GM-14915067 Rev 4 PPk-V3.fm

Survival, Water, Medical Field Manuals

Military Manuals

Document text

ProPak-V3™ 





QUICK START GUIDE 


This guide provides the basic information 
you need to setup and begin using your 
new ProPak-V3. For more detailed 
information on the installation and 
operation of your receiver, please refer to 
the user manuals provided on the 
accompanying CD. The most up to date 
revisions of these manuals can be found on our website at http:// 
www.novatel.com/Downloads/docupdates.html. To order a 
printed copy of the manuals, free of charge, follow the 
instructions given on the enclosed User Manuals postcard. 

The ProPak-V3, is capable of communication with an Inertial 
Measurement Unit (IMU) through its AUX port. If applicable, 
refer to your SPAN for OEMV Technology User Manual and its 
Quick Start Guide for more information. There are also L-Band 
and/or GLONASS-capable models available. 

The ProPak-V3 provides a USB connection through its COM1 
port. The USB drivers, along with installation instructions, are 
available in the USB Drivers directory of the CD provided. An 
installation program for NovAtel’s PC Utilities, including the CDU 
(Control and Display Unit) user interface, and the OEMV 
Software Development kit are also on the CD. 


BOX CONTENTS 


In addition to this Quick Start Guide, the following is provided 
with your ProPak-V3: 
e 1 power adapter cable 
e 1 USB serial cable 
e 2DB-9 serial cables (1 straight through, 1 null modem) 
e 1 I/O cable 
e 1 CD containing: 
e NovAtel’s PC Utilities’ installation program 
e Product documentation, including user manuals 
e The OEMV Software Development kit 
e OEMV Quick Reference Guide 
e User Manuals postcard for requesting printed manuals 





ADDITIONAL EQUIPMENT REQUIRED 


The equipment listed below is required for a typical setup: 
e A Windows-based PC with an RS-232 DB9 or USB port 
e One of the following: 
e Astandard 12 VDC power adapter outlet, or 
e A6-18 VDC power supply and a power cable 
with a 4-pin LEMO plug (LEMO part number 
FGG.0B.304.CLAD52Z) at the receiver end! 

e A quality GNSS antenna, such as NovAtel’s GPS-702, 
or GPS-532 for airborne/high speed applications. For L- 
Band corrections use the GPS-702L antenna or for 
GLONASS applications use the GPS-702GG antenna. 

e An antenna cable with a TNC male connector at the 
receiver end, such as NovAtel’s C016 model 


SETTING UP YOUR PROPAK-V3 


Complete these steps to connect and power your ProPak-V3. 
1. Mount an antenna on a secure, stable structure with an 
unobstructed view of the sky. 


Using a coaxial cable, connect the antenna to the GPS port, 
which is found on the back face of the ProPak-V3. 


——_—_—— OO 


MS 


—— 



































3. Connect the COM7 port on the receiver to a DB-9 or USB 
serial port on the PC. If you are using a USB connection, 
install the USB drivers available on the CD provided. 


1.If an alternative power source is preferred, the automobile power adapter can 

be cut off from the power cable. The exposed wires (red and orange for positive, 
brown and black for negative) can then be tied to a supply capable of at least 5 

W. The use of a 3 A slow-blow fuse is recommended (6A for SPAN applications). 
Also for SPAN, the input voltage range becomes +9 to +18 VDC. 





















Line up the red mark on the power cable’s connector with 
the red mark on the receiver's PWR connector. Insert the 
power cable connector in the PWR port. 


= N 
AA SY 
— © 


© || 


| 


O NG | 
@ D 
I s An } | 


|@ 


YV 


| d 
e) = 








Plug in the adapter and/or connect and turn on the power 
supply. The LED above the PWR port glows red when the 
ProPak-V3 is properly powered. 


INSTALLING THE PC UTILITIES 


Once the ProPak-V3 is connected to the PC, antenna, and 
power supply, install NovAtel’s PC Utilities. 


1. Start up the PC. 


2. Insert the accompanying CD in the CD-ROM drive of the 
computer. 


3. Select Install the OEMV GPS PC Utilities from the window 
that is automatically displayed. If the window does not 
automatically open when the CD is inserted, select Run from 
the Start menu and select the Browse button to locate 
Setup.exe on the CD drive. 


4. Install the PC Utilities by advancing through the steps 
provided in the NovAtel PC Utilities setup program. 


WWww.novatel.com 











ESTABLISHING RECEIVER COMMUNICATION 
To open a serial port to communicate with the receiver, complete 
the following. 


1. Launch CDU from the Start menu folder specified during the 
installation process. The default location is Start | Programs | 
NovAtel OEMV | OEMV PC Software. 


2. Select Open.... from the Device menu. 





View Tools Help 








Chrl+0 
| Close Config 


Active Configs d 


3. Select the New... button in the Open dialog box. 


— Open | 
Cancel | 





Delete | 





4. Enter a name for the new device configuration in the Name 
field of the New Config dialog box and select the Settings 
button. 


New Contig 


Hame 


|ProPak-¥3 
Cancel 


Devic 
[Serial -] Settings... | Help 


Startup Option 


. AutoStart . AutoReset 


MW Update Log Definitions for Convert 





5. Select the PC serial port the ProPak is connected to from the 
PC Port drop-down list. 


6. Select 57600 from the Baud Rate list. 
7. Uncheck the Use hardware handshaking checkbox. 
8. Select OK to save the settings. 


Serial Device Settings 


PL Pork | COM DE 


Baud Aate: [57600 -] 


. Passive connection 
[ Read-only 


Cancel 


Help 





9. Select the OK button to close the New Config dialog box and 
create the new device configuration. 


10. Select the new configuration from the Available device 
configs list in the Open dialog box. 


11. Select the Open button to open communications with the 
ProPak-V3. 








Available device contigs 


As CDU establishes the communication session with the 
receiver, a progress box is displayed. 





ProPak-W3 COMO at 57600 Baud 


Once CDU is connected, the progress box disappears and 
several windows open, including the Console window. CDU 
is now ready to be used to view status information, enter 
commands, or log data. 


USING CDU 


CDU provides access to key information about your receiver and 
its position. The information is displayed in windows accessed 
from the View menu. For example, select Position Window from 
the View menu to display the position solution of the receiver. To 
show details of the GNSS and geostationary (SBAS) satellites 
being tracked, select a Tracking Status Window (GPS or 
GLONASS) from the View menu. Select Help from the main 
menu for more details on CDU, its windows and features. 


DETERMINING WHEN THE POSITION IS VALID 


When the receiver has a valid position, the Solution Status field 
in CDU’s Position window shows Computed. 


Solution Status Computed 


ProPak-¥3 - Constellation 


11/11 PRN 24 Az. 92.77 Elev. 52,4" 
a re: Good 





ProPak-¥3 - GPS Channel Tracking Status [x] 


Signal /Noise Ratio (GPS. =) 


INN 





PRN S E T S E 
a8 900 (10 02) 13) 1415 


Hm Ea 


m 
WE 


Good ( +45] 


Ere E 
SBAS 


Average (>75) 
Poor (<35) 





ENTERING COMMANDS 


The ProPak-V3 uses a comprehensive command interface. 
Commands can be sent to the receiver using the Console 
window in CDU, which is opened from the View menu. Enter 
commands in the text box at the bottom of the Console window. 


T 
w: 
£ 

|< 








The following information is important when entering commands: 


e Commands can be entered in three formats: 
e ASCII (log bestposa) 
e Abbreviated ASCII (log bestpos) 
e Binary (log bestposb). 
Abbreviated ASCII is the best format to use when you 


wish to work with the receiver directly. For data 
collection, use ASCII or Binary. 


e Press the Enter key to send the command string to the 
receiver. 


e The commands are not case sensitive. 


The OEMV Family Quick Reference Guide provided with the 
receiver lists the available commands and the parameters they 
use for the Abbreviated ASCII format. 


You must use COM3 instead of AUX to send commands or log 
requests on the ProPak-V3 AUX port. For example, the COM3 
port may be used when communicating with an IMU or another 
receiver for differential operation. Refer to your SPAN for OEMV 
Technology User Manual or OEMV Family Installation and 
Operation User Manual for more details on alternative 
positioning modes of operation. 


LOGGING DATA 


An extensive collection of logs has been created to capture the 
data your ProPak-V3 receives and processes. These logs can 
be directed to any of the ProPak-V3’s serial ports and can be 
automatically generated when new or changed data becomes 
available or at regular intervals. The available logs are listed in 
the OEMV Family Quick Reference Guide. 


To log data, use the LOG command. For example, to log the 
pseudorange position to COM 2 every 30 seconds, enter the 
following: 


LOG COM2 PSRPOS ONTIME 30 


Logs can be generated in one of three formats: ASCII, 
Abbreviated ASCII, or Binary. Refer to the OEMV Family 
Firmware Reference Manual (OM-20000094) for information on 
the LOG command, specifying the output format, and the 
detailed contents of each log. 


If you prefer, CDU provides a graphical interface for configuring 
data logging. Select Logging Control Window from the Tools 
menu. In the Logging Control window, you can select which logs 
to capture and choose to which ports to send the data. In 
addition, you can specify a file in which to save the data. 


®©® @ @ © 
comi (Current Port) 


1 


G: \NOVATEL\DATA\CDU Test May2006\LogginInfoTest 
Cel D) 55 
fe] (10s 


(+1.005) BESTPOSB 


(+3.005) IONUTCE 





ENABLING SBAS POSITIONING 
ProPak-V3 models are also capable of SBAS positioning. This 


positioning mode is enabled using the SBASCONTROL command. 


The following commands are typically used to enable WAAS 
(North America) and EGNOS (Europe) respectively: 
SBASCONTROL ENABLE WAAS 
SBASCONTROL ENABLE EGNOS 


Once enabled, the Position Type field shown in CDU’s Position 
window should change from Single to WAAS and you may see 
SBAS satellites in the Constellation window. 


ProPak-VS - Position a 


S1.116794027*°+ 0.9m 
-114.038863221"+ 0pm 
1M63.555m£  1.50m 


Latif abe 
Longitude 
Height (MSL) 


Solution type HARS 
Tort correction Mul ti- frequency 





ENABLING L-BAND POSITIONING 


L-Band equipped receivers allow you to achieve sub-meter 
accuracy. To use this positioning mode, you must enable L-band 
tracking to the Canada-Wide Differential GPS (CDGPS) or 
OmniSTAR signal. A subscription to OmniSTAR is required to 
use the OmniSTAR VBS, XP or HP service (visit http:// 
www.omnistar.com with your receiver serial number ready). The 
CDGPS signal is free and available without subscription over 
North America (visit hitp://www.cdgps.com). 
The ASSIGNLBAND command allows you to set OmniSTAR or 
CDGPS base station communication parameters. It should 
include a relevant frequency and data rate. The frequency 
assignment can be made in Hz or KHz. For example: 

Hz: assignlband omnistar 1536782000 1200 


KHz: assignlband omnistar 1536782 1200 


A value entered in Hz is rounded to the nearest 500 Hz. 


To confirm you are tracking an L-Band signal, log the L-Band 
status information by entering: log lbandstat. For example, 
if you are receiving CDGPS, the fifth field after the header 
should be 00c2: 


lbandstata coml 0 43.5 finesteering 1295 
149951.671 00000000 976fF 34461; 
1547546977 46.18 4541.0 0.00 00c2 00f0 


To specify the correction source, use the PSRDIFFSOURCE 
command as shown in the examples below: 


PSRDIFFSOURCE OMNISSTAR Or, 
PSRDIFFSOURCE CDGPS 
otherwise it is left at the default AUTOMATIC. 


ò< Refer to the OEMV Family Firmware Reference Manual for more 
on individual L-Band, GLONASS or SBAS commands and logs. 


EXTERNAL OSCILLATOR 


For certain applications requiring greater precision than what is 
possible using the on-board 20 MHz, voltage-controlled, 
temperature-compensated crystal oscillator (VCTCXO), you 
may wish to connect the ProPak-V3 to an external, high-stability 


oscillator. The external oscillator can be either 5 MHz or 10 MHz. 


Installation consists of connecting a cable from the external 
oscillator to ProPak-V3’s external oscillator port, labelled OSC. 


Once the external oscillator has been installed, issue the 
EXTERNALCLOCK command to define the clock model (for 
example, cesium, rubidium or ovenized crystal). If the input clock 
rate is 5 MHz, you must issue the EXTERNALCLOCK command 
to change the 10 MHz default rate. 


REAL-TIME KINEMATIC (RTK) POSITIONING 


Corrections can be transmitted from a base station to a rover 
station to improve position accuracy. The base station is the 
GNSS receiver which is acting as the stationary reference. It has 
a known position and transmits correction messages to the rover 
station. The rover station is the GNSS receiver which does not 
know its exact position and can receive correction messages 
from a base station to calculate differential GNSS positions. 


In most cases you need to provide a data link between the base 
station and rover station (two NovAtel receivers) in order to 
receive corrections. SBAS and L-Band corrections can be 
accomplished with one receiver and are exceptions to the base/ 
rover concept. Generally a link capable of data throughput at a 
rate of 9600 bits per second, and less than 4.0 s latency, is 
recommended. 


Once your base and rover are set up, you can configure them for 
RTCA, RTCM, RTCMV3, CMR+ or CMR corrections. An RTCM 
example follows (replace the latitude, longitude and height 
coordinates shown with those of your base): 


Base 


interfacemode com2 none rtcm off 


fix position S1.113598042 =—114.0435c013 


LOD 24105 


log comz 
Log, Comz 
log comz 


log com2 


Rover 


rtcem3 ontime 10 
rtem22 ontime 10 1 
rtcm1819 ontime 1 


rtcem1i ontime 5 


interfacemode com2 ricm none off 


ProPak-V3’s RT-2 and RT-20, with AdVance RTK, are real-time 
kinematic software products developed by NovAtel. Optimal 
RTK performance is achieved when both the base and rovers 
are NovAtel products. However, AdVance RTK will operate with 
equipment from other manufacturers when using RICM 


messaging. 


RT-2 and RT-20 are supported by GPS-only and 
GPS+GLONASS OEMV-based models. Also, RT-20 with 
GPS+GLONASS provides faster convergence. 


ò< 1. Refer to the GPGST log’s usage box in the OEMV Firmware 
Reference Manual for a definition of RMS and other statistics. 


2. For more base/rover configurations, search the key words 
“rover base” on our Knowledge Database at: 


http://www.novatel.com/support/knowledgedb.htm 


POST PROCESSING 


Post-mission data processing refers to when the GNSS data 
collected by the receiver is processed after the entire data- 
collection session is complete. 


OEMV-based output is compatible with post-processing 
software from the Waypoint Products Group, NovAtel Inc. For 
details, visit our website at: 


http://www.novatel.com/products/waypoint_pps.htm 
MOUNTING BRACKET 


A mounting kit is provided with the ProPak-V3 enclosure 
enabling you to mount the receiver to a surface. The mounting 
kit is not designed for use in high-dynamics/vibration 
environments. For details on how to install the ProPak-V3 with 
its mounting bracket, refer to its instruction sheet. 


QUESTIONS OR COMMENTS 


If you have any questions or comments regarding your ProPak- 
V3, please contact NovAtel using one of these methods: 


Email: [email protected] 

Web: 

Phone: 1-800-NOVATEL (U.S. & Canada) 
+1-403-295-4900 (International) 


Fax: +1-403-295-4901 


www.novatel.com 


=. R 
Novatel Quick Start Guide: a7 &) 


© Copyright 2007 NovAtel Inc. All rights reserved. 

Printed in Canada on recycled paper. Recyclable. 

Unpublished rights reserved under international copyright laws. 
GM-14915067 Rev 4 


ProPak-V3: == ROHS 


2007/06/26