SLICK STEEL Corporate Headquarters
SLICK STEEL Corporate Headquarters
6855 Lyons Technology Circle • Suite 18
Coconut Creek • FL • 33073 Tennessee Office
1107 Balllewood Street
Franklin • TN • 37069
CUSTOMER QUOTE
Name
Company
Street
City
State
Country Brace Gordon
LSJ Employees. LLC
US Virgin Islands
Project Building I
Location Street
Engineering
Width
Length 80'
Height 18'
Root Pitch 1.5:12
Left Endwall
Right Endwall
Front Sidewall
Back Sidewall Code IBC 2009
Wind Load 145 MPH
Exposure C
Live Load 20
Reducible Yes
Spacing 28% 24'. 2B'
Spacing 28% 24'. 2B'
Spacing 4@20'
Spacing 4@20'
Primary Frame Coating Red Oxide Primer Tel
Fax
Email
City TBD
State ZZ
Snow Gnd 0
Snow Roof 0
Snow Is
Snow Ct
Snow Ce Zip TBD
Seismic Ss
Seismic S1
Collateral Quote Date 01/31/2017
Valid Through 02/07/2017
Project ID BS23416
Sales Rep Brian Buck
Page 1 of 4
County TBD
Country US Virgin Islands
Shell Enclosed
Column Tapered
Base Deluxe Formed Trim
0.5 Frame Gable Symmetrical
Type Full-Load Expandable Frame
Type Non-Expandable Bearing Frame
Type N/A
Type N/A Bracing None
Bracing Cable
Bracing Cable
Bracing Cable
Secondary Frame Coating Red Oxide Primer Occupancy Normal
Thermal Unheated
Snow Exp Sheltered
Girt Flush
Girt Flush
Girt Bypass
Girt Bypass
Roof Panel Gauge 24 Style PBR Screw Type•Length Long Life-1 1/44 Color Not Specified
Wall Panel Gauge 24 Style PBR Screw Type•Length Long Life-1 1/4• Color Not Specified
Engineering EXPORT BUILDING with final destination of XXXX via PORT )000( with unloading and freight forwarding by others. Export package includes
Notes extra sheeting. nuts. bolts. fasteners, gins and pudins with all rollup doors specifically crated for export to provide additional protection. It is the
customer's responsibility to VERIFY All CODES & LOADS used to design this budding as being in accordance with local requirements. Total
weight is estimated as XXXXX lbs. COD amount is to be paid in full 2 weeks prior to delivery to port.
Building Pricing
Oty
1 Description
Base Building as per Engineering Specifications Included
1 Stamped Engineered Bulking Drawings (3 Sets) Included
1 Erecling Drawings (2 Sets) Included
1 Letter of Certification Included
1 Anchor Boll Plans Included
1 LEW Bay #1 Open to Building "B" Included
1 Mod-2 design. Columns at 28 From Back Side Wall Included
1 Full Trim Package Including: Corner Trim, Eave Trim. Sculptured Rake Trim Included
1 Die-formed Ridge Cap Included
1 Closure Strip Package Included
1 Gutters & Downspouts Included
7 Framed Opening Standard Misc. Sizes For CUSTOMER Provided Louvers Included
1 Framed Opening Standard. 12' x it. LEW, Bay #2.5' From Column Included
1 Framed Opening Standard, 12' x 16', LEW. Bay #3. 12' From Column Included
1 Framed Opening Standard. 12' x REW. Bay #1, 5' From Column Included
1 Framed Opening Standard, 12' x 16', REW. Bay 92.8' From Column Included
4 Rollup Door Windlock Certified Non-Insulated wr Chainhoist 12' x 16' Included
1 Roof & Wall Insulation 37 R10 WMP•VR w/ Starter Roll w/ Patch Tape Included
1 Building & Accessory Freight To Port In Ronda Included
Florida Tennessee Webslte
EFTA00798572
SLICK STEEL Corporate Headquarters
6855 Lyons Technology Cute • Suite 18
Coconut Creek • FL • 33073 Tennessee Office
1107 Battlewood Streel
Franklin • TN • 37069
CUSTOMER QUOTE
Name Brice Gordon
Company LSJ Employees. LLC
Street
City
State
Country US Virgin Islands
Project Building 2
Location Street
Engineering
Width 28'
Length 25'
Height 16'
Roof Pitch 1.5:12
Left Endwall
Right Endwall
Front Sidewall
Back Sidewall Code IBC 2009
Wind Load 145 MPH
Exposure C
Live Load 20
Reducible Yes
Spacing 28'
Spacing 28'
Spacing 25'
Spacing 25'
Primary Frame Coating Red Oxide Primer
Roof Panel
Wall Panel Tel
Fax
Email
City TBD
State ZZ
Snow Gnd 0
Snow Roof 0
Snow is
Snow CI
Snow Ce Zip TBD Quote Date 01131/2017
Valid Through 02/07/2017
Project ID BS23416
Sales Rep Brian Buck
Page 2 of 4
County TBD
Country US Virgin Islands
Seismic Ss Shell
Seismic S1 Column Tapered
Base
Collateral 0.5 Frame
Type Half-Load Non-Expandable Frame
Type Half-Load Non-Expandable Frame
Type N/A
Type N/A Bracing None
Bracing None
Bracing None
Bracing None
Secondary Frame Coating Red Oxide Primer
Gauge 24 Style PBR Screw Type-Length Long Life-1 1/4" Color Not Sped tied
Gauge 24 Style PBR Screw Type-Length Long Life-1 1/4' Color Not Specified
Engineering REW of Building Attaches to LEW of Building 'X
Notes
Building Pricing
Oty
1 Description
Base Building as per Engineering Specifications Included
1 Stamped Engineered Builchng Drawings (3 Sets) Included
1 Erecting Drawings (2 Sets) Included
1 Letter of Certification Included
1 Anchor Bolt Plans Included
1 BSW Open to 10' for 12" Poured Concrete Wall Included
1 LEW Open To Existing Bldg Same Width. Height. Roof Pitch Included
1 Full Trim Package Including: Corner Trim, Eave Trim. Sculptured Rake Trim Included
1 Die-formed Ridge Cap Included
1 Closure Strip Package Included
1 Gutters & Downspouts Included
1 Canopy Roof Extension BSW 4' Entire Length. Sheeted 6' To Top Of Existing Wall Included
1 Framed Opening Standard 1Z x 1Z For Rollup Door Included
1 Framed Opening Standard Misc. For CUSTOMER Supplied Louver Included
1 Rollup Door Windlock Certified Non-Insulated vd Chainhoist 12' x 12' Included
1 Roof & Wall Insulation 3"/ RIO WMP-VR w/ Starter Roll w/ Patch Tape Included
1 Building & Accessory Freight To Port In Florida Included Occupancy Normal
Thermal Unheated
Snow Exp Sheltered
Girt Flush
Girt Flush
Girt Bypass
Girt Bypass
Florida Tennessee Website
EFTA00798573
SLICK STEEL Corporate Headquarters
6855 Lyons Technology Circle • Suite 16
Coconut Creek • FL • 33073 Tennessee Office
1107 Balllewood Street
Franklin • TN • 37069
CUSTOMER QUOTE
Name Brice Gordon
Company LSJ Employees. LLC
Street
City
State
Country US Virgin Islands
Project Building 3
Location Street
Engineering
Width 32t
Length 47'6"
Height 16'
Root Pitch 1.5:12 Code IBC 2009
Wind Load 145 MPH
Exposure C
Live Load 20
Reducible Yes
Left Endwall Spacing NA
Right Endwall Spacing NA
Front Sidewall Spacing NA
Back Sidewall Spacing NA
Primary Frame Coating Red Oxide Primer
Root Panel Gauge 24 Style PBR
Wall Panel Gauge 24 Style PBR
Engineering Materials Only included to resheet customers existing building as per architectural drawings. Includes all Wall Sheeting. Roof Sheeting. Ridge
Notes Caps. Mastic. Closure Ships and Fastners. Colors to match new building colors(tbd by customer). Tel
Fax
Email
City TBD
State ZZ
Snow Gnd 0
Snow Roof 0
Snow Is
Snow Ct
Snow Ce
Type
Type
Type
Type Zip TBD Quote Date 01/31/2017
Valid Through 02+07/2017
Project ID BS23416
Sales Rep Brian Buck
Page 3 of 4
County TBD
Country US Virgin Islands
Seismic Ss Shell
Seismic S1 Column Tapered
Base
Collateral 0.5 Frame
Non-Expandable Bearing Frame
Non-Expandable Bearing Frame
N/A
N/A Bracing Cable
Bracing Cable
Bracing Cable
Bracing Cable
Secondary Frame Coating Red Oxide Primer
Screw Type-Length Long Life.1 1/4'
Screw Type-Length Long Life-1 1/4' Color Not Specified
Color Not Specified Occupancy Normal
Thermal Unheated
Snow Exp Sheltered
Girt Flush
Girt Flush
Girt Bypass
Girt Bypass
Building Pricing
Oty Description
Base Building as per Engineering Specifications Included
Included 1 Die-formed Ridge Cap
1 Closure Strip Package Included
1 Building 8 Accessory Freight to Port In Florida Included
Florida Tennessee Webslte
www.bucksteel.com
EFTA00798574
SLICK STEEL Corporate Headquarters
6855 Lyons Technology Circle • Suite 18
Coconut Creek • FL • 33073 Tennessee Office
1107 Battlewood Street
Franklin • TN • 37069
CUSTOMER QUOTE
Name Brice Gordon Tel Quote Date 01131/2017
Company LSJ Employees. LLC Fax Valid Through 02/07/2017
Street Email Project ID BS23416
City Sales Rep Brian Buck
State
Country US Virgin Islands Page 4 of 4
Project Price
Freight
Project Total 106.850.00 108850.00
Included
IMPORTANT NOTES - PLEASE READ
• This quote is based on Buck Steers interpretation of plans and/or conversations with the customer, Buck Steel is NOT responsible for
any errors and/or ommissions.
• Carefully check this quote for completeness and verify the accuracy of the information contained within.
• This quote is valid through 2,7/2017. and is subject to review of pricing. Revisions to quote may result in a price adjustments.
• Erecting is NOT included in this quote, unless specifically listed.
• Erecting estimate is based upon. but not limited to. pad being accessible for a clear 25' around entire building, no trees, powerlines or
equipment which may interfere with erecting. and power supplied to slab. Erecting estimate does not take into consideration any OSHA,
Davis Bacon. special insurance requirements, or limit to days and times erecting crews are permitted to work.
• Accessories not provided by Buck Steel (including but not limited to: windows, doors. cupolas. vents, fans, lighting, stucco, masonry etc.)
will not be installed by the erector unless otherwise specified.
• Anchor bolts are NOT included in this quote and are NOT provided by Buck Steel.
• Concrete is NOT included in this quote and is NOT provided by Buck Steel
• Buck Steel and/or the Building Engineer is NOT the "Engineer of Record'. The customer/owner is responsible for any "special building
inspector or "structural engineer required by the city or county for pre and post construction inspections.
• All prices are in USD.
• Sales tax is NOT included in this quote.
Questions about this quote?
Contact Brian Buck at
Florida Tennessee WebsIle
www.bucksteel.com
EFTA00798575