ...) 

= Dissolver (Xylol, Toluene ...) > such substances disintegrate and terminate the membrane material 
» Laundry detergents, such what are used in domestic washing machines or strong foamy agents 


Information: Chlorine products have not so good cleaning performance. They are ideal for disinfection. 


Cleaning chemicals and disinfection agents are very corrosive and dangerous to health. 
The handling with them is only allowed to authorized persons. 


The cleaning procedure will be done only by especially instructed experts. 
This service personal has the necessary training and experiences and the suitable 
applicable cleaning equipment. 


NOTICE 


In case of service, cleaning or maintenance questions contact the local service station what 
is authorized by Trunz. 





Against all known fouling compounds on the membranes Trunz proposes and advises to clean the 
membrane or other plant equipments with the supplied Agent "MC1". 

This agent is a citric acid granulate what is able to eliminate organics and lime (cleaning & anti-scaling 
usable). Citric acid is a relative harmless C6-organic carbon acid. 

In the supplied service kit are included 5 packs a 150 g citric acid. 

1 pack is sufficient to prepare a 1%age Citric Acid solution for 1 effective membrane cleaning procedure. 
The 5 supplied packs are the amount for 5 complete cleaning procedures. 

Citric Acid granulate is per example a very good agent to eliminate lime in coffee-machines or water kettle. 
It's available or obtainable worldwide in Super-Markets, drugstores, chemist's trading companies and so on. 


Trunz Water Systems AG  www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 38 von 52 


User Man 


Chemical cleaning / Anti-Scalin 


ual Survivor 300 


rocedure 








Remove the Carbon Cartridge 
while Chemical Cleaning 


< Cross Flow > 













































VU2 


2 PI2 















































































































































Drain 
Filtrate 


Step1: Filling Tank T1 


Pic. 7.2.1 Backflush during Chemical Cleaning 














10 It. Bucket with a 
1 %age Citric Acid 
Cleaning Solution 














V1 VU1 PI 
Filtrate 
i PA 
F3 PIS Feed 
® 
D ll UF-Module | 
V2 F2 5 
slightly open S 
Drain i 
Filtrate 
10 It. Bucket with a 
1 %age Citric Acid 
i a Cleaning Solution 
Pic. 7.1 Chemical Cleaning Procedure j 
ele 
ae Ch) 3 bar 
Filtrate V1 VU1 PI 
i AN 
F3 PIS Feed 
E | UF-Module | 
V2 F2 5 
closed D 
LL 











F3 


























vuz] ÉP 




































































Filtrate VU1 PI1 
Feed 
as 

<< UF-Module 

V2 F2 y 
fully open 

gi Drain h 

Filtrate 
1. Ty | 


Step2: Backflush 


Pic. 7.2.2 Backflush during Chemical Cleaning 


10 It. Bucket with a 
1 %age Citric Acid 
Cleaning Solution 














Pre-considerations and calculation to prepare the cleaning solution 


The Survivor has a <Dead-Volume> of 5 Liter, that means the water volume inside of the module, the other 
equipments and the pipes. To be able to circulate the cleaning solution through the survivor (see Pic. 7.1 

above) it's needed additionally a 10 Liter bucket as circulating bin. The 10 liter bucket is also able to include 
the fully immersed Strainer Basket F1. In sum there are 15 Liter water for the cleaning procedure available. 


Now it should be prepared a 1 %age Citric Acid Solution for the 15 Liter circulating water. 
The Citric Acid granulate is a pure concentrate with a concentration of 100 % Citric Acid. 


Trunz Water Systems AG www.trunzwatersystems.com 


Version 1.0 — 07/2012 


i 


Water Systems 
Swiss Made F 


Seite 39 von 52 


TRUNZ 


User Manual Survivor 300 < ‘iter a 


Calculation: 


Calculation for solution mixing (Formula): 

Given is the 100% Citric Acid Concentration & 15 | Cleaning Solution. 
The ready cleaning solution should have 1 %. 

Searched: Volume (Mass) of needed Citric Acid 


End-Solution 


Ci* V1 C1 = Concentration of Chemical 
V1 = Volume of Chemical 
100% * x kg C2 = Concentration of End-Solution 


V2 = Volume of End-Solution 


V1 


V1 1 Liter Water = 1 kg 0.15 kg = 150g 


Result: To prepare 15 Liter cleaning solution with a concentration of 1% 
you must dose 150 g granulate into 15 Liter water. 





The above shown calculation can be used also for each other chemicals. The formula is every the same. 
Write in the equation on left side the data of the chemical you want use and on the right side the data of the 
wanted ready solution. In principle this calculation is not chemistry specialized, it's a normal mathematic 
equation. 


Preparation of the Survivor and Cleaning Solution for cleaning procedure 


Compare this description with the Pic. 7.1 above. The Survivor is filled with water from the latest filtration 
process and is in <OFF> mode. 

Stand a 10-Liter bucket adjacent to the survivor so that all hoses end in the bucket. For the cleaning 
procedure it will be prepared a circulation cycle. The cleaning will be done in the <Cross-Flow> mode (see 
also chapter 6.1.2). 


Fill the bucket with 10 liter clean water. The best is it to use ultrafiltrated water what was collected before. 
Only clean water is able to clean a plant. 

Hang the ends of all hoses (feed hose, drain hose and filtrate hose) into the bucket as above shown. Clamp 
them fix so that they can't slip out of the bucket during filtration. 


Give 1 pack MC1 (Citric Acid 150 g) into the bucket. Stir the water till the granulate is dissolved. 
Look that you have enough energy in the battery to run the Survivor for app. 1 hour. The best is, you have 
installed the solar-panel or have the Survivor connected with external 230 V. 


The 1 % citric acid solution is not eminently dangerous, but have regard that you don't get 
the fluid in the eyes. Reasonably use a safety glass. Should it be that you get anyhow acid 
in the eyes, flush them prompt enough with fresh water. Also wash the solution with fresh 
water from the hands or skin when you have touched the fluid. 





Remove the Carbon Cartridge from Carbon Filter F3 in case that it's installed. The acid solution would 
destroy the cartridge. 


Trunz Water Systems AG  www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 40 von 52 


TRUNZ 


User Manual Survivor 300 Ql water systems 


Cleaning Procedure 


Start the Survivor like an Initial Start Up (see chapter 5.2) 

The 3-way ball valve V1 is in position of <Filtration> mode 

Open the drain valve V2 a little bit to initiate the <Cross-Flow> mode. 

Adjust valve V2 to app. 20° opening of handlever to split the flows of filtrate and drain to app. 50/50 % 
(see also the table in chapter 6.1.2). The maximum drain pressure don't should exceed 0,5 bar (see 
manometer PI3). 

Note: Best cleaning effects will be reached with high flows and low pressures (at feed and drain side). 
Circulate the solution for app. 1 hour or longer through the complete treatment plant. 

In the time of the cleaning circulation the membrane will get cleaner and cleaner. The backpressure in 
the system will drop down. Adjust occasionally the pressures and flows at valve V2 manually and 
monitor the process. 

To accelerate or push the cleaning and enhance the cleaning effectivity we propose to initiate some 
backflushes while cleaning procedure. The first 3-fold-backflush should be app. 1⁄4 hour after starting the 
cleaning process. All further backflushes (1-fold) should be in intervals of app 10 minutes. 

When the cleaning solution is dirty then don't initiate a backflush. Loosened particles would block the 
membrane again due to the high backflush pressure what is needed. 

Open the drain valve V2 fully for the last 5 minutes of the cleaning procedure. The pressures will be 
minimized and the last foulings will be loosened by the high and turbulent flow. 

In case that the cleaning solution is very dirty you must exchange / recondition the cleaning solution in 
the bucket. For this stop the Survivor, empty the bucket to the sewage pit and fill the bucket with fresh 
water and citric acid again. The operator must have the feeling and knowledge at what time or at what 
degree of pollution the cleaning solution is not longer usable or effective. 


End the Chemical Cleaning and evaluate the Cleaning Effect 


After the cleaning cycle drain the dirty and acidity solution. Citric acid is not dangerous in this 
concentration and is biodegradable. 
Stop the Survivor (main switch <OFF>). Empty the bucket to the sewage. Lay the drain hose and the 
filtrate hose to the sewage. Put the feed hose with the strainer basket into the water well. Start then the 
Survivor (main switch <ON>). Flush the Survivor in <Cross-Flow> mode. Consider the ventilation 
methods during the start-phase. The drain valve V2 is app. 20° open. Acidity solution will be drained 
now to the sewage. 
Initiate also some backflushes to eliminate the acidity in the backflush tank T1 too. 
Flush, backflush and sewage now as long as the pH value in the drain and in the filtrate hose is at the 
feed water level (neutral, or close to pH 7). 
Note: When your feed water has per example a pH value of app. 7,8 then flush the system as long as 
the drain and also the filtrate have a pH of 7,8 too. 
Insert then the carbon cartridge again if necessary (see chapter 7.2). 
You have noted the initial filtrate flows at initial start up what was done with a new membrane. Consider 
this flow with the flow you have measured yet after the chemical cleaning procedure (flow measuring 
see chapter 6.2.2). The flow after the cleaning should have app. 70 — 95 % of the initial flow rate. You 
must try to reach these 70-95% after every further chemical cleaning. 
Note: An used membrane never will reach the flux-rates of anew membrane, never, regardless of the 
number of cleaning procedures. In the course of time (over months / years) the flow drops down, also 
after cleanings, up to a point at which the life time of the module is ended. This point is reached when 
the flow rate don't will exceed 25-30 % flow compared with the initial flow rate. 
Tipp: In case when it's not possible to reach approximately or nearly the initial-flows or latest measured 
flows then try following: 
> Increase the concentration of the citric acid cleaning solution (per example 2 %age) and make a 
chemical cleaning again (regard the preparation instructions and formula above) 
> Increase the cleaning time if possible ( 2 hours and longer) 
> Circulate the cleaning solution in <cross-flow-mode> for about 1⁄4 hour as above described. 
Then stop the survivor by main switch and let stand the unit over night (some hours). Then (at 
next day) re-start the Survivor and circulate for app. 2 hour. May be that undefined fouling 
layers need more time for loosening from the membrane surface or for the chemical reaction 
with citric acid 
> usean other cleaning agent, may be a 0,2 %age Sodium Hydroxide solution (NaOH) or a 
special membrane cleaner. Have regard to the instructions for use of this chemicals. 


Trunz Water Systems AG  www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 41 von 52 


q Water Systems 
Swiss Made F 





User Manual Survivor 300 


Never feed dirty or non-ultrafiltrated water backwards through the module, that means don't 
feed it into the filtrate outlet !!! This would destroy the module irreparable. 





Example for the preparation of a Sodium Hydroxide Solution (NaOH 





Sodium Hydroxide is a very effective cleaning agent, especially for fatty and oily pollutions. Also will be 
eliminated organics or colours or biological substances from food industry. NaOH has properties and effects 
in cleaning like soap or washing agent. 

Mostly pollutions and membrane layers on membranes can be eliminated with this agent. 


NaOH (also named "Caustic Soda") can be obtained in several concentrations from chemistry trading 
companies. Trunz recommends to use a 30 %age NaOH chemistry. It will be delivered in 25 It -canisters or 
smaller bins in fluid form. 


A NaOH-solution for the Survivor don't may exceed a higher concentration than 0,2 %. Such a 0,2 %aged 
solution has a maximum allowed pH value for the membrane of 13. 

The preparing and mixing procedure is the same like with citric acid. Also the cleaning procedure is the 
same like with Citric Acid. 


Calculation for solution mixing (Formula): 

Given is the 30% NaOH Concentration & 15 | Cleaning Solution. 
The ready cleaning solution should have 0,2 %. 

Searched: Volume (Mass) of needed NaOH 


End-Solution 


C1* V1 C2* V2 C1 = Concentration of Chemical 
V1 = Volume of Chemical 
30% * x Lt 0,2% * 151 C2 = Concentration of End-Solution 


V2 = Volume of End-Solution 


0,2 * 15 
V1 30 


V1 1 Liter Water = 1 kg 0.1 Lt= 100 ml 


Result: To prepare 15 Liter cleaning solution with a NaOH concentration of 0,2% 
you must dose and mix 100 ml NaOH (30%) into 15 Liter water. 





DANGER 


NaOH non-diluted in concentrations higher than 1% are very dangerous. It's very caustic / 


corrosive and has a eminent health hazard when coming in direct contact. The pH value as 
1%age solution is at 14, the highest alkali level what is possible. Only experienced or 
authorized people should operate with this chemical. Protective equipment is urgently 
necessary. 





Trunz Water Systems AG  www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 42 von 52 


TRUNZ 


User Manual Survivor 300 q iter Satan 


The 30 % NaOH agent is eminently dangerous. Have regard that you don't get the fluid in 


the eyes or on skin. Reasonably use a safety glass. Should it be that you get anyhow 
NaOH in the eyes, flush them prompt enough with fresh water. Also wash the solution with 
fresh water from the hands or skin when you have touched the fluid. 

The same directive is to consider with the 0,2 % solution. 





7.5 Integrity Test 


Turbidity in the filtrate, bad flavour or smell can have the reason that the Ultrafiltration membrane has a 
defect. In such a case it's useful to check the membrane with a simple <Integrity Test>. Air with 1 bar will be 
pressed in one side of the module, into the Feed side or into the Filtrate side. Both methods will be 
described here in this manual. Which method will be used is a deciding of the user and his compressed air 
equipment incl. adapters to connect the air supply. 

Air can not pass the membrane. Air molecules are much bigger as water molecules. The membrane has a 
porosity of 0,02 um so that air don't goes through the membrane-pores. 

When air passes the membrane during the test rapider than allowed, then the membrane is defect and must 
be replaced. An ultrafiltration-membrane is not reparable in case that the resin-sealing has a break or a 
membrane / capillary is broken. 


F3 sa Red 
£ P Hose Loop 


i above module 
(\’ pio 



























Hose Loop 
above module 






Remove the 
Carbon Filter 







Close Red 
Cap 


Air Hose 





Adapter 





PI‘ 







Filtrate Pipe 





















































k PI3 Air IN 
| cd) 
el <l UF-Module E 8 
ss a | 
open D 
Drain Hose H 
10 It. Bucket 
Pic. 7.5.1 Integrity Test (Filtrate Side) with 5 Lt. Water 





Principle (see Pic. 7.5.1): 


Injection of air with 1 bar pressure into the filtrate side of the module. The incoming air displaces the water 
from the module filtrate side through the membrane-walls to the bucket. 

Observe an air-passing through the membrane. Air can not pass the membrane walls because the 
molecules are much bigger than water molecules. 

The ends of drain- and feed hose are positioned in a water filled bucket to see air-bubbles better. The 
pressure drop at Pla don't should exceed 10 mbar per minute. 


Trunz Water Systems AG  www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 43 von 52 


TRUNZ 


User Manual Survivor 300 Ql water systems 


Test Instruction (Filtrate Side): 


The system is in Stop Mode and filled with water. 

Connect the air hose (with valve & manometer) as shown to the filtrate piping 

Position the drain hose and the feed hose as shown with a hose loop above the system 
Remove the Carbon Filter. 

Close all Red Caps of the ventilation units 

Adjust the valves V1 & V2 to Cross Flow Filtration Mode 


= Open the Air Valve V, till air manometer Pl, shows 1,0 bar 
= Close then the Air Valve Va 


= Measure the Pressure Drop 
- Pressure Drop at manometer Pla max. 10 mbar per minute (the membrane is ok) 
- Pressure Drop much more or there are bubbles in the drain- or feed hose / bucket or the pressure is 
not adjustable to 1 bar (membrane is defect) 


= Ventilation Purge 
- Disconnect the air hose and reactivate the ventilation units and valves. 
- Reinstall all feed and drain hoses in original status. 
- Start the system with water in Filtration Mode (contained air in the system will be purged). 


Hose Loop 
above module 





















Close Red 


F3 Cap 




























Remove the 
Carbon Filter 



























Close Red F2 
Cap O 
£ 
Filtrate Pipe P11 P I 
10 It. Bucket 1% Remove the F 
LL 


complete Feed Hose 


with 5 Lt Water ' 




















UF-Module 























F1 











V2 


closed 


Air Hose 


Compressed-Air 








Pic. 7.5.2 Integrity Test (Feed Side) Va 


Principle (see Pic. 7.5.2): 


Injection of air with 1 bar pressure into the feed side of the module. The incoming air displaces the water 
from the module feed side through the membrane-walls to the bucket. 

Observe an air-passing through the membrane. Air can not pass the membrane walls because the 
molecules are much bigger than water molecules. 

The end of filtrate hose is positioned in a water filled bucket to see air-bubbles better. The pressure drop at 
Pla don't should exceed 10 mbar per minute. 


Test Instruction (Feed Side): 


The system is in Stop Mode and filled with water. 

Remove the complete original feed hose. 

Connect the air hose (with valve & manometer) as shown to the feed connecting port 
Remove the Carbon Filter. 

Position the filtrate hose as shown with a hose loop above the system and end in the bucket 


Trunz Water Systems AG —_ www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 44 von 52 


TRUNZ 


User Manual Survivor 300 Ql water systems 


= Close all Red Caps of the ventilation units 
= Adjust the valves V1 to Filtration Mode 
= Close drain valve V2 


= Open the Air Valve V, till air manometer Pl, shows 1,0 bar 
= Close then the Air Valve Va 


= Measure the Pressure Drop 
- Pressure Drop at manometer Pla max. 10 mbar per minute (the membrane Is ok) 
- Pressure Drop much more or there are bubbles in the filtrate hose / bucket or the pressure is not 
adjustable to 1 bar (membrane is defect) 


= Ventilation Purge 
- Disconnect the air hose and reactivate the ventilation units and valves. 


- Reinstall all feed and drain hoses in original status. 
- Start the system with water in Filtration Mode (contained air in the system will be purged). 


7.6 Auxiliary- and Consumables 


Auxiliary Material 

For the survivor no additionally auxiliary material will be supplied. All auxiliaries which are necessary for the 
operating are content in the delivery. 

Electrical power (230V) will be supplied by the user / customer. 

The equipment for the integrity test is self-made by the customer / user. This should include an air hose with 
connecting adapter to the Survivor, a manometer, an air valve and compressed air. 

Consumables 

Consumable material is mentioned in the Spare Parts List / Service Kit (See appendix of this manual). 

= Activated Carbon Cartridges CTO-10, 20u 1 pcs per month 

= Membrane / Plant Cleaning Agent (Citric Acid) 1 bag a 150 g per quarter 


Propylenglycol for Long Term Storage or other cleaning & disinfection agents will be proposed by the local 
Trunz service agency. 


7.7 Spare- and Wear Parts 


Spare- and wear parts are mentioned in the attached spare part list. 


8. Defect Location, Troubleshooting 


Risk of injury by improper or faulty troubleshooting! 
Improper troubleshooting can cause severe injuries and property damage. 
> Troubleshooting only by especially trained and authorised professionals. 





8.1 List of Alarms & Malfunctions 


The survivor is a manually operating water treatment device. 
The only automated function is the charging and controlling of the battery status. 
The pump P1 has a calibrated <OFF> function and stops at an overpressure of 3 bar. 


Trunz Water Systems AG  www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 45 von 52 


< Water Systems 
Swis Made F 


User Manual Survivor 300 
8.1.1 Solar Charge Controller (C1) Protection Functions 


The protection functions of the controller are described in the 
chapter 6.2.2 — Monitoring Elements on page 29. 


8.1.2 Solar Controller (C1) Error Messages 


Never open the device to find faults and do not attempt to replace components yourself. 
Incorrectly performed repairs can result in danger for the user and the system. This will also 
invalidate all warranty claims. 





When the device detects faults or impermissible operating states, this is indicated by a flashing error code 
on the display. Errors are basically either temporary faults, e.g. temporary overloading of the device, or 
serious system errors that require external intervention. 

Since multiple errors cannot be displayed at the same time, the error with the highest error number (priority) 
is always displayed first. If multiple errors exist, then the next error code is not displayed until the higher- 
priority error has been fixed. 


The error codes have the following meanings: 


Disconnect the load, solar modules and battery. 
Re-install the device. If the error recurs, then 
please contact your specialist dealer. 


Communication error with the 
internal storage (EEPROM). 


Check the plug connection at the 6-pin edge 
connector, check the power supply and check for 
correct functioning of external expansions. 

If the error recurs, then please contact your 
specialist dealer. 


Communication error on the 
external Controller bus 
(6-pin edge connector). 


Short circuit in external Check the contacts of the 2-pin edge connector 


temperature sensor. 


Overtemperature. The 
controller has switched off the 
load due to internal 
overheating. 


Battery voltage too low. 
Voltage < 10.5 Vor < 21.0 V. 


Battery voltage too high. 
Voltage > 15.5 V or > 31.0 V. 


Excessive load current. The 
permissible load current of the 
controller was exceeded, causing 
the load output to be 

switched off. 


Trunz Water Systems AG www.trunzwatersystems.com 


and remove the short circuit. Check sensor. 


Allow the controller to cool down. Check for 
possible causes of overheating (mounting location, 
other heat sources). Possibly reduce the charging 
current or load current. Make sure the controller 

is adequately ventilated. 


Check installation. Check the battery voltage and 
manually recharge the battery if necessary. 
Loads directly connected to the battery can cause 
deep discharge! 


Check installation. Check the battery voltage and 
check any additional charging sources if present. 


Reduce the load current at the load output. 
The load may cause current peaks. 
Try reconnecting the load. 





Version 1.0 — 07/2012 Seite 46 von 52 


TRUNZ 


User Manual Survivor 300 Ql water systems 


Display | Meaning [Cause / Remedy 
S rs 


Excessive module current. 

The permissible input current | Reduce the charging current or 
of the controller was module power. 

exceeded. 


Rectify short circuit. Disconnect and reconnect the 
load. 


Short circuit at load output. 


Moon symbol during daylight 
hours: 

e Short circuit at module input 
e No module connected 

e Module connected with 
incorrect polarity 


e Correct the short circuit at module input. Sun 
symbol appears after 10 s. 

e Connect the module. Sun symbol appears after 
15 min. 

e Connect the module with the correct polarity. 


No battery is connected to the | Controller is supplied only by the solar modules. 
controller or the connection Connect the battery and replace the fuse in the 
to the battery is interrupted. battery cable if necessary. 


The battery is connected to 
the controller with the wrong 
polarity. 


Disconnect the battery and reconnect it to the 
controller with the correct polarity. 





8.2 Troubleshooting 


System does not run Batteries are dead Check cable connection to solar panel 


System does not run Main switch is <OFF> Switch the system <ON> 
System does not run No main power 230V Check external power supply and fuses 
Pump does not work Main switch is <OFF> Position switch to “ON” 


Check the system for blocked parts. 
Clean this. Check the inlet pressure PI1 
(must be < 3 bar). If applicable make a 
chemical cleaning of the module or 
prefilter or where necessary replace 
defect / blocked parts (e.g. carbon 
cartridge) 


l Broken or failure electrical Look if the pump is connected and if all 
Pump don't starts ; i 
connection cables and electr. couplings are o.k. 


Feed water hose is not in water 
well located. Pump membrane 
can be broken or pump is 
overheated by dry run 


Feed water hose / prefilter are Check and clean the feed hose and 
Pump makes loud sound . 
blocked prefilter 


There is air in the water 
Pump makes loud sound (bubbles), in the system or in the | Ventilate the system 
module. The pump is overloaded 


Membrane or everywhere in the 
Pump wants start but is switching OFF | system is blocked by dirties and 
after some seconds pump switches of by 
overpressure 


Pump service by an authorized service 
shop. Pump membrane, motor or its 
connections, sealings replace 


Pump does not work 


Position solar panel to the sun or 
connect the system to 230V and load 
battery at first. 


Voltage present? or sufficient 
power in the solar system? 


Pump don't start 





Trunz Water Systems AG  www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 47 von 52 


TRUNZ 


User Manual Survivor 300 Ql water systems 


Problem Possible Reason 


The check valve on pump may 
Pump don't start be faulty or stuck. Clean or replace the pump check valve. 
een e SS AIE eStesiane Activated carbon filter saturated Replace activated carbon cartridge 
smells bad 
l l l . nash Make an Module Integrity Test 
Filtrate is cloudiness / turbid Membrane filter is defect If necessary replace the UF-module 


Raw water analysis 
Heavy metal and salts, Pesticide 
Herbicide, bacteriolog. contamination 


Bad filtrate quality Bad raw water quality 


Multiple backflushing or when the flow 
after app. 10 backflushes is not better 
then make a Chemical Cleaning 


Low filtrate flow Carbon filter is blocked Replace the carbon cartridge 


No filtrate 3-way vave V i NOl CONECI Adjust valve V1 to <Filtration Mode> 
positioned 

No filtrate drain valve V2 not correct Close V2 <Dead End> or close V2 till 
positioned almost closed (<Cross-Flow> 


Check the air pre-pressure in the tank 
membrane. Too high and too low 
pressures are not effective. Charge and 
adjust air pressure with app. 1 bar. 

Use a Ball- or Tire-Pump with 
manometer 


Machine losses water. The case is wet : Check and retighten screw connections. 
inside Screw connections leaky Check if O-rings are present 


Switch ON feed pump and knocking on 
Feed pump is OFF or filter housing. Manometer membrane is 
manometer is uptighted dirty unscrew manometer and clean 
the socket 


Low filtrate flow UF-module is blocked 





Pre-pressure in tank T1 is not 


Low backflush flow and pressure 
correct 





No Inlet Pressure PI1 


Ignore the not shown pressure at PI1 or 
install on own costs a manometer with 
detailed indicating 


Well water is very clean so that 


No Inlet Pressure PI1 
no pressure will be shown 


Electrical failure, Pump failure, 
System stops permanently Controller failure, Pressures are 
out of range, Piping is blocked 


Stop the machine and check all 
mentioned reasons 


Try at first a further 3-fold backflush, 


An 3-fold backflush don't brings higher | UF-Membrane, Prefilter or Chemical cleaning of UF, manually 
filtrate flow rates Carbon Filter are fouled cleaning of Prefilter, replace the carbon 
cartridge 


Well water is very dirty and the Change the filtration mode to 
module is in shortest time <Cross-Flow> > open drain valve V2 a 
blocked little bit 


Very often necessary backflushes, 
Filtration pressure PI1 increase rapid 


No correct connection to solar Check the solar connection and 
panel or a partial area of black positioning of the panel out of shadow 
solar cells is in the shadow with direction to the sun 


The power loading of the battery 
decrease rapidly 


Position the case to a colder place or in 
shadow, provide ventilation to the 
system 


The controller C1 or the charger C2 Hot environment or not enough 
are very hot ventilated Survivor case 





Trunz Water Systems AG  www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 48 von 52 


TRUNZ 


User Manual Survivor 300 Ql water systems 


Problem Possible Reason [Solution 


Check for loss of power at the AC 
outlet. Confirm RCD has not tripped. 

Battery charger C2 — no blue LED No power on AC outlet Check with a meter or an AC test 
light that AC is present at the end of 
your extension cord. 


Confirm all charger cables are 
Battery charger C2 — no blue LED Cable failure connected at battery and that all 
connections are clean and tight. 


With the AC power removed and the 
engine switched off; check the charge 
level of battery with a DC meter. If there 
is no charge level indication 

Battery charger C2 — no blue LED Battery failure for the battery, check each battery with 
a hydrometer to determine if it has one 
or more bad cells. 
(Batteries should always be replaced in 
sets and always the same type.) 


Check reasons. 
All connections are clean and Reverse polarity connections will blow 
tight? Fuses ok? output fuse, resulting in no output 
voltage. 


Battery charger C2 - 
Battery is not charging, Red and Green 
Indicator is <ON> 


With the charger on, read DC voltage at 
the battery. If the reading is less than 
13 volts, proceed with the following: 
A. Disconnect AC power at the AC 
outlet. 
B. Remove charger cables from the 
battery. 
C. Reconnect AC power and read DC 
voltage across the output cable. If 
Battery charger C2 - output voltage is app. 13 volts, then the 
Battery is not charging, Red and Green | Low DC voltage charger is okay and the battery should 
Indicator is <ON> be tested with a hydrometer with the 
charger and the engine off to determine 
if the battery have bad cells. (Batteries 
should always be replaced in sets and 
always the same type.) 
D. If there is no output when trying to 
read DC voltage, check each output 
fuse and replace as needed. If the DC 
voltage at each charger output is less 
than 13.0 volts, contact Trunz Service. 





9. Taking out of Service 
9.1 Temporary Giving Up 


A temporary taking out of service must be defined in several steps: 


a) 1min—8h (1 working day) 
This is a short time stop. The system is filled with water. According to the environment temperatures 
the system can stopped by switching <OFF> the main switch. 
Air-temperatures over 30 °C (environment) forward a microbial growing. 
To be sure that the filtrate is usable for drinking make after switch <ON> a short system ventilation by 
initiating the <Cross-Flow> and then <Dead-End> ... open and close valve V2 short-time. Then close 


Trunz Water Systems AG  www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 49 von 52 


TRUNZ 


User Manual Survivor 300 Ql water systems 


V2 and drain the first filtrate for about 3 - 5 minutes. Don't drink this filtrate during this time. 


b) 1 day- 3 days 
According to the environment temperatures the operating staff must decide if the system should be go 
for longer storage phase or not. In case that the Survivor will be up to 3 days out of service Trunz 
advise to initiate after a 3-day-stop a normal starting up with system ventilation, followed by a 6-fold 
backflush. To be sure that the system will be good flushed initiate the <Cross-Flow> and then <Dead- 
End> (open and close valve V2 short-time) some times alternating. Then close V2 and drain the filtrate 
then for about 8 — 10 minutes. Don't drink this filtrate during this time. 


c) 3 days — 10 days 
When you are sure that the system don't will go in run-mode for longer than 10 days, then you can 
bridge the 10-day period by a flushing of the system all 3 days without to initiate a Long Term Storage 
with filling and flushing of preservation agents. Follow the instruction in item b) for the 3-daily-flush. 


d) Longer than 10 days — up to 3 months 
For so long stop-periods of the system is to initiate a <Long Term Storage> procedure. A 
microbiological growth without chemical disinfection is not to avoid, also not with periodically normal 
flushes. For this procedure will be filled into the system the preservation agent <Propylenglycol>. Before 
a restart of the system for drinking water production the chemical must flushed out of the system. The 
procedure will be described in chapter 9.2.1. 


e) 3 months — 6 months or longer 
After 3 months machine-stop the Glycol fluid must be recirculate in the system. When warm 
environment temperatures then is the fluid to renew / replace. Latest after 6 months the glycol solution 
is to replace / change mandatory. Such a long phase of non-operation and system storage also will be 
named <Winterize> independent of the really season or if in the operating country there is generally a 
winter or not. The procedure will be described in chapter 9.2.2. 


Longer time than 3 days of inactivity the system must be flushed or prepared for a long 


term storage. Elsewise the system will be contaminated strongly by growing 
microbiology. When the system will be filled with preservation solution Glycol, the first 
filtrate for 10 minutes after recommissioning is no drinking water. 

Purge at first the glycol out of the system. 





9.2 Taking the System out of Service 


With designation "Taking the System out of Service" it will be distinguished between a 

<Long Term Storage> and a <Winterize> 

Both methods include a stopping of the system for a longer period and a filling of the system with a 
preservation agent. The preservation should avoid a growing of microorganism in the system. Especially the 
Ultrafiltration membranes would be damaged by feed off the membrane-material by organics. 


OH 
As preservation agent will be used Propylenglycol: ii AN LAK Propylenglycol: C3H802 
C3-Alcohol 
K me coho 
H \ | 
H 


NOTICE 


Tipp: To save Propylenglycol you don't need use the 100 %-age Glycol solution out 


of the supply bin. 
Dilute the Glycol with UF-filtrated clear water 1:5 (1 part Glycol + 5 part Water) 





Trunz Water Systems AG  www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 50 von 52 


TRUNZ 


User Manual Survivor 300 Ql water systems 


9.2.1 Long Term Storage 








Pic. 9.2.1 Long Term Storage 


Remove the Carbon Cartridge 
while Chemical Cleaning VU2 PI2 


< Cross Flow > 
VU1 Plt 


is 


Filtrate V1 






































































































F3 
D < E UF-Module 
V2 F2 5 
slightly open D 
Drain Le 


Filtrate 





10 It. Bucket with a 
Propylenglycol-Solution 














= After stop the Survivor the system is filled with water. 

= Open V2 full to make the system pressure-less. 

= Remove the carbon cartridge 

= Clean the prefilter (strainer F1 & F2) manually. 

= To bring the system into <Long Term Storage> mode we recommend to clean the system with a 
<Chemical Cleaning> to eliminate wastes and foulings. Follow the instructions in chapter 7.4. 
Be sure that no chemical rests from the chem. cleaning remain in the system. Flush good with fresh 
water. Ultrafiltrated water is the best for that so that no new particles contaminate the system after the 
cleaning procedure. 

= Empty the Survivor as good as possible. Lay down all hoses to the ground floor. Crowd back the 
Survivor case vertically. If possible blow air with a compressor on feed-side and on filtrate side into the 
system. Let drop out rests of water. Change the valve opening of V1 sometimes to empty the backflush 
tank T1 too. After this procedure lay down the Survivor to operation position. 

"= Stand your 10-Lt bucket adjacent to the Survivor and hang all hose ends into the bucket. 

= Prepare the preservation solution: 
Put 2 Lt. Propylenglycol (100 %age) into the bucket. Fill up the bucket fully with 8 Lt clean ultrafiltrated 
water (Caution: Don't use dirty well water for mixing of the solution). 
The solution will be mixed by swirling and turbulences of the water. 
Attention: Don't touch the pure Glycol and take care that no Glycol contact the eyes. 

= Bring the valves V1 & V2 into <Cross-Flow> mode. 

= Start the survivor with main switch. At first the Survivor will be filled. The water level in the bucket 
declines. Circulate now as long as the water level in the bucket is constant. 
Have regard that the feed hose don't primes air in the system during filling procedure. 

= The complete Survivor is now filled. Stop the Pump with main switch. 

= To avoid solution evaporation or waste-intake close the Red Caps of the Venting Units VU1 & VU2. 
Remove the hoses from the Survivor. Close the hose nipple on the Survivor with a plug or a plastic 
cover too. 

= Drain the rest of solution in the bucket into the sewage pit. Glycol is biodegradable and not dangerous 
for the environment. 

9.2.2 Winterize 


Winterize is the storage of the Survivor longer than 6 months. The preservation procedure is the same like 
the <Long Term Storage> what was described in the previous chapter. The difference to the <Long Term 
Storage> is that the preservation solution must be renewed / replaced latest after 6 months storage. 


Trunz Water Systems AG  www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 51 von 52 


TRUNZ 


User Manual Survivor 300 Ql water systems 


Attention: The Glycol-solution lose the preservation-effectivity in the course of time. That's why it's 
important that the solution-replacement don't will forget. 


10. Disassembly, Disposal 


At the time of disposal the valid regulations of the according country are to be followed. 
Batteries and other equipments are to disposal separate according to regional provisions. 


11. Appendix 


A1 Packing List / Spare Part List (Service Kit) 
A2 Survivor Process Flow Diagram 

A3 Self-Made Protocol Template (Blank List) 
A4 Wiring Diagrams 

A5 Declarations of Conformity 


Trunz Water Systems AG  www.trunzwatersystems.com Version 1.0 — 07/2012 Seite 52 von 52