The use of microfabricated and microfluidic structures in biomedical research has been rapidly expanding in recent years, but many research applications of these devices require customization, and new applications typically require several design iterations for troubleshooting. In an effort to bring the necessary technical capabilities and knowledge to do so into biomedical laboratories, we have developed a basic in-house microfabrication facility accessible to researchers across the intramural program. Although the resolution, device yield, and complexity are somewhat lower than those achievable with a dedicated cleanroom, they are nonetheless sufficient for many experiments on cells. Furthermore, the instrumentation complexity, fabrication cost, and turnaround time are greatly reduced, enabling rapid cycling through design parameters as needed.

We are able to reliably pattern single- and multi-layer template features with lateral dimensions of less than 2 microns, and with heights ranging from a few microns to a few hundred microns. We have developed protocols for using these templates to generate microstructured PDMS, agarose, and PEGDA hydrogels, including techniques for making and manipulating thin (<200 micrometer) PDMS layers for use in multilayer devices and bottomless structures. We can also perform surface modification of PDMS and other polymers, including the irreversible bonding of PDMS to glass, and have developed techniques for connecting devices to flow-control instruments such as syringe pumps and pressure controllers. We also have protocols for generating micropatterns of biomolecules on surfaces using microcontact printing or selective UV exposure, as well as protocols for generating monodisperse droplets and hydrogel beads.

In addition, we have the ability to deposit and pattern metal layers, as well as a heated hydraulic press for hot-embossing thermoplastics, including PMMA, polycarbonate, and COC. We also have a programmable razor cutter which we can use with pressure-sensitive adhesive to directly make thin film structures with heights ranging from 25 to a few hundred microns, and sub-millimeter lateral dimensions. This is a low-cost and convenient method for several applications, including the ready fabrication of flow cells with two glass walls, or for fluidic confinement over already-functionalized surfaces.

Finally, we continue to work on finite element modeling of transport in microfabricated structures, developing models for oxygen delivery in a bioreactor with micropillars and for chemokine concentration in a microfluidic hydrogel device.

These capabilities have found application in a number of projects, representing a broad variety of interests and institutes. In addition to the representative projects discussed below and others still in the early stages, we have also trained researchers in basic microfabrication techniques, including personnel from other laboratories in NEI, NIAID, NHLBI, NCI, NICHD, NINDS, NIDCD, NIDDK, and NIBIB. Some examples of recent and ongoing projects are:

1) A collaborative effort with LSB, NIAID, to study chemotaxis, currently focusing on the decision-making of single cells exposed to competing solution gradients. Earlier efforts with this group looked at chemotaxis of primary immune cells in 3-D collagen matrices, using a microfluidic agarose device to generate reproducible time-varying spatial gradients on a platform compatible with high-resolution fluorescence and two-photon imaging.

2) The design, fabrication, modeling, and use of an oxygen-transmissive membrane, patterned with a micropillar array to deliver oxygen to three-dimensional cell culture volumes with in vivo-like spatial distribution, in collaboration with LCB, CCR, NCI and SPIS, CIT. Because the pillar spacing is approximately equal to typical intercapillary distances (200 microns), cells in a Matrigel layer surrounding the pillars can be maintained under hypoxic conditions in an extended 3D volume. We have recently started working with researchers in LAMB, NHLBI to employ their recently developed FLIM-FRET probe for intracellular oxygen to directly image spatial and temporal variations in intracellular oxygenation in these structures.

3) In collaboration with researchers in the SAB, NIAMS, the design and fabrication of a vascular mimetic to study the effects of SLE-induced biophysical changes to neutrophils on their transport through the pulmonary microvasculature.  

4) The use of a microfluidic channel together with custom instrumentation developed in LCMB, NICHD in order to separate the effects of pressure and rapid (msec) shear transients on cultured neural cells, in order to gain a better understanding of the cellular mechanisms of traumatic brain injury. Our group has fabricated the microchannels, performed modelling aimed at understanding the shear transients experienced by the cells as a function of the bulk flow, and consulted extensively on how best to interface the microchannel with the existing instrumentation.

5) A new project with the BRS, VRC, NIAID to improve the throughput and reliability of their droplet-based yeast display system for interrogating antibody libraries in order to probe humoral immune responses to vaccination and natural infection.  Past work with the technology has looked at responses to Ebola vaccination, and the system is intended to look at patient responses to Sars-Cov-2 vaccines.  Our initial work has focused on fabricating a simple microfluidic flow-focusing droplet generator for coencapsulation of B-cells and superparamagnetic oligo beads; current efforts are extending this design to parallel nozzles for faster processing of single samples and parallel processing of multiple samples.  

6) In collaboration with LCB, NCI, development of in vitro models to complement measurements on cell migration in zebrafish to advance understanding of the mechanisms for cell migration and metastasis.

7) In collaboration with researchers in NINDS and NICHD, the development of devices to enable selective harvesting of axons from cultured neurons for biochemical analysis, in order to readily be able to generate enough material for downstream measurements.

8) In collaboration with researchers from the LIG, NIAID, the development of PDMS/glass microfluidic devices for studying chemotaxis. The first device design enables measurements of chemotaxis of dictyostelium in 2D chambers on a platform compatible with high-resolution imaging; the generated gradients can be directly measured with a fluorescent tracer, and the system operates without pumps.

Terms: <2-photon><2019 novel coronavirus><2019-nCoV><3-D><3-Dimensional><3D><3D cell culture><3D culture><Adhesives><Agarose><Axon><B blood cells><B cell><B cells><B-Cells><B-Lymphocytes><B-cell><Biochemical><Biomedical Research><Biophysics><Bioreactors><Blood Neutrophil><Blood Polymorphonuclear Neutrophil><Blood Vessels><Brachydanio rerio><Brain Trauma><CCR><Cell Body><Cell Locomotion><Cell Migration><Cell Movement><Cells><Cellular Migration><Cellular Motility><Chemotactic Cytokines><Chemotaxis><Collaborations><Collagen><Complement><Complement Proteins><Complex><Consult><Custom><Danio rerio><Decision Making><Deposit><Deposition><Development><Device Designs><Device or Instrument Development><Devices><Dictyostelium><Dimensions><Discipline><Ebola><Elements><Equipment><Exposure to><Exposure to ultraviolet radiation><FRET><Film><Fluorescence><Fluorescence Resonance Energy Transfer><Förster Resonance Energy Transfer><Glass><Harvest><Homologous Chemotactic Cytokines><Human Resources><Hydrogels><Hypoxia><Hypoxic><Image><Immune><Immune response><Immunes><Immunological response><Infection><Institutes><Intercrines><Intramural Program><Intramural Research Program><Investigators><Knowledge><Laboratories><Lateral><Leanness><Liquid substance><Lung><Lung Respiratory System><Lupus Erythematosus Disseminatus><Manpower><Marrow Neutrophil><Measurement><Measures><Membrane><Metals><Metastasis><Metastasize><Metastatic Lesion><Metastatic Mass><Metastatic Neoplasm><Metastatic Tumor><Methods><Microfabrication><Microfluidic Device><Microfluidic Lab-On-A-Chip><Microfluidic Microchips><Microfluidics><Modeling><Modification><Motility><Msec><NHLBI><NIAID><NIAMS><NIBIB><NICHD><NIDCD><NIDDK><NIH><NINDS><National Heart, Lung, and Blood Institute><National Institute of Allergy and Infectious Disease><National Institute of Arthritis and Musculoskeletal and Skin Diseases><National Institute of Biomedical Imaging and Bioengineering><National Institute of Child Health and Human Development><National Institute of Children's Health and Human Development><National Institute of Diabetes and Digestive and Kidney Diseases><National Institute of Neurological Diseases and Stroke><National Institute of Neurological Disorders and Stroke><National Institute on Deafness and Other Communication Disorders><National Institutes of Health><Neoplasm Metastasis><Nerve Cells><Nerve Unit><Neural Cell><Neurocyte><Neurons><Neutrophilic Granulocyte><Neutrophilic Leukocyte><O element><O2 element><Oligo><Oligonucleotides><Operating System><Oxygen><Oxygen Deficiency><PMMA><Pattern><Poly(methyl methacrylate)><Polymers><Polymethyl Methacrylate><Polymethylmetacrylate><Polymethylmethacrylate><Polymorphonuclear Cell><Polymorphonuclear Leukocytes><Polymorphonuclear Neutrophils><Printing><Process><Protocol><Protocols documentation><Pump><Reproducibility><Research><Research Personnel><Researchers><Resolution><Resource Sharing><SARS-CoV-2><SARS-CoV2><SARS-associated coronavirus 2><SARS-coronavirus-2><SARS-related coronavirus 2><SIS cytokines><SLE><Sampling><Secondary Neoplasm><Secondary Tumor><Sepharose><Severe acute respiratory syndrome coronavirus 2><Si element><Silicon><Spatial Distribution><Structure><Surface><Syringes><System><Systemic Lupus Erythematosus><Systemic Lupus Erythematous><Systemic Lupus Erythmatosus><Techniques><Technology><Thinness><Time><Tracer><Training><Transmission><Traumatic Brain Injury><UV Radiation Exposure><UV exposure><Ultraviolet Radiation Related Exposure><Ultraviolet radiation exposure><United States National Institutes of Health><Vaccination><Vaccines><Work><Wuhan coronavirus><Yeasts><Zebra Danio><Zebra Fish><Zebrafish><antibody libraries><base><biological systems><biophysical foundation><biophysical principles><biophysical sciences><cancer metastasis><cell motility><chemoattractant cytokine><chemokine><cost><design><designing><developmental><device development><disseminated lupus erythematosus><experience><experiment><experimental research><experimental study><fluid><high resolution imaging><host response><imaging><immunoresponse><improved><in vitro Model><in vivo><instrument><instrument development><instrumentation><interest><liquid><matrigel><membrane structure><microfluidic chip><millisecond><mimetics><neuronal><neutrophil><oligos><operation><parallel processing><patient response><patient specific response><personnel><polycarbonate><pressure><programs><prototype><pulmonary><response><responsive patient><simulation><spatial temporal variation><superparamagnetic><superparamagnetism><systemic lupus erythematosis><three dimensional><three dimensional cell culture><transmission process><traumatic brain damage><tumor cell metastasis><two-photon><ultraviolet exposure><vascular><µfluidic>