Document text
Leica TPS1200+
System
Field Manual
e
Version 6.0
English - when it has to be right ice
Geosystems
Introduction
Purchase
Lë
Product
identification
Symbols
Trademarks
Available
documentation
Congratulations on the purchase of a TPS1200+ series instrument.
To use the product in a permitted manner, please refer to the detailed safety direc-
tions in the User Manual.
The type and the serial number of your product are indicated on the type plate.
Enter the type and serial number in your manual and always refer to this information
when you need to contact your agency or Leica Geosystems authorized service
workshop.
Type:
Serial No.:
The symbols used in this manual have the following meanings:
Type Description
ca Important paragraphs which must be adhered to in practice as
they enable the product to be used in a technically correct and
efficient manner.
e CompactFlash and CF are trademarks of SanDisk Corporation
e Bluetooth is a registered trademark of Bluetooth SIG, Inc
All other trademarks are the property of their respective owners.
Refer to the following resources for all TPS1200+ documentation and software
e the SmartWorx DVD
e http:/Awww.leica-geosystems.com/downloads
TPS1200+ Introduction
Table of Contents
In this manual
Table of Contents
Chapter Page
1 User Interface 7
1.1 Keyboard 7
1.2 Screen 8
1.3 Operating Principles 9
1.4 Icons 10
1.5 Symbols 17
2 Configurable Keys 19
2.1 Hot Keys 19
2.2 USER Key 20
3 Quick Settings - SHIFT USER 21
4 Instrument Setup 23
4.1 Instrument Setup 23
4.2 Levelling Up with the Electronic Level 25
4.3 SmartStation Setup 26
4.4 Instrument Setup for Remote Control 28
5 Setup, Measure and Record 29
6 Manage... - Getting Started 31
7 Manage...\Jobs 35
7.1 Overview 35
7.2 Creating a New Job/Editing a Job 36
8 Manage...\Data 39
8.1 Overview 39
8.2 Point Management 40
8.2.1 Creating a New Point/Editing a Point 40
8.2.2 Mean Page 44
8.3 Line/Area Management 47
8.3.1 Overview 47
8.3.2 Creating a New Line/Area/Editing a Line/Area 48
8.4 Point Sorting and Filters 51
8.4.1 Sorting and Filters for Points, Lines and Areas 51
8.4.2 Point, Line and Area Code Filter 53
9 Manage...\Codelists 55
9.1 Creating a New Codelist/Editing a Codelist 55
9.2 Creating a New Code/Editing a Code 56
10 Linework 59
10.1 Performing Linework 59
10.2 Combining Linework and Coding 62
TPS1200+ 3
11
Manage...\Coordinate Systems
65
11.1 Overview
65
11.2 Creating a New Coordinate System/Editing a Coordinate System 66
11.3 Transformations/Ellipsoids/Projections
68
11.3.1 Accessing Transformation/Ellipsoid/Projection Management 68
11.3.2 ` Creating/Editing a Transformation/Ellipsoid/Projection 69
11.4 Geoid/CSCS Models 71
12 Manage...\Configuration Sets 73
12.1 Overview 73
12.2 Creating a New Configuration Set 74
12.3 Editing a Configuration Set 75
13 Manage...\Reflectors 77
13.1 Overview 77
13.2 Creating a New Reflector/Editing a Reflector 78
14 Convert...\Export Data from Job 79
14.1 Overview 79
14.2 Exporting ASCII Data 80
14.3 Exporting DXF Data 82
14.4 Exporting LandXML Data 83
15 Convert, Vmport Data to Job 85
15.1 Overview 85
15.2 Importing ASCII/GSI Data 86
15.3 Importing DXF Data 88
16 Convert...\Copy Points Between Jobs 89
17 Config...\Survey Settings... 91
17.1 ID Templates 91
17.1.1 Overview 91
17.1.2 | Creating a New ID Template/Editing an ID Template 92
17.2 Display Settings 93
17.3 Coding & Linework Settings 95
17.4 Offsets 97
18 Config...\instrument Settings... 99
18.1 EDM & ATR Settings 99
18.2 Search Windows 103
18.3 Automatic Prism Search 105
18.4 TPS Corrections 106
18.5 Compensator 109
18.6 Instrument ID 110
18.7 Telescope Accessories 111
19 Config...\General Settings... 113
19.1 Wizard Mode 113
19.2 Hot Keys & User Menu 114
19.3 Units & Formats 116
19.4 Language 119
19.5 Lights, Display, Beeps, Text 120
19.6 Start Up & Power Down 122
TPS1200+
Table of Contents
20 Interfaces, Ports, Devices 125
20.1 Interfaces 125
20.1.1 Overview of Interfaces 125
20.1.2 Configuring an Interface 126
20.2 Ports 127
20.3 Devices 128
20.3.1 Overview of Devices 128
20.3.2 Configuring a Device 129
20.3.3 Controlling a Device 130
20.3.4 Creating a New Device/Editing a Device 131
21 Config...\Interfaces... - Editing the Interface 133
21.1 GSI Output 133
21.2 GeoCOM Mode 134
21.3 RCS Mode 135
21.4 Export Job 136
21.5 GPS RTK 137
21.6 Internet 138
22 Config...\interfaces... - Controlling the Device 139
22.1 Digital Cellular Phones 139
22.2 Modems 142
22.3 Radios for GPS Real-Time 143
22.4 Radios for Remote Control 144
22.5 RS232 145
22.6 GPRS / Internet Devices 146
22.7 Internet 147
22.8 Creating a New Station to Dial/Editing a Station to Dial 149
22.9 Creating a New Server to Connect/Editing a Server to Connect 151
23 Config...\SmartStation... 153
23.1 Real-Time Mode 153
23.2 Point Occupation Settings 157
23.3 Satellite Settings 160
23.4 Local Time Zone 162
23.5 Quality Control Settings 163
23.6 Logging of Raw Obs 164
24 Tools... 165
24.1 Format Memory Device 165
24.2 Transfer Objects... 166
24.3 Upload System Files... 167
24.4 Calculator and File Viewer 169
24.5 Licence Keys 170
24.6 Field to Office 171
Table of Contents TPS1200+ 5
25 STATUS 173
25.1 STATUS: Station Information 173
25.2 STATUS: Battery & Memory 174
25.3 STATUS: System Information 175
25.4 STATUS: Interfaces... 177
25.5 STATUS: Bluetooth 178
25.6 STATUS: Level & Laser Plummet 179
25.7 STATUS SmartStation... 180
25.7.1 Satellite Status 180
25.7.2 Real-Time Status 182
25.7.3 Current Position 187
25.7.4 Logging Status 189
25.7.5 | SmartAntenna System Info 191
26 NTRIP via Internet 193
26.1 Overview 193
26.2 Configuring SmartStation for Using NTRIP Service 194
26.2.1 Configuring an Access to the Internet 194
26.2.2 Configuring to Connect to a Server 196
26.2.3 Using the NTRIP Service with SmartStation 198
27 Menu Tree 201
Index 203
TPS1200+
Table of Contents
1 User Interface
1.1 Keyboard
Keys Key
Hot keys F7-F12
Alphanumeric keys
Description
User definable keys to execute commands or access
chosen screens.
Refer to "2 Configurable Keys" for further details.
To type letters and numbers.
CE
ESC
USER
PROG (ON)
Clears all entry at the beginning of user input.
Clears the last character during user input.
Leaves the current menu or dialog without storing
changes made.
Calls the user defined menu.
Refer to "2 Configurable Keys" for further details.
If the instrument is off: to turn the instrument on.
If the instrument is on: to access the Programs menu.
ENTER
Selects the highlighted line and leads to the next logical
dialog/menu.
Starts the edit mode for edit fields.
Opens a list box.
SHIFT
Changes between the first and the second level of func-
tion keys.
Arrow keys
Function keys F1-F6
Move the focus on the screen.
Correspond to the six softkeys that appear on the bottom
of the screen when the screen is activated.
Key combinations Keys
PROG plus USER
SHIFT F12
Description
Turns the instrument off, when in TPS1200+ Main Menu.
Calls STATUS Level & Laser Plummet.
SHIFT F11
SHIFT USER
Calls CONFIGURE Lights, Display, Beeps, Text.
Calls QUICK SET Change Settings to.
Refer to "3 Quick Settings - SHIFT USER" for further details.
SHIFT A
SHIFT ei
User Interface
Pages up.
Pages down.
TPS1200+ 7
1.2 Screen
Screen f
a — ai | IR ; h Ri a) mnie
b —Tes1200 O55 I u c & b) Caption
c Hain Henu St — g c) Title
te H E IG) d) Screen area
1 Survey 2 Programs.. 3 Bauen: e) Message line
=h SÉ | f) Icons
<= $ Ti h o ESC
d Convert, 5 Config. 6 Tools. , h) CAPS
e — iat | : ;
cout] ft jt) SHIFT icon
j) Quick coding icon
TPS12_081 k) Softkeys
Elements of the Element Description
screen
Time The current local time is shown.
Caption Shows location either in Main Menu, under PROG key or
USER key.
Title Name of the screen is shown.
Screen area
The working area of the screen.
Message line
Icons
ESC
CAPS
Messages are shown for 10 s.
Shows the current status information of the instrument. Refer
to "1.4 Icons". Can be used with touch screen.
Can be used with touch screen. Same functionality as the fixed
key ESC. The last operation will be undone.
The caps mode for upper case letters is active. The caps mode
is activated and deactivated by pressing UPPER (F5) or
LOWER (F5) in some screens.
SHIFT icon
Shows the status of the SHIFT key; either first or second level
of softkeys is selected. Can be used with touch screen and has
the same functionality as the fixed key SHIFT.
Quick coding icon
Softkeys
Scroll bar
Shows the quick coding configuration. Can be used with touch
screen to turn quick coding on and off.
Commands can be executed using F1-F6 keys. The
commands assigned to the softkeys are screen dependent.
Can be used directly with touch screen.
Scrolls the screen area up and down.
TPS1200+ User Interface
1.3
Keyboard and
touch screen
Turn instrument on
Turn instrument off
step-by-step
Lock/Unlock
keyboard
User Interface
Operating Principles
The user interface is operated either by the keyboard or by the touch screen with
supplied stylus. The workflow is the same for keyboard and touch screen entry, the
only difference lies in the way information is selected and entered.
Operation by keyboard
Information is selected and entered using the keys. Refer to "1.1 Keyboard" for
further details of the keys on the keyboard and their function.
Operation by touch screen
Information is selected and entered on the screen using the supplied stylus.
Operation
To select an item
Description
Tap on the item.
To start the edit mode in input fields
Tap on the input field.
To highlight an item or parts of it for
editing
Drag the supplied stylus from the left to
the right.
To accept data entered into an input field
and exit the edit mode
Tap somewhere else on the screen
outside of the input field.
Press and hold PROG for 2 s.
Step |Description
Ce |The instrument can only be turned off in TPS1200+ Main Menu.
1. Press and hold both USER and PROG simultaneously.
2. Press YES (F6) to continue or NO (F4) to cancel.
Option | Description
Lock | To lock the keyboard press and hold SHIFT for 3 s. The message
‘Keyboard locked’ is momentariliy displayed on the Message Line.
Unlock | To unlock the keyboard press and hold SHIFT for 3 s. The message
‘Keyboard unlocked’ is momentariliy displayed on the Message Line.
TPS1200+
1.4 Icons
Description
Allocation of icons
ATR/LOCK/PS
10
The screen icons display the current status information of the instrument.
TPS specific and common icons
16:30 Ik $
TPS1200 I |
Hain Henu
1 Survey 3 Hanage..
St
AG A
4 Convert. 5 Confiq... E Tools..
iar j
[Eana EES) EI | |,
TPS12_172
GPS specific and common icons
abcdef gh i
l Lat 8 $
ð Leg
11:38
STATUIS
SmartStation
1 Satellite Status
2 Real-Time Status
3 Current Position
4 Logging Status
5 SmartAntenna System Info
SA Wi
D o
ix
war— j
EE EE Eeer
TPS12_172a
ee ee
SNr
ZIQ OO E o
za
<~
EE
SNr
ATR/LOCK/PS
Reflector
EDM
Compensator/face I&II
RCS
Bluetooth
Line/area
CompactFlash card/internal memory
Battery
SHIFT
Quick coding
GNSS Position status
Number of visible satellites
Contributing satellites
Real-time device and real-time
status, Internet online status
Position mode
Bluetooth
Line/area
CompactFlash card/internal memory
Battery
SHIFT
Quick coding
e The currently active ATR/LOCK/PS settings or prism searches are displayed.
e Touch screen: Tapping the icon leads to QUICK SET Change Settings to.
Description
ATR active.
Low Visability mode is active.
LOCK active.
LOCK active.
P|) deeg
Prism being followed.
Short Range mode is active.
TPS1200+
User Interface
Description
LOCK active. Prism lost.
Instrument locks onto reflector if in field of view.
ATR Searching.
PowerSearch window.
PowerSearch active.
Prediction.
Reflector e The currently active reflector is displayed.
e Touch screen: Tapping the icon leads to MANAGE Reflectors.
Icon
Description
Leica Circ Prism.
Leica 360 ° Prism.
Leica Mini Prism.
Leica Mini 0.
+4 sët bi Je
Leica Mini 360 °.
EJ
at
its,
oe
Leica HDS Target.
Leica ReflTape.
i.
=
LI
Ch
=
Reflectorless.
User defined prism.
EDM e The currently active EDM measurement settings are displayed.
e Touch screen: Tapping the icon leads to CONFIGURE EDM & ATR Settings.
User Interface
TPS1200+ 11
Icon Description
IR IR EDM type: Reflector IR, possible modes are:
STO FAST e STD - Standard.
e FAST - Fast.
IR IR e TRK - Tracking.
TRK AG e AVG - Averaging.
IR e SYNC - SynchroTrack
SYNE
RI Red laser is turned on.
STD
RL RL EDM type: Reflectorless RL, possible modes are:
STD TRK e STD- DOAN
e TRK - Tracking.
RL e AVG - Averaging.
ANG
Lo Lo EDM type: Long Range LO, possible modes are:
STD Au e STD- SES
e AVG - Averaging.
TR: Auto points are being recorded by time.
TRE
IR- Auto points are being recorded by distance or height.
TAK
T Ra Auto points are being recorded by stop & go.
TRE
Compensator e Compensator off or face I&II icon is displayed.
lface I&II e Touch screen: Tapping the icon leads to CONFIGURE Compensator.
Icon Description
e , Compensator is turned off.
t Compensator is turned on, but is out of range.
The current face of the instrument is shown, if the compensator
and the Hz-correction are turned on.
12
TPS1200+ User Interface
RCS
Bluetooth
Line/area
CompactFlash
card/internal
memory
User Interface
e RCS settings are displayed.
e Touch screen: Tapping the icon leads to CONFIGURE Interfaces.
Icon Description
The RCS is turned on.
The RCS is turned on and is receiving messages.
e The status of the Bluetooth port and any Bluetooth connection is displayed.
e Touch screen: Tapping the icon leads to STATUS Bluetooth.
Icon Description
$ The Instrument is Bluetooth capable.
(The instrument must have a Communication side cover)
$ The Bluetooth connection on Port 3 is established and is ready
` to be used.
E; A The Bluetooth connection on Port 3 is established, active and
5 is communicating data.
e The number of lines and areas currently open in the active job is displayed.
e Touch screen: Tapping the icon leads to MANAGE Data: Job Name.
Icon Description
od The number of lines and areas which are currently open in the
eo 0 active job is shown.
e The status of the CompactFlash card and internal memory are displayed.
e For the CompactFlash card, the capacity of used space is shown in seven levels.
e For the internal memory, the capacity of used memory is shown in nine levels.
e Touch screen: Tapping the icon leads to STATUS Battery & Memory.
Description
The CompactFlash card is inserted and can be removed.
AN
The CompactFlash card is inserted and cannot be removed.
It is strongly recommended not to remove the CompactFlash
card to avoid loss of data.
£) Me Ore
e The internal memory is the active memory device.
No icon The CompactFlash card is the active memory device. No
CompactFlash card is inserted.
TPS1200+ 13
Battery e The status and source of the battery is displayed. If an external battery is
connected and an internal battery is inserted, then the internal battery is used.
e Touch screen: Tapping the icon leads to STATUS Battery & Memory.
Icon
Description
A TPS internal battery is inserted and in use.
A TPS external battery is connected and in use.
RCS and internal TPS batteries are in use.
= on E
RCS and external TPS batteries are in use.
SHIFT e The status of the SHIFT key is displayed.
e Touch screen: Tapping the icon shows additional softkeys.
Description
Additional softkeys are available in the currently visible screen.
The SHIFT key has been pressed.
Quick coding e The quick coding is displayed. Visible during Survey and other application
programs where it is possible to measure a point with quick codes.
e Touch screen: Tapping the icon turns the quick coding on or off.
Icon
UI
01
Description
Quick coding is turned on. Quick codes with one digit are used
from the active codelist.
Quick coding for quick codes with one digit is turned off.
02
Quick coding is turned on. Quick codes with two digits are used
from the active codelist.
02
03
03
Quick coding for quick codes with two digits is turned off.
Quick coding is turned on. Quick codes with three digits are
used from the active codelist.
Quick coding for quick codes with three digits is turned off.
14
TPS1200+ User Interface
GPS Position
status
Number of visible
satellites
Contributing
satellites
User Interface
e Displays the status of the current position.
e Touch screen: Tapping the icon leads to STATUS Position.
Icon Description
No icon No position available
Autonomous solution available.
Code solution available.
Phase fixed solution available. The ticks indicate that an ambi-
guity check is being made.
e Displays the number of theoretically visible satellites above the configured cut
off angle according to the current almanac.
e Touch screen: Tapping the icon leads to STATUS Satellites.
Icon Description
WK The number of visible satellites.
S
e Displays the number of satellites that are contributing to the currently computed
position solution.
e Touch screen: Tapping the icon leads to STATUS Satellites.
Icon Description
fies Gë When a position status icon is displayed, the number of satel-
H8 Be? lites currently used for the position computation are shown.
If no position is currently available but satellites are being
tracked then the L1 and L2 values (GPS only) or the G and R
values (GPS & GLONASS) show how many satellites are
being tracked.
Ce The number of contributing satellites can differ from
the number of visible satellites. This may be either
because satellites cannot be viewed or the
observations to these satellites are considered to be
too noisy to be used in the position solution.
SÉ Ce The number of contributing GLONASS satellites
R= 0 could be zero if five or more GPS satellites are used
for the position computation. The processing algo-
rithm automatically selects the best possible set of
satellite combinations for the position computation.
A position computation with R = 0 is certainly within
the specified reliability.
TPS1200+ 15
Real-time device e Displays the real-time device configured to be used and its status.
and e Touch screen: Tapping the icon leads to STATUS Real-Time Input.
Real-time status e Real-time mode: Rover - An arrow pointing down indicates a rover configuration.
The arrow flashes when real-time messages are received.
Icon Description
Digital cellular phone connecting
Digital cellular phone receiving
H
(o SC
B B
Kë KA) Radio receiving
Wa why, RS232 receiving
Oe Be
KG Wi, Bluetooth enabled device attached and receiving. A digital
wt "H cellular phone is shown as an example.
DEE Icon Description
status
SmartStation is online in the Internet.
E
Position mode e Displays the current position mode depending on the configuration defined. As
soon as this icon becomes visible SmartStation is in a stage where practical
operation can commence.
e Touch screen: Tapping the icon leads to STATUS Logging.
Icon Position mode | Point occupation | Raw data logging
Af Static Yes No
ay Static Yes Yes
Lë
Moving No No
Al
16 TPS1200+ User Interface
1.5 Symbols
Description
Filter
Attributes
Limits
Largest residual
Staked out
User Interface
The symbols provide information regarding settings.
Name to indicate points which have been staked
out. The staked out flag can be reset in MANAGE
Stakeout Filter.
Symbol Description Example
Y The filter symbol is shown on the Points, Lines,
Area or Map page if a point, line or area filter iS | Points sl?
active.
Symbol Description Example
: The attribute symbol is displayed in MANAGE
Codes to indicate codes that have attributes e g
attached. pe E
Symbol Description Example
Y Indicates a defined limit has been exceeded. For
example, the exceeding of a residual limit in the 0.054%
Determine Coordinate System application -0.005
program.
Symbol Description Example
H This symbol is used to indicate the largest
residual in DET C SYS Step 4: Check Resid- -0.069%
uals.
Symbol Description Example
Ps This symbol is used in MANAGE Data: Job
1233
E
TPS1200+
17
18
TPS1200+
User Interface
2 Configurable Keys
2.1 Hot Keys
Description
Functionality
Access
Defining hot keys
Configurable Keys
Two levels of hot keys exist:
e The first level are the keys F7, F8, ..., F12
e The second level is the combination of SHIFT and F7, F8, ..., F12
Hot keys provide a shortcut for quickly and directly carrying out functions or
starting application programs assigned to the keys. The assignment of functions
and application programs to hot keys is user configurable.
The first level is accessed by pressing F7, F8, ..., F12 directly.
The second level is accessed by pressing SHIFT first followed by F7, F8, ..., F12
Hot keys can be pressed at any time. It is possible that a function or application
program assigned to a hot key cannot be executed in certain situations.
Refer to "19.2 Hot Keys & User Menu" for further details.
TPS1200+ 19
2.2 USER Key
Description
Functionality
Access
Defining USER key
TPS1200+
User Menu:
configuration set
20
e The USER key opens the user defined menu.
e The user defined menu can be configured to contain the most used functions
and/or the most used application programs.
e Selecting an option in the user defined menu carries out the function or starts the
application program assigned to the option.
e Press USER to access TPS1200+ User Menu: configuration set.
e This menu cannot be accessed when a CONFIGURE screen is open.
e Refer to "19.2 Hot Keys & User Menu" for further details.
e This is an example of what a user defined menu can look like. The softkeys and
their order is fixed. The functions and application programs which are assigned
to the individual places in the user defined menu can differ depending on the
configuration.
e The user defined menu is stored with the currently active configuration set.
17:14 IR ZS &
TPS 1200 + STD I N Bo 8
User Menu: configure set X|
Job Hanaqement
Export Data from Job
Hot Keys & User Nenu To configure the user menu.
uzat STAT (F3)
CONT | CONF | STAT | | | | To access the Status Menu.
2 Data Management
2 TPS Corrections
4 EDH & ATR Settings
5 Check Recorded PtfBacksight Pt CONT (F1)
6 EDH Test Signal/Frequency To execute the selected function.
t Import Data to Job CONF (F2)
5
g
TPS1200+ Configurable Keys
Quick Settings - SHIFT USER
Description
Access
QUICK SET
Change Settings
To
This screen displays the possible settings to change to. All possible settings have
two states and allow very quick setting changes. Highlight a field and press ENTER
to change to the displayed setting or press the number next to the function.
Press SHIFT USER.
12:38 teary A LR) COMPS (F1)
QUICK SET STD N SoG To turn the instrument using
Change Settings to:
1 ATR » Turn ON compass readings.
2 LOCK + Turn OFF Hz/V (F2)
3 EDH Type = Change to RL To turn the instrument to a specific
4 EDH Hode + Change to TRK entered position.
5 ROS Hode + Turn OFF
6 PS Window + Turn ON JSTCK (F3) |
7 V¥-Angle + Running To turn the instrument using the
8 Change Face arrow keys.
mzar CHKPT (F4)
COMPS| Hz/¥|JSTCK|CHKPT| L.GO| PS | To check a point or the instrument
orientation.
L.GO (F5) or L.INT (F5)
L.GO (F5) to start an ATR search, to
set <Automation: LOCK> and to
lock onto the reflector.
L.INT (F5) to interrupt LOCK.
PS (F6)
Starts a prism search with Power-
Search.
Description of fields
Field Option Description
ATR > Turn ON To activate ATR, <Automation: ATR>.
> Turn OFF To deactivate ATR, <Automation: None>.
LOCK > Turn ON To activate LOCK, <Automation: LOCK>.
> Turn OFF To deactivate LOCK, <Automation: None>.
EDM Type > Change to IR To activate measurements to reflectors,
<EDM Type: Reflector (IR)>.
> Change to RL | To activate reflectorless measurements,
<EDM Type: Reflictrless (RL)>. Deactivates
ATR and LOCK, <Automation: None>.
EDM Mode |> Change to TRK | To activate tracking with continuous meas-
urements, <EDM Mode: Tracking>.
> Change to STD | To activate single measurements, EDM
Mode: Standard>.
Quick Settings - SHIFT USER TPS1200+ 21
22
Field
Option
Description
RCS Mode
PS Window
> Turn ON
> Turn OFF
> Turn ON
> Turn OFF
To activate RCS mode and LOCK, <Use
Interface: Yes> in CONFIGURE RCS Mode,
<Automation: LOCK>.
To deactive RCS mode, <Use Interface: No>
in CONFIGURE RCS Mode.
To activate the PowerSearch window, <PS
Window: On>. Prisms are searched for with
PowerSearch in the PS window when PS (F6)
is pressed.
Ce _ If <PS Window: On> is selected
and reflectorless measurements Is
still set, <EDM Type: Reflctrless
(RL)>, then this is changed to
measurements to reflectors, <EDM
Type: Reflector (IR)>.
To deactivate the PowerSearch window <PS
Window: Off>. A 360° search is performed
when PS (F6) is pressed.
V-Angle
> Hold
> Running
The displayed value for the vertical angle is
held after DIST (F2) and until REC (F3) is
pressed, <V-Angle: Hold after DIST>.
The displayed value for the vertical angle is
updated after DIST (F2) is pressed, <V-
Angle: Running>.
Ce Be aware that after restarting the
instrument this setting remains and
is not changed.
Change
Face
no choices
To change the face of the telescope.
Next step
Highlight the desired item and press ENTER.
OR
Press the desired softkey.
TPS1200+
Quick Settings - SHIFT USER
4 Instrument Setup
4.1 Instrument Setup
Description This topic describes an instrument setup over a marked ground point using the laser
plummet. It is always possible to set up the instrument without the need for a marked
ground point.
Ce Important features:
e It is always recommended to shield the instrument from direct sunlight and
avoid uneven temperatures around the instrument.
The laser plummet described in this topic is built into the vertical axis of the
instrument. It projects a red spot onto the ground, making it appreciably easier
to centre the instrument.
The laser plummet cannot be used in conjunction with a tribrach equipped
with an optical plummet.
Refer to "TPS1200+ Technical Reference Manual" for additional information
on using the laser plummet.
Setup step-by-step KI
TPS12_019
Step
Lë
Description
Shield the instrument from direct sunlight and avoid uneven temperatures
around the instrument.
Extend the tripod legs to allow for a comfortable working posture. Position
the tripod over the marked ground point, centring it as well as possible.
Fasten the tribrach and instrument onto the tripod.
Turn on the instrument by pressing PROG for 2 s. Press SHIFT (F12) to
access STATUS Level & Laser Plummet, activating the laser plummet.
Move the tripod legs (1) and use the tribrach footscrews (6) to centre the
plummet (4) over the ground point.
Adjust the tripod legs to level the circular level (7).
By using the electronic level turn the tribrach footscrews (6) to precisely
level the instrument.
Instrument Setup
TPS1200+ 23
24
Step |Description
7. Centre the instrument precisely over the ground point (4) by shifting the
tribrach on the tripod plate (2).
8. Repeat steps 6. and 7. until the required accuracy is achieved.
TPS1200+ Instrument Setup
4.2 Levelling Up with the Electronic Level
Description
Access
Levelling the
instrument with the
electronic level
step-by-step
Instrument Setup
The STATUS Level & Laser Plummet screen can be used to precisely level up the
instrument with the electronic level using the foot screws of the tribrach. The longi-
tudinal and transverse tilt of the instruments vertical axis is graphically and numeri-
cally displayed.
Press SHIFT F12.
Step |Description
1. STATUS Level & Laser Plummet
Use the foot screws to move the electronic level to the centre.
Ce |The level moves linear with the inclination values <Tilt L:> and <Tilt T:>.
On the screen closest to the circular level, the electronic level moves down
if the value in <Tilt L:> gets bigger and vice versa. If the value for <Tilt T:>
gets bigger the level moves left and vice versa.
Ce |The electronic level never disappears even if the instrument is not level.
2. When the electronic level is centred, the instrument has been perfectly
levelled up.
3: CONT (F1) to exit STATUS Level & Laser Plummet.
For instruments with two displays:
e The display closer to the circular level shows the movement of the electronic
level in the same direction as the movement of the circular level.
e The other display shows the movement of the electronic level in the opposite
direction of the circular level movement.
TPS1200+ 25
4.3 SmartStation Setup
Setup step-by-step
26
Step
Description
Refer to "4.1 Instrument Setup” for the initial instrument setup onto a
tripod. Remove the instrument carry handle by simultaneously pressing
and holding-in the four push buttons.
TPS12_194
Step |Description
1. A circular screw is located at one end of the clip-on-housing. Ensure that
the circular screw is in the unlocked position. Turn it anticlockwise, as
shown by the lock and arrow symbols on the screw.
2. Slide the clip-on-housing into position underneath the SmartAntenna
Adapter, such that the guide rails on the clip-on-housing and the guide
rails on the SmartAntenna Adapter are aligned.
Ce | Ensure that the connector located at the end of the clip-on-housing fits into
its port of the SmartAntenna Adapter.
3. Lock the circular screw by turning it clockwise, as shown by the lock and
arrow symbols on the screw. The clip-on-housing is now locked into posi-
tion.
4. Thread the antenna onto the clip-on-housing.
TPS12_195
TPS1200+ Instrument Setup
Step |Description
5. Place the SmartAntenna Adapter with attached clip-on-housing onto the
instrument by simultaneously pressing and holding-in the four push
buttons.
Ce" /|Ensure that the interface connection on the underside of the Smart-
Antenna Adapter is on the same side as the Communication side cover.
TPS12_209
Step |Description
6. Place the SmartAntenna onto the SmartAntenna Adapter by simultane-
ously pressing and holding-in the two press clips.
Ce | Ensure that the clip-on-contacts on the underside of the SmartAntenna
are aligned to the clip-on-contacts of the SmartAntenna Adapter.
Instrument Setup TPS1200+ 27
4.4 Instrument Setup for Remote Control
Setup step-by-step
TPS12_196
Step |Description
Ce | Refer to "4.1 Instrument Setup" for the initial instrument setup onto a
tripod. Remove the instrument carry handle by simultaneously pressing
and holding-in the four push buttons.
1. Place the RadioHandle onto the instrument by simultaneously pressing
and holding-in the four push buttons.
Ce | Ensure that the interface connection on the underside of the RadioHandle
is on the same side as the Communication side cover.
2. Swing the RadioHandle antenna into an upright position.
Ce | Refer to "RX1200 User Manual" for further details.
28 TPS1200+ Instrument Setup
5 Setup, Measure and Record
Description e The Setup application program is used to define the job settings and to set up
and orient the instrument. The routine is accessible from each application
program.
e Independent of the chosen Setup application program method, the job settings
can be defined in the Begin screen of any application program by moving the
focus to <Job:> and pressing ENTER.
Setup step-by-step The quickest setup method is described. Refer to "TPS1200+ Applications Field
Manual" for further details on additional setup methods.
Step |Description
1. PROG highlight Setup and ENTER to access SETUP Station Setup
Begin.
CONT (F1) to access SETUP Station Setup.
SETUP Station Setup
Select the job which contains the fixpoints. <Fixpoint Job:>.
Select the setup method. <Method: Set Azimuth:>.
4. Select the source for the station coordinates. For <Station Coord: From
Job> and <Station Coord: Frm Fixpoint Job> CONT (F1) to access
SETUP Select Station.
5. Type in <Station ID:> and <Instrument Ht:>
CONT (F1) to access SETUP Set Stn & Ori - Set Azimuth.
6. Aim at the target point and enter the Azimuth and Backsight ID. A distance
to the target point may also be measured.
Enter the height of the target point.
8. Decide whether all angle measurements at the station are to be updated.
Ce | Az=0 (F4) to set the azimuth to 0.000.
9. SET (F1) to set station and orientation.
Measure and The SURVEY Survey: Job Name screen can be accessed from many application
record programs where point measurement is required. The ALL (F1), DIST (F2) and REC
step-by-step (F3) keys are used for measuring and storing the point data. The measurement
settings depend on the current configuration set.
Step
1.
Description
Refer to paragraph "Setup step-by-step" for information on how to set up
the instrument.
Select Main Menu: Survey.
SURVEY Survey Begin
CONT (F1) to access SURVEY Survey: Job Name, Survey page.
Setup, Measure and Record
TPS1200+ 29
Combining DIST
(F2) and REC (F3)
step-by-step
30
Step
Description
DIST (F2) to measure a distance and to display the distance and the
angles. The update of the vertical angle after DIST (F2) depends on the
setting of <V-Angle:> in CONFIGURE Units & Formats, Angle page.
e For <V-Angle: Hold after Dist> the vertical angle remains fixed until
REC (F3) is pressed.
e For <V-Angle: Running> the vertical angle is continuously updated
according to the telescope movement.
REC (F3) to store either the displayed distance if measured with DIST (F2)
and angles or angles and no distance. The displayed point ID is increased
according to the active point ID template. After REC (F3) is pressed, the
distance related values are cleared.
ALL (F1) to measure and store distance and angles. The displayed point
ID is increased according to the active point ID template. After ALL (F1)
is pressed, the distance related values are cleared. Pressing ALL (F1)
works in the same way as pressing DIST (F2) and then REC (F3).
ALL (F1) to measure distance and angles.
The key combination of DIST (F2) and REC (F3) can be used to measure non acces-
sible points with the reflector, for example building corners.
TPS12_039
Step
1.
TPS12_040
Description
Position the reflector at the same distance from the instrument as the
building corner to be measured.
DIST (F2) to measure the distance.
REC (F3) to store the measured distance to the reflector and the angles
to the corner of the house.
For measurements without reflector <EDM Type: Refictrless (RL)> must be set.
For <EDM Mode: Tracking>, continuous distance measurements are executed
once ALL (F1) or DIST (F2) is pressed.
TPS1200+ Setup, Measure and Record
Manage... - Getting Started
Accessing
MANAGE XX
step-by-step
MANAGE
XX
Step |Description
1. Select Main Menu: Manage....
2. TPS1200+ Management
Select an option in the menu.
3: CONT (F1) to access MANAGE XX.
Ce" |MANAGE XX can be accessed directly from a choicelist in some screens,
for example from the begin screen from an application program.
e MANAGE Jobs (Device) is shown as an example. Additional softkeys are avail-
able on other screens. The listed options are stored in the database DB-X. Any
unavailable information is shown as -----
e The screen for MANAGE Data: Job Name consists of several pages. The
objects listed and their order depend on the active sort and filter settings. An
active filter for a page is indicated by Y shown to the right of the name of the
page. On the Lines (X) page and the Areas (X) page, the number in brackets
next to the name of the page indicate the number of open lines/areas. Example:
Lines (2)/Areas (2) means that two lines are open.
SST a) CONT FA)
MANAGE STD x To select an option and to return to
ss the previous screen. For MANAGE
Codelists, the codes from the high-
lighted codelist are copied to the
active job.
NEW (F2)
To create an option. After storing a
new line/area, all existing lines and
areas which are open are closed.
CONT | NEW | EDIT | DEL | DATA | a? EDIT (F3)
To edit the option. For MANAGE
Configuration Sets, the first screen
of the sequential configuration set
wizard for the highlighted configura-
tion set is accessed.
DEL (F4)
To delete the option. Available unless
MANAGE Data: Job Name, Lines
(X) page and MANAGE Data: Job
Name, Areas (X) page.
DATA (F5)
To view, edit and delete points, lines
and areas stored with the job. Points,
lines and areas are shown on sepa-
rate pages. Selected sort and filter
settings apply.
17.07.06
26.10.06
26.10.06
Default
active job
Manage... - Getting Started TPS1200+ 31
CLOSE (F4) and OPEN (F4)
To change between the options in the
Open column for the highlighted
line/area. The options are:
Yes: The line/areais open. Measured
points are assigned to the line/area.
No: The line/area is closed. Meas-
ured points are not assigned to the
line/area.
MORE (F5)
To display more information in the
second column. Available unless
MANAGE Jobs (Device).
PAGE (F6)
To change to another page on this
screen. Available for MANAGE Data:
Job Name.
CFCRD (F6) or INTL (F6)
To change between viewing jobs
stored on the CompactFlash card or
internal memory. Available for
MANAGE Jobs. Available for instru-
ments with internal memory.
SHIFT LOG (F4)
To view points, lines, areas and free
codes stored with the job sorted by
time. Available for MANAGE Data:
Job Name, Points page.
SHIFT DEL (F4)
To delete the line/area. Available for
MANAGE Data: Job Name, Lines
(X) page and MANAGE Data: Job
Name, Areas (X) page.
SHIFT SET-D (F4)
To turn the highlighted coordinate
system/configuration set into a user
defined default coordinate
system/configuration set stored in the
instrument. Available for MANAGE
Coordinate Systems and MANAGE
Configuration Sets. Available
unless a default coordinate
system/configuration set is high-
lighted.
SHIFT FILT (F5)
To define sort and filter settings.
Available for MANAGE Data: Job
Name.
TPS1200+ Manage... - Getting Started
Next step
IF an option
SHIFT DEFLT (F5)
To recall the deleted default coordi-
nate systems/configuration sets and
to reset default configuration sets to
the default settings. Available for
MANAGE Coordinate Systems and
MANAGE Configuration Sets.
THEN
is to be selected
is to be created or
edited
Manage... - Getting Started
highlight the desired option. CONT (F1) closes the screen and
returns to the screen from where MANAGE XX was
accessed.
highlight the option and NEW (F2)/EDIT (F3). Refer to the
individual chapters.
TPS1200+ 33
34
TPS1200+
Manage... - Getting Started
Manage...\Jobs
7.1 Overview
Description Jobs:
structure surveying projects.
contain all points, lines, areas and codes that are recorded and stored.
can be downloaded to LGO for post-processing or for data transfer to a further
program.
can be uploaded from LGO, for example for stakeout operations.
may be stored on the CompactFlash card or internal memory, if fitted.
Ce" When a job becomes active, then the sort and filter settings of this job are saved in
the SystemRAM. If the CompactFlash card is formatted then these last used sort and
filter settings are used for the job Default.
Manage...\Jobs
TPS1200+ 35
7.2 Creating a New Job/Editing a Job
Access
step-by-step
Lë
MANAGE
XX Job,
General page
36
1. Refer to "6 Manage... - Getting Started" to access MANAGE Jobs
(Device).
2. In MANAGE Jobs (Device) highlight a job. When creating a new job, the
3. NEW (F2)/EDIT (F3) to access MANAGE New Job/MANAGE Edit Job.
Step |Description
settings, including sort and filter settings, of this job are applied to the new
job, the codelist must be selected.
Editing jobs is similar to creating a new job. For simplicity, the screens are called
MANAGE XX Job and differences are clearly outlined.
Cie: Lei I, ian cé RI STORE (F1)
MANAGE STD To store the settings and to return to
MANAGE Jobs (Device).
Panera Rodelist |r
Name : new job DATA (F5)
Description :-_ rs Available for editing a job. To view,
ee edit and delete points, lines and
Creator sce areas stored with the job. Points,
hevics CF Card dé lines and areas are shown on sepa-
rate pages. Selected sort and filter
DECK settings apply.
STORE| | | | | PAGE | SHIFT LOG (F5)
Available for editing a job. To view,
edit and delete points, lines and
areas stored with the job. Points,
lines and areas are sorted by time in
one list.
Description of fields
Field Option Description
<Name:> User input A unique name for the new job. The name
may be up to 16 characters long and may
include spaces. Input required.
<Description:> User input Two lines for a detailed description of the
job. This can be for example, work to be
performed or the classes contained in the
job. Input optional.
<Creator:> User input The person’s name who is
creating/editing the job. Input optional.
<Device:> The device on which the job will be
stored.
Choicelist For instruments with internal memory.
Output For instruments without internal memory
and when editing a job.
TPS1200+ Manage...\Jobs
MANAGE
XX Job,
Codelist page
Manage...\Jobs
Next step
PAGE (F6) changes to the Codelist page.
15:09 IR £ ™ we H
MANAGE + STD I K aac
Edit Job: fixpoint job
heneral (rode) ist [Enard “ystem [avge]
Codelist codelist STORE (F1)
To store the settings and to return to
MANAGE Jobs (Device).
IMPRT (F2)
Available for editing a job. To add
additional codes from a new codelist
DECK to the job. The name of this codelist is
STORE| IHPRT| | CODES| DATA | PAGE | copied to the job.
CODES (F4)
Available for editing a job. To view,
edit, delete, sort and group codes
currently stored in the job. The func-
tionality of this screen is mainly the
same as for MANAGE Codes.
DATA (F5)
To view, edit and delete points, lines
and areas stored with the job. Points,
lines and areas are shown on sepa-
rate pages. Selected sort and filter
settings apply.
SHIFT EXPRT (F2)
Available for editing a job. To copy
codes from the job to an existing or
new codelist.
Description of fields
Field Option Description
<Codelist:> Choicelist Available for creating a new job or for
editing a job if no codes are stored in the
job. Choosing a codelist copies the codes
to the job.
Output Available for editing a job if codes are
stored in the job. If codes had been
copied from a System RAM codelist, then
the name of the codelist is displayed. If
codes have not been copied from a
System RAM codelist but typed in manu-
ally, then the name of the active job is
displayed.
Next step
PAGE (F6) changes to the Coord System page.
TPS1200+ 37
MANAGE
XX Job
Coord System
page
MANAGE
XX Job
Avge page
38
Choosing a coordinate system attaches it to the job. All other fields on this screen
are output fields. They depend on the transformation type of the selected coordinate
system.
Next step
PAGE (F6) changes to the Avge page.
In order to check measurements, the same point can be measured more than once.
If activated, an average or an absolute difference is calculated. Refer to paragraph
"MANAGE XX Job, General page" for information on the softkeys.
Description of fields
Absolute Diffs
Field Option Description
<Averaging Mode:> Defines the averaging principles for
multiple measured points.
Average Computes the average for the position
and the height. Points exceeding the
defined limits are marked with ? in
MANAGE Edit Point, Mean page.
Computes the absolute differences
between two points selected from a list of
measured points which are all stored with
the same point ID.
<Cartesian Z:>
Off Averaging is turned off.
<Method:> Available for <Averaging Mode:
Average>. The method used for
computing the average.
Weighted Computes a weighted average.
No Weighting |Computes an arithmetic average.
<Points to Use:> Choicelist The type of points which will be taken into
account for averaging or for absolute
differences.
<Avge Limit Pos:> | User input Available for <Averaging Mode:
and Average>. The acceptable difference for
<Avge Limit Ht:> the position and height components.
From User input Available for <Averaging Mode: Abso-
<Easting:> lute Diffs>. The acceptable absolute
to differences for each coordinate compo-
nent.
Next step
STORE (F1) stores the job and returns to MANAGE Jobs (Device).
TPS1200+
Manage...\Jobs
Manage...\Data
8.1 Overview
Description e Data is a generic term for points, lines and areas.
e Data management is the administration of data stored in the active job, including
e viewing data with their related information.
e editing data.
e creating new data.
e deleting existing data.
e filtering existing data.
Objects Objects:
e are points, lines and areas.
e have a unique identification ID. This is the point ID, the line ID and the area ID.
e mayor may not have a code attached. This is a point code for a point, a line code
for a line and an area code for an area.
Manage...\Data TPS1200+ 39
8.2 Point Management
8.2.1 Creating a New Point/Editing a Point
Access
step-by-step
MANAGE
XX Point,
Coords page
40
Step |Description
1. Refer to "6 Manage... - Getting Started" to access MANAGE Data: Job
Name, Points page
2 MANAGE Data: Job Name, Points page
If a point is to be edited, then highlight the point.
3. NEW (F2)/EDIT (F3) to access MANAGE New Point/MANAGE Edit
Point: Point ID.
Editing points is similar to creating a new point. For simplicity, the screens are called
MANAGE XX Point and differences are clearly outlined. If editing a point, then the
visible pages and softkeys on this screen depend on the properties of the point being
edited.
46:12 IR == WAL] STORE (F1)
MANAGE +@ >I g soe To store the point and all associated
Ge SU information and to return to
onrdes [Code] i
Point ID i 0001 MANAGE Data: Job Name, Points
page.
Easting : 7644356.044 m COORD (F2) ;
Northing - 253216.636 m To view other coordinate types.
Height | SOT) «| NORTH (F3) or SOUTH (F3)
Available for local geodetic or
uzat WGS 1984 geodetic coordinates
STORE| COORD| | |__| PAGE| when <Local Lat:> or <WGS 1984
Lat:> is highlighted. To change
between North and South latitude.
EAST (F3) or WEST (F3)
Available for local geodetic or
WGS 1984 geodetic coordinates
when <Local Long:> or <WGS 1984
Long:> is highlighted. To change
between East and West longitude.
SHIFT ELL H (F2) or SHIFT ORTH (F2)
Available for local coordinates. To
change between the ellipsoidal and
the orthometric height.
SHIFT INDIV (F5) or SHIFT RUN (F5)
To change between entering an indi-
vidual point ID different to the defined
ID template and the running point ID
according to the ID template.
TPS1200+ Manage...\Data
MANAGE
Description of fields
Field Option Description
<Point ID:> User input The name of the new point. The config-
ured point ID template is used. The ID can
be changed.
e To start a new sequence of point ID’s
overtype the point ID.
e Foran individual point ID independent
of the ID template SHIFT INDIV (F5).
SHIFT RUN (F5) changes back to the
next free ID from the configured ID
template.
If editing a point, then changing the point
ID for a point of any class applies this new
point ID to all other points with the same
original name, regardless of class.
Output Points of <Class: REF> cannot be
renamed.
Coordinates User input Negative geodetic coordinates are inter-
preted as being of the opposite hemi-
sphere or other side of the central
meridian. For example, entering -25 °N
will be stored as 25 °S, entering -33 "E will
be stored as 33 °W.
Output If editing, then points of <Class: REF>
cannot be renamed.
Next step
PAGE (F6) changes to the next page. Refer to the relevant paragraph below.
For GNSS points
Edit Point: Point ID, The name of the real-time reference station from where the GNSS point was meas-
Obs page
Manage...\Data
ured, the name of antenna used to measure the point and the baseline values are
shown in output fields.
For TPS points
It is possible to edit the reflector height. Changing the reflector height recalculates
the point height. The name of the station from where the point was measured is
shown in an output field. The distance variables AHz, AV, ASlop Dist are shown in
an output field, whenever a measurement has been taken in both faces.
Next step
PAGE (F6) changes to the next page. Refer to the relevant paragraph below.
TPS1200+ 41
MANAGE
XX Point,
Code page
42
The setting for <Thematc Codes:> in CONFIGURE Coding Settings determines
the availability of the subsequent fields and softkeys. For <Thematc Codes:
Without Codelist> none of the keys is available except for STORE (F1).
15:14 Lei I n d oe
MANAGE STD
Point Code : V STORE (F1)
Code Dese = gum tree To store the point and all associated
information and to return to
aian i É er MANAGE Data: Job Name, Points
page.
NEW-A (F2)
uzat To create additional attributes for the
STORE| NEW- A| | LAST |DEFLT| PAGE | point code.
NAME (F3) or VALUE (F3)
Available for attributes for which an
attribute name can be typed in.
To highlight <Attribute n:> or the
field for the attribute value. The name
of <Attribute n:> can be edited and
an attribute value can be typed in.
LAST (F4)
To recall the last used attribute
values which were stored with this
point code.
DEFLT (F5)
To recall the default attribute values
for the selected code.
Description of fields
Field Option Description
<Point Code:> Choicelist Available for <Thematc Codes: With
Codelist>. All point codes of the job
codelist can be selected. The description
of the code is shown as an output field.
The attributes are shown as output, input
or choicelist fields depending on their
definition.
<Code:> User input Available for <Thematc Codes: Without
Codelist>. The code to be stored with the
point. A check is performed to see if a
point code of this name already exists in
the job. If so, the according attributes are
shown.
<Attribute n:> User input Available for <Thematc Codes: Without
Codelist>. Up to eight attribute values
are available.
TPS1200+ Manage...\Data
MANAGE
Edit Point: Point ID,
Annots page
Manage...\Data
Next step
IF THEN
creating a point STORE (F1) stores the point and all associated information
and returns to MANAGE Data: Job Name, Points page.
editing a point e PAGE (F6) changes to the Annots page, if available.
e PAGE (F6) changes to the Mean page, if available. Refer
to "8.2.2 Mean Page" for information on softkeys and
fields on the Mean page.
The comments to be stored with the point can be edited except for <4:> if a GPS
seismic value has been recorded.
Next step
STORE (F1) stores the changes and returns to MANAGE Data: Job Name.
TPS1200+ 43
8.2.2 Mean Page
Description e Various measured coordinate triplets for one point can be recorded using the
same point ID. If the averaging mode is activated, an average is calculated.
e — It is checked if the deviations of each single point are within the configured limits.
e After averaging, the Mean page becomes available in MANAGE Edit Point:
Point ID and accessible from the Survey application program SURVEY Survey:
Job Name, Survey page.
Averaging Defining the averaging mode and configuring the limits
The averaging mode and the limits are configured in MANAGE New Job, Avge
page or in MANAGE Edit Job: Job Name, Avge page. Refer to "7.2 Creating a New
Job/Editing a Job" for further details.
Description of averaging modes
Averaging mode
Description
Average
The horizontal and height distances from the measured points
to the average are computed and displayed on the Mean
page. Depending on the selected averaging method, the
average will be computed weighted or arithmetic (no
weighting).
Absolute Diffs
The same as for Average above applies for Absolute Diffs.
Additionally, the absolute difference between two points
selected from a list of measured points which are all stored
with the same point ID are computed and checked for being
within the defined limits.
Off
Averaging functionality is turned off.
Access Access within data management
step-by-step
Step |Description
Name.
1. Refer to "6 Manage... - Getting Started" to access MANAGE Data: Job
44
In MANAGE Data: Job Name, Points page highlight a point to be edited.
EDIT (F3) to access MANAGE Edit Point: Point ID, Mean page.
TPS1200+ Manage...\Data
MANAGE
Edit Point: Point ID,
Mean page
Manage...\Data
All measured coordinate triplets recorded using the same point ID are shown.
10:35 | IR ZS" a STORE (F1)
MANAGE ` tO sol § soc To store the changes and to return to
the screen from where this screen
Ponrds | Cnde
Mean
was accessed.
USE (F2)
To include or exclude the highlighted
coordinate triplet in or from the calcu-
lation of the average.
EDIT (F3)
To view and edit the highlighted
STORE| USE | EDIT| DEL | HORE | PAGE | measured coordinate triplet.
DEL (F4)
To delete the highlighted coordinate
triplet. The average is recomputed.
MORE (F5)
To display more information in the
second column.
SHIFT DIFFS (F5)
Available for <Averaging Mode:
Absolute Diffs> and Yes is set in the
Use column for exactly two measure-
ments. To display the absolute coor-
dinate differences. Differences
exceeding the defined limit are indi-
cated by 9.
Description of columns
Column
Description
Use
dPos
The use of a measured coordinate triplet in the averaging.
USE (F2) changes between the options.
The horizontal distance from the measured coordinate triplet
to the average.
Auto
The coordinate triplet is included in the averaging compu-
tation if within the defined averaging limit.
Yes
The coordinate triplet is always included in the averaging
computation even if it would fall outside the defined aver-
aging limit.
No
The coordinate triplet is never included in the averaging
computation.
The coordinate triplet cannot be included in the averaging
computation. Automatically set by the system.
TPS1200+ 45
46
Column Description
dHt The height distance from the measured coordinate triplet to
the average.
! Available for measured coordinate triplets with Auto or Yes in
the Use column if <Averaging Mode: Average>. Indicates an
exceeding of the limits.
Next step
IF a measured
coordinate triplet
is not to be viewed
is to be viewed
THEN
STORE (F1) stores the changes and returns to MANAGE
Data: Job Name.
highlight a measured coordinate triplet and EDIT (F3).
Ce — Codes cannot be changed. A change in codes must
be an overall change for the average point.
TPS1200+ Manage...\Data
8.3 Line/Area Management
8.3.1 Overview
Description
Manage...\Data
e Aline/area consists of points and can be created/edited in MANAGE Data: Job
Name. The individual points are measured within any application program.
These can be all points, except auxillary points. Points can be simultaneously
assigned to one or more lines and/or areas.
e A line/area can have:
e a style for display in MapView.
e a code independent of the point code of the points comprising the line/area.
Points are assigned to a line/area when the line/area is open. Press USE (F4) to
open/close a line/area.
TPS1200+ 47
8.3.2 Creating a New Line/Area/Editing a Line/Area
Lë
Access
step-by-step
Lë
MANAGE
XX Line,
General page
48
Creating/editing lines/areas and the functionality of all screens and fields are similar
for lines/areas. For simplicity, only the creation/editing of a line is explained in this
chapter.
Step |Description
1. Refer to "6 Manage... - Getting Started" to access MANAGE Data: Job
Name.
PAGE (F6) until the Lines (X) page is active.
MANAGE Data: Job Name, Lines (X) page
If a line is to be edited, then highlight the line.
4. NEW (F2)/EDIT (F3) to access MANAGE New Line/MANAGE Edit Line:
Line ID.
Editing lines/areas is similar to creating a new line/area. For simplicity, the screens
are called MANAGE XX Line and differences are clearly outlined.
15:19 $ aiy
MANAGE we ei I gy s Ge STORE (F1)
a Ge a To store the line and all associated
Line ID , Lined004 information and to return to
ite to Store All Points d MANAGE Data: Job Name, Lines
Line Style. » A (X) page. Any existing lines and
No. of Pts - 0 areas which are open are closed.
Length SO am m MORE (F5)
Start Date z 04.11.03 ~ AVAIADIE a MANAGE aa ane.
Uzat Line ID. To display additional fields
STORE| | | | HORE | PAGE | with more information.
SHIFT INDIV (F5) or SHIFT RUN (F5)
To change between entering an indi-
vidual line ID different to the defined
ID template and the running line ID
according to the ID template.
Description of fields
Field Option Description
<Line ID:> User input The name of the new line.
<Pts to Store:> All Points, The type of points which are used to form
Only Msd Pts, the line during a survey.
Only Auto Pts,
Only Offset1 Pts
or
Only Offset2 Pts
TPS1200+ Manage...\Data
Manage...\Data
Field
Option
Description
<Line Style:>
<No. of Pts:>
<Length:>
<Start Time:> and
<Start Date:>
Choicelist
Output
Output
Output
Available on MANAGE New Line. This is
the line style in which lines/areas are
represented in MapView and LGO. For
<Line Code: <None>> on the Code page
a line style can be selected from a
choicelist. Otherwise the line style as
defined for the selected line code on the
Code page is shown.
The number of points contained within the
line.
Available on MANAGE Edit Line: Line
ID. The sum of the distances between the
points in the sequential order in which
they are stored for the line. This can be a
horizontal grid distance or a geodetic
distance on the WGS 1984 ellipsoid.
Available on MANAGE Edit Line: Line
ID. The time/date when the line was
created.
<End Time:> and
<End Date:>
Next step
IF
Output
THEN
Available on MANAGE Edit Line: Line ID
after pressing MORE (F5). The time/date
when the last point was added to the line.
The values do not change after deleting
the last added point or after editing unless
an additional point is added to the line.
creating a line
PAGE (F6) changes to the Code page. Refer to paragraph
"MANAGE XX Line, Code page".
editing a line
PAGE (F6) changes to the Points page. Refer to paragraph
"MANAGE Edit Line: Line ID, Points page".
TPS1200+
49
MANAGE
Edit Line: Line ID,
Points page
MANAGE
XX Line,
Code page
Creating
lines/areas most
efficiently
50
All points belonging to the line are listed. The point that was added last to the line is
at the top of the list.
15:71 | IR E 3 Iw kä ADD (F2)
MANAGE Te sml g s E g To add an existing point from the
Saan eo — a x active job to the line. A new point is
Point 30 cA Clase added before the point which was
0.000 CTRL highlighted when ADD (F2) was
pressed.
EDIT (F3)
To edit the highlighted point from the
line.
uzar REMOV (F4)
STORE| ADD | EDIT |REMOV| HORE | PAGE | To remove the highlighted point from
the line. The point itself is not deleted.
MORE (F5)
To display more information in the
second column.
Next step
PAGE (F6) changes to the Code page.
The functionality is very similar to MANAGE New Point, Code page. Refer to "8.2.1
Creating a New Point/Editing a Point".
Next step
STORE (F1) stores the changes and returns to MANAGE Data: Job Name, Lines
(X) page.
IF the task is to THEN
create
multiple lines/areas | use the hot key/user menu function FUNC Create New Line
with subsequent (Quick)/FUNC Create New Area (Quick). Pressing the hot
line/area ID’s key or selecting the function from the user menu creates and
immediately stores the new line/area. For the line/area ID, the
line/area ID template as defined in CONFIGURE ID
Templates is used. The code and attributes are taken over
from the last created line/area.
lines/areas with use quick coding. The job codelist must contain quick codes
certain codes for lines/areas. By tying the quick code a new line/area is
created and immediately stored with that line/area code and
attributes. For the line/area ID, the line/area ID template as
defined in CONFIGURE ID Templates is used.
TPS1200+ Manage...\Data
8.4 Point Sorting and Filters
8.4.1 Sorting and Filters for Points, Lines and Areas
Description
Lë
Access
step-by-step
Lë
MANAGE
Sorts & Filters,
Points page
Manage...\Data
The sort settings define the order of the objects in the active job. The filter settings
define the objects to be viewed.
An active filter for an object is indicated in MANAGE Data: Job Name by Y located
on the right hand side of the page name.
The sort and filter settings are stored in the job. They are remembered after turning
off the instrument and are copied to a new job.
When a job becomes active, then the sort and filter settings of this job are saved in
the SystemRAM. If the CompactFlash card is formatted then these last used sort and
filter settings are used for the job Default.
Step |Description
1. Refer to "6 Manage... - Getting Started" to access MANAGE Data: Job
Name.
2. In MANAGE Data: Job Name on the Points, Lines (X) or Areas (X)
page, SHIFT FILT (F5) to access MANAGE Sorts & Filters.
3. MANAGE Sorts & Filters
The page for an object is displayed when the equivalent page is displayed
in MANAGE Data: Job Name.
The functionality on the Lines (X) and Areas (X) page is similar to that on the Points
page. For simplicity, only the Points page is described.
The available fields on this screen depend on the selected setting for <Filter:>.
13:06 IR EEA E
MANAGE t STD I KN zic 8
Sorts & Filters x
Points | Ines
Sort
Ascend Point IDDU
CONT (F1)
Filter Class d|] To close the screen and return to the
CTRL screen from where this screen was
ADJ accessed.
REF STAKE (F5)
AVGE
To filter points for the Stakeout appli-
CONT | | | |STAKE| PAGE | cation program.
Description of fields
Field Option Description
<Sort:> Ascend Point ID, | Always available. The method by which
Descend Point ID, | points are sorted.
Forward Time or
Backward Time
TPS1200+ 51
Field
Option
Description
<Filter:>
No Filter
Highest Class
Range of Pt ID's
Pt ID
Wildcard
Time
Class
Instrument
Coordinate Type
Point Code
Radius From Pt
Individual Line
Individual Area
Always available. The method the points
are filtered by.
Shows all points.
Shows points of highest class.
Shows points with point ID’s between the
entered start and end ID. The points are
left aligned and sorted by the first digit.
Shows points with point ID’s matching the
wildcard. * and ? are supported. * indi-
cates an undefined number of unknown
characters. ? indicates a single unknown
character.
Shows points which were recorded within
a defined time window.
Shows points of the selected class.
Shows points originating from the
selected instrument or software program
type.
Shows points of the selected type of coor-
dinates.
Shows points with selected codes
attached.
Shows points within the defined radius
from a particular point. The radius is the
horizontal distance.
Shows points forming a selected line.
This may for example be useful during
stakeout.
Shows points forming a selected area.
This may for example be useful during
stakeout.
Next step
CONT (F1) returns to the screen from where MANAGE Sorts & Filters was
accessed.
TPS1200+
Manage...\Data
8.4.2 Point, Line and Area Code Filter
Lë
Access
step-by-step
MANAGE
Point Code Filter
Manage...\Data
For each object, a code filter exists. The point, line and area code filters are inde-
pendent from each other. The functionality is identical. For simplicity, the point code
filter is explained.
Step |Description
1. Refer to "8.4.1 Sorting and Filters for Points, Lines and Areas" to access
MANAGE Sorts & Filters.
2. MANAGE Sorts & Filters
<Filter: Point Code>.
3. CODES (F4) to access MANAGE Point Code Filter.
This screen shows the point codes from the active job and codes currently used as
filter.
12:22 IR
MANAGE Lë emm Í
Point Code Filter x| CONT (F1)
Minde Årntiwaten
1 YES To close the screen and return to the
left YES screen from where this screen was
right YES accessed.
GROUP (F4)
To activate and deactivate code
groups. Codes belonging to a deacti-
uzat vated code group are not displayed in
CONT | | | GROUP| USE | NONE | MANAGE Code Filter.
USE (F5)
To activate and deactivate the filter
for the highlighted code.
NONE (F6) or ALL (F6)
To deactivate or activate all point
codes.
SHIFT SORT (F5)
To define the order of the codes.
TPS1200+ 53
54
TPS1200+
Manage...\Data
Manage...\Codelists
9.1 Creating a New Codelist/Editing a Codelist
Access
step-by-step
Lë
MANAGE
XX Codelist
Manage...\Codelists
It is recommended to create a codelist in LGO. A codelist can be transferred from
LGO to the System RAM of the instrument using the CompactFlash card.
Step |Description
2. NEW (F2)/EDIT (F3) to access MANAGE New Codelist/MANAGE Edit
1. Refer to "6 Manage... - Getting Started" to access MANAGE Codelists.
Codelist.
Editing codelists is similar to creating a new codelist. For simplicity, the screens are
called MANAGE XX Codelist and differences are clearly outlined.
15:30 IR $ airt H
MANAGE tË STD I N HOS g
New Codelist X|
Hame : codelist
Description : meee = STORE (Ft)
To store the codelist and to return to
EES EE MANAGE Codelists.
CODES (F4)
To access MANAGE Codes where
codes can be created, edited or
zat deleted and code groups can be
STORE| | | CODES| | | accessed.
Description of fields
Field Option Description
<Name:> User input A unique name for the codelist. The name
may be up to 16 characters long and may
include spaces. Input required.
<Description:> User input A detailed description of the codelist. This
can be for example, work to be
performed. Input optional.
<Creator:> User input The person’s name who is creating the
new codelist. Input optional.
Next step
STORE (F1) stores the codelist and returns to MANAGE Codelists.
TPS1200+ 55
9.2 Creating a New Code/Editing a Code
Access
step-by-step
Lë
MANAGE
XX Code
56
Step |Description
1. Refer to "6 Manage... - Getting Started" to access MANAGE Codelists.
2. In MANAGE Codelists highlight the codelist of which codes are to be
managed.
EDIT (F3) to access MANAGE Edit Codelist.
CODES (F4) to access MANAGE Codes.
MANAGE Codes
Codes from currently active code groups are shown. The Eindicates codes
which have attributes attached.
Ce" "MORE (F5) displays information about the code description, the quick
codes if available, the code groups and the code type.
Ce _ | SHIFT GROUP (F4) To view, create, delete, activate and deactivate code
groups.
Ce _ | SHIFT SORT (F5) sorts codes by code name, code description, quick
code or the last use.
6. MANAGE Codes
If a code is to be edited, then highlight the code.
7. NEW (F2)/EDIT (F3) to access MANAGE New Code/MANAGE Edit
Code.
Editing codes is similar to creating a new code. For simplicity, the screens are called
MANAGE XX Code and differences are clearly outlined.
SmartCodes is basically a quick way for code to be selected and point to be meas-
ured. For information on configuring and using SmartCodes refer to TPS1200+
Technical Reference Manual.
17:20 IR LEE E
MANAGE +t or H d Zi
Code s e
Code Desc : centre line
Group : group
Code Type : Point «| STORE (F1)
Linework z Begin Line dy e
Line Style ` — d To add the new code and any associ-
Attribute 1 ated attributes to the System RAM
codelist and returns to the screen
(zat from where this screen was
STORE| NEW- A| NAHE | | | | accessed.
TPS1200+ Manage...\Codelists
Description of fields
Field
<Code:>
<Code Desc:>
<Group:>
<Code Type:>
<Linework:>
Manage...\Codelists
Option
User input
User input
Choicelist
Choicelist
Choicelist
None
TPS1200+
NEW-A (F2)
To add a new input field for an
attribute of attribute type normal and
of value type text. Attributes of
attribute type mandatory or fixed and
of value type real or integer must be
created in LGO. Up to twenty
attributes can be created.
NAME (F3) or VALUE (F3)
Available for attributes for which an
attribute name can be typed in. To
highlight the field for the attribute
name or the field for the attribute
value. The attribute name can be
edited and the attribute value to be
used as the default attribute value
can be typed in.
Description
A unique name for the new code. The
name may be up to 16 characters long
and may include spaces. Input required.
A detailed description of the code. This
can be for example the full designation if
<Code:> is an abbreviation. Input
optional.
The code group to which the code is to be
assigned.
Defines the use of the code. It can be used
as thematical code for points, lines or
areas or as a free code. It makes a code
unique. For example <Code: Oak> can
have <Code Type: Point>, <Code Type:
Line>, <Code Type: Area> and/or
<Code Type: Free> within the same
codelist and job.
Available for <Code Type: Point> only.
This field allows a new line or new area to
be opened whenever the point code is
newly selected. This functionality is also
available when creating codelists with
LGO Codelist Management.
Select this option to disable the function-
ality. All other code settings on the instru-
ment are not affected when this option is
set.
57
58
Field Option
Begin Line
Begin Area
Description
When a point code is newly selected, a
new line is opened and the point being
stored is added to the line. When the
same point code remains selected, a new
line is not opened. The point being stored
is simply added to the current line.
The behaviour for opening a new area is
the same as the behaviour for opening a
new line, as mentioned above.
<Line Style:> Choicelist
Next step
Not available for <Code Type: Free>. The
style in which lines and areas are repre-
sented in MapView and LGO.
STORE (F1) adds the code to the codelist/stores the changes and returns to
MANAGE Codelists.
TPS1200+
Manage...\Codelists
10 Linework
10.1 Performing Linework
Lë
Requirements
Access
step-by-step
SURVEY
Survey: Job Name,
Survey page
Linework
The Survey application program is used here to explain Linework.
e Adisplay mask with a choicelist for Linework must be configured.
e The flags for Linework must be defined in CONFIGURE Coding & Linework
Settings, Linework page.
Step |Description
1. Select Main Menu: Survey to access SURVEY Survey Begin.
2. In SURVEY Survey Begin select a job.
3. Select a configuration set.
4. Select an reflector.
5, CONT (F1) to access SURVEY Survey: Job Name.
The most important keys are explained.
18:58 | IR Ss"? aw ALL (F1)
SURVEY + & STD I RK ROG To measure and store distances and
Survey: active job
RR Col angles.
Point ID 0004 STOP (F1)
Code EBIT A Available if <EDM Mode: Tracking>
Code Typo: ane and DIST (F2) was pressed. Stops
: Begin Line
t k i
Thewor the distance measurements. (F1)
changes back to ALL.
DIST (F2)
DECK To measure and display distances.
ALL | DIST| REC | |SETAZ| PAGE | Available unless <EDM Mode:
Tracking> and/or <Log Auto Pts:
Yes>, after the tracking or logging is
started.
REC (F3)
To record data. If <EDM Mode:
Tracking> and/or <Log Auto Pts:
Yes>, records measured point and
continues tracking.
Description of fields
Field Option Description
<Point ID:> User input The identifier for manually occupied
points. The configured point ID template
is used. The ID can be changed in the
following ways:
TPS1200+ 59
Field
<Linework:>
60
Option
Begin Line
3pt Curve
ReOpen Any Line
ReOpen Last Line
End Line
Cont Line/Area
Start Spline
End Spline
Cont Spline
TPS1200+
Description
e Tostart anew sequence of point ID's
type over the point ID.
e For an individual point ID inde-
pendent of the ID template SHIFT
INDIV (F5). SHIFT RUN (F5)
changes back to the next ID from the
configured ID template.
The linework flag to be stored with the
point.
No linework flag is stored.
Opens a new line when the next point is
stored. Any line/area which is currently
open is closed and the last point
belonging to that line/area is given the
End Line/Close Area linework flag. The
point may or may not be stored with a
point code.
Stores the linework flag for a curve
through three points and continues a
line/area.
Opens a line from a list of all lines which
are currently stored in the job when the
next point is stored. The last code used
with the reopened line is automatically
selected when the point is stored. Any
line/area which is currently open is closed
and the last point belonging to that
line/area is given the
End Line/Close Area linework flag.
Opens the last used line again. The last
code used with the reopened line is auto-
matically selected when the point is
stored.
Closes all open lines.
Indicates a line/area is open.
Stores the linework flag for beginning a
spline and continues any open line/area.
Closes a spline and continues any open
line/area.
Indicates a line/area is open with spline
line type.
Linework
Field Option Description
Begin Area Opens a new area when the next point is
stored. Any line/area which is currently
open is closed and the last point
belonging to that line/area is given the
End Line/Close Area linework flag. The
point may or may not be stored with a
point code.
ReOpen Any Area | Opens an area from a list of all lines which
are currently stored in the job when the
next point is stored. The last code used
with the reopened area is automatically
selected when the point is stored. Any
line/area which is currently open is closed
and the last point belonging to that
line/area is given the
End Line/Close Area linework flag.
ReOpen Last Opens the last used area again. The last
Area code used with the reopened area is auto-
matically selected when the point is
stored.
Close Area Closes all open areas.
Next step
Step |Description
1. Go to the point to be occupied.
2. Select the linework flag to be stored with the next point.
3. ALL (F1)
Ce" | Depending on the option selected for <Linework:>, a line/area is opened,
closed or re-opened.
4. Repeat steps 1. to 3. until all points are occupied.
5. SHIFT QUIT (F6) to exit the Survey application program.
6. Use a format file to export the points including the linework flags.
Linework
TPS1200+ 61
10.2
Description
Requirements
Lë
Access
step-by-step
SURVEY
Survey: Job Name,
Survey page
62
Combining Linework and Coding
Combining Linework and coding can only be configured if thematical point codes or
if thematical point, line and area codes are available for selection. Thematical coding
can be done with or without codelists.
e Adisplay mask must be configured with:
e a field for codes.
e achoicelist for Linework.
e The configuration of a field for code types in a display mask is required for
working with point, line and area codes without choicelist. Else the configuration
of a field for code types is optional.
e Configure in CONFIGURE Coding & Linework, Coding page
e <Show Codes: Only Pt Codes> or <Show Codes: All Codes>.
e <Thematc Codes: With Codelist> or <Thematc Codes: Without
Codelist>.
e In CONFIGURE Coding & Linework Settings, Linework page define the flags
for Linework.
The Survey application program is used here to explain the combination of Linework
and coding.
Step |Description
1. Select Main Menu: Survey to access SURVEY Survey Begin.
2. In SURVEY Survey Begin select a job.
3. Select a configuration set.
4. Select an reflector.
5. CONT (F1) to access SURVEY Survey: Job Name.
This is what a display mask configured for Linework and coding looks like. The most
important keys are explained.
13:27
SURVEY
Survey: active job
Survey |Ottset [Uode | Auto
Point ID
Code ei dl
Code Type Point =
Linework Begin Line d
Horiz Dist 54.905 m
Y : 37.0007 y
Ret lector
Leica Cire Prism dell
eat
ALL | DIST| REC | |SETAZ| PAGE |
TPS1200+
ALL (F1)
To measure and store distances and
angles.
STOP (F1)
Available if <EDM Mode: Tracking>
and DIST (F2) was pressed. Stops
the distance measurements. (F1)
changes back to ALL.
Linework
DIST (F2)
To measure and display distances.
Available unless <EDM Mode:
Tracking> and/or <Log Auto Pts:
Yes>, after the tracking or logging is
started.
REC (F3)
To record data. If <EDM Mode:
Tracking> and/or <Log Auto Pts:
Yes>, records measured point and
continues tracking.
Linework and These step-by-step instructions refer to the previous screen.
coding
step-by-step For <Show Codes: Only Pt Codes>
Step | Field Description for thematical coding
With codelist Without codelist
1. <Code:> Select a code from the Type in a code.
choicelist. Only point codes
are available for selection.
Ce" <None> to store a point | -===- to store a point without
without code or to perform |code or to perform Linework
Linework without coding. without coding.
2. <Code Point is displayed. This field is an output field. It can not be
Type:> changed.
3. <Linework:> | Select an option for the Linework flag to be stored with the
point.
E S e to store a point without Linework flag or to perform
coding without Linework.
4. - ALL (F1)
Lo |s e The point is stored with the selected code.
- e Depending on the selection for <Linework:>, a
line/area is opened/closed.
For <Show Codes: All Codes>
Step | Field Description for thematical coding
With codelist Without codelist
1. <Code:> Select a code from the Type in a code.
choicelist. Point, line and
area codes are available for
selection.
Ce" <None> to store a point | -===- to store a point without
without code or to perform |code or to perform Linework
Linework without coding. without coding.
Linework TPS1200+ 63
64
Step | Field Description for thematical coding
With codelist Without codelist
2. <Code The type of the selected Select the type of the
Type:> code. This field is an output | entered code.
field. It can not be changed.
3. <Linework:> | Select an option for the Linework flag to be stored with the
point.
CSP | sf ne to store a point without Linework.
4. - ALL (F1)
a> i+ e Ifa point code was selected, the point is stored with the
selected code.
e Ifa line/area code was selected, the point is stored as
part of the line/area.
e Depending on the selection for <Linework:>, a
line/area is opened/closed.
TPS1200+ Linework
11 Manage...\Coordinate Systems
11.1 Overview
Description A coordinate system:
e consists of up to five elements.
e allows the conversion from WGS 1984 geodetic or cartesian coordinates to local
cartesian, geodetic or grid coordinates and back.
Elements of The five elements which define a coordinate system are:
coordinate system >œ» a transformation
e a projection
e an ellipsoid
e ageoid model
e a Country Specific Coordinate System model
Manage...\Coordinate Systems TPS1200+ 65
11.2 Creating a New Coordinate System/Editing a Coordinate System
Access
step-by-step
Lë
MANAGE
XX Coordinate
System
66
Step |Description
1. Refer to "6 Manage... - Getting Started" to access MANAGE Coordinate
Systems.
2. In MANAGE Coordinate Systems highlight a coordinate system. When
creating a new coordinate system, a copy of this coordinate system is
taken for further configurations.
3. NEW (F2)/EDIT (F3) to access MANAGE New Coordinate
System/MANAGE Edit Coordinate System.
Editing a coordinate system is similar to creating a new coordinate system. For
simplicity, the screens are called MANAGE XX Coordinate System and differences
are clearly outlined.
When editing a coordinate system the transformation type of the selected coordinate
system determines the availability and the options of the subsequent fields. Most
fields are identical with those for the creation of a new coordinate system.
Description of fields
Field Option ` Description
<Name:> User input A unique name for the coordinate system.
The name may be up to 16 characters
long and may include spaces.
Available for transformations with control
points. The method by which residuals are
distributed throughout the transformation
area.
<Residuals:>
None No distribution is made. Residuals remain
with their associated points.
XX
1/Distance
Distributes the residuals according to the
distance between each control point and
the newly transformed point.
Multiquadratic Distributes the residuals using a multi-
quadratic interpolation approach.
<Transform:> Choicelist The type of transformation.
<PreTransform:> | Output Available for editing Twostep transforma-
tions. The name of a preliminary 3D trans-
formation which is used together with the
selected projection to obtain preliminary
grid coordinates to be used for a final 2D
transformation.
<Ellipsoid:> Choicelist Available unless projection <Type:
Customised>. The local coordinates are
based on this ellipsoid.
TPS1200+ Manage...\Coordinate Systems
Next step
Field Option Description
<Projection:> Choicelist The map projection.
<Geoid Model:> | Choicelist The geoid model.
<CSCS Model:> | Choicelist The Country Specific Coordinate System
model.
STORE (F1) stores the coordinate system and returns to MANAGE Coordinate
Systems.
Manage...\Coordinate Systems
TPS1200+
67
11.3 Transformations/Ellipsoids/Projections
11.3.1 Accessing Transformation/Ellipsoid/Projection Management
Access
step-by-step
68
Step |Description
1. Refer to "6 Manage... - Getting Started" to access MANAGE Coordinate
Systems.
2. In MANAGE Coordinate Systems highlight a coordinate system to be
edited.
EDIT (F3) to access MANAGE Edit Coordinate System.
In MANAGE Edit Coordinate System highlight <Transform:>, <Ellip-
soid:> or <Projection:>.
5. ENTER to access MANAGE XX.
Ce |The screen is similar to MANAGE Coordinate Systems. Refer to "6
Manage... - Getting Started" for information on the softkeys.
Ce |in MANAGE Transformations all Classic 3D transformations stored in
the database DB-X are listed.
Next step
IF THEN
a transformation/ellip- | highlight the desired transformation/ellipsoid/projection.
soid/projection is to be |CONT (F1) closes the screen and returns to the screen
selected
from where MANAGE XX was accessed.
a transformation/ellip- | highlight the transformation/ellipsoid/projection and
soid/projection is to be | NEW (F2)/EDIT (F3). Refer to "11.3.2 Creating/Editing a
created or edited Transformation/Ellipsoid/Projection".
TPS1200+ Manage...\Coordinate Systems
11.3.2 Creating/Editing a Transformation/Ellipsoid/Projection
Lë
Lë
Access
step-by-step
Lë
MANAGE
XX Transformation,
General page
MANAGE
XX Transformation,
Parameters page
MANAGE
XX Transformation,
More page
Creating/editing an ellipsoid/projection is very similar to creating/editing a transfor-
mation which is explained below. The main difference is that MANAGE XX Ellipsoid
and MANAGE XX Projection do not use pages and all the information is input on
one screen.
Classic 3D transformations can be created.
Step |Description
1. Refer to "11.3.1 Accessing Transformation/Ellipsoid/Projection Manage-
ment" to access MANAGE Transformations.
2. In MANAGE Transformations highlight a transformation. When creating
a new transformation/ellipsoid/projection, a copy of this transforma-
tion/ellipsoid/projection is taken for further configurations.
3. NEW (F2)/EDIT (F3) to access MANAGE New Transforma-
tion/MANAGE Edit Transformation.
Editing a transformation is similar to creating a new transformation. For simplicity,
the screens are called MANAGE XX Transformation and differences are clearly
outlined.
Description of fields
Field Option Description
<Name:> User input A unique name for the new transforma-
tion. The name may be up to 16 charac-
ters long and may include spaces.
|<Type:> [Output [No other transformations than Classic 3D |
can be created.
Next step
PAGE (F6) changes to the Parameters page.
Enter the known values of the transformation parameters.
Next step
PAGE (F6) changes to the More page.
Description of fields
Field Option Description
<Height Mode:> | Choicelist or The type of heights to be computed.
Output When editing a transformation, the option
cannot be changed.
Manage...\Coordinate Systems TPS1200+ 69
70
Field
Option
Description
<Transf Model:>
Next step
Choicelist
The transformation model to be used. For
<Transf Model: Molodensky-Bad>,
additional input fields are available.
STORE (F1) stores the transformation and returns to MANAGE Transformations.
TPS1200+
Manage...\Coordinate Systems
11.4 Geoid/CSCS Models
Lë
Access
step-by-step
MANAGE
Geoid Models
The creation of CSCS models on the instrument and the functionality of all screens
and fields is similar to those of geoid models. For simplicity, geoid models are used
as an example in this chapter.
Step |Description
1. Refer to "6 Manage... - Getting Started" to access MANAGE Coordinate
Systems.
2. In MANAGE Coordinate Systems highlight a coordinate system to be
edited.
EDIT (F3) to access MANAGE Edit Coordinate System.
In MANAGE Edit Coordinate System highlight <Geoid Model:>.
ENTER to access MANAGE Geoid Models.
All geoid models stored in the database DB-X are listed. Any unavailable information
is shown as ----- , for example, if the geoid field file which was associated to the geoid
model is not available on the CompactFlash card / internal memory.
14:45 Tor r TELI CONT (F1)
STD Bice g 4 To select the highlighted geoid model
Ges and to return to the previous screen.
aoe CFCRD (F2)
To create a new geoid model. For
each geoid field file on the Compact-
Flash card, one geoid model is auto-
matically created.
EDIT (F3)
uzat To view the highlighted geoid model.
CONT |CFCRD| EDIT | DEL | | INTL | None of the fields can be edited.
DEL (F4)
To delete the highlighted geoid
model. The geoid field file which was
associated with this geoid model is
then also deleted.
INTL (F6)
To create a new geoid model. For
each geoid field file in the internal
memory, one geoid model is auto-
matically created.
Manage...\Coordinate Systems TPS1200+ 71
72
TPS1200+
Manage...\Coordinate Systems
12 Manage...\Configuration Sets
12.1 Overview
Description
Default
configuration sets
User defined
configuration sets
The instrument has numerous user configurable parameters and functions. This
allows a variety of preferences to be addressed. The configuration of the parameters
and functions for an individual measuring technique are combined in a configuration
set.
Default configuration sets exist on the instrument. They use standard settings for the
majority of application programs. Default configuration sets can be edited and
deleted. It is always possible to restore the default configuration sets.
New configuration sets can be created. The configuration set wizard assists in
editing configuration sets.
Manage...\Configuration Sets TPS1200+ 73
12.2 Creating a New Configuration Set
Access
step-by-step
MANAGE
New Configuration
Set
74
Step
1.
Description
Refer to "6 Manage... - Getting Started" to access MANAGE Configura-
tion Sets.
In MANAGE Configuration Sets highlight a configuration set. A copy of
this configuration set is taken for further configurations.
NEW (F2) to access MANAGE New Configuration Set.
Description of fields
Field Option Description
<Name:> User input A unique name for the new configuration
set.
<Description:> User input A detailed description of the configuration
set, since the name of a configuration set
is usually an abbreviation. Input optional.
<Creator:> User input The person’s name who creates the new
configuration set. Input optional.
Next step
STORE (F1) accesses the next subsequent screen in the configuration wizard.
Refer to the chapters "Config...\XX" for information on the screens.
TPS1200+ Manage...\Configuration Sets
12.3 Editing a Configuration Set
Access
step-by-step using
configuration set
wizard
Access
without using
configuration set
wizard
Step |Description
iP Refer to "6 Manage... - Getting Started" to access MANAGE Configura-
tion Sets.
2. In MANAGE Configuration Sets highlight a configuration set to be
edited.
3. EDIT (F3) to access CONFIGURE Wizard Mode. This starts the sequen-
tial configuration set wizard.
4. Refer to "Config...\XX" for information on the screens.
The currently active configuration set can be edited. Choose one of the following
options and access the required screens to edit the configuration set.
Select Main Menu: Config....
OR
From inside an application program press USER and then CONF (F2).
OR
In CONFIGURE Wizard Mode, press LIST (F6). Refer to "12.2 Creating a New
Configuration Set".
Manage...\Configuration Sets TPS1200+ 75
76
TPS1200+
Manage...\Configuration Sets
13 Manage...\Reflectors
13.1 Overview
Description e Each reflector type has an additive constant.
e Leica Geosystems reflectors are predefined as default and can be selected.
e Additional reflectors can be defined.
Manage...\Reflectors TPS1200+ 77
13.2 Creating a New Reflector/Editing a Reflector
Access
step-by-step
Lë
MANAGE
XX Reflector
78
Step |Description
1. Refer to "6 Manage... - Getting Started" to access MANAGE Reflectors.
2. In MANAGE Reflectors highlight a reflector. When creating a new
reflector, the <Type:> of the new reflector is taken from the previously
highlighted reflector except for RL reflectors.
3. NEW (F2)/EDIT (F3) to access MANAGE New Reflector/MANAGE Edit
Reflector.
Editing reflectors is similar to creating a new reflector. For simplicity, the screens are
called MANAGE XX Reflector.
Description of fields
Field Option Description
<Name:> User input or A significant name for the new reflector.
Output
<Type:> Prism, Tape or The type of reflector to be defined.
Undefined
<Add. Constant:> | User input The additive constant is always in [mm].
Ce An additive constant of 0.0 mm
has been defined for the Leica
Geosystems standard reflec-
tors GPR1, GPR111, etc. All
entered or selected additive
constant values are differences
to this 0.0 mm based Leica
Geosystems TPS prism
system.
<Creator:> User input A name of the creator or other comments
can be entered.
Next step
STORE (F1) stores the new reflector and returns to MANAGE Reflectors.
TPS1200+
Manage...\Reflectors
14 Convert...\Export Data from Job
14.1 Overview
Description e This screen lists all the exporters loaded.
e Data can be exported
e toa file on the CompactFlash card.
e toa file on the internal memory if fitted.
e via RS232 to an external device.
Export format The format file must be composed individually as format file using LGO. Refer to the
online help of LGO for information on creating format files.
Convert...\Export Data from Job TPS1200+ 79
14.2 Exporting ASCII Data
Description
Requirements
Access
EXPORT
Export ASCII Data
from Job
80
The settings on this screen define the data that is converted and exported and what
format is used.
Data is exported from the selected job. Currently active view, filter and sort settings
are applied. The points that are exported are those that are visible in MANAGE
Data: Job Name.
At least one format file was created using LGO and has been transferred to the
System RAM.
Select Main Menu: Convert...\Export Data from Job\Export ASCII.
ga Dei SEA CONT (F1)
EXPORT STD To export the data.
Export ASCII Data L Ze =] CONF (F2)
Export T CF Card QD
pire cove = = t To define the default extension for
the export file and to select the
Job : fixpoi job dp i
a PE. point jobt behaviour for the setup measure-
ments.
Format File : format file FRrdd FILT (F4)
FE E TE To set the sort and filter settings for
ža t export. The setting for <Sort:> on the
CONT | CONF | | FILT | | csys | Points page defines the order in
which points, lines and areas are
exported. The setting for <Filter:> on
each page defines which points, lines
or areas are exported.
IFACE (F5)
Available for <Export To: RS232>.
To choose the port and device to
which the data should be exported.
CSYS (F6)
To update the coordinate system in
which the coordinates are exported.
Description of fields
Field Option Description
<Export To:> CF Card, Defines to where the exported file should
Internal Memory if | be written.
fitted, or RS232
<Directory:> Data, GSI or /Root | Available for <Export To: CF Card>. The
data can be exported to the \Data, the
\GIS or the root directory. Data must be
stored to the \GSI directory in order to
read it in a TPS1100. For <Export To:
Internal Memory>, the data is always
exported to the \Data directory.
TPS1200+ Convert...\Export Data from Job
Field
Option
Description
<Job:>
Choicelist
If points from a job on the internal memory
are to be exported, open this choicelist.
When in this choicelist press CFCRD (F6)
or INTL (F6) to select a job from a
different memory device.
<Coord System:>
<Format File:>
<File Name:>
<Port:>
Output
Choicelist
User input
Output
The coordinate system currently attached
to the selected <Job:>.
The format files currently available in the
System RAM.
Available for <Export To: CF Card> and
<Export To: Internal Memory>. The
name of the file to which the data should
be exported. The name is automatically
suggested based on the job name to be
exported and an extension.
Available for <Export To: RS232>.
Displays the port currently configured to
be used with RS232.
<Device:>
Output
The device currently configured to be
used with <Port:>.
Convert...\Export Data from Job
TPS1200+
81
14.3 Exporting DXF Data
General
Access
DXF Export
Export DXF from
Job
82
Data can be exported to a DXF file in the \DATA directory of the CompactFlash card
or the internal memory, if fitted.
Select Main Menu: Convert...\Export Data from Job\DXF Export.
BE EE | Es ©
EXPORT Le" STD 2 ër
Export DXF from sro
Job : survey jobah
Coord System : <Hone>
H CONT (F1)
File Name p surve ob.dxf To export the data.
CONF (F2)
Progress d To define elements to be exported,
uzat how they will be exported and if
CONT | CONF | | | | | labels will be created.
Description of fields
Field Option Description
<Job:> Choicelist If points from a job on the internal memory
are to be exported, open this choicelist.
When in this choicelist press CFCRD (F6)
or INTL (F6) to select a job from a different
memory device.
<Coord System:> | Output The coordinate system currently attached
to the selected <Job:>.
<File Name:> User input Available for <Export To: CF Card> and
<Export To: Internal Memory>. The
name of the file to which the data should
be exported. The name is automatically
suggested based on the job name to be
exported and extension dxf.
<Progress:> Output Progress bar. Displays progress of the
export.
TPS1200+ Convert...\Export Data from Job
14.4 Exporting LandXML Data
General Data can be exported to a LandXML file in the \DATA directory of the CompactFlash
card or the internal memory, if fitted.
Access Select Main Menu: Convert...\Export Data from Job\Export LandXML.
EXPORT 17:37 IR - % vA, E
Export LandXML EXPORT Ce sro L a
from Job Export Land Hl from Job
Job d Defaulthi
Coord System : <Hone> CONT (F1)
, To export the data.
File Name : Default. xm] CONF (F2)
To define elements to be exported,
Progress Eoo E how they will be exported, the dimen-
sion of the file exported and the
| i
CONT | CONF | | | | : | LandXML version.
Description of fields
Field Option Description
<Job:> Choicelist If points from a job on the internal memory are to
be exported, open this choicelist. When in this
choicelist press CFCRD (F6) or INTL (F6) to
select a job from a different memory device.
<Coord Output The coordinate system currently attached to the
System:> selected <Job:>.
<File Name:> | User input The name of the file to which the data should be
exported. The name is automatically suggested
based on the job name to be exported and
extension xml.
<Progress:> | Output Progress bar. Displays progress of the export.
Convert...\Export Data from Job TPS1200+ 83
84
TPS1200+
Convert...\Export Data from Job
15 Convert...\lmport Data to Job
15.1 Overview
Description e This screen lists all the importers loaded. The data to import must either be
stored on the CompactFlash card or in the internal memory, if fitted.
e Data can be imported to a job:
e onthe CompactFlash card.
e on the internal memory, if fitted.
Import formats Data can be imported in ASCII, GSI8, GSI16 or DXF format.
Access
Step |Description
step-by-step
1. Select Main Menu: Convert...\Import Data to Job to access IMPORT
Import Data to Job Menu.
2. IMPORT Import Data to Job Menu
The Import Data to Job menu lists all the converters for importing data.
Highlight the Import Data converter to be started.
e? CONT (F1) to access the screen for the Import Data converter.
Ce |The screens for each Import Data converter can be accessed directly by
pressing a configured hot key or USER.
Convert...\Import Data to Job TPS1200+ 85
15.2 Importing ASCII/GSI Data
Requirements
Access
IMPORT
Import ASCII/GSI
Data to Job
86
s For ASCII files:
e Atleast one ASCII file with any file extension is stored in the \DATA directory
of the CompactFlash card.
e For GSI files:
e At least one ASCII file in GSI format with the file extension *.gsi is stored in
the \GSI directory of the CompactFlash card.
Refer to "15.1 Overview" to access Import ASCII/GSI Data to Job.
voor ent da CSR) CONT (F1)
IMPORT Lë STD noer g To import the data.
From : Interia henori dy
Import . ASCII Data d For <Import: ASCII Data>: To select
From File logfile. txt 4p the delimiter, the positions of the
To Job : active bbe: particular variables and, if required,
Header he ‘| the number of lines used to describe
each point or if the variables are
delimited by one or multi spaces.
uzat For <Import: GSI Data>: Coordi-
CONT | CONF | VIEW | | | | nates can be switched for "left
handed" coordinate systems. All
WI 81 data, normally Easting, is then
imported as Northing and all WI 82
data, normally Northing, is then
imported as Easting.
VIEW (F3)
To display the data in <From File:>.
SHIFT HTS (F2)
To define the height type for the
imported data and if the Easting
should be multiplied by -1. This is
required by some coordinate
systems.
Description of fields
Field Option = Description
<From:> Choicelist ASCII/GSI Data can be imported to a job,
from the CompactFlash Card or Internal
memory.
<Import:> Choicelist The type of data to be imported.
<From File:> Choicelist For <Import: ASCII Data> all files in the
\DATA directory on the CompactFlash
card can be selected.
For <Import: GSI Data> all files in the
\GSI directory on the CompactFlash card
can be selected.
TPS1200+ Convert...\Import Data to Job
Field Option Description
<To Job:> Choicelist Choosing a job as destination for import
makes this job the active job.
<Header:> None and Available for <Import: ASCII Data>. This
from 1 to 10 option allows up to ten header lines which
may exist in an ASCII file to be skipped.
Select the number of header lines.
Convert...\Import Data to Job TPS1200+ 87
15.3 Importing DXF Data
Requirements e Atleast one DXF file with the file extension *.dxf has to be stored in the \DATA
directory of the CompactFlash card.
Access Refer to "15.1 Overview" to access Import DXF Data to Job.
DXF IMPORT 1718 Lei + an aN n CONT (F1)
Import DXF Data to IMPORT STD = To import the data.
Job Import DXF Data to a x| CONF (F2)
Frai File RTT To define an optional prefix for
To Job survey joba blocks, points and/or lines, to select
the file units, to activate the creation
of points at vertices of the imported
geometric elements, to convert white
Progress d colored elements to black colored
zat elements, if required and to exclude a
CONT | CONF | | | | | height value from conversion.
Description of fields
Field Option Description
<From:> Choicelist DXF data can be imported to a job, from either
the CompactFlash card or internal memory.
<To Job:> Choicelist Choosing a job as destination for import makes
this job the active job.
<Progress:> | Output Progress bar of the import procedure.
88 TPS1200+ Convert...\Import Data to Job
16 Convert...\Copy Points Between Jobs
Description
Access
COPY
Copy Points
Between Jobs
This chapter explains the process of copying points from one job to another.
Select Main Menu: Convert...\Copy Points Between Jobs.
=o gy CONT (F1)
Rice ® To copy a selection of points.
16:39 IR ji
COPY +@ STD I H
Copy Points Between Jobs x| FILT (F4)
deen Gites i SE t To define the point sort and/or point
filter settings of points from the job
To Job EES <From Job:>.
DATA (F5)
To view, edit and delete points, lines
and areas stored with the job. Points,
uzat lines and areas are shown on sepa-
H
CONT | | | FILT | DATA | CSYS | rate pages. Selected sort and filter
| | settings apply.
CSYS (F6)
To select a different coordinate
system.
Description of fields
Field Option Description
<From Job:> Choicelist Describes where the points are to be
copied from.
<Coord System:> | Output The coordinate system which is currently
attached to the job <From Job:>.
<To Job:> Choicelist Describes where the points are to be
copied to.
Convert...\Copy Points Between Jobs TPS1200+ 89
90
TPS1200+
Convert...\Copy Points Between Jobs
17 Config...\Survey Settings...
17.1 ID Templates
17.1.1 Overview
Description ID templates are predefined templates for point, line or area numbers. ID templates
save having to type in the ID for each object. They are useful when many points are
collected quickly.
Access Select Main Menu: Config...\Survey Settings...\ID Templates.
CONFIGURE Description of fields
ID Templates gg
Field Option Description
<Survey Pts:> Choicelist Sets the ID templates for measured
points.
<Auto Pts:> Choicelist Sets the ID templates for auto points.
These points are automatically recorded
at a specific rate.
<Lines:> Choicelist Sets the ID templates for lines.
<Areas:> Choicelist Sets the ID templates for areas.
Next step
CONT (F1) closes the screen and returns to the screen from where CONFIGURE ID
Templates was accessed.
Config...\Survey Settings...
TPS1200+
91
17.1.2 Creating a New ID Template/Editing an ID Template
Access
step-by-step
Lë
CONFIGURE
XX ID Template
92
Step |Description
configurations.
1. Refer to "17.1.1 Overview" to access CONFIGURE ID Templates.
2. In CONFIGURE ID Templates highlight any field.
3. ENTER to access CONFIGURE ID Template Library.
4. Highlight an ID template. A copy of this ID template is taken for further
5. NEW (F2)/EDIT (F3) to access CONFIGURE New ID
Template/CONFIGURE Edit ID Template.
Ce | DEL (F4) deletes the highlighted template.
Editing ID templates is similar to creating a new ID template. For simplicity, the
Description of fields
screens are called MANAGE XX ID Templates and differences are clearly outlined.
Field Option Description
<ID:> User input The name of the ID template.
<Increment:> Numeric only The rightmost numeric part Is incre-
Alphanumeric
<Increment By:> | User input
<Cursor Posn:> |Last Character or
from 1 to 16
Next step
Library.
mented within the point ID.
The rightmost character within the point
ID is incremented regardless of whether
that character is numeric or alphanu-
meric.
The amount by which the point ID is incre-
mented.
The character position at which the cursor
is placed when ENTER is pressed in
<Point ID:> when surveying points.
CONT (F1) stores the ID template and returns to CONFIGURE ID Template
TPS1200+
Config...\Survey Settings...
17.2 Display Settings
Description
Access
CONFIGURE
Display Settings
CONFIGURE
Define Display
Mask n
Display settings define the parameters shown on a page on the SURVEY screen.
Four display masks are definable.
Mask 1: Always shown on the SURVEY screen.
Mask 2: Can be shown or hidden on the SURVEY screen.
Mask 3: Can be shown or hidden on the SURVEY screen.
Mask 4: Never shown on the SURVEY screen.
Reserved for application programs.
Select Main Menu: Config...\Survey Settings...\Display Settings.
16:45
CONFIGURE Ar ek STD
Display — y
Define
Hame : Survey
Use in Survey: Yes CONT (F1)
To accept changes and return to the
screen from where this screen was
accessed.
DMASK (F3)
uzat To configure the selected display
CONT | | DHASK| | | | mask.
Description of fields
Field Option Description
<Define:> Mask Selected display mask.
1,2,30r4
<Use in Survey:> | Output Indicates if the display mask is shown or
hidden as a page in SURVEY.
Next step
DMASK (F3) accesses CONFIGURE Define Display Mask n.
16:4?
CONFIGURE
Name
CONT (F1)
Fixed Lines : To accept changes and to return to
dst Line : Point ID: . e
at e Reflector Height ii CONFIGURE Display Settings.
3rd Line S Line Space Full d CLEAR (F4)
4th Line : Hz- Ang Te d To set all fields to <XX. Line: Line
5th Line : Y- Angle + Space Full>.
bth Line : Horiz Diet (pe
gża q DEFLT (F5)
CONT | | CLEAR| DEFLT| | To recall the default settings.
Config...\Survey Settings... TPS1200+ 93
94
Description of fields
Field Option Description
<Name:> User input Name of display mask.
<Visible:> Yes or No Shows or hides the display mask as a
page in SURVEY.
<Fixed Lines:> From 0 to 5
<1st Line:> Output
<2nd Line:> to Choicelist
<16th Line:>
Next step
Defines how many lines do not scroll in
the survey screen when that display mask
is used.
Fixed to <1st Line: Point ID>.
For each line an option can be selected.
CONT (F1) returns to CONFIGURE Display Settings.
TPS1200+
Config...\Survey Settings...
17.3 Coding & Linework Settings
Description
Access
CONFIGURE
Coding &
Linework,
Coding page
The settings on this screen define the method of coding. For information on config-
uring and using SmartCodes refer to TPS1200+ Technical Reference Manual.
Select Main Menu: Config...\Survey Settings...\Coding & Linework Settings.
Description of fields
Field
Option
Description
<Quick Code:>
Never, On or
Off
Determines if quick coding is never avail-
able, activated or available but deactivated.
<Digits:>
<Rec Free Code:>
1,20r3
After Point or
Before Point
Available unless <Quick Code: Never>.
Sets the mostly used number of digits for the
quick code.
Available unless <Quick Code: Never>.
Determines if a free code measured with a
quick code is stored before or after the point.
<Attributes:>
<Mand Attribs:>
<Thematc
Codes:>
<Show Codes:>
<String Attrib:>
Config...\Survey Settings...
Default Values
or Last Used
Always
Prompt
Only If No
Value
Code Change
Only
With Codelist
Without
Codelist
Only Pt Codes
or All Codes
Choicelist
TPS1200+
Determines the attribute values displayed
under certain circumstances. This is appli-
cable to both the storing and displaying of
attribute values.
The screen XX Enter Mandatory Attribute
will always appear when codes, having one
or more attributes of attribute type manda-
tory, are being stored.
The screen XX Enter Mandatory Attribute
will only appear when codes, having one or
more attributes of attribute type mandatory,
are being stored without an attribute value.
The screen XX Enter Mandatory Attribute
will only appear when a new code with a
mandatory attribute was selected.
Codes stored within the job codelist can be
selected to code points, lines and areas.
Codes stored within the job codelist cannot
be selected to code points, lines and areas.
Each code must be entered manually.
Either only point codes or all codes of the job
codelist will be available in the choicelist for
<Code:>/<Point Code:> in a display mask
of an application program. Selecting a
line/area code opens a new line/area.
Available for <Show Codes: All Codes>.
When this field is active, surveyed points that
have the same code attached are strung to
one line.
95
CONFIGURE
Coding &
Linework,
Linework page
96
Next step
PAGE (F6) changes to the Linework page.
The flags for Linework are defined on this screen.
The flags defined on this screen are linked to the options available for <Linework:>
in a display mask of an application program. The selection for <Linework:> in a
display mask determines the flag stored with a point. The availability of <Linework:>
in a display mask is configured in CONFIGURE Define Display Mask n.
Description of fields
Field Option Description
<Begin Line:> User input Opens a new line when the next point is
stored. Any lines which are currently open
are closed. The point may or may not be
stored with a point code.
<3pt Curve:> User input Stores the linework flag for a curve
through three points and continues a
line/area.
<ReOpen Last Line:> | User input Opens the last used line again.
<End Line:> User input Closes all open lines.
<Cont Line/Area:> User input Indicates a line/area is open.
<Start Spline:> User input Stores the linework flag for beginning a
spline and continues any open line/area.
<End Spline:> User input Stores the linework flag to stop a spline.
<Cont Spline:> User input Indicates a line/area is open with spline
line type.
<Begin Area:> User input Opens a new area when the next point is
stored. Any areas which are currently
open are closed. The point may or may
not be stored with a point code.
<ReOpen Last Area:> Opens the last used area again.
<Close Area:> User input Closes all open areas.
Next step
CONT (F1) returns to the screen from where CONFIGURE Coding & Linework was
accessed.
TPS1200+ Config...\Survey Settings...
17.4 Offsets
Description
Diagram
Lë
Access
CONFIGURE
Offsets
Offsets can be configured and entered. The offset values are applied to measured
points. The Offset function allows offset points to be determined, for instance when
the reflector cannot be set up directly on a point. Transverse, longitudinal and/or
elevation offsets can be defined from the reflector position to the offset point. All of
the displayed and recorded measurement data is in relation to the offset point.
PO Station
P1 Current position
P2 Offset point
P3 Offset point
d1 Offset cross -
d2 Offset cross +
d3 Offset length -
d4 Offset length +
J d5 Offset height -
TPS12_041 d6 Offset height +
If configured in a display mask, the offset values appear also in the display mask in
Survey.
Select Main Menu: Config...\Survey Settings...\Offsets.
17:00 IR E RI
CONFIGURE Fel a Les
Offset Hode ` WT LATE TT An
Offset Cross : 0.000 n
Offset Length: 0.000 n
Offset Height: 0.000 a CONT (F1)
To accept changes and return to the
screen from where this screen was
accessed.
uzat OFS=0 (F5)
CONT | | | | OFS=0| | To set all offsets to 0.000.
Description of fields
Field Option Description
<Offset Mode:> Reset after REC | The offset values are reset to 0.000 after
a point is measured with REC (F3) or ALL
(F1).
Permanent The offset values are applied to every
measured point until reset or changed.
Config...\Survey Settings... TPS1200+ 97
98
Field Option
Description
<Offset Cross:> / User input
Sets cross offset of target point, perpen-
dicular to the line of sight.
<Offset Length:> | User input
Sets length offset of target point, in the
direction of the line of sight.
<Offset Height:> | User input
Sets height offset of target point.
Next step
CONT (F1) returns to the screen from where CONFIGURE Offsets was accessed.
TPS1200+
Config...\Survey Settings...
18 Config...\Instrument Settings...
18.1 EDM & ATR Settings
Description
Lë
Access
CONFIGURE
EDM & ATR
Settings
Survey page
Setup page
The settings on this screen define the active EDM Electronic Distance Measurement
and ATR Automatic Target Recognition settings.
Descriptions apply in general to TPS1200+ instruments. Available options depend
on the purchased model, for example with or without ATR.
Select Main Menu: Config...\instrument Settings...\EDM & ATR Settings.
Description
e This screen has two pages - the Survey page and the Setup page.
e The Survey page and Setup page contain identical fields.
e The settings made in the Survey page are used by all applications and all meas-
urements taken outside of the Setup application program.
e The settings made in the Setup page are only used inside the Setup application
program.
e Any changes made to the EDM & ATR Settings (e.g. via Icons, Quick Set,
Hotkeys) while the Setup application program is active, only affect the Setup
EDM & ATR settings.
e Any changes made to the EDM & ATR Settings (e.g. via Icons, Quick Set,
Hotkeys) while the Setup application program is not active, only affect the
Survey EDM & ATR settings.
e When entering the Setup application program, the Setup EDM & ATR Settings
are active.
e When leaving the Setup application program, the Survey EDM & ATR Settings
are active.
e Both Survey and Setup EDM & ATR Settings are part of the configuration sets.
Diagram
17:43 IR e H
CONFIGURE + & en L H Reo g
EDN & ATR Settings x
Survey | Seti
EDH Type Reflector (IR)MQ
EDH Hode Standard du
CONT (F1)
Reflector : Leica Cire Prism +| To accept changes and return to
Add. Constant: =e TPS1200+ Main Menu.
Automation : ATR 4+ TEST (F4)
ATR Settings : Norma 4
uža f To access the CONFIGURE EDM
CONT | | | TEST | | PAGE | Test Signal/Frequency screen.
Config...\Instrument Settings... TPS1200+ 99
100
Description of fields
Field
<EDM Type:>
Option
Reflector (IR)
Refictrless (RL)
Long Range (LO)
Description
All fields are set to the last used
options.
The IR EDM exists for all instrument
types and allows to measure the
distance to a prism or a tape. IR is the
EDM that can be used with ATR and
LOCK. For <Automation: ATR> or
<Automation: LOCK> <EDM Type:
Reflector (IR)> is automatically set.
Whenever <EDM Type: Reflector
(IR)> is selected, the last setting for
<Automation:> which was used with
reflector is set.
When activated, IR is displayed.
<Automation: None> and
<Reflector: Reflectorless> are
selected. The other fields are set to
the last used options.
When activated, RL is displayed.
<Automation: None> is selected.
Last used options are reset for the
other fields.
When activated, LO is displayed.
<EDM Mode:>
Standard
Fast
Tracking
SynchroTrack
TPS1200+
Available for all <EDM Type:>
options. Standard single distance
measurement.
When activated, STD is displayed.
Available for <EDM Type: Reflector
(IR)>. Fast single distance measure-
ment.
When activated, FAST is displayed.
Available unless <EDM Type: Long
Range (LO)>. Continuous distance
measurement. The measured
distances can be stored anytime with
REC (F3).
When activated, TRK is displayed.
Available only for <EDM Type:
Reflector (IR)>.
Config...\Instrument Settings...
Field
<AVG Max #Dist:>
<Reflector:>
<Add. Constant:>
<Automation:>
Option
Average
User input
Choicelist
Output
None
ATR
LOCK
Description
e This is the measurement mode for the
interpolation of angle measurements
in IR LOCK Tracking mode. In differ-
ence to normal IR LOCK Tracking
mode, where angle measurements
are only assigned to certain distance
measurements, SynchroTrack will
perform a linear interpolation
between the previous and following
angle measurement, based upon the
timestamp of the EDM measurement.
e When activated, SYNC is displayed.
e Available for all <EDM Type:>
options. Repeats measurements in
standard measuring mode. The
average distance of <AVG Max
#Dist:> and the standard deviation
for the averaged distance are calcu-
lated.
e When activated, AVG is displayed.
Available if <EDM Mode: Average>.
Input field for the maximum number of
distances to be averaged from 2 to 999
distances.
Reflector names as configured in Main
Menu: Manage...\Reflectors.
The additive constant stored with the
chosen reflector.
Measurements are done without ATR.
Positioning to static prisms.
Unavailable for SmartStation. The instru-
ment locks onto and follows the moving
prism.
<ATR Settings:>
Config...\iInstrument Settings...
Choicelist
Normal
Low Vis On
TPS1200+
e ATR Settings.
e Normal Mode is turned on.
e Low Visability Mode is turned on. To
increase the instrument measuring
ability during suboptimal weather
conditions. Available only when ATR
or LOCK mode is activated.
101
102
Field
Option
Description
Low Vis Always
On
S-Range On
S-Range Always
On
This mode is automatically deacti-
vated when the instrument is turned
off.
This mode has a considerable influ-
ence on the range (restriction to 100-
150 m).
Low Visability Mode is permanently
turned on.
Short Range Mode is turned on.
This mode is designed for survey
work at close range from the instru-
ment (up to 60-80 m). Under these
conditions the instrument LOCK
Mode is significantly stabilised.
This mode is automatically deacti-
vated when the instrument is turned
off.
Short Range Mode is permanently
turned on.
Next step
CONT (F1) returns to TPS1200+ Main Menu.
TPS1200+
Config...\Instrument Settings...
18.2 Search Windows
Description
Access
CONFIGURE
Search Windows,
PS Window page
The settings on this screen define the size of search windows for prisms to be
searched in. The prisms can be searched with ATR in the ATR window or with
PowerSearch in the PS window.
Select Main Menu: Config...\iInstrument Settings...\Search Windows.
17:03 Ter moe vi CONT (F1)
CONFIGURE sp LN Bice To accept changes and return to
Search Windows E
Search Windows
IPS Wand
x :
a SS TPS1200+ Main Menu.
PS Window TT NEW (F2)
Hz left . 0g To define new PowerSearch window.
Hz right i 0 g CENTR (F4)
Y upper 100 o To centre the PowerSearch window
V lower i UA to the current position of the tele-
Dist min : Hin dp
Dist max : Uri DEE
[G2aq SHOW (F5)
CONT | NEW | |CENTR| SHOW | PAGE | To position the telescope to corners
of PowerSearch window.
Description of fields
Field Option Description
<PS Window:> On PowerSearch searches in the defined
window.
Off PowerSearch searches from 0° to 360°
within +20 gon from horizon.
<Hz left:> Output The left, right, upper and lower boundaries
<Hz right:> of the PowerSearch window.
<V upper:>
<V lower:>
<Dist min:> Min and from Minimum distance of the search range for
25 m to 175m the PS window to be defined.
<Dist max:> From 25 m to Maximum distance of the search range for
175 m and Max |the PS window to be defined.
Next step
PAGE (F6) changes to the ATR Window page.
Config...\Instrument Settings... TPS1200+ 103
CONFIGURE 17:04 IR SZ spe Bi
Search Windows, CONFIGURE +e en L H sio A
. Search Windows x
ATR Window page ` Ges ATR Winrinn|
Define Size of ATR Window CONT (F1)
To accept changes and return to
EE f TPS1200+ Main Menu.
DEFLT (F5)
To recall the default ATR window
settings.
azar PAGE (F6)
CONT | | | |DEFLT| PAGE | To change to other page on screen.
Description of fields
Field Option Description
<Hz Search:> User input Horizontal extent of window.
<V Search:> User input Vertical extent of window.
Next step
CONT (F1) returns to TPS1200+ Main Menu.
104 TPS1200+ Config...\Instrument Settings...
18.3 Automatic Prism Search
Description
Access
CONFIGURE
Automatic Prism
Search
The settings on this screen define the behaviour of automatic prism search after the
target is lost in lock mode.
Select Main Menu: Config...\Instrument Settings...\Automatic Prism Search.
(Gm d SC 0” RI
CONFIGURE Le" STD nice @
Automatic Prism sod
After Prism is Last
Predict for : 3 shld
After Prediction
search with : No Search dl CONT (F1)
To accept changes and return to
TPS1200+ Main Menu.
uzar DEFLT (F5)
CONT | | | | DEFLT| | To recall the default settings.
Description of fields
Field Option Description
<Predict for:> From1sto5s If the target is lost when <Automation:
LOCK? the path of the reflector is
predicted for the selected amount of
seconds.
<Search with:> No Search, ATR, | Perform no search after prediction, search
PowerSearch or | with ATR in a dynamic ATR window,
Last Point search with PowerSearch or, if the target
is lost when <Automation: LOCK>, then
turn back to the last stored point. For <PS
Window: On> search in PS window and
for <PS Window: Off> search in dynamic
PS window.
Next step
CONT (F1) closes the screen and returns to TPS1200+ Main Menu.
Config...\Instrument Settings... TPS1200+ 105
18.4 TPS Corrections
Description The settings on this screen define the atmospheric ppm, the geometric ppm and the
refraction. The geometric ppm can also be determined by a resection calculation.
For standard application programs the distance is corrected on account of atmos-
pheric influences. The geometrical correction and the projection distortions are set
to 0.00. Heights are reduced with the standard refraction coefficient.
Access Select Main Menu: Config...\instrument Settings...\TPS Corrections.
CONFIGURE 17: 06 +e IR I $ De ch CONT (F1)
TPS Corrections, CONFIGURE STD ¥ Bicg To accept changes and return to
TPS Corrections :
AtmosPPM page breet | Pe TPS1200+ Main Menu.
Temperature "E P<>E (F3)
Atm Pressure : 1013.3 mbar To change <Atm Pressure:> to
Rel Humidity : 60.0 t
<Elev above MSL:> and back.
Atmospheric ppm: o.0 A%<>T ’ (F4)
To change <Rel Humidity:> to
<Temp Wet-bulb:> and back.
muzar PPM=0 (F5)
CONT | | Best |%<>T'|PPH=0| PAGE | To set <Atmospheric ppm: 0.0>.
Description of fields
Field Option Description
<Temperature:> User input Sets the temperature.
<Atm Pressure:> or | User input Sets the atmospheric pressure or the
<Elev above MSL:> elevation above mean sea level
dependent on selection.
<Rel Humidity:> or | User input Sets the relative air humidity or the wet
<Temp Wet-bulb:> bulb temperature dependent on selection.
<Atmospheric User input or The atmospheric ppm is either set or
ppm:> Output calculated from the above values.
Next step
PAGE (F6) changes to the GeomPPM page.
CONFIGURE e The geometric distance correction (geometric ppm) is derived from the map
TPS Corrections, projection distortion (map projection ppm), the height above reference datum
GeomPPM page correction (height ppm) and an individual correction (individual ppm).
e The calculation of the map projection ppm follows the formula for the Trans-
versal Mercator Projection. The individual factors are: the scale factor of the line
of projection central meridian, Gauss-Kruger = 1.0, UTM = 0.9996, etc. and the
offset from the line of projection.
e The calculation of the height ppm is derived from the height of the instrument
station above the reference datum. Normally this is the height above mean sea
level MSL.
106 TPS1200+ Config...\Instrument Settings...
Description of fields
Field
<Calc Scale:>
Option
Choicelist
Manually
Automatically
Description
To manually or automatically calculate
the geometric ppm value.
The geometric ppm value is manually
calculated.
The geometric ppm value is automatically
calculated.
<Individual ppm:> | User input
<Scale at C.M.:> "User input Sets scale at central meridian.
Available when <Calc Scale: Manually>.
<Offset to C.M.:> | User input Sets offset to central meridian.
Available when <Calc Scale: Manually>.
<Map Proj ppm:> | Output The ppm for the map projection.
<Ht above Ref:> User input Sets the height above reference.
Available when <Calc Scale: Manually>.
<ppm above Ref:> | Output The ppm above reference.
Available when <Calc Scale: Manually>.
<Height ppm:> Output The height ppm value calculated from the
height coordinates of the current TPS
station stored in the System RAM. If this
value cannot be calculated, then ----- is
displayed and is also ignored in the calcu-
lation of the geometric ppm value.
Available for Calc Scale: Automatically
Sets the individual ppm.
Available when <Calc Scale: Manually>.
Next step
<Geometric ppm:> | Output
The geometric ppm is the sum of:
<Map Proj ppm:>,
<ppm above Ref:> and
<Individual ppm:>.
PAGE (F6) changes to the Refraction page.
CONFIGURE
TPS Corrections,
Refraction page
difference.
Description of fields
The refraction correction is taken into account during the calculation of the height
Config...\Instrument Settings...
Field Option Description
<Correction:> On or Off Refraction correction is applied to meas-
urements.
<Ref coeff (k):> | User input Available if <Correction: On>. Refraction
coefficient to be used for calculation.
TPS1200+ 107
Next step
CONT (F1) returns to the screen from where CONFIGURE TPS Corrections was
accessed.
108 TPS1200+ Config...\Instrument Settings...
18.5 Compensator
Description
Access
CONFIGURE
Compensator
The compensator and the Hz correction can be deactivated if raw data is to be
displayed and recorded.
Select Main Menu: Config...\iInstrument Settings...\Compensator.
47:09 | p "e RI
CONFIGURE Le: STD Bic g
Compensator x
Compensator : iT ‘|
Hz-Correction: On d
CONT (F1)
To accept changes and return to
uzat
CONT | | | | | | TPS1200+ Main Menu.
Next step
CONT (F1) returns to TPS1200+ Main Menu.
Config...\Instrument Settings... TPS1200+
109
18.6 Instrument ID
Description
Access
CONFIGURE
Instrument ID
110
The settings on this screen define the instrument identification number. This number
is used for the generation of the file names. Using format files, the instrument ID can
be output together with data from the instrument. By doing so, it can be identified
which instrument was used for certain measurements.
Select Main Menu: Config...\instrument Settings...\iInstrument ID.
Description of fields
Field
Option
<Instrument ID:> | User input
Next step
Description
Sets a four digit number as instrument
identification number. By default the last
four numbers of the serial number are
used.
CONT (F1) returns to TPS1200+ Main Menu.
TPS1200+
Config...\Instrument Settings...
18.7
Description
Access
CONFIGURE
Telescope Acces-
sories,
Hz Limit page
CONFIGURE
Telescope Acces-
sories,
V Limit page
Config...\iInstrument Settings...
Telescope Accessories
The settings on this screen offer the possibility to limit the motorization to a certain
part of the horizontal and/or vertical circle as used telescope and lens accessories
may obstruct a full rotation of the telescope. General positioning functions are then
restricted to these boundaries.
Select Main Menu: Config...\iInstrument Settings...\Telescope Accessories.
17:41 £ "e RI
CONFIGURE ar STD D
E
Telescope Shere
Hz | imiti | imit
CONT (F1)
To accept changes and return to
Hz Begin Dron" oo" TPS1200+ Main Menu.
Hz End 90°00'00" NEW (F2)
Use Limit ER ‘| To define new horizontal limits for
instrument rotation.
SHOW (F5)
To position the instrument to the left
and right limit of instrument turning.
[ at
CONT | NEW | | | SHOW | PAGE |
Description of fields
Field Option Description
<Hz Begin:> Output/User input | The left and right boundaries of the
<Hz End:> window within the instrument is allowed to
turn.
<Use Limit:> Yes Instrument turning is restricted to the
defined window.
No Instrument rotates without any limitation,
from 0 to 400 gon.
Next step
PAGE (F6) returns to the V Limit page.
A7:4i
| $ e E
CONFIGURE cei s l Gen
SE
Telescope Accessories ` E
WoL imit
CONT (F1)
To accept changes and return to
Eyepiece Accessories
Y Begin AB°OO'OO" TPS1200+ Main Menu.
¥ End 135°00'00" NEW (F2)
Lens Accessories er To define new vertical limits for tele-
: a Ee scope rotation.
SHOW (F5)
Use Limit a | Ss ,
CH To position the telescope to its rota-
CONT | NEW | | | SHOW | PAGE | tion limits.
TPS1200+ 111
112
Description of fields
Field Option
Description
<V Begin:> Output/User input
<V End:>
Vertical extent of the window in which the
instrument is allowed to turn the tele-
scope. The value of the current limit refers
to the vertical reading of the present line
of sight direction.
<Use Limit:> None
Eyepiece
Lens
Eyepce & Lens
Telescope turns without any limita-
tion,from O to 400 gon.
The movement of the telescope is limited
by the stored Eyepiece Accessories
Limits.
The movement of the telescope is limited
by the stored Lens Accessories Limits.
The movement of the telescope is limited
by the combination of both areas with the
least vertical extend.
Next step
CONT (F1) returns to TPS1200+ Main Menu.
TPS1200+
Config...\Instrument Settings...
19 Config...\General Settings...
19.1 Wizard Mode
Description
Access
CONFIGURE
Wizard Mode
The settings on this screen define the behaviour of the configuration set wizard.
Select Main Menu: Config...\General Settings...\Wizard Mode.
17:17 IR $ = Ow Bi
CONFIGURE SCH se et" Ric #
Hizard Hode
Wizard Hode - BBS wired gta DE AN
CONT (F1)
To accept changes and to return to
TPS1200+ Main Menu.
LIST (F6)
Lists all screens within a configura-
GEERT tion set. Allows to access these indi-
CONT | | | | | LIST | vidual screens and change settings.
Description of fields
Field Option Description
<Wizard Mode:> |View All Screens | All configuration screens are shown in the
configuration set wizard. Application
program configuration screens are not
included. They can be configured within
each application program.
Reduced A reduced set of screens are shown in the
configuration set wizard.
Next step
CONT (F1) returns to TPS1200+ Main Menu.
Config...\General Settings... TPS1200+ 113
19.2 Hot Keys & User Menu
Description
Access
Configuring
Hot Keys
Configuring
Shift Hot Keys
114
e The settings on this screen assign a particular function, screen or application
program to each of the first and second level of hot keys and to the USER key.
e Refer to "2 Configurable Keys" for further details.
Select Main Menu: Config...\General Settings...\Hot Keys User Menu.
For TPS1200+:
17:47 IR E > e ED
CONFIGURE Oe STD I K Bos
Hot Keys & User Hen x]
Hot Keys |Shift Ant Kewvslllsaer Menu] |
Ff: FUNC Select Free Codell
F8 : NGHT Data f
FQ : HGHT Reflectors d
F10: FUNC ATR On/Off dr CONTAFT)
F44: FUNC EDH EE To accept changes and to return to
F42: FUNC Power Search: TPS1200+ Main Menu.
mar DEFLT (F5)
CONT | | | |DEFLT| PAGE | To recall the default settings.
Description of fields
Field Option Description
<F7:> to <F12:> Choicelist All functions, screens or application
programs which can be assigned to the
particular key.
13:56 IR $ ~ e RI
CONFIGURE + & ml H Be g
Hot Keys & User Henu
Hot Keys|Shift Hot Keys Hleer Menu
Fi : FUNC Enter Free Code
F8 : HGHT Data Log dr
F9 : STAT Station Information 4}
NW UNC Quick seau CONT (F1)
ee To accept changes and to return to
F TPS1200+ Main Menu.
mza DEFLT (F5)
CONT | | | |DEFLT| PAGE | To recall the default settings.
Description of fields
Field Option Description
<F7:> to <F10:> Choicelist All functions, screens or application
programs which can be assigned to the
particular key.
TPS1200+ Config...\General Settings...
Field Option Description
<F11:> Output The lights, display, beeps and text
settings can be edited.
<F12:> Output The electronic level is displayed.
Configuring 1357
User Menu CONFIGURE ap i STO
HEHT Data fH
CONF TPS Correetions 4
CONF EDH & ATR Settings dr
FUNC Check Recorded Point d
FUNC EDH Test di
IHPT Data to Job +f
CONT (F1)
To accept changes and to return to
EXPT Data From Job die TPS1200+ Main Menu.
uża q DEFLT (F5)
CONT | | | |DEFLT| PAGE | To recall the default settings.
ris bali baal maaan
Description of fields
Field Option Description
<1:> to <9:> Choicelist All functions, screens or application
programs which can be assigned to the
individual lines in the user defined menu.
Config...\General Settings... TPS1200+ 115
19.3
Description
Access
CONFIGURE
Units & Formats,
Units page
116
Units & Formats
The settings on this screen define:
e the units for all types of measurement data displayed.
e information related to some types of measurement data.
e the order in which coordinates are displayed.
Select Main Menu: Config...\General Settings...\Units & Formats.
Description of fields
Field
<Distance Unit:>
<Distance Dec:>
<Angle Unit:>
<Angle Dec:>
Option
Metre (m),
Int Ft (fi),
Int Ft/Inch (fi),
US Ft (ft) or
US Ft/Inch (ft)
From 0 Decimal
to 4 Decimals
400 gon,
360 °°",
360° dec or
6400 mil
From 2 Decimals
to 4 Decimals
From 1 Decimal
to 3 Decimals
Description
The units shown for all distance and coor-
dinate related fields.
The number of decimal places shown for
all distance and coordinate related fields.
This is for data display and does not apply
to data export or storage.
The units shown for all angular and coor-
dinate related fields. More angle settings
can be defined on the Angle page.
The number of decimal places shown for
all angular and coordinate related fields.
This is for data display and does not apply
to data export or storage.
Available for <Angle Unit: 400 gon> or
<Angle Unit: 360° dec>.
Available for <Angle Unit: 6400 mil>.
% (v/h * 100)
Elev Angle
TPS1200+
4 Decimals Available for <Angle Unit: 6400 mil>.
5 Decimals Available for <Angle Unit: 400 gon> or
<Angle Unit: 360° dec>.
0.1”, 1”, 5”, 10”, | Available for <Angle Unit: 360 °’ ’’>.
60”
<Grade Unit:> The input and output format for grades.
h:v Horizontal by vertical distance.
v:h Vertical by horizontal distance.
Percentage of vertical by horizontal
distance.
Elevation angle.
Config...\General Settings...
CONFIGURE
Units & Formats,
Angle page
CONFIGURE
Units & Formats,
Time page
Field
Option
Description
<Area Unit:>
m2,
Int Acres (Ai),
US Acres (A),
Hectares (ha),
fi? or ft?
The units shown for all area related fields.
<Volume Units:>
m, fi’, ft? or yd?
The units shown for volume related fields.
<Temp Unit:>
Celsius (°C) or
Fahrenheit (°F)
The units shown for all temperature
related fields.
<Press Unit:>
Next step
mbar, mmHg,
Inch Hg (inHg),
hPa or psi
PAGE (F6) changes to the Angle page.
Description of fields
The units shown for all pressure related
fields.
psi = pounds per square inch.
Field
<Direc Ref:>
Option
North Azimuth,
South Azimuth,
North Anticlock,
Description
Sets the reference direction as well as the
direction from where and how azimuths
are computed.
or Bearing
<V-Display:> Zenith Angle, Sets the vertical angle.
Elev Angle or
Elev Angle %
<V-Angle:> Hold after DIST or | The vertical angle is fixed or continuously
Running updated with the telescope movement
after a distance measurement with DIST
(F2).
<Face I:> Hz-Drive Right or | Horizontal drive on the right or left side.
Hz-Drive Left
Next step
PAGE (F6) changes to the Time page.
Description of fields
Field Option Description
<Time Format:> |24 hour or 12 hour | How the time is shown in all time related
(am/pm) fields.
<Time:> User input Time, displayed with format hh:mm:ss
TPS1200+ 117
Config...\General Settings...
CONFIGURE
Units & Formats,
Format page
118
Field Option Description
<Date Format:> |Day.Month.Year, | How the date is shown in all date related
Month/Day/Year | fields.
or
Year/Month/Day
<Date:> User input Date, displayed with format dd:mm:yy
Next step
PAGE (F6) changes to the Format page.
Description of fields
Field Option Description
<Grid Format:> East North or The order in which grid coordinates are
North,East shown in all screens. The order in display
masks depends on the user settings.
<Geodetic Lat,Long or The order in which geodetic coordinates
Format:> Long,Lat are shown in all screens. The order in
display masks depends on the user
settings.
Next step
PAGE (F6) changes to the first page on this screen.
TPS1200+ Config...\General Settings...
19.4 Language
Description
Access
CONFIGURE
Languages on
Instrument
The setting on this screen defines the language used on the instrument. Three
languages can be stored on the instrument at one time - English and two others.
English cannot be deleted.
Select Main Menu: Config...\General Settings...\Language.
Description of columns
Column Description
Language The languages available on the instrument. The selected
language is used for the system software. If a language is not
available for the system software, the English language is
used instead. Application programs run in the language they
were loaded.
Next step
CONT (F1) returns to TPS1200+ Main Menu.
Config...\General Settings... TPS1200+ 119
19.5 Lights, Display, Beeps, Text
Description
Access
CONFIGURE
Lights, Display,
Beeps, Text,
Lights page
CONFIGURE
Lights, Display,
Beeps, Text,
Display page
120
The settings on this screen allow the screen appearance to be configured, turn the
notification beeps on and off and define the behaviour of the keys.
Select Main Menu: Config...\General Settings..\Lights, Display, Beeps, Text
OR
Press SHIFT F11.
Description of fields
Field Option Description
<Redlaser:> To turn the redlaser of RL EDM on and off.
<EGL:> To turn the Emitting Guide Light (EGL) on and
off. This field is only available if EGL is fitted
<Laser Guide:> | On or Off To turn the Laser Guide (GUS74) on and off.
This field is only available if GUS74 is fitted
<Intensity:> From 0 % to To adjust the EGL/Laser Guide intensity using
100 % the left and right arrow keys.
<Reticule:> On or Off To turn the reticule illumination on and off.
<Intensity:> From 0 % to To adjust the reticule illumination intensity
100 % using the left and right arrow keys.
Next step
PAGE (F6) changes to the Display page.
This page contains the screen display settings for the TPS1200+ instrument.
Description of fields
Field Option Description
<Touch Screen:> | On or Off Turns touch screen on and off.
<Screen Beep:> | Off, Soft or Controls the beep upon touching the touch
Loud screen.
<Screen Illum:> | Always On, Controls the screen illumination to be on, or
On for 1 min, (on for the specified time after the last key
On for 2 min or | Was pressed, or touch screen event.
On for 5 min
<Key Illum:> Off, Same as | Controls the keyboard illumination.
Screen or
Always On
<Brightness:> From 1 to 5 To adjust the screen brightness.
Next step
PAGE (F6) changes to the Beeps page.
TPS1200+ Config...\General Settings...
CONFIGURE
Lights, Display,
Beeps, Text,
Beeps page
CONFIGURE
Lights, Display,
Beeps, Text,
Text page
Description of fields
Field Option Description
<Warning Beeps:> |Off, Soft or Controls the beep for acoustic warning
Loud signals for the instrument.
<WarnBeeps RCS:> | Off, Soft or Controls the beep for acoustic warning
Loud signals for the RX1200 controller.
<Key Beeps:> Off, Soft or Controls the beep upon key presses for
Loud the TPS1200+instrument.
<Key Beeps RCS:> | Off, Soft or Controls the beep upon key presses for
Loud the RX1200 controller.
<Hz-Sectr Beep:> On or Off Turns the Hz-sector beep on and off. The
instrument beeps when within 5 gon/4°30’
of the defined sector, there is a long and
consistent beep within 0.5 gon/27’ and no
beep within 0.005 gon/16”.
<Sector Angle:> User input Input field for sector angle for which a beep
should sound.
Next step
PAGE (F6) changes to the Text page.
Description of fields
Field Option Description
<Key Rpt Delay:> User input Key repeat delay is the time between the
initial Key press and when the key starts
repeating. For example in numeric mode
press and hold 1. Behaviour on screen: 1
- delay - 11111111111.
<Alpha Mode:> Function Keys | Alphanumeric input can either be through
or Numeric function or numeric keys.
Keys
<Deflit aNum:> Choicelist Available if <Alpha Mode: Function
Keys>. Sets the set of extra characters
available through aNUM or on F1-F6
whenever an entry is made. The choices
available depend on the character sets
loaded on the instrument and the
language configured to be used on the
instrument.
Next step
PAGE (F6) changes to one of the other pages.
Config...\General Settings... TPS1200+ 121
19.6
Description
Access
CONFIGURE
Start Up & Power
Down
Start Up & Power
Down
page
122
Start Up & Power Down
e The settings on this screen:
e define the behaviour of the instrument for a general start up.
e define the behaviour of the instrument when starting up after a power loss.
e define a PIN code which needs to be typed in on starting up the instrument. A
PIN is a Personal Identification Number.
Select Main Menu: Config...\General Settings...\Start Up & Power Down.
Description of fields
Field Option Description
General settings
<Start Screen:> | Choicelist Determines the first screen which is
shown after turning on the instrument.
<Power Down:> | With Sets the behaviour of the instrument shut
Auto Power Down Behaviour settings
<Mode:>
<After Time:>
Confirmation or
Directly
Turn Off or
Remain On
User input
SmartAntenna settings
<Switch Off:>
Power settings for
<Switch On:>
Next step
Choicelist
Device on Port 2
If Device Found
If ATX Found
down.
The instrument turns off or does not
power down if no events have occurred.
Available unless <Mode: Remain On> is
selected. Minutes after which the instru-
ment should turn off.
This option determines when Smart-
Antenna is turned off. The selected time is
activated whenever SmartStation leaves
GPS mode.
This option is directly linked to <Switch
Off:> in CONFIGURE Logging of Raw
Obs. Refer to "23.6 Logging of Raw Obs"
for details.
Devices attached to port 2 are automati-
cally powered up.
SmartAntenna attached to port 2 is auto-
matically powered up.
CONT (F1) changes to the PIN Code page.
TPS1200+
Config...\General Settings...
CONFIGURE Whenever this screen is accessed the appearance of the screen varies, depending
Start Up & Power on the setting for <Use PIN:>
Down <Use PIN: No> <Use PIN: Yes>
PIN Code 07:39 T w 07:39 =,
N I $ e E fos Le I $ e WI
page CONFIGURE STD 7 D e Zë CONFIGURE STO k D vA
Start Up & Power Down E’@Start Up & Power Down x
Start Ip & Power Ten (DIN Tode & Power Top (DTN Tode
Use PIN CDJ PIN Code
Use PIN : Yos dl
Change PIN S No d
Uzat Uzat
CONT | | | | | PAGE | CONT | | | | | PAGE |
Description of fields
Field Option Description
Use PIN Yes or No Activates the PIN code protection. This
setting is not part of the configuration set.
New PIN User input The PIN code must be a number with four
to six digits.
PIN Code User input The PIN code as previously defined on
this page. The correct PIN code must be
typed in within five attempts or the PUK
code is required.
Change PIN Yes or No Activates <New PIN:> to type in a new
PIN code.
Next step
PAGE (F6) changes to the first page on this screen.
Config...\General Settings... TPS1200+ 123
124 TPS1200+ Config...\General Settings...
20 Interfaces, Ports, Devices
20.1 Interfaces
20.1.1 Overview of Interfaces
Description e The instrument has various interfaces configured to to be used with a port and
a device. The configuration varies depending on the individual application.
e Additional interfaces are always available when the instrument is fitted with
Communication side cover. Communication side cover is used by RadioHandle
with RCS and by SmartAntenna Adapter with SmartStation.
Available TPS1200+ TPS1200+
interfaces without Communication side cover with Communication Se cover
08:10 Ss e BM] 11:38 z e Wi
CONFIGURE a cke STD CONFIGURE AE cke STD
Bo D Bo SL
Interfaces Kä Kä
Tnterfare T Newice
GSI Output
GeoC OH Hode
RCS Hode
Export Job
Interfaces
Tntertare S Newice
GSI Output
- GeoCOH Hode
RCS Hode
Export Job
GPS RTK
Internet
Uzat
CONT | | EDIT | CTRL | USE m Hik CONT | | EDIT | CTRL | USE | |
Interfaces, Ports, Devices TPS1200+ 125
20.1.2 Configuring an Interface
Access
CONFIGURE
Interfaces
126
Select Main Menu: Config...\Interfaces....
08:08 $} > Bl
CONFIGURE +@%, I K o oe CONT (F1)
Interfaces - - G To return to the screen from where
ntarfarce Dewi re
GSI Output this screen was accessed.
GooC0N Hode EDIT (F3)
To configure the parameters related
. to the highlighted interface.
- CTRL (F4)
Available for certain devices
DECK connected to certain interfaces. To
CONT | | EDIT | CTRL | USE | | configure additional paramaters.
USE (F5)
To turn the selected interface on/off.
Export Job
GPS RTK
Internet
TPS1200+ Interfaces, Ports, Devices
20.2 Ports
Description e The instrument is always fitted with the port located at the instrument base (port
1). Additional ports are available when Communication side cover is fitted (port
2 and port 3).
e The list of available devices always depends on the selected port.
Available ports Type
TPS1200+ without Port TPS1200+ with
Communication side cover Communication side cover
5 pin LEMO-0 Port 1 For TPS1200+: 5 pin LEMO-0
for power and/or communication for power and/or communication
not applicable Port 2 Hotshoe connection for
(Handle) | RadioHandle with RCS and
SmartAntenna Adapter with
SmartStation
not applicable Port 3 (BT) | Bluetooth module for
communication with only
Bluetooth capable devices.
Location
Port Description
Port 1 This port is located at the base of the instrument and is always
available.
Port 2 (Handle) This port is located on top of Communication side cover.
Port 3 (BT) This port is housed within Communication side cover.
Interfaces, Ports, Devices TPS1200+ 127
20.3 Devices
20.3.1 Overview of Devices
Description e A device is the hardware which is connected to the chosen port. Devices are
used to transmit and receive measurement data in TPS mode and GPS real-time
data in GPS mode. Devices are also used by TPS1200+ to communicate with
the RX1200 controller.
e Before using any device with TPS1200+ it is necessary to configure it and the
interface with which it will be used.
e Refer to "20.1.2 Configuring an Interface" for information on how to configure
interfaces.
e Refer to "20.3.2 Configuring a Device" for information on how to create, edit,
select and delete devices.
e Refer to "20.3.3 Controlling a Device" for information on how to configure
additional device parameters.
e Some devices may be used with different interfaces for different applications.
For example, a radio can be used for remote control with TPS1200+ but also to
send GeoCOM commands from a computer to TPS1200+.
128 TPS1200+ Interfaces, Ports, Devices
20.3.2 Configuring a Device
Description Allows devices to be created, edited, selected and deleted.
Access Step
step-by-step
Description
1.
2.
Main Menu: Config...\Interfaces... to access CONFIGURE Interfaces.
Highlight the appropriate interface based on the type of device that needs
to be configured. For example, highlight RCS Mode when a radio is to be
configured.
Interfaces, Ports, Devices
EDIT (F3) to access CONFIGURE XX.
DEVCE (F5) to access CONFIGURE Devices.
TPS1200+ 129
20.3.3 Controlling a Device
Description Allows additional device parameters to be configured.
Access Step
Description
step-by-step
1.
2:
Main Menu: Config...\Interfaces... to access CONFIGURE Interfaces.
Highlight the appropriate interface based on the type of device that needs
to be configured. For example, highlight RCS Mode when a radio is to be
configured.
CTRL (F4) to access CONFIGURE XX.
130
TPS1200+ Interfaces, Ports, Devices
20.3.4 Creating a New Device/Editing a Device
Access Step |Description
step-by-step
1. Refer to "20.3.2 Configuring a Device" to access CONFIGURE Devices.
2. Highlight a device of the same type as the device to be created, from the
list.
3. NEW (F2)/EDIT (F3) to access CONFIGURE New Device/CONFIGURE
Edit Device.
LE Editing a device is similar to creating a new device. For simplicity, the screens are
called CONFIGURE XX Device and differences are clearly outlined.
CONFIGURE Description of fields
XX Device
Field Option Description
<Name:> User input Available when creating a new device.
The name of the device.
Output Available when editing a device. The
name of the device.
<Type:> Output The type of device
<GRPS/ Yes or No Available for digital cellular phones and
Internet:> modems. Defines the device as an
Internet capable device and adds it to the
list in CONFIGURE GPRS Internet
Devices.
<Baud Rate:>
From 2400 to
Frequency of data transfer from instru-
Interfaces, Ports, Devices
115200 ment to device in bits per second.
<Parity:> None, Odd or Error checksum at the end of a block of
Even digital data.
<Terminator:> To define the terminator.
CR/LF The terminator is a carriage return
followed by a line feed.
CR Not available for RS232 GeoCOM and
TCPS27 device. The terminator is a
carriage return.
<Data Bits:> 6,70r8 Number of bits in a block of digital data.
<Stop Bits:> 1or2 Number of bits at the end of a block of
digital data.
<Flow Control:> | None or RTS/CTS | Activates hardware handshake.
TPS1200+ 131
Next step
IF the device is a
radio or device other than
digital cellular phone or modem
STORE (F1) to close the screen and to return to
the screen from where CONFIGURE XX Device
was accessed.
digital cellular phone or modem
ATCMD (F4). Refer to paragraph "CONFIGURE
GSM/Modem AT Command Lines".
CONFIGURE
GSM/Modem AT
Command Lines
Description of fields
For <GPRS/Internet: Yes> in CONFIGURE XX Device, this screen consists of two
pages. The following table lists the fields of both pages.
Field Option Description
<Init 1:> User input Initilisation sequence to initilise digital
cellular phone/modem.
<(cont):> User input Allows the <Init X:> or the <Connect:>
string to continue onto a new line.
<Init 2:> User input Initilisation sequence to initilise digital
cellular phone/modem.
<Dial:> User input Dialing string used to dial the phone
number.
<Hangup:> User input Hangup sequence used to end the
network connection.
<Escape:> User input Escape sequence used to switch to the
command mode before using the hangup
sequence.
<Connect:> User input Dialing string used to dial into the Internet.
When the device is used, between <Init 1:> and <Init 2:>, a check for the PIN is
performed.
Next step
Step |Description
1. STORE (F1) returns to CONFIGURE XX Device.
2. STORE (F1) returns to the screen from where CONFIGURE XX Device
was accessed.
132
TPS1200+
Interfaces, Ports, Devices
21 Config...\lInterfaces... - Editing the Interface
21.1 GSI Output
Description
Access
CONFIGURE
GSI Output
Data is stored directly to the RS232 and to the active job. GSI data is stored if <Use
Interface: Yes> and either ALL (F1) or REC (F3) is pressed. The format depends
on the selected option in <GSI Format:>.
Select Main Menu: Config...\Interfaces.... Highlight GSI Output. EDIT (F3).
Description of fields
Field Option Description
<Use Interface:> | Yes or No Activates the interface.
<Port:> Choicelist Available if <Use Interface: Yes>.
Port to be used.
<Device:> Output Available if <Use Interface: Yes>.
Device to be used.
<Protocol:> RS232 GSI or Available if <Use Interface: Yes>.
None Protocol defines if the system expects a
handshake or not.
<GSI Format:> Choicelist Available if <Use Interface: Yes>.
Next step
CONT (F1) returns to the screen from where CONFIGURE GSI Output was
accessed.
Config...\Interfaces... - Editing the
Interface
TPS1200+
133
21.2 GeoCOM Mode
Description
Access
CONFIGURE
GeoCOM Mode
134
The GeoCOM Mode permits communication of the TPS1200+ with a 3 party
device.
Select Main Menu: Config...\Interfaces.... Highlight GeoCOM Mode. EDIT (F3).
Description of fields
Field Option
Description
<Use Interface:> | Yes or No
Activates the interface.
<Port:> Choicelist Available if <Use Interface: Yes>.
Port to be used.
<Device:> Output Available if <Use Interface: Yes>.
Device to be used.
<Protocol:> Output Available if <Use Interface: Yes>.
Protocol to be used.
Next step
CONT (F1) returns to the screen from where CONFIGURE GeoCOM Mode was
accessed.
TPS1200+
Config...\Interfaces... - Editing the
Interface
21.3 RCS Mode
Description RCS stands for Remote Control Surveying. This enables the instrument to be
remotely controlled by an RX1200.
Access Select Main Menu: Config...\Interfaces.... Highlight RCS Mode. EDIT (F3).
CONFIGURE Description of fields
RCS Mode
Field Option Description
<Use Interface:> | Yes or No Activates the interface.
<Port:> Choicelist Available if <Use Interface: Yes>.
Port to be used.
<Device:> Output Available if <Use Interface: Yes>.
Device to be used.
<Protocol:> Output Available if <Use Interface: Yes>.
Protocol to be used.
Next step
CONT (F1) returns to the screen from where CONFIGURE RCS Mode was
accessed.
Config...\Interfaces... - Editing the TPS1200+ 135
Interface
21.4 Export Job
Description
Access
CONFIGURE
Export
Job Interface
136
e The Export Job interface allows data from a job to be exported from the instru-
ment to an external device.
e The settings on this screen define the port and the device to which the data
should be exported.
Select Main Menu: Config...\Interfaces.... Highlight Export Job. EDIT (F3).
The availability of the fields depend on the setting for <Device:>.
Description of fields
Field Option
<Use Device:> Yes or No
<Port:> Choicelist
<Device:> Output
Next step
Description
Activates the interface.
Available if <Use Interface: Yes>.
Port to be used.
The device currently assigned to the
selected port within the active configura-
tion set. The device which is selected
determines the availability of the next
fields.
CONT (F1) returns to the screen from where CONFIGURE Export Job Interface
was accessed.
TPS1200+
Config...\Interfaces... - Editing the
Interface
21.5 GPS RTK
Description e The settings on this screen allow real-time related parameters to be configured.
This includes defining if SmartStation should work as a rover and the real-time
messages to be used.
e Refer to "23.1 Real-Time Mode" for detailed information.
Config...\Interfaces... - Editing the TPS1200+
137
Interface
21.6 Internet
Description
Access
CONFIGURE
Internet Interface
138
The Internet interface:
e allows accessing the Internet using SmartStation and a GMS/Modem device.
e canbe used together with the GPS RTK interface to receive real-time data from
a NTRIPCaster via Internet communication.
Select Main Menu: Config...\Interfaces.... Highlight Internet. EDIT (F3).
Description of fields
Field
Option
Description
<Internet:>
<Port:>
Yes or No
Choicelist
Activates the Internet interface.
Available if <Use Interface: Yes>.
Port to be used.
<Device:>
<IP Address:>
<Set IP Adr:>
<User ID:>
<(cont):>
<Password:>
Next step
Output
Dynamic
Static
User input
User input
User input
User input
Available if <Use Interface: Yes>.
Device to be used.
Each time SmartStation wants to access the
Internet via the device a new IP address is assigned
to the instrument. When using GMS/Modem to
connect to the Internet then the network provider
always dynamically assigns the IP address.
Each time SmartStation wants to access the
Internet via the device the same IP address identi-
fies the instrument. Thsis is important if Smart-
Station is used as a TCP/IP server. This option
should only be selected if a static IP address is avail-
able for SmartStation.
Available for <IP Address: Static>. To set the IP
address.
Some providers ask for a user ID to allow
connecting to the Internet via GMS/Modem. Contact
your provider if a user ID needs to be used.
It is possible to show/hide the User ID.
Refer to "24.5 Licence Keys" for further details.
Allows the <User ID:> string to continue onto a new
line.
Some providers ask for a password to allow
connecting to the Internet via GMS/Modem. Contact
your provider if a password is required.
CONT (F1) returns to the screen from where CONFIGURE Internet Interface was
accessed.
TPS1200+ Config...\Interfaces... - Editing the
Interface
22 Config...\lInterfaces... - Controlling the Device
22.1 Digital Cellular Phones
Description
Access
CONFIGURE
XX Connection
For digital cellular phones, information such as:
e the reference stations that can be contacted
e the phone numbers of the reference stations and
e the type of protocol to be used
can be defined.
Refer to "20.3.3 Controlling a Device" to access CONFIGURE XX Connection.
The name of the screen depends on the type of technology of the digital cellular
phone chosen in CONFIGURE Interfaces.
11:41 IR $} ~ e BI
CONFIGURE + & STD I E žep
GSH Connection
CONT (F1)
To accept the change and to
GSH Type : Hanufacet HedelId zs , .
continue with the subsequent
Bluetooth : No screen.
NEAR (F2)
Station d oo
Number : 0041716563451
Protocol : Analog
Available when reference stations to
dial are already created in
CONFIGURE Stations to Dial. To
an ASS No Liz find the nearest reference station
CONT | NEAR |CODES| | | | with a digital cellular phone.
CODES (F3)
Available for digital cellular phones of
GSM technology. To enter the
Personal Identification Number of the
SIM card.
SRCH (F4)
Available for <Bluetooth: Yes>. To
search for all available Bluetooth
devices.
SHIFT INFO (F2)
Available for CDMA digital cellular
phones. To find out information
about the digital cellular phone.
SHIFT REG (F3)
Available for CDMA digital cellular
phones. To register the digital
cellular phone.
SHIFT CMND (F4)
To send AT commands to the digital
cellular phone.
Config...\Interfaces... - Controlling TPS1200+ 139
the Device
140
Description of fields
Field
<GSM Type:>
Option
Output
Description
Available for digital cellular phones of GSM tech-
nology. The type of digital cellular phone high-
lighted when CONFIGURE XX Connection was
accessed.
<CDMA Type:>
Output
Available for digital cellular phones of CDMA
technology. The type of digital cellular phone
highlighted wnen CONFIGURE XX Connection
was accessed.
<Bluetooth:>
Yes or No
SmartStation detects automatically if the
attached device is bluetooth capable. Some
devices ask for the identification number of the
Bluetooth. The identification number of Leica’s
Bluetooth is 0000.
<ID Address:>
<Station:>
<Number:>
User input
Choicelist
Output
Available for <Bluetooth: Yes>. The ID address
of the Bluetooth device to be used. Refer to the
device’s user manual for information about the
ID address.
The digital cellular phone reference station to be
dialed. Opening the choicelist accesses
CONFIGURE Stations to Dial where new refer-
ence stations can be created and existing refer-
ence stations can be selected or edited.
The number of the digital cellular phone at the
selected <Station:> as configured in
CONFIGURE Stations to Dial.
<Protocol:>
<Auto CONEC:>
Output
Yes or No
Available for digital cellular phones of GSM tech-
nology. The configured protocol of the digital
cellular phone at the selected <Station:> as
configured in CONFIGURE Stations to Dial.
Allows for automatic connection between the
rover and the reference when a point is occupied
during a survey.
<Net Data Rate:>
<Connection:>
Auto-
bauding,
2400 bps to
56000 bps
Transparent
Non-Trans-
parent
Available for digital cellular phones of GSM tech-
nology. The network baud rate. Select Auto-
bauding for an automatic search of the network
baud rate. For digital cellular phones of GSM
technology that do not support autobauding
choose the baud rate from the choicelist.
Available for digital cellular phones of GSM tech-
nology. Define if the digital cellular phone uses
Radio Link Protocol.
For digital cellular phones that do not use RLP.
For digital cellular phones that use RLP.
TPS1200+ Config...\Interfaces... - Controlling
the Device
Next step
IF the digital THEN
cellular phone is
not of type CDMA |CONT (F1) to accept the change and to continue with the
or does not need to | subsequent screen.
be registered
of type CDMA and
needs registering
SHIFT REG (F3) to access CONFIGURE CDMA Registra-
tion. Refer to paragraph "CONFIGURE CDMA Registration".
CONFIGURE Description of fields
CDMA Registration
Field Option Description
<Prog Code:> User input The service program coder provided by
the network provider.
<My Phone No:> | User input Type in the mobile directory number
provided by the network provider.
Next step
Step |Description
1. CONT (F1) returns to CONFIGURE Interfaces.
2. CONT (F1) returns to the screen from where CONFIGURE Interfaces
was accessed.
Config...\Interfaces... - Controlling TPS1200+ 141
the Device
22.2 Modems
Description For modems, information such as:
e the reference stations that can be contacted and
e the phone numbers of the reference stations can be controlled.
Configure modem The following table explains the most common settings. Refer to the stated chapter
connection for more information on screens.
step-by-ste
gé g Step Description
1. Refer to "20.1.2 Configuring an Interface" to access CONFIGURE Inter-
faces.
2. In CONFIGURE Interfaces highlight an interface which has a modem
attached.
CTRL (F4) to access CONFIGURE Modem Connection.
CONFIGURE Modem Connection
<Modem Type:> The type of modem highlighted when CONFIGURE
Modem Connection was accessed.
<Station:> The modem reference station to be dialled. Accesses
CONFIGURE Stations to Dial where new reference stations can be
created and existing reference stations can be selected or edited.
<Number:> The number of the modem at the selected <Station:> as
configured in CONFIGURE Stations to Dial.
Select the modem reference station to be dialled.
Ce | NEAR (F2) finds the nearest reference station with a modem. Available
when reference stations to dial are already created in CONFIGURE
Stations to Dial. Coordinates of these stations must be known.
5. CONT (F1) returns to CONFIGURE Interfaces.
142 TPS1200+ Config...\Interfaces... - Controlling
the Device
22.3 Radios for GPS Real-Time
Description
Access
CONFIGURE
Radio Channel
Config...\Interfaces...
the Device
For radios the channels on which the radio broadcasts can be changed. Changing
channels changes the frequency at which the radio operates.
Refer to "20.3.3 Controlling a Device" to access CONFIGURE Radio Channel.
41:43 et CN se RI
CONFIGURE + & STD cc CONT (F1)
Radio Channel To accept the changes and to
Radio Type Satelline 3A5 continue with the subsequent
Chanel RE screen.
Actual Freq : 0.0000MHz SCAN (F5)
Available unless <Set Channel:
Auto>. To find out information such
as the station ID, latency and the
DECK data format of incoming signals from
CONT | | | | SCAN | | reference stations.
Description of fields
Field Option
<Radio Type:> Output
Description
The type of radio highlighted when
CONFIGURE Radio Channel was
accessed.
<Set Channel:> | Output Available for <Radio Type:
AW100/2007400>.
Manually The channel must be typed in manually.
Auto A reference selects the clearest
frequency of the available channels.
A rover searches for the channel wjhere
data is transmitted.
<Channel:> User input Available unless <Set Channel: Auto>.
The radio channel. The minimum and
maximum allowed input values for a radio
depend on the number of channels
supported by the radio and the spacing
between the channels.
<Actual Freq:> Output Available for Satelline 3AS radios.
Displays the actual frequency of the radio.
- Controlling TPS1200+ 143
22.4 Radios for Remote Control
Description
Configure
TCPS27/RH1200
connection
step-by-step
144
For radios the channels on which the radio broadcasts can be changed. Changing
channels changes the frequency at which the radio operates. This may be necessary
to enable multiple pairs of radios to work simultaneously in the same area without
interferring with each other. The following radios for remote control support channel
changing:
e TCOPS27 e RadioHandle
Refer to the stated chapter for more information on screens.
Step
1.
2.
Description
Access CONFIGURE Interfaces.
Highlight the interface RCS Mode with either RadioHandle or TCPS27
attached as the device.
CTRL (F4) to access CONFIGURE TCPS27 / RH1200.
CONFIGURE TCPS27 / RH1200.
<Radio Type:> The type of protocol, which is fixed as RCS.
<Link Number:> The assigned channel number (from 0 to 15).
The link number for the RX1200 controller and the radio must be the
same. The communication settings for the RX1200 controller and the
radio must also be same.
<Set as:> The option Remote or Base are available.
Remote sets the radio into remote mode.
Base sets the radio into base mode.
The radio modules inside the RX1200 controller and the radio must be set
to opposite settings. It is recommended to set the RX1200 controller to
Remote and the radio to Base.
TPS1200+ Config...\Interfaces... - Controlling
the Device
22.5 RS232
Description
Configure RS232
connection
step-by-step
RS232 is a standard serial communication method that is able to transfer data
without the need for predefined time slots. RS232 can be used, with a Bluetooth
housing, to provide a wireless connection to another Bluetooth enabled device, for
example, a computer.
The following table explains the most common settings. Refer to the stated chapter
for more information on screens.
Step
Description
1.
Refer to "20.1.2 Configuring an Interface" to access CONFIGURE Inter-
faces.
In CONFIGURE Interfaces highlight an interface which has an RS232
device attached.
CTRL (F4) to access CONFIGURE RS232 Connection.
CONFIGURE RS232 Connection
<Device:> The type of device highlighted when CONFIGURE RS232
Connection was accessed.
<Bluetooth:> SmartStation detects automatically if the attached device
is bluetooth capable. Some devices ask for the identification number of
the Bluetooth. The identification number of Leica’s Bluetooth is 0000.
<ID Address:> Available for <Bluetooth: Yes>. The ID address of the
Bluetooth device to be used. Refer to the device’s user manual for infor-
mation about the ID address.
SRCH (F4) available for <Bluetooth: Yes>, to search for all available
Bluetooth devices. If more than one Bluetooth device is found a list of
available devices is provided.
SCAN (F5) provides information such as the station ID, latency and the
data format of incoming signals from reference stations. This information
can be used to select appropriate reference stations to dial.
CONT (F1) returns to CONFIGURE Interfaces.
Config...\Interfaces... - Controlling TPS1200+ 145
the Device
22.6 GPRS / Internet Devices
Description
Access
CONFIGURE
GPRS/Internet
Connection
146
GPRS / Internet devices can be used to access the Internet from TPS1200+ with
Communication side cover.
Refer to "20.3.3 Controlling a Device" to access CONFIGURE GPRS/Internet
Connection.
11:46 Lei I + ze B CONT (F1)
CONFIGURE | em LV | To accept the changes and to
B
— esch TETE x continue with the subsequent
screen.
Bluetooth : Yos CODES (F3)
ID Addross : SESS Available for digital cellular phones of
APN s GSM technology. To enter the
(cont) Be Personal Identification Number of the
SIM card. If the PIN is locked for any
uzat reason, input the Personal
CONT | | CODES| SRCH | | | UnblocKing code for access to the
PIN.
SRCH (F4)
Available for <Bluetooth: Yes>. To
search for all available Bluetooth
devices.
SHIFT CMND (F4)
To send AT commands to the GPRS
/ Internet device.
Description of fields
Field Option Description
<Device:> Output The type of GPRS / Internet device highlighted
when CONFIGURE GPRS/Internet Connec-
tion was accessed.
<Bluetooth:> | Output SmartStation detects automatically if the
attached device is bluetooth capable. Some
devices ask for the identification number of the
Bluetooth.
<ID Address:> | User input Available for Bluetooth: Yes>. The ID
address of the Bluetooth device to be used.
Refer to the device’s user manual for informa-
tion about the ID address.
<APN:> User input Available for some GPRS / Internet devices.
The Access Point Name of a server from the
network provider, which allows access to data
services. Contact your provider to get the
correct APN. Mandatory for using GPRS.
TPS1200+ Config...\Interfaces... - Controlling
the Device
22.7 Internet
Lë
Description
Requirements
Configure port NET
step-by-step
The Internet connection is available for SmartStation.
The Internet connection allows SmartStation to be connected to the Internet to
receive real-time data. A GPRS / Internet device must be attached.
e <Internet: Yes> in CONFIGURE Internet Interface.
e <Port: NETx> assigned to an interface in CONFIGURE Interfaces.
Description
Refer to "20.1.2 Configuring an Interface" to access CONFIGURE Inter-
faces.
CONFIGURE Interfaces
Highlight an interface which has an Internet device attached.
CTRL (F4) to access CONFIGURE Set NET Port.
CONFIGURE Set NET Port, General page
<Name:> The name of the port NET that was attached to the interface
that was highlighted when this page was accessed.
<User:> How SmartStation will operate in the Internet.
<User: Client> must be selected when using NTRIP as Internet applica-
tion. Inside the Internet NTRIPClients and NTRIPServers are considered
as clients.
<User: Server> must be selected when SmartStation is the server.
<IP Address:>
For <User: Client>: Type in the IP address of the server to be accessed
in the Internet.
For <User: Server>: Output of the IP address associated with the static
IP address as configured in CONFIGURE Internet Interface.
<TCP/IP Portz A number can be assigned to each of the ports. Type in
the NET port number.
<Auto CONEC:> Available for <User: Client>.
For <R-Time Mode: Rover> in CONFIGURE Real-Time Mode
Allows for automatic connection between the rover and the Internet when
a point is occupied during a survey. Ending the point occupation also
ends the Internet connection.
PAGE (F6) to access CONFIGURE Set NET Port, Ranges page
CONFIGURE Set NET Port, Ranges page
For <User: Server> in CONFIGURE Set NET Port, General page, the
fields are input fields. The fields <Range X From:> and <Range X To:>
can be used to prevent a user with an IP address outside the defined
ranges from accessing the instrument.
Enter the IP address ranges.
CLEAR (F5) returns the fields back to their default values.
Config...\Interfaces... - Controlling TPS1200+ 147
the Device
148
Step
Description
CONT (F1) returns to the screen from where CONFIGURE Set NET Port
was accessed.
TPS1200+
Config...\Interfaces... - Controlling
the Device
22.8 Creating a New Station to Dial/Editing a Station to Dial
Description
Access
step-by-step
Lë
CONFIGURE
XX Station to Dial
Config...\Interfaces...
the Device
CONFIGURE Stations to Dial allows new stations to be created, provides a list of
reference stations that can be dialed and allows existing stations to be edited.
For digital cellular phones of any technology and for modems, the phone numbers
of the device at the reference station must be known. For a reference station to be
dialed, a name, the phone number and, if available, the coordinates can be config-
ured.
The configuration is possible for rover and reference digital cellular phones and
modems.
Step |Description
1. Refer to "20.3.3 Controlling a Device" to access CONFIGURE XX
Connection/CONFIGURE Radio Channel.
2. Open the choicelist for <Station:> to access CONFIGURE Stations to
Dial.
E? CONFIGURE Station to Dial
If a station is to be edited, then highlight the station.
4. NEW (F2)/EDIT (F3) to access CONFIGURE New Station to
Dial/CONFIGURE Edit Station to Dial.
Editing a station to dial is similar to creating a new station to dial. For simplicity the
screens are called CONFIGURE XX Station to Dial and differences are clearly
outlined.
ee . - RI
CONFIGURE Le" STD Be &
New Station to ECH
Name : station STORE (F1) ,
To store the changes and to continue
Number : ERKAKEKEAER with the subsequent screen.
Protocol : Ana log dl COORD (F2)
lse Coords: Yes d| To view other coordinate types.
WGS84 XS: 4264320.6834 u SHIFT ELL H (F2) or SHIFT ORTH (F2)
WGS84 YC: f25157.355 m Available for local coordinates. To
WGS84 zs: 4672132.050 m ae
uza f change between the ellipsoidal and
STORE| COORD| | | | | the orthometric height.
Description of fields
Field Option Description
<Name:> User input A unique name for the new reference
station to be dialed. The name may be up
to 16 characters long and may include
spaces. Input optional.
- Controlling TPS1200+ 149
150
Field
Option
Description
<Number:> User input
<Protocol:>
Analog
ISDN v. 110
<Enter Coords:> | Yes or No
The number of the reference station to
dial. If the survey is to be undertaken
across country borders it is necessary to
input the phone number using standard
international dialing codes. For example,
+41123456789. Otherwise it can be input
as a standard digital cellular phone
number.
Available for digital cellular phones of
GSM technology. The configured protocol
of the digital cellular phone of GSM tech-
nology.
For conventional phone networks.
For GSM networks.
Allows the coordinates of the reference
station to be entered.
Coordinates User input The coordinate of the reference station.
Next step
Step |Description
1.
STORE (F1) stores the changes and returns to CONFIGURE Stations to
Dial.
CONT (F1) returns to the screen from where CONFIGURE Stations to
Dial was accessed.
TPS1200+
Config...\Interfaces... - Controlling
the Device
22.9 Creating a New Server to Connect/Editing a Server to Connect
Description
Access step-by-
step
Lë
CONFIGURE
XX Server to
Connect
CONFIGURE Server to Connect allows new servers to be created, provides a list
of servers to be connect in the internet and allows existing servers to be edited. For
servers to be accessed in the Internet the IP address and the TCP/IP port must be
known. For a server to be accessed in the Internet a name can be configured.
Step |Description
1. Refer to "20.3.3 Controlling a Device" to access CONFIGURE XX
Connection/CONFIGURE Radio Channel.
2. Open the choicelist for <Server:> to access CONFIGURE Server to
Connect.
3. CONFIGURE Server to Connect
If a server is to be edited, then highlight the server.
4. NEW (F2)/EDIT (F3) to access CONFIGURE New Server to
Connect/CONFIGURE Edit Server to Connect.
Editing a server to connect is similar to creating a new server to connect. For
simplicity the screens are called CONFIGURE XX Server to Connect and differ-
ences are clearly outlined.
22:39 IR $ ~ e RI
CONFIGURE + @ STD I Bo @
Name : server
IP Address 8 182.168.41.41
TCP/IP Port M
STORE (F1)
uzat To store the changes and to continue
STORE| | | | | | with the subsequent screen.
Description of fields
Field Option Description
<Name:> User input A unique name for the new server to be
accessed in the Internet. The name may be up
to 16 characters long and may include spaces.
<IP Address:> | User input The IP address of the server to be accessed in
the Internet.
<TCP/IP Port:> | User input The port of the Internet server through which the
data is provided. Each server has several ports
for various services.
Config...\Interfaces... - Controlling TPS1200+ 151
the Device
Next step
Step |Description
1; STORE (F1) stores the changes and returns to CONFIGURE Server to
Connect.
2. CONT (F1) returns to the screen from where CONFIGURE Server to
Connect was accessed.
152 TPS1200+ Config...\Interfaces... - Controlling
the Device
23 Config...\SmartStation...
23.1 Real-Time Mode
Description The settings on this screen allow GPS real-time related parameters to be configured.
This includes defining whether SmartStation should operate as a rover (static, as on
a tripod) and the type of GPS real-time messages to be used.
Access Select Main Menu: Config...\SmartStation...\Real-Time Mode.
CONFIGURE 09:17 +R I $ a e Bi
Real-Time Mode CONFIGURE STD a <7 8! CONT (F1)
Sec — FT Y To accept changes and return to the
R-Time Data: Leica dy screen from where this screen was
Port Port 2(Handle) <4 accessed.
Device ; Siemens HC45 ROVER (F2)
Ref Sensor : GH1230 dh To configure additional settings rele-
Ref Antenna E vant to rover operations.
DEVCE (F5)
DECK To create, select, edit or delete a
CONT | ROVER| | | DEVCE| | device.
Description of fields
Field Option Description
<R-Time Mode:> None SmartStation is not to be used as a GPS real-
time rover.
Rover Activates a rover GPS real-time interface.
<R-Time Data:> | Choicelist The GPS real-time data format which is to be
received from the reference station.
<Port:> Port to which the device is attached.
Port 1 For communication and/or power. This port is
located at the base of the instrument.
For TPS1200+: 5 pin LEMO-0
Port 2 (Handle) |Hotshoe connection for RadioHandle with
RCS and SmartAntenna Adapter with Smart-
Station. This port is located on top of Commu-
nication side cover.
Port 3 (BT) Bluetooth module for communication with
only Bluetooth capable devices. This port is
housed within Communication side cover.
NETx Available for an activated Internet interface. If
these ports are not assigned to a specific
interface, then these ports are additional
remote ports.
Config...\SmartStation... TPS1200+ 153
CONFIGURE
Additional Rover
Options,
General page
154
Field Option Description
<Ref Sensor:> | Choicelist The receiver type used at the reference. If the
GPS real-time data format does not contain
the information of the receiver type certain
corrections based on the information of the
receiver type are applied in order to provide
correct results. The GPS real-time data
formats Leica, CMR and CMR+ contain this
information. This is mainly important when a
System300 receiver is used as reference.
<Ref Antenna:> | Choicelist The antenna used at the reference. If the
GPS real-time data format does not contain
the information of the antenna certain correc-
tions based on the information of the antenna
are applied in order to provide correct results.
The GPS real-time data formats Leica,
RTCM v2.3, CMR and CMR¢+ contain this
information.
If the reference data is corrected by absolute
antenna calibration values and a Leica
standard antenna is being used on the rover,
select ADVNULLANTENNA as reference
antenna.
The available fields depend on the selected <R-Time Data:> in CONFIGURE Real-
Time Mode.
CONT (F1
09:18 Ter I $ EN (F1)
S10
CONFIGURE To accept changes and return to the
screen from where this screen was
Reneral NTRIP
Accept Ref accessed.
GGA (F4)
E E ger To activate the sending of a GGA |
Send User ID - e? message for reference network appli-
cations.
GETID (F5)
uzat Available for <Accept Ref: User
CONT | | | GGA | | PAGE | Defined>. To display and select the
station ID of the available reference
stations, the latency of the message
and the data format. When using
radios, the radio channel can be
switched and the stations received on
the new frequency are displayed.
1st (F6)
Available for <Accept Ref: First
Received>. To force the system to
try to establish a new connection with
a different reference station.
TPS1200+ Config...\SmartStation...
Description of fields
Field
<Accept Ref:>
Option
User Defined
First Received
Any Received
<Ref Stn ID:> User input
From 0 to 31
From 0 to 1023
From 0 to 4095
Description
The reference station of which GPS real-
time data is to be accepted.
Incoming GPS real-time data is accepted
from the reference station defined in <Ref
Stn ID:>.
Incoming GPS real-time data from the
first recognised reference station is
accepted.
Incoming GPS real-time data from any
reference station is accepted.
Available for <Accept Ref: User
Defined>. The special ID of the reference
station from which GPS real-time data is
to be received. The allowed minimum and
maximum values vary.
For <R-Time Data: Leica> and <R-Time
Data: CMR/CMR+>.
For <RTCM Version: 1.x> and <RTCM
Version: 2.x>.
For <R-Time Data: RTCM v3.1>.
<Ref Network:> | None, VRS or Defines the type of reference network to
FKP be used.
<Send User ID:> | Yes or No Activates the sending of a Leica proprie-
tary NMEA message defining the user.
<User ID 1:> and | User input Available for <Send User ID: Yes>.
<User ID 2:>
The specific user ID’s to be sent as part of
the Leica proprietary NMEA message. By
default the serial number of the instru-
ment is displayed.
<RTCM Version:> | 1.x, 2.1, 2.2 or 2.3
Available for <R-Time Data: RTCM XX
v2> in CONFIGURE Real-Time Mode.
The same version must be used at the
reference and the rover.
<Bits / Byte:> 6ors
Defines the number of bits/byte in the
RTCM message being received.
Config...\SmartStation...
Next step
PAGE (F6) changes to the NTRIP page.
TPS1200+
155
CONFIGURE
Additional Rover
Options,
NTRIP page
156
12:35 dl > e RI
CONFIGURE tes STD D c A
CONT (F1)
To accept changes and return to the
screen from where this screen was
Gaeren NTRTP
Use NTRIP:
e SE Ee accessed.
(cont) Sa a
Password : = smm SRCE (F5)
To download the NTRIP source table
Hountpnt : waa
if <Mountpnt:> is unknown. To do
DECK this, the GPRS Internet interface
CONT | | | | SRCE | PAGE | must already be configured.
Description of fields
Field Option Description
<Use NTRIP:> Yes or No Activates NTRIP.
<User ID:> User input A user ID is required to receive data from
the NTRIPCaster. Contact the NTRIP
administrator for information.
<(cont):> User input Allows the <User ID:> string to continue
onto a new line.
<Password:> User input A password is required to receive data
from the NTRIPCaster. Contact the
NTRIP administrator for information.
<Mountpnt:> User input The NTRIPSource from where GPS real-
time data is required.
Next step
Description
CONT (F1) returns to CONFIGURE Real-Time Mode.
CONT (F1) returns to TPS1200+ Main Menu.
TPS1200+ Config...\SmartStation...
23.2 Point Occupation Settings
Description The settings on this screen define the way in which points are occupied and
recorded.
Access Select Main Menu: Config...\SmartStation...\Point Occupation Settings.
CONFIGURE Ties (esch $ % e Bi
Point Occupation CONFIGURE. STD aag
Settings ait: 7
, CONT (EI
Auto OCCUPY : Tes 4H
Auto STOP ) To accept changes and return to the
STOP Criteria: screen from where this screen was
Beep On STOP : accessed.
Auto STORE
Beep On STORE: PARAM (F3) a
To configure the time interval after
End Survey : Manual del , , ,
DECK which a point occupation can be
CONT | | PARAH| | | | stopped automatically.
Description of fields
Field Option Description
<Pt Occupation:> | Normal The way in which coordinates for a point
are recorded.
This field is fixed to <Pt Occupation:
Normal>.
<Auto OCCUPY:> | No Starts point occupation when pressing
OCUPY (F1).
Yes Starts point occupation automatically
when entering SETUP New Station
Point.
Timed Starts point occupation automatically at a
certain time. The start time is specified in
SETUP New Station Point.
<Auto STOP:> Yes or No Stops the measurements automatically
when the parameter defined for <STOP
Criteria:> reaches 100 %.
<STOP Criteria:> Available for <Auto STOP: Yes>. Defines
the method used for <Auto STOP:>.
The setting determines the computation of
the duration of the point occupation.
Parameters for the selected method are
defined with PARAM (F3).
Accuracy or Available for <R-Time Mode: Rover>.
Positions
Config...\SmartStation... TPS1200+ 157
158
Field
Option
Time,
Observations or
No. of Satellites
Description
Available for <R-Time Mode: None>.
<% Indicator:>
None or
Positions
None, Time,
Observations or
No. of Satellites
Available for <Auto STOP: No>.
This is an indicator when to stop the point
occupation. Parameters for the selected
method are defined with PARAM (F3).
Available for <R-Time Mode: Rover?>.
Available for <R-Time Mode: None>.
<Beep On STOP:>
<Auto STORE:>
<Beep On
STORE:>
<End Survey:>
Yes or No
Yes or No
Yes or No
Manual
Automatically
Activates that a beep is made when the
point occupation is ended by <Auto
STOP:>.
Stores points automatically after stopping
the point occupation.
Activates that a beep is made when the
point is stored by <Auto STORE:>.
Defines the instrument behaviour once a
point is stored.
Exits GPS SURVEY when pressing ESC.
Exits GPS SURVEY automatically when
pressing STORE (F1) and returns to main
menu.
Next step
IF parameters for | AND THEN
<Auto STOP:>
are not to be - CONT (F1) closes the screen and returns
configured to the screen from where CONFIGURE
Point Occupation Settings was
accessed.
are to be config- <R-Time Mode: PARAM (F3) changes to CONFIGURE
ured None> Post-Process Stop Criteria.
are to be config- <R-Time Mode: PARAM (F3) changes to CONFIGURE
ured Rover> Real-Time Stop Criteria. Refer to para-
graph "CONFIGURE Real-Time Stop
Criteria”.
TPS1200+ Config...\SmartStation...
CONFIGURE
Real-Time Stop
Criteria
09:37 IR $ ~ e RI
CONFIGURE +e STD I Boo A
Real-Time Stop Criteria
Auto STOP/SIndicator based on
Pos Quality = : 0.050m
Ht Quality < 0.070 nm
For a min number of positions CONT (F1)
eee ge i a . To accept changes and to return to
"IER eae ‘(Gat CONFIGURE Point Occupation
CONT | | | | | | Settings
Description of fields
The parameters shown on this screen depend on the setting for <STOP Criteria:>
in CONFIGURE Point Occupation Settings.
Field Option Description
<Pos Quality <:> | User input Sets the maximum position and height
and qualities for each point occupation. Calcu-
<Ht Quality <:> lating the qualities starts when OCUPY
(F1) is pressed. SmartStation stops
measuring when the position and height
qualities are both less than the configured
values.
<Positions:> User input Point is occupied for a minimum number
of positions even when the <Pos Quality
<:> and <Ht Quality <:> is already less
than the specified maximum.
<Positions User input Sets the number the positions which must
Update> be observed before SmartStation stops
measuring. Counting the number of posi-
tions starts when OCUPY (F1) is pressed.
Next step
Step Description
1. CONT (F1) returns to CONFIGURE Point Occupation Settings.
2: CONT (F1) returns to TPS1200+ Main Menu.
Config...\SmartStation... TPS1200+ 159
23.3
Description
Access
CONFIGURE
Satellite Settings
160
Satellite Settings
The settings on this screen define which satellite system (available for SmartStation
wih ATX1230 GG), satellites and satellite signals will be used by the receiver.
Select Main Menu: Config...\SmartStation...\Satellite Settings.
FAN KC HEEN (Ch SÉ dr
CONFIGURE + 8 LS 2 äh
Satellite Settings
Sat System : STI ‘|
L2C Tracking : Automatic dl
Cut Off Angle:
Loss of Lock :
Suppres HPath:
[at
con ae
10 `
Beep & Message 4H
Automatic 4+]
Description of fields
Field
<Sat System:>
<L2C Tracking:>
<Cut Off Angle:>
<Loss of Lock:>
<Suppress
MPath>
Option
GPS Only
GPS & Glonass
Automatic or
Always Track
User input
Beep & Message
or
No
Beep/Message
Automatic or
Always On
TPS1200+
CONT (F1)
To accept changes and return to
TPS1200+ Main Menu.
Description
Available for SmartStation/ATX1230 GG.
Defines the satellite signals accepted by
the receiver when tracking satellites.
Only GPS satellites are tracked.
GPS and GLONASS satellites are
tracked.
Available for SmartStation/ATX1230 GG.
Defines if the L2C signal will be tracked.
The recommended setting is Automatic.
Sets the elevation in degrees below which
satellite signals are not recorded and are
not shown to be tracked. Recommended
settings:
For GPS real-time: 10°.
For other applications: 15°.
Activates an acoustic warning signal and
message given by SmartStation when
satellites are lost and therefore no posi-
tion can be computed.
Available for SmartStation/ATX1230 GG.
Defines if phase multipath mitigation
techniques will be used. The recom-
mended setting is Automatic.
Config...\SmartStation...
Next step
CONT (F1) returns to TPS1200+ Main Menu.
Config...\SmartStation... TPS1200+ 161
23.4 Local Time Zone
Description
Access
CONFIGURE
Local Time Zone
162
The settings on this screen help SmartStation to quickly locate and track satellites.
Select Main Menu: Config...\SmartStation...\Local Time Zone.
09:39 TOR] E . e BI
CONFIGURE STD Bo 8
Local Time Zone x
Time Zone : +1: 000g
Local Time : 10:39:51
Local Date : 21.11.05
CONT (F1)
To accept changes and return to
Uzat
CONT | | | | | | TPS1200+ Main Menu.
Description of fields
Field Option Description
<Time Zone:> From The time zone for the current location and
-13:00 to +13:00 "local date.
<Local Time:>
<Local Date:>
User input Setting the local time and date supports a
very fast satellite acquisition.
Next step
CONT (F1) returns to TPS1200+ Main Menu.
TPS1200+ Config...\SmartStation...
23.5 Quality Control Settings
Description
Access
CONFIGURE
Quality Control
Settings
The settings on this screen define t