OKI 


MSM9563 
IC for FM Multiplex 
Data Demodulation 


User's Manual 
[Hardware] 


SECOND EDITION 
ISSUE DATE: Dec. 1999 


FEUL9563-02 


IMPORTANT NOTICE 


DARC (DAta Radio Channel), an FM multiplex broadcast technology, has been developed by 
NHK (Japan Broadcasting Corporation). DARC is a registered trademark of NHK Engineering 
Service (NHK-ES). 

Any manufacturer who intends to manufacture/sell products that utilize DARC technology needs 
to be licensed by NHK-ES. 


For detailed information on licenses, please contact: 
NHK Engineering Service 
Phone: (481) 3-3481-2650 





DARC (DAta Radio Channel), an FM multiplex broadcast technology, has been 
developed by NHK (Japan Broadcasting Corporation). DARC is a registered 
trademark of NHK Engineering Service (NHK-ES). 

Any manufacturer licensed by NHK-ES can manufacture and sell products that 
utilize the DARC technology. The products utilizing the DARC technology can 
be marked with the logotype shown to the left. 

In the DARC system, 16kbps of digital data L-MSK modulated at 76KHz are 
multiplied on an ordinary FM broadcast base band signal. 

An FM multiplex demodulation LSI performs decoding of the digital data 
DATA RADIO CHANNEL signal. 


RU 
Аф 


For detailed information оп license, please contact: 
NHK Engineering Service Phone: 81-3-3481-2650 











E2Y0002-29-62 





NOTICE 


1: 


9. 


The information contained herein can change without notice owing to product and/or 
technical improvements. Before using the product, please make sure that the information 
being referred to is up-to-date. 


The outline of action and examples for application circuits described herein have been 
chosen as an explanation for the standard action and performance of the product. When 
planning to use the product, please ensure that the external conditions are reflected in the 
actual circuit, assembly, and program designs. 


When designing your product, please use our product below the specified maximum 
ratings and within the specified operating ranges including, but not limited to, operating 
voltage, power dissipation, and operating temperature. 


Oki assumes no responsibility or liability whatsoever for any failure or unusual or 
unexpected operation resulting from misuse, neglect, improper installation, repair, alteration 
or accident, improper handling, or unusual physical or electrical stress including, but not 
limited to, exposure to parameters beyond the specified maximum ratings or operation 
outside the specified operating range. 


Neither indemnity against nor license ofa third party's industrial and intellectual property 
right, etc. is granted by us in connection with the use of the product and/or the information 
and drawings contained herein. No responsibility is assumed by us for any infringement 
of a third party's right which may result from the use thereof. 


The products listed in this document are intended for use in general electronics equipment 
for commercial applications (e.g., office automation, communication equipment, 
measurement equipment, consumer electronics, etc.). These products are not authorized 
for use in any system or application that requires special or enhanced quality and reliability 
characteristics nor in any system or application where the failure of such system or 
application may result in the loss or damage of property, or death or injury to humans. 
Such applications include, but are not limited to, traffic and automotive equipment, safety 
devices, aerospace equipment, nuclear power control, medical equipment, and life-support 
systems. 


Certain products in this document may need government approval before they can be 
exported to particular countries. The purchaser assumes the responsibility of determining 
the legality of export of these products and will take appropriate and necessary steps at their 
own expense for these. 


No partofthe contents contained herein may be reprinted or reproduced without our prior 
permission. 


MS-DOS is a registered trademark of Microsoft Corporation. 


Copyright 1999 Oki Electric Industry Co., Ltd. 





Printed in Japan 


TABLE OF CONTENTS 


1. - GENERAL DESCRIBTION слава аи LLO FY LED noda dan ызаны n nr ardid 1-1 
2. BLOCK DIAGRAM eit teet tentia eei trate rear ана 2-1 
3. PIN.INFORMATION m 3-1 
3.1 PIN CONFIGURATION (TOP VIEW) геги кеша ийишин шина кыйна ннан 3-1 
3.2: -PIN DESCRIPTIONS ........ riti cte rene aaa aani вата enia 3-2 
4. ELECTRICAL CHARACTERISTICS .............. «нн ння 4-1 
4.1 ABSOLUTE MAXIMUM RATINGS ............... нання 4-1 
4.2 RECOMMENDED OPERATING CONDITIONS ........................................... 4-1 
43 DG ¡CHARACTERISTICS дананын ri nte авіа 4-2 
4:4 AG CHARACTERISTICS iii iiiter аван а 4-3 
4.5 FILTER CHARACTERISTICS ................. анна 4-4 
4.6 TIMINGIDIAGRAM «2.2 tot reed ea 4-5 
5. CONTROL. REGISTERS ii aeo otn attt tre rece ак наван 5-1 
5.1. OPERATING MODE REGISTERSG........... retinent trentaine 5-1 
5:2. INTERRUPT REGISTERS озона ettet 5-5 
5.3. RECEIVE DATA REGISTERS ritenere teer un а 5-7 
5.4 TIMING INTERRUPT REGISTERS ................. ння 5-21 
5.5 CLOCK REGENERATION REGISTERS ................ esee 5-28 
5.6 BLOCK SYNCHRONIZATION REGISTERS ..................... sese 5-30 
5.7 FRAME SYNCHRONIZATION REGISTERS ................................................ 5-34 
5.8 ERROR CORRECTION REGISTERS ................. нання 5-36 
5.9. LAYER 4 CRO REGISTERS ына nitet inet rire 5-38 
5:10 ANALOG TEST REGISTER знан нан нан rancia 5-40 
5:11: POWER DOWN REGISTER: а аа аа 5-41 
512 TEST CONTROL REGISTERS... ict ortae ecrit абы iti 5-42 
5.13 EXTENSION PORT REGISTER... лье ошььн аниме 5-44 
6. EXTERNAL CONNECTION ¡EXAMPLE «гг 6-1 
7. APPLICATION GIRGUIT ла seco teen eese аа дно cash аа 7-1 
APPENDIX: LIST OF REGISTER. rnnt tatit er eese Appendix-1 


Chapter 1 


GENERAL DESCRIPTION 





MSM9563 User's Manual 
Chapter 1 GENERAL DESCRIPTION 


GENERAL DESCRIPTION 


The MSM9563 is an IC which demodulates FM character multiplex signals in the DARC (DAta 
Radio Channel) format to acquire digital data. This IC operates at 3 V. In the DARC format, 
baseband signals at ordinary FM broadcasting frequencies are multiplexed with 16 kbps digital 
data which is L-MSK-modulated at 76 kHz. 


The MSM9563 has a bandpass filter consisting of an SCF, frame synchronization circuit, and error 
correction circuit on a single chip. 


They allow a system for acquisition of digital data to be easily constructed by externally mounting 
an FM receiver tuner, microcontroller for control, and memory for temporary storage of data. 


The М5М9563, a FM multiplex demodulator, has a simple configuration, and is equipped with only 
necessary functions. By making changes to software for the external microcontroller, the 
MSM9563 meets the various requirements of FM multiplex broadcasting services to be offered 
in future. 


*1 DARC is a registered trademark of NHK Engineering Services. 
Any manufacturer licensed by NHK Engineering Service can manufacture and sell products that 
utilize the DARC technology. 


For detailed information on license, please contact: 
NHK Engineering Service Phone: 81-3481-2650 


FEATURES 


* Built-in two receive channels including main channel and sub-channel 

(one of two FM stations can be selected) 

Pin compatible with MSM9553 / MSM9555 

Internal frame memory enables automatic error correction. 

Built-in bandpass filter (SCF) 

Built-in block synchronization circuit and frame synchronization circuit 

The number of synchronization protecting steps can be set 

Regeneration of data clocks by digital PLL 

1T delay detector 

Built-in error correcting circuit (Vertical/Horizontal) 

Built-in layer-4 and layer-2 CRC processing circuit 

International frame formats A (supporting a real time block), B, and C available 
Microcontroller parallel interface 

Clock output for external devices (64 kHz to 8.192 MHz selectable) 

Power source: 2.7 to 3.6 V 

Package: 44-pin plastic QFP (QFP44-P-910-0.80-2K) (Product name: MSM9563GA) 


1-1 


MSM9563 User's Manual 
Chapter 1 GENERAL DESCRIPTION 


1-2 


Chapter 2 


BLOCK DIAGRAM 





FM multiplex 


й 1 O 
signal input 








Block Frame Timing Clock 
synchronization synchronization control generator 


Filter Section 
PN Error 


Descrambler Receive RAM МЕ Layer 4 CRC 


Layer 2 CRC 








IC internal 
clock 


Data bus 
Delay Detection Section 


Address bus 
Frequency 


O s 
CPU interface 
1T delay 
= ERES 


XTAL2 — XTAL1 Data Add RD WR CS CLR INT 


Digital Signal Processing Section 














Figure 2.1 Block Diagram 


< 


INVH9VIG 320718 


INVHOVIG 42018 г 1919е45 
jenueyy S,Jesf) £9S6WSW 


MSM9563 User's Manual 
Chapter 2 BLOCK DIAGRAM 


2-2 


Chapter 3 


PIN INFORMATION 





MSM9563 User's Manual 
Chapter 3 PIN INFORMATION 


3. PIN INFORMATION 


3.1 PIN CONFIGURATION (TOP VIEW) 


cc 
m" 


*NC 
*NC 
*NC 
*NC 






































































































































о 
= 5 2 © © = 
ч в N о о со N co LO < 
хр ч + Ut Ut со со со со со со 
MON (9 [33] A0 
ADETIN 32| XOUT 
AVpp 31| CS 
AGND 30| XTAL2 
SG [29] XTAL1 
AIN 281 DVpp 
XOUTC [27] DGND 
MOUTO 26| DB7 
MOUT1 [25] 086 
MOUT2 24] 085 
MOUT3 Ф [23] 084 
Ее 8 = 
ч LO co E cc o aO о T— N со 
гевЕ ега 88 
o o o 
= = = 


44-Pin Plastic QFP 


Figure 3.1 Pin Layout 


* Leave the NC pins (17, 39, 41, 42, 43, and 44) open. 


3-1 


MSM9563 User's Manual 
Chapter 3 PIN INFORMATION 


3.2 PIN DESCRIPTIONS 


Table 3.1 Pin Description 

































































Function Symbol Pin Type Description 
Microcontroller WR 16 | Write signal to internal register. 
interface RD 18 | Read signal to internal register. 

INT 15 0 Interrupt signal to microcontroller. When set to 
"L", an interrupt is generated. 

CS 31 Chip select signal. When set to "L", the read, write, 
and data bus signals become effective. 

CLR 40 When set їо "L", the internal register is initialized, 
and the IC enters power down mode. 
A0 to A5 33 to 38 | Address signal to internal register. 
DBO to DB7 | 19to 26 1/0 Data bus signal to internal register. 
Tuner interface AIN 6 | FM multiple signal input. 

SG 5 0 Analog reference voltage pin. Connect a 
capacitor between this pin and the analog ground 
pin to prevent noise. 

Analog section MON 1 0 Analog section waveform monitoring pin. The 
test mode setting for the blocks in the analog section 
is specified by the analog section control register. 
ADETIN 2 | Analog signal input pin for testing. 
Digital section MOUTO to 8to 14 0 Digital section test signal output and monitor 
test MOUT6 output pins. 
Clock XTAL1 29 | 8.192 MHz crystal connection. 
XTAL2 30 0 8.192 MHz crystal connection. 
XOUT 32 0 Pin to supply variable clock (64 kHz to 8.192 MHz) 
to external devices. 
XOUTC 7 XOUT control. "L" sets XOUT output, 
"H" sets XOUT output inhibit. This pin is pulled up 
internally. 
Power supply AVpp 3 = Analog power supply. 
AGND 4 — Analog ground. 
DVpp 28 = Digital power supply. 
DGND 27 — Digital ground. 

















Chapter 4 


ELECTRICAL 
CHARACTERISTICS 





MSM9563 User's Manual 
Chapter 4 ELECTRICAL CHARACTERISTICS 







































































4. ELECTRICAL CHARACTERISTICS 
4.1 ABSOLUTE MAXIMUM RATINGS 
No. Parameter Symbol Condition Rating Unit 
AVpp 
1 | Power supply voltage a | —0.3 to 47.0 
DVpp AVpp - DVpp V 
Й Input voltage Vi Ta = 25°C —0.3 to AVpp + 0.3 
Output voltage Vo -0.3 to DVpp + 0.3 
Maximum power Ta = 25°C, per package 400 
3 BA Pp mW 
dissipation Ta = 25°C, per output 50 
4 |Storage temperature Тете = —55 to +150 °C 
4.2 RECOMMENDED OPERATING CONDITIONS 
No. Parameter Symbol Condition Range Unit | Applied Pin 
AVpp AVpp 
1 | Power supply voltage ——— —— AVpp = DVpp 2.7 to 3.6 VI 
DVpp DVpp 
2 Crystal oscillation р 8.192 MHz +100 XTAL1, 
frequency MAE v | Se S XTAL2 
Variable amplifier gain: х 1 0.6 to 0.9 
FM multiplex signal Variable amplifier gain: x 1.5 0.4 to 0.6 
3 |. VAN" | EE Vp-p AIN 
input voltage Variable amplifier gain: x 2 0.3 to 0.4 
Variable amplifier gain: x 3 0.2 to 0.3 
4 | Operating temperature Ta = -40 to +85 °C = 























* Peak values (а total voltage of the following signals (а) їо (с)) of composite signals including 


multiplex signals. 
(a) Voice signals (100% modulated: voice max.) 


(b) Pilot signal 


(c) FM multiplex signals (1096: LMSK max.) 
The maximum amplitude of an input signal is in the range of 0.9 Vp.p in which the internal IC 
circuit is not saturated. 
Therefore, multiplex singnals of up to 0.9 Vp.p can be input if only multiplex signals (excluding 


composite signals) are input from a signal generator. 


MSM9563 User's Manual 
Chapter 4 ELECTRICAL CHARACTERISTICS 





















































4.3 DC CHARACTERISTICS 
(DVpp = AVpp = 2.7 to 3.6 V, DGND = AGND = 0 V, Ta = -40 to +85°C) 
No Parameter Symbol Condition Min. | Typ. | Max. | Unit |Applied Pin 
0.8 x WR, RD, 
V MN эк — 
IH DVpp XOUTC, 
1 |Input voltage — V DBO to DB7, 
V e НО CS, A0 to A5, 
IL 2 
DVpp CLR 
DVpp MOUTO to 
V Іон = -1 mA — — — 
RF m hi 05 y | MOUT6, INT, 
utput v 
И | -— - DBO to DB7, 
a ай | XOUT 
| Vin = DV. 2 MD pS; 
3 | Input current 1 шш А A 
| | ViL = DGND 2 і on 
IL1 и = GR 
Іна Vin = AVpp = = 2 
4 | Input current 2 НА | ADETIN 
lio Vit = AGND —2 = = 
5 | Input current 3 нз Vin = DVpp = — 2 pA 
DVpp = 3 V, XOUTC 
6 | Pull-up current | 3 15 50 A 
p pull Му = ОСМО H 
| Мон = AVpp _ _ Й 
Output off-leakage on During nonmonitoring (Hiz) 
7 uA | MON 
current | Vor = AGND Й 
1 During nonmonitoring (Hiz) 
During operation, no load 
— 14 28 mA 
f = 8.192 MHz 
8 | Supply current Ipp AVpp, DVpp 
During power down, 
— — 50 ЦА 
no load 





























MSM9563 User's Manual 
Chapter 4 ELECTRICAL CHARACTERISTICS 



























































4.4 AC CHARACTERISTICS 
(DVpp = AVpp = 2.7 to 3.6 V, DGND = AGND = 0 V, Ta = -40 to +85°C) 
No. Parameter Symbol* Condition Min. | Тур. | Мах. | Unit | Applied Pin 
{буі See figure 4.1 3 e» [З WR, CS, 

1 | Write setup time ns | AO to Ad, 
tswr2 See figure 4.1 90 — — DBO to DB7 
tHwR1 See figure 4.1 -18 — — WR, CS, 

2 | Write hold time ns | AO to АБ, 
tuwR2 See figure 4.1 10 — — DBO to DB7 

3 |Write pulse width twwr See figure 4.1 90 — — ns |WR 

4 |Read setup ti t See fi 4.2 3 Au 

im | — — n 
ead setup time SRD ee figure S AO to A5 

5 |Read hold ti t See fi 4.2 18 ДЕ 

ead hold time у = = = ns 
HRD ee figure AO to A5 
6 |Read pulse width twRD See figure 4.2 90 — = ns |RD 
a Read data output р еей Bü Е RD, 
delay (1) URBI ee DBO to DB7 
Read data output RD, 
8 t i . — — 20 ns 
delay (2) DRD2 See figure 4.2 DBO to DB7 
Layer 4 data | A CRC mod 
9 | Interval between write | tiwawre Бай | coer 620 — — ns |WR 
й See figure 4.3 
and write 
Layer 4 data | A REOR 
10 | Interval between write | tiwerpi ayer | Шо 1.2 — — us |WR,RD 
See figure 4.3 
and read 
Interval between write uu 
11 | tIWRWR See figure 4.4 300 | — — ns |WR 
and write 
Continuously writing 
Interval between write 0x3B to 0x3D to the == 
12 . tiwRWR1 550 — — ns WR 
and write same address 
See figure 4.5 
Interval between write | —— 
13 tIWRRD See figure 4.4 300 | — = ns | МВ, ВЮ 
and read 
Interval between read | — 
14 tIRDRD See figure 4.6 300 | — = ns ¡RD 
and read 
| INT, 
15 | Interrupt CLR delay tpINTCLR See figure 4.7 200 — — ns WR 
16 | CLR pulse width twoLr See figure 4.8 200 | — — ns |CLR 





























* See "TIMING DIAGRAM". 


4-8 


MSM9563 User's Manual 
Chapter 4 ELECTRICAL CHARACTERISTICS 














4.5 FILTER CHARACTERISTICS 
(DVpp = AVpp = 2.7 to 3.6 V, DGND = AGND = 0 V, Ta = -40 to +85°C) 
No. Parameter Symbol Condition Min. | Typ. | Max. | Unit |Applied Pin 
BPF pass band nn 
1 [ і GAIN1 | Variable gain amplifier | — = 3.0 dB | MON 
attenuation а 
gain: 0 dB 
BPF block band ни 
2 . GAIN2 | Variable gain amplifier 50 = — dB | MON 
attenuation (1) : 
gain: 0 dB 
BPF block band un 
3 GAIN3 | Variable gain amplifier 50 — — dB | MON 





attenuation (2) 








gain: 0 dB 




















4-4 


MSM9563 User's Manual 
Chapter 4 ELECTRICAL CHARACTERISTICS 


4.6 TIMING DIAGRAM 


Address input X | X 








CS input 





WR input 











Figure 4.1 Write Timing 





Address input x | | X 








— sm м — mp j— 
CS input i | | и 
—= Бя -— — tup | з 


О іприї 








-— twa = 
o о — — 


вот | | ÎDRD2 





Data bus output 





Figure 4.2 Read Timing 


MSM9563 User's Manual 
Chapter 4 ELECTRICAL CHARACTERISTICS 








Address input X Х 0x29 X 0x2A 








Data bus input Layer 4 data Layer 4 data Layer 4 data CRC result ) 





—= ÌlWRWR2 =— 





tIWRRD1 





Figure 4.3 Layer 4 CRC mode and Layer 4 VICS mode Timing 





Address input 0x3B X 0x3C X 0x3D x 0x38 





—= ЂУРИЋ =— 





Р —— i 


tiwrRD 





Figure 4.4 Internal between write and write or between write and read 





0x3D 0x3D 
0x3C 0x3C 
Address input Ox3B ES 0x3B 





—= lIWRWRI = 


Figure 4.5 When 0x3B to 0x3D are continuously written at the same address (This is a rare 
case) 


MSM9563 User's Manual 
Chapter 4 ELECTRICAL CHARACTERISTICS 





Address input xX X X 


— ÌIRDRD i-— 





RD 





Figure 4.6 Intarval between read and read 





Address signal input x 0x00 x 








Data signal input XXXX01XX 





WR input (INTCLR signal) 


— ¡a— 


TNT output ÍpiNTCLR ў - 





Figure 4.7 Interrupt CLR Timing 


O 





LR signal \ Y 


tweLR — — 


Figure 4.8 Clear pulse width 


MSM9563 User's Manual 
Chapter 4 ELECTRICAL CHARACTERISTICS 


4-8 


Chapter 5 





CONTROL REGISTERS 


5. CONTROL REGISTERS 


5.1 OPERATING MODE REGISTERS 


MSM9563 User's Manual 
Chapter 5 CONTROL REGISTERS 


5.1.1 Mode setting of main channel and subchannel 


Table 5.1.1 Main channel mode and subchannel mode 











Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 

W — — — MOD... — — — MOD... 

0x04 SUB MAIN 
Initial value — — — 0 — — — 1 
































There are two modes available, namely, the main channel mode in which connection is made to 
the broadcasting station of the same channel and reception is made in units of a frame (the 
conventional method), and the subchannel mode in which the tuner is switched intermittently to 
other channels and reception is made in units of several packets of information. 

The channel switching mode setting for simultaneously receiving subchannels by switching to 
high speed subchannel during main channel reception is shown in the following table. 


Channel switching mode setting for simultaneous reception of main channel and subchannels. 




















Mode че walle Description 
DB4 DBO 

MOD_MAIN/SUB 1 1 The mode used for subchannel timing extraction (at the time of 
initial setting). 

MOD_MAIN 0 1 Main channel reception mode 

MOD_SUB 1 0 Subchannel reception mode 

MOD_OFF 0 0 The mode used for isolating the synchronization circuit after tuner 
switching until the tuning becomes stable. 














5.1.2 Frame format 


Table 5.1.2 Frame format 



























































Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
W — — — — — — B1 BO 
Ox1F — 
Initial value — — — — — — 1 0 
Set value Frame 
. А Symbol Remarks 
DB1 DBO configuration 
0 0 Format A A0 
0 1 A1 Includes real time information blocks 
1 0 Format B B Used in Japan 
1 1 Format C C 

















5-1 


eS 


Sub eee] 


Tuner switching 
_MAIN/SUB 


Tuner 


| | Data 
Кою ш reproduction 
Main station ' 





Timing 


— interrupt SUB 
(R. 00) 





Channel connection/ 


Timer. SUB 


Bus 











disconnection _SUB 
(R_04) 


| 





& | 



































































































































Clock regeneration Block synchronization 
г—о _SUB _SUB 
Receive 
Receive RAM after first (L1BF_SUB) RAM switching 
horizontal error correction _SUB "d (R_02) 
Xo 
Receive RAM after first 
horizontal error correction MAIN (L1BF) 
Frame memory 
Clock regeneration Block synchronization Frame synchronization 
ко MAIN рч MAIN 7 _MAIN 
Channel connection/ | | ' 
disconnection MAIN 
(R-04) Timer MAIN 
Timing 
[interrupt MAIN 


MSM9563 





Figure 51 Main/Subchannel switching receive block diagram 





jenueyy S.19SN E9SGINSIN 


SH31SIO3H TOHINOD Ф 491deyo 


5.1.3 Page mode 


Table 5.1.3 Page mode 


MSM9563 User's Manual 
Chapter 5 CONTROL REGISTERS 











Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
W — MAINCH — MOD. |CLRMCO| MOD | РАСЕІ | PAGEO 
Ox3E (Note) _CLRB PARITERC2| _PAGE PAGE 
Initial value = 0 == 0 0 0 0 0 
































Note: 


The settings MOD 508-1 and MOD MAIN-O should be made in the register 0x04. 


By setting the page mode, it is possible to automatically accumulate the received data after the 
first horizontal error correction in the frame memory. However, the frame synchronization, vertical 
error correction, and the second horizontal error correction are not made in the page mode. 

The frame memory can be divided into the receive data accumulation area after first horizontal 
error correction and the user area, and the sizes of the two areas are variable. 
DB3: The received packets are written startig from the packet address "0" if CLRMCO PAGE is 


set to "1". 


Frame memory configuration (page mode) 








Receive data accumulation area after 
the first horizontal error correction 


User area 





Receive data accumulation area after the first horizontal error correction and user area 


























Register 0x3E Receive data accumulation area User area 
set value after the first horizontal error correction 
0x04 Packets 0 to 31 Packets 32 to 272 
0x05 Packets 0 to 63 Packets 64 to 272 
0x06 Packets 0 to 127 Packets 128 to 272 
0x07 Packets 0 to 271 Not present 








5-3 


MSM9563 User's Manual 
Chapter 5 CONTROL REGISTERS 


5.1.4 


Main channel clear bit (MAINCH_CLRB) 


This MAINCH CLRB bit (DB6 of register OX3E) has been provided to speed up switching to the 
main channel. When this bit is set to "1" (MAINCH CLRB, BIT 6 =1), the main channel 
synchronization, error correction, internal frame memory control section, and interrupt will be 
reset. 

However, the parameter setting registers, the counter for synchronization, and the pointer for 
reading out the frame memory are not cleared. Since the reset condition is retained, after 
switching the tuner, reset this bit to "0" (MAINCH CLRB, DB6=0) thereby releasing the reset 
condition. 

Thereafter, reception starts even if the register is not set again. 

Although the frame memory is not cleared, the new receive data will be written over the old ones. 







Main channel 
tuner switching 





Main channel clearing 











R_3E=0x40 


і 


Tuner switching 





і 


Main channel 
reset release 


В 3bE-0x00 














End 


MSM9563 User's Manual 
Chapter 5 CONTROL REGISTERS 














5.2 INTERRUPT REGISTERS 
5.2.1 Interrupt register 
When an interrupt occurs, а "1" is written in this register and the INT Pin is set to the "0" level. After 
reading out this register, write a "1" in the corresponding bit of this register to clear the interrupt. 
Table 5.2.1 Interrupt register 
Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
R Receive interrupt TIMINT . TIMINT . Receive interrupt == Out-of- Receive interrupt REAL 
fter the fi fter the second ization after the fi 
eee SUB MAIN к Synchronization А Packet 
0x00 correction SUB correction interrupt correction MAIN 
W Clear interruptClear interruptClear interruptiClear interrupt — Clear interruptClear interrupt | — 
Initial value 0 0 0 0 = 0 0 0 
































(1) ОВУ: Receive interrupt after the first horizontal error correction SUB 


1: Indicates that a packet was received in a subchannel. 
0: There is no interrupt in the subchannels. 


(2  DB6: TIMINT SUB 


1: Indicates that an interrupt set by the subchannel timer has occurred. 
0: There is no interrupt in the subchannels. 


(3  DB5: TIMINT MAIN 


1: Indicates that an interrupt set by the main channel timer has occurred. 
0: There is no interrupt in the main channel. 


Settings of the registers 0x05, 0x16, 0x17, Ox1D, and Ox1E are necessary to activate the main 
channel timer interrupt. 


(4) DB4: Receive interrupt after the second horizontal error correction 

1: Indicates that an interrupt of the frame data reception after the second horizontal error 
correction of the main channel has occurred. 

0: There is no interrupt in the main channel. 


(5 DB2: Out-of-synchronization interrupt 


1: Indicates that an interrupt of frame out-of-synchronization has occurred. 
0: There is no interrupt in the main channel. 


(б) DB1: Receive interrupt after the first horizontal error correction MAIN 


1: Indicates that a packet was received in the main channel. 
0: There is no interrupt in the main channel. 


5-5 


MSM9563 User's Manual 
Chapter 5 CONTROL REGISTERS 


(7) DBO: REAL 

This bit is not an interrupt. 

This bit is cleared simultaneously with the receive interrupt after the first horizontal error correction 
МАІМ when а "1" is written in DB1. 


1: Indicates that the received packet is a REAL packet. 
0: The received packet is not a REAL packet. 


5.2.2 Interrupt mask 


This is a register that controls the interrupts corresponding to the bit numbers of the interrupt 








register (0x00). 
Table 5.2.2 Interrupt mask 
Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
0x01 W Interrupt mask | Interrupt mask | Interrupt mask | Interrupt mask — Interrupt mask | Interrupt mask = 
Initial value 0 0 0 0 — 0 0 — 
































1: Interrupt enabled. 
0: Interrupt disabled. 


5.3 


5.3.1 


MSM9563 User's Manual 
Chapter 5 CONTROL REGISTERS 


RECEIVE DATA REGISTERS 


When data is received, that fact is reported by generating an interrupt and setting the INT pin to 
the "0" level, after which the received data should be read out from the receive data port. The 
receive data ports are the recive port (0x03) after first horizontal error correction from which data 
should be read out in units of a packet after the first horizontal error correction has been 
completed, and the receive port (0x38) after second horizontal error correction from which data 
can be read out in units of a frame after the second horizontal error correction has been completed. 


Receive port after the first horizontal error correction 

Since the receive port after the first horizontal error correction is internally separated into one for 
the main channel and one for the subchnnel, it is necessary to select the required port before 
reading data. The receive data interrupt after the first horizontal error correction can be set to be 
enabled or disabled according to the conditions of parity packet, error correction result, service 
identifier, etc. 





Receive port after the second horizontal error correction 

The receive data of the receive port after the second horizontal error correction is reported by an 
interrupt at the timing of the 13th packet of the next frame. When all the packets of the frame have 
been received, the vertical error correction would have been completed. However, the vertical 
error correction would have been omitted when all the packets in the frame have not been 
received, such as when frame synchronization is entered in the middle of a frame. The second 
horizontal error correction is carried out for the packet received under frame synchronization and 
its result is indicated in register 0x37 by dividing it into four groups as the frame synchronization 
condition. 

The test settings described later are necessary for reading the received data including the parity 
packet, and in this case, the reception is reported by an interrupt generated at the timing of the 
15th packet. Before reading data from the receive port afterthe second horizontal error correction, 
itis necessary to set the address pointer (ОХЗВ to Ox3D) and the access mode (0x39) of the frame 
memory. The address pointer consists of the packet number and the byte number, and specifies 
the starting address of reading. The setting of the access mode consists of setting the modes of 
horizontal/vertical reading direction, the parity read, etc., of the frame memory. 

The frame data (for example, 190x24 bytes) of the receive port after the second horizontal error 
correction can be read out either successively or intermittently. 





Switching the receive port after the first horizontal error correction 


Table 5.3.1 Switching the receive port after the first horizontal error correction 


Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 





0x02 


W — — — — — — — MAINB/ 
SUB 


Initial value — — — — — — = 0 



































Since the receive port after the first horizontal error correction is connected to the 36-byte RAM 
for the main channel (LIBF) and the RAM for the subchannel (LIBF_SUB) (see Figure 5.1), it is 
necessary to switch between them according to the content of the receive interrupt register. When 
a value is set in this register, the RAM address pointer is reset and it is possible to read from the 
leading byte. 


5-7 


MSM9563 User's Manual 
Chapter 5 CONTROL REGISTERS 


DBO: MAINB/SUB 


1: The receive port after the first horizontal error correction is connected to the RAM (LIBF. SUB) 
for the subchannel. 

0: The receive port after the first horizontal error correction is connected to the RAM (LIBF) for the 
main channel. 











5.3.2 Receive port after the first horizontal error correction and the receive data format 
Table 5.3.2.1 Receive port after the first horizontal error correction 
Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
R B7 B6 B5 B4 B3 B2 B1 BO 
0x03 W B7 B6 B5 B4 B3 B2 B1 BO 
Initial value — — — — — — — — 
































Read 

This is the one-packet receive data port after the first horizontal error correction. The read address 
ofthe internal RAM is "0x00" when a receive interrupt after the first horizontal error correction has 
occurred. When this port is read, the read address is automatically incremented to the next read 
address and hence it is possible to carry out successive reads. 


Write 
For testing only. Writing to this port is prohibited during normal use. 


Table 5.3.2.2 Receive data format after the first horizontal error correction 





Bit No. 





DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 








BYTEO CRCO ERCO | RECCRC | FSYNC | BSYNC | BICDET BIC1 BICO 





BYTE1 VICSRDY | PARITY INTO 0 0 FNCHG | FRNO1 | FRNOO 





























BYTE2 First horizontal correction receive data No. 0 








Byte No. BYTE23 First horizontal correction receive data No. 21 





BYTE24 CRC 





BYTE25 PARITY CRC 











BYTE26 PARITY 











BYTE35 PARITY 





BYTEO and BYTE1 of the receive RAM data after the first horizontal error correction indicate the 
status of the received packet, BYTE2 to BYE23 are data, and BYTE 24 to BYTE 35 are the CRC/ 
parity data. 

BYTE24 to BYTE35 are for testing and cannot be read out. 





MSM9563 User's Manual 
Chapter 5 CONTROL REGISTERS 


BYTEO 
(1) DB7: CRCO 


1: Indicates that there is an error in the CRC of the packet after the first horizontal error correction. 
0: Indicates that the CRC of the packet is normal after the first horizontal error correction. 


(2)  DB6: ERCO 

1: Indicates that there is an error in the correction result of the packet after the first horizontal error 
correction. 

0: Indicates that the correction result of the packet is normal after the first horizontal error 
correction. 


(3) 085: RECCRC 


1: Indicates that there is ап error in the CRC of the received packet before error correction. 
0: Indicates that the CRC of the received packet is normal before error correction. 


(4) 084: FSYNC 


1: Indicates that the received packet is п a frame synchronization state. 
0: Indicates that the received packet is in a frame out-of-synchronizaiton state. 


(5). DB3: BSYNC 


1: Indicates that the received packet is in a block synchronization state. 
0: Indicates that the received packet is in a block out-of-synchronization state. 


(6) DB2toDB0: BIC Data 


Indicate the detection condition of the block identification code (BIC). 
































DB2 DB1 DBO |BIC No. 
1 0 0 1 
1 0 1 2 
1 1 0 3 
1 1 1 4 
0 — E Not detected 








BYTE1 
(1) DB7: VICSRDY 


1: Indicates that the received packet is a VICS packet. 
0: Indicates that the received packet is not a VICS packet. 


(2  DB6: PARITY 
This bit indication is made only in a frame synchronization state. 


1: Indicates that the received packet is a parity packet. 
0: Indicates that the received packet is not a parity packet. 


5-9 


MSM9563 User's Manual 
Chapter 5 CONTROL REGISTERS 


(3 DB5: INTO 


This bit indicates the receive interrupt after the first horizontal error correction. Even though this 

bit indication is made in the reception condition after the second horizontal correction, it is 

possible to confirm that reading has been made when a receive interrupt has occurred after the 

first horizontal error correction. 

1: Indicates that the received packet is one in which the receive interrupt occurred after the first 
horizontal error correction. 

0: Indicates that the received packet is one in which no receive interrupt occurred after the first 
horizontal error correction. 


(4 DB4, DB3: "0" fixed 
(5 DB2: FNCHG 
This bit indication is made only in a frame synchronization state. 


1: Indicates that the packet is one given in the following table. 
0: Indicates that the packet is one other than those indicated in the following table. 














Frame format 
Format B Format A1, А 
Packet with a block number of 0, 13, 136, | Packet with a block number of 0, 60, 130, 
or 149. or 190. 








Note: | The packet numbers are expressed in this manual as 0 to 271 (A1: O to 283). 


(б) DB1, DBO: FRNO1, FRNOO 


These bit indications are made only in a frame synchronization state. 
These bits indicate that the packet is one with the block numbers given in the following table. 









Frame format 
DBO Format B Format A1, A0 

Packet with a block number of 0 to 12. Packet with a block number of 0 to 59 
Packet with a block number of 13 to 135. | Packet with a block number of 60 to 129 
Packet with a block number of 136 to 148. | Packet with a block number of 130 to 189 


Packet with a block number of 149 to 271. Packet with a block number of 190 to 271 


Packet with a block number of 190 to 283 













































Note: Тһе packet numbers are expressed in this manual as 0 to 271 (A1: O to 283). 


5-10 


MSM9563 User's Manual 
Chapter 5 CONTROL REGISTERS 


5.3.3 Conditions of receive interrupt after the first horizontal error correction 


Table 5.3.3.1 Conditions of receive interrupt after the first horizontal error correction 








Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
W MOD |MODCH| MOD | MOD | MOD | MOD | MOD. SISEL 
0x34 FSYNC | OFFDET | INTO ERCO | PARITO | BICDETO 51 
Initial value 0 0 1 0 0 0 0 0 
































This is the register for setting the conditions of interrupt after the first horizontal error correction. 
During the initial setting, all packets received in a synchronization state are set to generate an 
interrupt. Itis possible to specify the four types of interrupt conditions shown in the following table 
regarding good (error-free) packets, frame synchronization, and specified SI (service identifier). 
It is possible to specify 16 types of service identifiers (SIO to 5115) for which it is necessary to set 
this register and the register 0x35. 

The packets that generated an interrupt after the first horizontal error correction are recorded in 
the frame memory (Receiving state 1 DB5 (INTO)) after the second horizontal error correction. 
Therefore, there is no need to read out good packets after the first horizontal error correction after 
the second horizontal error correction. 


Table 5.3.3.2 Interrupt conditions after the first horizontal error correction 





Interrupt condition Set value Set value of 0x35 
of 0x34 
1 |All packets received in a synchronization state 0x20 — 
2 | Good packets received in a synchronization state} | 0x70 — 

















Packets in a frame synchronization state ОХАО — 
(including bad packets) 

4 | Good packets with the specified service 0x7A | 510 to SI7 written in units of a bit 
identifier SI. Ox/B |518 to 5115 written in units of a bit 

















MSM9563 User's Manual 
Chapter 5 CONTROL REGISTERS 





















































5.3.4 Specification of SI (Service identifier) 
Table 5.3.4 SI Specification 
Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
W SI7 516 515 54 513 512 51 510 
(Note 1) 
0x35 W 515 514 513 512 5111 5110 519 518 
(Note 2) 
Initial value 1 1 1 1 1 1 1 1 
Note 1: The setting SISEL=0 should have been made in the register 0x34. 
Note 2: The setting SISEL=1 should have been made in the register 0x34. 
This is the register for setting the service identifier SI which is an interrupt condition after the first 
horizontal error correction. 
It is possible to specify multiple service identifiers by setting "1" to the bits corresponding to the 
required service identifiers among the 16 types SIO to 515 in the above table. 
5.3.5 Receive port after the second horizontal error correction 
Table 5.3.5 Receive data port after the second horizontal error correction 
Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
R B7 B6 B5 B4 B3 B2 B1 BO 
0x38 W B7 B6 B5 B4 B3 B2 B1 BO 
Initial value — — — — — — — — 
































The receive port after the second horizontal error correction is connected to the frame memory. 
It is possible to read the frame memory successively since the frame memory address is 
incremented automatically whenever this port is read. It is also possible to read this port starting 
from any required address. 

Packets in a frame synchronization state are accumulated in the frame memory. When the 
reception of one full frame is completed, the vertical error correction and the second horizontal 
error correction are made, and the receive interrupt after the second horizontal error correction 
occurs at the timing of the 13th packet in the next frame. 

Although it is possible to receive from the middle of a frame, the vertical error correction will be 
omitted in that case. The frame synchronization state is indicated in the register 0x37 by dividing 
it into four groups. On the other hand, it is also possible to know this from the status indication 
byte at the beginning of each packet. 

The volume of data in the frame memory is; 

* 24x190 bytes in the case of 4-layer data including packet status indication; 

• 36x273 bytes in the case of data including parity, etc. 

See the data format of the receive frame memory after the second horizontal error correction in 
Section 5.3.6 for the detailed contents of data. 


CAUTION: The frame memory has segments that are prohibited from being accessed. 
See Figure 5.3 for details. 


5-12 


MSM9563 User's Manual 
Chapter 5 CONTROL REGISTERS 


Figure 5.3 Access prohibited segments of the frame memory (R 38) 


(1) Theframe memory access inhibited time occurs when the intersection of the packet number 
and the byte number correspond to the hatched parts in the follwoing figure. 

(2) Itis possible to know the packet number and the byte number by reading out the registers 
В ЛЕ, В 1D, В 16, and В 17. (See the precautions to be taken at the time of reading out 
the packet number and byte number given in the next page.) 


Byte number 
«В 17[DBO],R. 16[DB7..DB3]» 


0|1[2[3]4] —— 33 [34 | 35 


Packet number 
<R_1E[DB0],R_1D[DB7..DB0]> 


























































































гт WN 

ИА 
гт YN 

NN 
: У... 

ИМ Ў О О О 

й AN Y HONI 
9 Y АЎ RRR RRR RRR 

ААА SRNR mr 
EE EE Memory access inhibited 

ME segment due to vertical and 

NETT | Second horizontal error 
11 AN PWY RRR ERIK RRR RRR RR corrections 

р /N USA жая жа AQUA AQUA ХХХ 
TRAN 

р, AN Y A 

= Receive interrupt after the second 

horizontal error correction 











=> Memory access inhibited segment due to the first horizontal 
error correction (when using only the main channel) 
-—— —» Memory access inhibited segment due to the first horizontal error 
correction (when receiving by switching between main and sub channels) 


5-13 


MSM9563 User's Manual 
Chapter 5 CONTROL REGISTERS 


Precautions in reading the packet number and byte number 


Since the microcontroller and data clocks are not mutually synchronized, it is possible that wrong 
values are read out when reading out is made when the packet number or the byte number is 
changing. Therefore, it is necessary to read them twice successively and use only after confirming 
that there is a match between the two successive values. 


(1) Memory access is possible for about (2) Checking the byte number and 
16msec after the timing interrupt the packet number of Figure 5.3 





Timing interrupt 
setting 





Timing interrupt 
setting 














Second horizonta 
correction receive 
interrupt 





Second horizonta 
correction receive 
interrupt 












FLG_ERC2=1 








Timing interrupt 
setting MAIN 


R_05=0x01 


| 


Byte number 2 
setting MAIN 


R_16=0x10 
R_17=0x00 


| 


Timing interrupt setting 
— MAIN for each packet 

















Timing interrupt 
setting 
















































R_1E=0x02 Byte number 
| read МАІМ 
Timing interrupt 
EN_MAIN 
R_05=0x02 First read = second read 









| 


Timing interrupt 
setting 





1 < Byte number < (34- 


Y 
Access possible Access possible 


n is the time of 
accessing the memory 











5-14 


MSM9563 User's Manual 
Chapter 5 CONTROL REGISTERS 


5.3.6 Data configuration of the receive frame memory after the second horizontal error 
































correction 
Table 5.3.6.1 Receive frame memory data configuration after 
the second horizontal error correction 
Byte No. 
Packet No. 0 1 2 23 24 35 
Reception | Reception Data 0 Data 21 CRC/ PARITY 
0 status 0 | status 1 PARITY 
Reception | Reception Data 0 Data 21 CRC/ PARITY 
189 status 0 | status 1 PARITY 
Reception | Reception | Vertical Vertical Vertical Vertical Vertical Vertical 
190 tatus 0 tatus 1 correction | correction | correction | correction | correction | correction 
Status Status parity parity parity parity parity parity 
Reception | Reception | Vertical Vertical Vertical Vertical Vertical Vertical 
271 tatus 0 tatus 1 correction | correction | correction | correction | correction | correction 
status status parity parity parity parity parity parity 
— — Vertical Vertical 
272 correction correction 
result result 33 





























The frame memory data configuration is shown in Table 5.3.6.1. The data consists of 190 data 
packets, 82 parity packets, and one vertical correction result packet. Normally, the second 
horizontal error correction of the parity packets 190 to 271 are omitted. To read packets including 
the parity packets after the second horizontal error correction, it is necessary to set and carry out 
the error correction separately for testing purposes. 

The leading two bytes of each packet indicate the reception status. 

The details of the reception status are shown in Table 5.3.6.2. 


Table 5.3.6.2 Reception status after the second horizontal error correction 




















DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
Reception status 0 CRCO ERCO | RECCRC | FSYNC | BSYNC | BICDET BIC1 BICO 
Reception status 1 VICSRDY | PARITY INTO CRC2 ERC2 FNCHG | FRNO1 | FRNOO 

















Reception status 0 
The reception status 0 is equal to the contents of BYTEO received after the first horizontal error 
correction. 





(1) DB7: CRCO 

1: Indicates that there is an error in the CRC of the packet after the first horizontal error correction. 

0: Indicates that the CRC of the packet is normal after the first horizontal error correction. 

(2)  DB6: ERCO 

1: Indicates that there is an error in the correction result of the packet after the first horizontal error 
correction. 

0: Indicates that the correction result of the packet is normal after the first horizontal error 
correction. 


MSM9563 User's Manual 
Chapter 5 CONTROL REGISTERS 


(3) 085: RECCRC 


1: Indicates that there is an error in the CRC of the received packet before error correction. 
0: Indicates that the CRC of the received packet is normal before error correction. 


(4) DB4: FSYNC 


1: Indicates that the received packet is in a frame synchronization state. 
0: Indicates that the received packet is in a frame out-of-synchronizaiton state. 


(5 083: BSYNC 


1: Indicates that the received packet is in a block synchronization state. 
0: Indicates that the received packet is in a block out-of-synchronization state. 


(6) DB2 їо DBO: BIC Monitor 


Indicate the detection condition of the block identification code (BIC). 























DB2 DB1 DBO | BIC No. 
1 0 0 1 
1 0 1 2 
1 1 0 3 
1 1 1 4 
0 — — Not detected 

















Reception status 1 
(1) DB7: VICSRDY 





1: Indicates that the received packet after the second horizontal error correction is a VICS packet. 
0: Indicates that the received packet after the second horizontal error correction is not a VICS 
packet. 


(2) 086: PARITY 


This bit indication is made only in a frame synchronization state. 
1: Indicates that the received packet is a parity packet. 
0: Indicates that the received packet is not a parity packet. 


(3 DB5: INTO 


1: Indicates that the received packet is the one in which the receive interrupt occurred after the 
first horizontal error correction. 
It is not necessary to read this if the reading has already been done during the reception after 
the first horizontal error correction. 

0: Indicates that the received packet is one in which no receive interrupt occurred after the first 
horizontal error correction. 


5-16 


MSM9563 User's Manual 
Chapter 5 CONTROL REGISTERS 


(4) DB4: CRC2 


1: Indicates that there is an error in the CRC of the packet after the second horizontal error 
correction. 
0: Indicates that the CRC of the packet is normal after the second horizontal error correction. 


(5 DB3: ERC2 


1: Indicates that there is an error in the correction result of the packet after the second horizontal 
error correction. 

0: Indicates that the correction result of the packet is normal after the second horizontal error 
correction. 


Note: CRC2=ERC2=0 is necessary for the packet to be good (error-free). 

(6) DB2: FNCHG 

This bit indication is made only in a frame synchronization state. 

1: Indicates that the packet is one with a block number of 1, 14, 137, or 150 in the case of the frame 
format B, and with a block numaber of 1, 61, 131, or 191 in the case of the frame formats AO 
and A1. 

0: Indicates that the packet is one other than the above. 


(7) | DB1, DBO: FRNO1, FRNOO 


These bit indications are made only in a frame synchronization state. 
These bits indicate that the packet is one with the block numbers given in the following table. 





Frame format 

DB1 | DBO Format B Format A1, A0 

Packet with a block number of 0 to 12. Packet with a block number of 0 to 59 
Packet with a block number of 13 to 135. | Packet with a block number of 60 to 129 
Packet with a block number of 136 to 148. | Packet with a block number of 130 to 189 


1 Packet with a block number of 149 to 271. | AO | Packet with a block number of 190 to 271 
A1 | Packet with а block number of 190 to 283 


Note: | The packet numbers are expressed in this manual as O to 271 (A1: O to 283). 














0 
0 
1 


о — о 




















MSM9563 User's Manual 
Chapter 5 CONTROL REGISTERS 


5.3.7 | Setting the receive frame memory access mode after the second horizontal error 
correction 


Table 5.3.7 Frame memory access mode 











Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
W BANK BANK | VLBCNT | PCTL1 | VBACK | LBACK1 | LBACKO | LSTART 
0x39 CONT1 | CONTO BL2 
Initial value 0 0 0 0 0 1 0 0 
































This is the register for setting the access mode so that reading can be done efficiently when 


reading the frame memory successively. 


(1) ОВУ, DB6: BANK1, BANKO 


These bits are for making settings for testing purposes. Normally use with the settings of 


DB7=DB6=0. 


(2) DB5: VLBCNT 


1: The frame memory is read in the vertical direction (in an ascending order ofthe packet number 


with the byte number being kept fixed). 


0: The frame memory is read in the horizontal direction (in an ascending order ofthe byte number 


with the packet number being kept fixed). 


The packet number is incremented by 1 when the byte number reaches that specified by 


LBACKO and LBACK1. 


(3  DB4: PCTL1BL2 


The readable frame memory address (packet number) is selected from the registers OX3C and 


0x3D. 


1: Enables the MSM9563 to read the address (packet number) of the receive data packet that is 


being written. 


0: Enables an external microcontroller to read the address (packet number) of the receive data 


packet that is being accessed. 


(4) DBS: VBACK 


1: When the packet number becomes 272, the next packet number will be reset to 0. For testing 


purposes only. 
0: When the packet number becomes 189, the next packet number will be reset to 0. 


(5) DB2, DB1: LBACK1, LBACKO 


The next byte number is reset to the byte number specified by LSTART when the current byte 


number becomes the returning byte number given in the following table. 

















LBACK1 (ВАСКО Returning byte No. 
0 0 1 
0 1 2 
1 0 23 
1 1 35 

















(69 DBO: LSTART 


1: The next byte number is reset to 2 when the current byte number becomes equal to the value 


specified by LBACKO and LBACK1. 


0: The next byte number is reset to 0 when the current byte number becomes equal to the value 


specified by LBACKO and LBACK1. 
5-18 


5.3.8 Receive frame memory pointer after the second horizontal error correction 


Table 5.3.8.1 Frame memory address (1/3) 


MSM9563 User's Manual 
Chapter 5 CONTROL REGISTERS 



































































































































Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
R/W — — EXT EXT EXT EXT EXT EXT 
0x3B BYTES | BYTE4 | BYTES | BYTE2 | BYTE! BYTEO 
Initial value = _ 0 0 0 0 0 0 
Table 5.3.8.2 Frame memory address (2/3) 
Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
R EXT EXT EXT EXT EXT EXT EXT EXT 
(Note 1) PCT7 PCT6 PCT5 PCT4 PCT3 PCT2 PCT1 PCTO 
R L1BF L1BF L1BF L1BF L1BF L1BF L1BF L1BF 
0x3C (Note 2) PCT7 PCT6 PCT5 PCT4 РСТЗ PCT2 РСТ РСТО 
W EXT EXT EXT EXT EXT EXT EXT EXT 
PCT7 PCT6 PCT5 PCT4 PCT3 PCT2 PCT1 PCTO 
Initial value 0 0 0 0 0 0 0 0 
Note 1: The setting PCTL1BL2=0 should have been made in the register 0x39. 
Note 2: Thesetting PCTL1BL2=1 should have been made in the register 0x39 (used in the page 
mode). 
Table 5.3.8.3 Frame memory address (3/3) 
Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
R MEMSTAT — — — E — — EXT 
(Note 1) PCT8 
R = = = = = = = L1BF 
0x3D (Note 2) PCT8 
W — x: — — = m m EXT 
PCT8 
Initial value = — = — “ — — 0 
Note 1: The setting PCTL1BL2-0 should have been made in the register Ox39. 


Note 2: The setting PCTL1BL2=1 should have been made in the register 0x39. 


Write 

Before reading from the receive port after the second horizontal error correction of the register 
0x38, it is necessary to set the packet number and the byte number in the register. Specify the 
packet number of the starting byte and the starting byte number of the data to be read according 
to Table 5.3.6.1 "Data configuration of the receive frame memory after the second horizontal error 
correction". 

Thereafter successive reads will be possible according to the "Access mode setting of the receive 
frame memory after the second horizontal error correction". 





MSM9563 User's Manual 
Chapter 5 CONTROL REGISTERS 


Read (PCTL1BL2-0) 

Itis possible to know the byte number and the packet number of the data to be read next by reading 
these registers Ox3B, Ox3C, and Ox3D. 

However, it is necessary to set PCTL1BL2 of the register Ox39 to "0". Before reading these 
registers. 





Read (PCTL1BL2=1) 
The registers Ox3C and 0x3D indicate the frame memory address (packet number) of the data 
packet received after the first horizontal error correction, which is to be written next. 

















5.3.9 Reception status of the receive frame memory after the second horizontal error correction 
Table 5.3.9 Frame synchronization status 

Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 

R BANK — — — BANK BANK BANK BANK 
_ЕВСЕВО | _ERCFR1 | _ERCFR2 | _ERCFR3 

0x37 W — BANKLT | MOD  EXPCTCNT BANK BANK BANK BANK 
_CLR EXERC | STARTB | ERCFRO |. ERCFR1 | ERCFR2 |. ERCFR3 

Initial value — 0 0 0 0 0 0 0 
































Read 
(1) DBO to DB3: BANK ERCFR3 to BANK ERCFRO 


When data is read after a receive interrupt after the second horizontal error correction, these four 
bits indicate whether the four packet groups listed in the following table are in a frame 
synchronization state or not. 

The vertical error correction is carried out only when DBO=DB1=DB2=DB3=1. The second 
horizontal error correction is carried out only for the concerned packet group among DBO to DB3. 
However, a separate setting and implementation of error correction for testing are required in the 
case of parity packets. 





Frame format 
Format B Format A1, A0 
083 | Packet with a block number of 0 to 12. АО, A1 | Packet with a block number of 0 to 59 
082 | Packet with a block number of 13 to 135. | AO, A1 | Packet with a block number of 60 to 129 
DB1 | Packet with a block number of 136 to 148. | AO, АТ | Packet with a block number of 130 to 189 
DBO | Packet with a block number of 149 to 271. | АО | Packet with a block number of 190 to 271 
A1 |Packet with a block number of 190 to 283 



































Note: The packet numbers are expressed in this manual as 0 to 271 (A1: 0 to 283). 
(2) DB7: BANK 

For testing purposes only. 

Write 


This register is for making settings for testing and writing is prohibited under normal use. 


5-20 


5.4 


MSM9563 User’s Manual 
Chapter 5 CONTROL REGISTERS 


TIMING INTERRUPT REGISTERS 


There are the two timing interrupts of TIMINT_MAIN which operates in synchronization with the 
main channel and the timing interrupt TIMINT_SUB which operates in synchronization with the 
subchannel. 

The block diagram of TIMINT_MAIN is shown in Figure 5.4.1. 

The timing interrupt TIMINT_MAIN occurs when the packet number and byte number of the main 
channel match with the set interrupt timing. 


The block diagram of TIMINT_SUB is shown in Figure 5.4.2. 

The timing interrupt TIMINT_SUB occurs when the packet number, byte number, and frame 
number of the subchannel match with the set interrupt timing. It is possible to set TIMINT_SUB 
at intervals of 0 to 15 frames. 

Itis necessary to carry out initial setting of the timing of the packet number and frame number when 
synchronized with a subchannel. 


Bus 





Setting of FRCK_MAIN TIMINTEN_MAIN 
and BCK_MAIN 





Timing interrupt 
setting register 














Compare | TIMINT_MAIN 
& и 


enable 




















Packet and 
byte counter 











Data clock _MAIN 





Figure 5.4.1 TIMINT_MAIN block diagram 


























Bus 

INTFRCK_SUB, and B 
INTBCK SUB M 

Timing interrupt 

setting register 
Setting of MAXFNCK. SUB, Compare | | ТІМІМТ SUB 
FNCK SUB, and FRCK SUB & A 

enable 























BCK_SUB Adjustment Frame, packet 


and byte counter 





— » | 


Data clock _SUB 











Figure 5.4.2 TIMINT_SUB block diagram 


5-21 


MSM9563 User's Manual 
Chapter 5 CONTROL REGISTERS 


5.4.1 Timing interrupt mode 


Since some of the interrupt timing registers have been mapped to the same address, this register 
controls their selection and timing enable conditions. 


Table 5.4.1 Interrupt timing mode 











Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
W — — |TIMINTEN| SETCK1 | SETCKO | RDBSCK — TIMINT | SETINT 
0x05 _SUB _SUB _SUB _SUB EN_MAIN | CK_MAIN 
Initial value — 0 0 0 0 — 0 0 
































(1) DB6: ТІМІМТЕМ SUB 


1: Activates the timing interrupt of the subchannel. 

0: Disables the timing interrupt operation of the subchannel 

Set the interrupt timing after making this bit "0" and change this bit to "1" after the setting is 
completed. 


(2) DB5,DB4: SETCK1 SUB, ЗЕТСКО SUB 





DB5 | DB4 Set mode Description 

1 1 | SETMAX_SUB Enables the setting of a count value of the maximum number of 
frames in the register 0x09. 
1 0 |SETINTCK SUB | Enables the setting of the interrupt timing value in the registers 
0x06 to 0x09. 
0 1 TSETTIMCK SUB | Enables the setting of the initial value of the timer counter in the 
registers 0x08 to 0x09. 


























(3 DB3: RDBSCK SUB 


1: Makes it possible to read the block counter value of the subchannel. 
0: Makes it possible to read the block counter value latched immediately before block synchro- 
nization of the subchannel. 


(4) DB1: TIMINTEN MAIN 

1: Activates the timing interrupt of the main channel. 

0: Disables the timing interrupt operation of the main channel. 

Set the interrupt timing after setting this bit to "O", and set this bit to "1" after the interrupt timing 
setting is completed. 

(5) DBO: SETINTCK MAIN 

1: Makes it possible to write the main channel interrupt timing values in the registers 0x16, 0x17, 


Ox1D, and Ox1E. 
0: It is not possible to write the main channel interrupt timing values in the registers. 


5-22 


MSM9563 User's Manual 


Chapter 5 CONTROL REGISTERS 






































































































































5.4.2 Interrupt byte number specification (main channel) 
Table 5.4.2.1 Interrupt timing MAIN (byte number 1/2) 
Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
R BCK7 BCK6 BCK5 BCK4 BCK3 BCK2 BCK1 BCKO 
0x16 W INTBCK7 | INTBCK6 | INTBCK5 | INTBCK4 | INTBCK3 — = — 
(Note 1) 
Initial value 0 0 0 0 0 0 0 0 
Note 1: The setting SETINTCK-1 should have been made in the register 0x05. 
Table 5.4.2.2 Interrupt timing MAIN (byte number 2/2) 
Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
R == = Е = = — = BCK8 
0x17 W — — — = — — s INTBCK8 
(Note 1) 
Initial value — — — — — — — 0 
Note 1: The setting SETINTCK-1 should have been made in the register 0x05. 
Read 
BCK8 (MSB) to BCKO (LSB) indicate the bit numbers of the packet being received. The upper 6 
bits indicate the byte number. 
Write 
This is the register for specifying the main channel interrupt byte number. 
Before setting this register, set TIMINTEN MAIN-1 and SETINTCK=1 in the register 0x05. 
This matches with the received data byte number in a block synchronization state. The interrupt 
occurs at the leading part of a change in the byte number. Specify bytes 0 to 35 using the 6 bits 
INTBCKS to INTBCK8. 
5.4.3 Interrupt packet number specification (main channel) 
Table 5.4.3.1 Interrupt timing MAIN (packet number 1/2) 
Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
R FRCK7 | FRCK6 | FRCK5 | FRCK4 | FRCK3 | FRCK2 | FRCK1 FRCKO 
охір W INT INT INT INT INT INT INT INT 
(Note 1) FRCK7 | FRCK6 | FRCK5 | FRCK4 | FRCK3 | FRCK2 | FRCK1 FRCKO 
Initial value 0 0 0 0 0 0 0 0 
Note 1: The setting SETINTCK=1 should have been made in the register 0x05. 


5-23 


MSM9563 User's Manual 
Chapter 5 CONTROL REGISTERS 


Table 5.4.3.2 Interrupt timing MAIN (packet number 2/2) 






































Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
R ACTMCO | ACTMC2 | ACTMC1 | ACTMCO — — — FRCK8 
_SUB 
Ox1E W — — — — = = INT INT 
(Note 1) ALLFRCKTIM| FRCK8 
Initial value 0 0 0 0 = — 0 0 
Note 1: The setting SETINTCK-1 should have been made in the register 0x05. 
Read 





FRCK8 (MSB) to FRCKO (LSB) indicate the packet number of the packet being received. 


Write 


This is the register for specifying the main channel interrupt packet number. 
Timing interrupts occur at all packets when the setting ALLFRCKTIM=1 is made. 
Before setting this register, set TIMINTEN MAIN-0 and SETINTCK=1 in the register 0x05. 
This matches with the packet number of received data in a frame synchronization state. 















































544 Interrupt byte number specification (subchannel) 
Table 5.4.4.1 Interrupt timing SUB (byte number 1/2) 
Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
R PRE BCK7PRE ВСКвРАЕ ВСКЭРАЕ ВСКАРВЕ BCK3PRE BCK2PRE BCK1PRE BCKO 
(Note 1) _SUB _SUB _SUB _SUB _SUB _SUB _SUB _SUB 
R BCK7 BCK6 BCK5 BCK4 BCK3 BCK2 BCK1 BCKO 
0x06 (Note 2) _SUB _SUB _SUB _SUB _SUB _SUB _SUB _SUB 
W INTBCK7 | INTBCK6 | INTBCK5 | INTBCK4 | INTBCK3 — — — 
(Note 3) _SUB _SUB _SUB _SUB _SUB 
Initial value 0 0 0 0 0 0 0 0 
Note 1: The setting RDBSCK_SUB=0 (R_05[DB3]=0) should have been made in the register 
0x05. 
Note 2: The setting RDBSCK_SUB=1 (R_05[DB3]-1) should have been made in the register 
0x05. 
Note 3: The setting SETINTCK_SUB (R_05[DB4]=0, R_05[DB5]=1) should have been made in 


the register 0x05. 


MSM9563 User's Manual 
Chapter 5 CONTROL REGISTERS 


Table 5.4.4.2 Interrupt timing SUB (byte number 2/2) 















































Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
R m m — = — — — РВЕ ВСК8 
(Note 1) _SUB 
R = = = = — - — BCK8 
0x07 (Note 2) _SUB 
W == == == = = = = INTBCK8 
(Note 3) _SUB 
Initial value — = э — = н — 0 
Note 1: The setting RDBSCK_SUB=0 (В 05[DB3]-0) should have been made in the register 
0x05. 
Note 2: The setting RDBSCK SUB-1 (R_05[DB3]=1) should have been made in the register 
0x05. 
Note 3: The setting SETINTCK SUB (R_05[DB4]=0, R_05[DB5]=1) should have been made іп 


the register Ox05. 


Read (RDBSCK=1) 





BCK8 SUB (MSB) to ВСКО SUB (LSB) indicate the bit numbers of the packet being received. The 
upper 5 bits indicate the byte number. 





Read (RDBSCK=0) 
PRE BCK8 SUB (MSB) to PRE BCKO SUB (LSB) indicate the bit numbers of the packet 


immediately before the subchannel enters block synchronization. 


Write (SETINTCK SUB) 





This is the register for specifying the subchannel interrupt byte number. 
Before setting this register, make the setting of SETINTCK SUB in the register 0x05. 
This matches with the byte number of received data in a block synchronization state. The interrupt 
occurs at the leading part of a change in the byte number. 

Specify bytes 0 to 35 using the 6 bits INTBCKS to INTBCK8. 















































5.4.5  Interrupt packet number setting (subchannel) 
Table 5.4.5 Interrupt timing setting SUB (packet number) 

Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 

R FRCK7 | FRCK6 | FRCK5 | FRCK4 | FRCK3 | FRCK2 | FRCK1 FRCKO 

_SUB _SUB _SUB _SUB _SUB _SUB _SUB _SUB 

W FRCK7 | FRCK6 | FRCK5 | FRCK4 | FRCK3 | FRCK2 | FRCK1 FRCKO 

0x08 (Note 1) _SUB _SUB _SUB _SUB _SUB _SUB _SUB _SUB 
W INT FRCK7IINT FRCK6INT FRCKSINT РВСКАІМТ FRCK3INT FRCK2INT FRCK1INT FRCKO 

(Note 2) _SUB _SUB _SUB _SUB _SUB _SUB _SUB _SUB 

Initial value 0 0 0 0 0 0 0 0 

Note 1: The setting SETTIMCK SUB (R_05[DB4]=1, В 05[DB5]-0) should have been made іп 


the register 0x05. 


Note 2: 


the register 0x05. 


5-25 


The setting SETINTCK SUB (В 05[DB4]-0, В 05[DB5]-1) should have been made in 


MSM9563 User's Manual 
Chapter 5 CONTROL REGISTERS 


Read 
FRCK8 SUB (MSB) to FRCKO SUB (LSB) indicate the packet number of the packet being 
received. (FRCK8 SUB is allocated to DBO of the register 0x09.) 





Write (FRCK8 SUB to FRCKO SUB) 





This is the register for specifying the initial value of the packet number in the subchannel packet 
counter. 

Since the subchannel does not have a built-in frame synchronization circuit, it is necessary for the 
user to set the packet number. To obtain the packet number, achieve frame synchronization 
temporarily with the main channel, and write that packet number. (FRCK8_SUB is allocated to DBO 
of the register 0x09.) 


Write (INTFRCKO SUB to INTFRCK8 SUB) 

This is the register for specifying the interrupt packet number of the subchannel. 

Timing interrupts occur at all packets if the setting INTALLFRCK SUB-1 (register 0x09) is made. 
Carry out the setting of SETINTCK SUB in the register 0x09 before setting this register. 
(INTFRCK8 SUB is allocated to DBO of the register 0x09.) 























5.4.6 Interrupt frame number setting (subchannel) 
Table 5.4.6 Interrupt timing setting SUB (frame interval) 
Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
R = = = FNCK3 | FNCK2 | FNCK1 | FNCKO | FNCK8 
_SUB _SUB _SUB _SUB _SUB 
W — = = FNCK3 | FNCK2 | FNCK1 | FNCKO | FNCK8 
0x09 (Note 1) _SUB _SUB _SUB _SUB _SUB 
W — — . INTALLFRCKINT FNCK3INT FNCK2INT FNCK1|INT FNCKOINT FNCK8 
(Note 2) _SUB _SUB _SUB _SUB _SUB _SUB 
W = — — МАХ FNCK3IMAX FNCK2MAX FNCK1MAX МСКО — 
(Note 3) _SUB _SUB _SUB _SUB 
Initial value m re: 0 0 0 0 0 0 
































Note 1: The setting SETTIMCK SUB (В 05[DB4]-1, R_05[DB5]=0) should have been made in 
the register 0x05. 

Note 2: The setting SETINTCK SUB (В 05[DB4]-0, R_05[DB5]=1) should have been made іп 
the register 0x05. 

Note 3: The setting SETMAX_SUB (В 05[DB4]-1, В 05[DB5]-0) should have been made in the 
register 0x05. 





Read (FNCKO to FNCK3) 
FNCK3 (MSB) to FNCKO (LSB) indicate the frame number being counted. 


Write (FRCKO_SUB to FRCK3_SUB) 

This is the register for specifying the initial value of the frame number in the 4-bit frame number 
counter of the subchannel. 

The 4-bit frame number counter is one for generating subchannel timing interrupts at intervals of 
0 to 15 frames. 

The frame interval is specified by MAXFNCKO_SUB to MAXFNCK3_SUB. 





MSM9563 User's Manual 
Chapter 5 CONTROL REGISTERS 


Write (ІЧТЕМСКО SUB to ІМТЕМСКЗ SUB) 





This is the register for specifying the subchannel interrupt frame number. The range of setting is 
Oto 15. Carry out the settings of TIMINTEN. SUB and SETINTCK ofthe register 0x05 before setting 
this register. 


Write (MAXFNCKO SUB to MAXFNCKS3 SUB) 

This is the register for setting the maximum value of the frame number counter. The range of 
setting is O to 15. 

When the frame number counter reaches the set value, it is reset to "0" and continues counting. 











5.4.7 Clock timing adjustment (subchannel) 
Table 5.4.7 Subchannel BCK adjustment 
Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
W — — — — BCKINC B2 B1 BO 
0x0A _SUB 
Initial value = = — = 0 0 0 0 
































The subchannel packet interval is adjusted in units of a bit. 

When intermittent reception is being made at intervals of several frames, this function enables the 
accurate setting of the position of the packet to be received next. The range of adjustment at a 
time is +7 bits. Carry out this adjustment at the most once per packet when no reception is being 
made. The number of bits of adjustment required is the difference between "16" and the value 
of the registers 0x06 to 0x07 when a subchannel packet is received. 


(1) 083: BCKINC SUB 


1: Added the number of correction bits set in DBO to DB2. 
0: Eliminated the number of correction bits set in DBO to DB2. 


(2)  DBOto DB2: BO to B2 


These specify the range of adjustment (in number of bits). The maximum value is 7 bits. 





























DB2 DB1 DBO Correction bit 
0 0 0 No correction 
0 0 1 1 bit 
0 1 0 2 bits 
0 1 1 3 bits 
1 0 0 4 bits 
1 0 1 5 bits 
1 1 0 6 bits 
1 1 1 7 bits 




















5-27 


MSM9563 User's Manual 
Chapter 5 CONTROL REGISTERS 
5.5 CLOCK REGENERATION REGISTERS 


5.5.1 Fixed phase adjustment 


Table 5.5.1 Fixed phase adjustment 








Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
W — B B B4 B B2 B1 B 
0x0B _ 6 5 3 0 
Initial value — 0 0 0 0 0 0 0 
































The phase of the regenerated data clock is adjusted. Use with the initial value left unchanged. 


5.5.2 Integration constant before synchronization 


Table 5.5.2 Integration constant before synchronization 








Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
W — — — — B3 B2 B1 BO 
0x0C — 
Initial value — — — — 0 0 1 0 
































This register specifies the number of times of extracting the timing necessary for carrying out 


phase control before block synchronization. 
Specify "6" (0x06) as a typical setting value. 


5.5.3 Integration constant after synchronization 


Table 5.5.3 Integration constant after synchronization 








Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
W — — B B4 B B2 B1 B 
0x0D = 2 E : 
Initial value = — 0 1 1 0 0 0 
































This register specifies the number of times of extracting the timing necessary for carrying out 


phase control after block synchronization. 
Specify "16" (0x10) as a typical setting value. 


MSM9563 User's Manual 
Chapter 5 CONTROL REGISTERS 


5.5.4 Phase correction step 


Table 5.5.4 Phase correction step 











Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
W — B B B4 — B2 B1 B 
OxOE = 5 5 U 
Initial value — 0 0 1 — 0 0 1 
































This register is used for setting the phase correction step width of the digital PLL for data clock 
regeneration. 

DBO to DB2: The phase correction step before block synchronization. 

DB4 to DB6: The phase correction step after block synchronization. 





























DB2 (DB6) | DB1 (DB5) | DBO (DB4) Phase correction step width 
0 0 0 Prohibited 
0 0 1 250nSec 
0 1 0 500nSec 
0 1 1 750nSec 
1 0 0 1000nSec 
1 0 1 1250nSec 
1 1 0 1500nSec 
1 1 1 1750nSec 

















Set "1000ns" (0x33) as a typical setting value. 


5-29 


MSM9563 User's Manual 


Chapter 5 CONTROL REGISTERS 


5.6 BLOCK SYNCHRONIZATION REGISTERS 


5.6.1 Allowable number of BIC errors 


Table 5.6.1 Allowable number of BIC errors 








Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
W BICGATE | BICGATE — — B3 B2 B1 BO 
0x10 SEL1 SUBISELO SUB 
Initial value 0 1 — — 0 1 1 0 
































This is a specification related to the synchronization and clock regeneration processing of the 
MSM9563, and consists of the specification of the allowable number of error bits in the block 
identification code (BIC). 


(1) DB1toDB0: Allowable number of BIC errors before block synchronization (common to main 
channel and subchannels) 





























Set value Allowable number of BIC errors 
DB1 | DBO before block synchronization 
0 0 0 
0 1 1 
1 0 2 
1 1 3 








(2 DB3to DB2: Allowable number of BIC errors after block synchronization (common to main 
channel and subchannels) 





























Set value Allowable number of BIC errors 
DB3 | DB2 after block synchronization 

0 0 0 

0 1 1 

1 0 2 

1 1 3 








(3 DB7 to DB6: BICGATESEL1 SUB to BICGATE SELO SUB 


The segments given in the following table are added to the BIC detection segments in addition to 


the leading two bytes of the packet when used in the subchannel mode. 





























Set value . р 
BIC Detection gate width 
DB7 | DB6 
0 0 — 
0 1 +1 Byte 
1 0 +1.5 Byte 
1 1 +2 Byte 








5-30 


5.6.2 Number of block synchronization backward protection steps 


MSM9563 User's Manual 
Chapter 5 CONTROL REGISTERS 


Table 5.6.2 Number of block synchronization backward protection steps 











Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
W — — B1 SUB | ВО SUB — — B1 B0 
0x11 " 
Initial value — — 0 0 — — 0 1 
































This register is used for setting the number of successive detections of the block identification 
code (BIC) before considering that a block has been synchronized. 


Number of main channel block synchronization backward protection steps 























Set value Number of block synchronization Number of successive 
DB1 | DBO backward protection steps detections of BIC 
0 0 1 1 
0 1 2 2 
1 0 3 3 
1 1 4 4 








Number of subchannel block synchronization backward protection steps 



































Set value | Number of block synchronization Number of successive 
DB5 | DB4 backward protection steps detections of BIC 

0 0 1 1 

0 1 2 2 

1 0 3 3 

1 1 4 4 











5-31 


MSM9563 User's Manual 


Chapter 5 CONTROL REGISTERS 


5.6.3 Number of block synchronization forward protection steps 


Table 5.6.3 Number of block synchronization forward protection steps 






































Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
(x12 R/W ВЗ. SUB | B2 SUB | Ві SUB | ВО SUB B3 B2 B1 BO 
Initial value 1 0 0 0 1 0 0 0 
Write 


This register is used for setting the number of successive detection failures of the block 
identification code (BIC) before considering that the block has been synchronized. 

DBO to DB3: Setting of the main channel block synchronization forward protection steps 

DB4 to DB7: Setting of the subchannel block synchronization forward protection steps 



































Number of block synchronization 
рвз (DB7) | DB2 (086) | ові (DB5) | DBO (084) forward protection steps 
0 0 0 0 0 (Prohibited) 
0 0 0 1 1 
ў y 1 ў { 
1 1 1 1 15 
Веаа 


When BICs cannot be detected successively іп a block synchronization state, the number of 
detection failures is decremented from the number of block synchronization forward protection 
steps, and when the value of this register changes from 1 to O, the block is considered to have been 
out of synchronization. 

















Remaining number of Е 
DES ei n DBA block synchronization uu Out of synchronization 
(ОБО) ) forward protection steps Synchronization 
detection ..... 

0 0 0 0 0 | 

a з. 1 | When BIC 

ў } ў | | -> | cannot be detected 

1 1 1 1 15 

















Loaded during synchronization 


5-32 


MSM9563 User's Manual 
Chapter 5 CONTROL REGISTERS 


5.6.4 Block synchronization monitor 


Table 5.6.4 Block synchronization monitor 











Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
R — — — BSYN B — — — BSYN 
0x13 _ SYNC SU SYNC 
Initial value — = — 0 — — — 0 
































DBO: Main channel block synchronization state 
0: Block out-of-synchronization 
1: Block synchronized 

DB4: Subchannel block synchronization state 
0: Block out-of-synchronization 
1: Block synchronized 


5.6.5  Setting/clearing block synchronization 


Table 5.6.5 Setting/clearing block synchronization 








Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
W — — B1 ВІВ В — — B1 B 
0x14 _ _SU 0_SU 0 
Initial value — — 0 0 — — 0 0 
































Setting/clearing main channel block synchronization 





DB1 | DBO | Setting or clearing synchronization 





1 0 Clearing synchronization 
0 1 Setting synchronization 




















Setting/clearing subchannel block synchronization 





DB5 | DB4 | Setting or clearing synchronization 





1 0 Clearing synchronization 
0 1 Setting synchronization 




















5-33 


MSM9563 User's Manual 
Chapter 5 CONTROL REGISTERS 


5.7 FRAME SYNCHRONIZATION REGISTERS 


5.7.1 Number of frame synchronization backward protection steps 


Table 5.7.1 Number of frame synchronization backward protection steps 








Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
W — — — — — — B1 BO 
0x18 T 
Initial value — — — = — — 0 1 
































This register is used for setting the number of successive detections of synchronization points 


required before considering that the frame has been synchronized. 























Number of frame synchronization 
DB1 | DBO backward protection steps 
0 0 1 
0 1 2 
1 0 3 
1 1 4 











5.7.2 Number of frame synchronization forward protection steps 


Table 5.7.2 Number of frame synchronization forward protection steps 






































Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
R — — — — B B2 B1 B 
0x19 = ды 5 0 
Initial value — — — — 0 1 0 0 
Write 


This register is used for setting the number of successive detection failures of synchronization 
points before considering that the frame has been out-of-synchronized. 




















Number of frame synchronization 
DB3 | DB2 | DB1 | DBO forward protection steps 
0 0 0 0 0 (Prohibited) 
0 0 0 1 1 
ў ў ў ў ў 
1 1 1 1 15 




















5-34 


MSM9563 User's Manual 
Chapter 5 CONTROL REGISTERS 


Read 

When synchronization points cannot be detected successively in a frame synchronization state, 
the number of detection failures is decremented from the set number of frame synchronization 
forward protection steps, and when the value of this register changes from 1 to 0, the frame is 
considered to have been out-of-synchronization. 
































Remaining number of IN 
DB3 | DB2 | DB1 | DBO | frame synchronization - Out of synchronization 
forward protection steps PUE O 
0 0 0 0 0 etection ....- 
| When frame 

ы В 0 1 | ----> Synchronization 

{ y 4 y ў point cannot be detected 

1 1 1 1 15 Loaded during synchronization detection 


5.7.3 Frame synchronization monitor 


Table 5.7.3 Frame synchronization monitor 








Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
R — — — — — — — FSYN 
Ox1A — SING 
Initial value — — — — — — — 0 
































DBO: Frame synchronization monitor 
0: Frame out-of-synchronization 
1: Frame synchronized 


5.7.4 Setting frame synchronization 


Table 5.7.4 Setting frame synchronization 











Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
W x x x x x x x x 
0x1B — 
Initial value x x x x x x x x 
































5.7.5 Clearing frame synchronization 


Table 5.7.5 Clearing frame synchronization 











Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
W x x x x x x x x 
0x1C A 
Initial value x x x x x x x x 
































5-35 


MSM9563 User's Manual 
Chapter 5 CONTROL REGISTERS 








































































































5.8 ERROR CORRECTION REGISTERS 
The first horizontal error correction, vertical error correction, and the second horizontal error 
correction have been automated. 
The results of correction and CRC can be read together with the receive data from the receive port 
after the first horizontal error correction and the receive port after the second horizontal error 
correction. 
In addition, the number of corrections and the threshold value have been set optimally. 
Therefore, normally, there is no need to set the registers 0x20, 0x21, 0x22, 0x23, 0x24, and 0x25. 
5.8.1 Clearing address 
Table 5.8.1 Clearing address 
Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
W = — — — — — B1 BO 
0x20 — 
Initial value — — — — — — 0 0 
B1 BO 
Address Clear 0 1 
ЕВСО СНО (for testing) 1 0 
5.8.2 Error correction data port 
Table 5.8.2 Error correction data port 
Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
R B7 B6 B5 B4 B3 B2 B1 BO 
0x21 W B7 B6 B5 B4 B3 B2 B1 BO 
Initial value — — — — — — — — 
5.8.3 Error correction start 
Table 5.8.3 Error correction start 
Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
Second i First 
R m m m m m horizontal ПА horizontal 
correction correction 
state state state 
0x22 W == — — = —  _|Startsecond| Start | Start first 
horizontal | vertical | horizontal 
correction |correction| correction 
Initial value — — — — — — — — 
































5-36 


5.8.4 Number of corrections and error correction results 


MSM9563 User's Manual 
Chapter 5 CONTROL REGISTERS 


Table 5.8.4 Number of corrections and error correction results 


































































































Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
R Result of Result of = = = = Second First 
NW horizontal | horizontal 
correction | correction CRC гези СРС result 
0x23 W Number of | Number of | Number of | Number of | Number of | Numberof | MOD. | MOD. 
| f | e ) ) 
ME MES BL corri acions -B2 correctors -Bi conetons 80 A M A 
Initial value 1 1 1 1 1 0 1 1 
5.8.5 Results of vertical error correction 
Table 5.8.5 Results of vertical error correction 
Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
0x24 R CRCOUT7 | CRCOUTE6 | CRCOUTS | CRCOUT4 | CRCOUTS8 | CRCOUT2 | CRCOUT1 | CRCOUTO 
Initial value 0 0 0 0 0 0 0 0 
5.8.6 Number of corrections and threshold value 
Table 5.8.6 Number of corrections and threshold value 
Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
W Number of Шш of Number of | Threshold | Threshold | Threshold | Threshold | Threshold 
0x25 horizontal | horizontal | horizontal | Value | value | value | value | value 
corrections _B2\corrections _B1|corrections_BO| ТНА TH3 TH2 TH1 THO 
Initial value 1 1 1 0 1 1 1 0 














5-37 


MSM9563 User's Manual 
Chapter 5 CONTROL REGISTERS 


5.9 LAYER 4 CRC REGISTERS 
5.9.1 Layer 4 CRC registers 


Table 5.9.1 Layer 4 CRC register 












































Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
R L4CRC — — — — — — — 
T 
0x28 ЗВ 
W MOD2 MOD1 MODO — — — MEMTST | CLRCRC 
Initial value 1 1 0 — 0 0 0 0 
Write 


(1) DBO: CLRCRC 
Write а "1" before executing layer 4 CRC 
However, (111X0001) is valid only when DB5=DB6=DB7=1. 


(2) DB1: MEMTEST 
The use of any value other than "0" is prohibited. 


(3) DB5 to DB7: Setting of the test mode 
Use one of the modes given in the following table. 












































Set mode DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
CLRCRC 1 1 1 — 0 0 0 1 
Other than CLRCRC 0 1 0 — 

0 0 1 — — — 0 — 
0 0 0 — 
Read 


(1) DB7: LACRCOUT (Display of layer 4 CRC result) 
1: There is an error in the layer 4 CRC result. 
0: The layer 4 CRC result is normal. 


5.9.2 Layer 4 CRC data port 


Table 5.9.2 Layer 4 CRC data port 














Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
R B7 B6 B5 B4 B3 B2 B1 BO 
0x29 W B7 B6 B5 B4 B3 B2 B1 B0 
Initial value x x x x x x x x 
































Write the data group for which CRC processing is to be made in units of a byte at a cycle period 
of 620ns or more. 


5-38 


MSM9563 User's Manual 
Chapter 5 CONTROL REGISTERS 


5.9.3 Layer 4 CRC result 


Table 5.9.3 Layer 4 CRC result 








Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
R — — — — — — — L4CRC 
0x2A result 
Initial value — = m — — — — 0 
































(1) 


DBO: L4CRC result 
0: Normal 


1: Error 


Read out the layer 4 CRC result when a time of 1.2us or more has elapsed after writing the 
last data of the data group. 


5.9.4 Layer 4 CRC register 


This is the register for writing the initial value directly in the CRC computation registers and for 
reading out the intermediate result. 
It is possible to execute the layer 4 CRC processing of a short data group by interrupting the layer 
4 CRC processing of a long data group. 


Table 5.9.4.1 Layer 4 CRC register upper 8 bits 


















































Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
R/W B7 B6 B5 B4 B3 B2 B1 BO 
0x2B m 
Initial value 0 0 0 0 0 0 0 0 
Table 5.9.4.2 Layer 4 CRC register lower 8 bits 
Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
R/W B7 B6 B5 B4 B3 B2 B1 BO 
0x2C — 
Initial value 0 0 0 0 0 0 0 0 
































5-39 


MSM9563 User's Manual 
Chapter 5 CONTROL REGISTERS 


5.10 ANALOG TEST REGISTER 


Table 5.10.1 Analog test 









































Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
W — DETO M2 M1 MO SGAIN1 | SGAINO | DETC 
0x30 DTST 
Initial value — 0 0 0 0 0 0 0 
(1) DBO: DETC 


(3) 


For testing purposes only. 


Use normally with DETC=0. 


DB2 to DB1: SGAIN1 to SGAINO 
These set the variable gain amplifier for the analog signal input (composite signal). 
Set so that peak value of the analog input signal (composite signal)xgain=0.5 to 0.9Vp.p. 



























































DB2 DB1 | 
Сат 
(SGAIN1) (SGAINO) 
0 0 x 1 
0 1 x1.5 
1 0 x2 
1 1 x3 
DB3 to DB5: M2 to MO 
This register controls the monitor terminal (MON pin) for the analog section output 
waveform. 
DB5 DB4 DB3 mE 
MON Pin (pin1) 
(M2) (M1) (MO) 
0 0 0 Internal monitor pin power-off, Hz output 
0 0 1 LPF output of input stage 
0 1 0 BPF output 2 
0 1 1 BPF output 4 
1 0 0 BPF output 6 
1 0 1 BPF output 8 
1 1 0 Internal amplifier output 
1 1 1 Equivalent waveform output 
(for observing the eye pattern) 




















5-40 


MSM9563 User's Manual 
Chapter 5 CONTROL REGISTERS 


DB6: DESTODTST 
For testing purpose only. 
Normally use with the setting DB6=0. 

















DB6 DBO A 
DET (data identification circuit) input control 
(DETODTST) (DETC) 
0 0 AIN pin input enable (FM multiplex broadcast reception) 
0 1 ADETIN pin input enable (analog input) 
1 0 
і i ADETIN pin input enable (digital input) 














511 POWER DOWN REGISTER 


Table 5.11 Power down 








Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
0x31 W — XCK2 XCK1 XCKO — B2 B1 BO 
Initial value — 0 0 0 — 0 0 0 
































DB4 to DB6: XCKO to ХСК2 (setting the divided frequency of external clock) 
Set the divided frequency of the clock that is output to the XOUT pin, as follows (when 
XOUTC=0) 
































DB6 | DB5 | DB4 | XOUT Pin output clock frequency 
0 0 0 8.192 MHz 
0 0 1 4.096 MHz 
0 1 0 2.048 MHz 
0 1 1 1.024 MHz 
1 0 0 0.512 MHz 
1 0 1 0.256 MHz 
1 1 0 0.128 MHz 
1 1 1 0.064 MHz 

















DB2: External clock input 
This controls the operation of the crystal oscillator circuit as follows when the XOUTC pin 
is "1". Also, in this case, the XOUT output pin is set to the "L" level. 

0: The operation of the crystal oscillator circuit is stopped. 

1: The crystal oscillator circuit is acrivated. 


When the XOUTC pin is "0", the crystal oscillator circuit will be operating continuously and 
the XOUT pin also will be outputting the clock signal continuously. 


5-41 


MSM9563 User's Manual 
Chapter 5 CONTROL REGISTERS 


(3  DB1: Digital section power down 
0: The power is down and the internal clock stops at the "H" level. 
1: The power is turned on and the clock for operating the digital section starts from the 
"H" level. 


(4 DBO: Analog section power down 
0: Power down (operation stops) 


1: Power on (several milliseconds will be required for the circuit operation to become 
stable after the power is turned on.) 


5.12 TEST CONTROL REGISTERS 
5.12.1 Test control 0 


Table 5.12.1 Test control 0 








Address R/W | DB7 | DB6 | 085 | рва | рвз | DB2 | рві | ово _ 
W B7 B B — — = = = 
0x32 = б 5 
Initial value 0 0 0 — — — = = 
































This is the register for controlling the selection of ће test output pins (MOUTO to МОШТА), and is 
used for testing only. 






































Set value 
Pin Extention port LSI internal signal monitor 

name 0xC0, ОХАО, 0x00 0x20 0x40 | 0x60 | 0x80 OxEO 

(TSTO) (TSTT1) (TSTBO)| (TSTB1) (TSTC) 
MOUTO | DBO of register 0x0F | BPF-LimOut TS11 FRCKO FSYNC (Note 1) 
MOUT1 | DB1 of register OXOF | Delay detector Out | TS21 FRCK1 BSYNC (Note 2) 
MOUT2 | DB2 of register OxOF | LPF-LimOut 7510 |FRCK2 | RAMOUT | BICO (Note 3) 
MOUT3 | DB3 of register OxOF | SCF clock GATE |FRCK3 |BICDET2 |BIC1 (Note 3) 
MOUT4 | DB4 of register OXOF | Fixed to "L" PHCK1 | BCK BICDET — | BICDET1 (Note 3) 




















Note 1: FSYNC 
1: Frame synchronized 
0: Frame out-of-synchronization 


Note 2: BSYNC 


1: Block synchronized 
0: Block out-of-synchronization 


5-42 


MSM9563 User's Manual 
Chapter 5 CONTROL REGISTERS 


Note 3: BIC Detection 




















BICDET1| ВІСІ BICO BIC NO. 
1 0 0 1 
1 0 1 2 
1 1 0 3 
1 1 1 4 
0 — — Not detected 




















5.12.2 Test control 1 


Table 5.12.2 Test Control 1 











Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
W — e nm Serial output |PN Decoding Differential! Clock Serial 
output Output | controli | contro) | decoding | output | output 
0x33 control1 | control 0 control | control | control 0 
Initial value — 0 0 0 0 1 0 0 
































This register controls serial receive data and the switching of the test output pins (MOUT5 and 
MOUT6). This is used for testing only. 


(1) DBO, DB4: Serial receive data output 




















DB4 DBO MOUTS pin output 
0 0 Fixed to "L" 
0 1 Serial receive data after descrambling 
1 0 
1 1 Serial receive data before descrambling 











(2 DB1: 16kHz regeneration data clock 
0: The MOUTS pin is fixed to "1". 
1: A 16kHz regeneration data clock is output to the MOUTS pin. 


(3 DB2: Differential decoding control 
0: Performs differential decoding to input data. 
1: Does not perform differential decoding. 
(This is used for receiving FM multiplex broadcast) 


(4 DB3: Descramber control 
0: Descrambles data other than BIC. 
(This is used for receiving FM multiplex broadcast.) 
1: Does not descramble other than BIC. 


5-43 


MSM9563 User's Manual 
Chapter 5 CONTROL REGISTERS 


(5) | DB5, DB6: Delay detector output control 

















DB6 DB5 Delay detector control 
0 0 ENOR (FM multiplex broadcast reception) 
0 1 Through (data before 1T) 
1 0 
EOR 
1 1 














5.13 EXTENSION PORT REGISTER 


It is possible to output the write data (DBO to ОВА) of this register to the monitor output terminal 
by setting ОХСО, and ОхАО, or 0x00 in the register 0x32. 


Table 5.13 Extension port register 








Address R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DBO 
W — — — DB4 DB3 DB2 DB1 DBO 
OxOF — 
Initial value — — — 0 0 0 0 0 
































5-44 


Chapter 6 


EXTERNAL CONNECTION 
EXAMPLE 





MSM9563 User's Manual 
Chapter 6 EXTERNAL CONNECTION EXAMPLE 


6. EXTERNAL CONNECTION EXAMPLE 

















































































































CPU 
де interface 

1 CLR | 
— MON А5 | 
Типег Section 2 | ADETIN а | 
| A2 
| 330 pF | 
(+10%) | | 
[> IH ain | 
| 5 XOUT | 
SG AU ! 
| 2.2 uF 1+ CS | 
| oe E XTAL2 15 pF | 
| 8.192 MHz crystal i 
(Note 3) 25819, а | 
XTAL1 hse Ў | 
(Note 2)_ + 3 | App мор: 28» (Note 2) | 
2 + AGND DGND l 
14 DB7 a | 
ч MOUT6 DB6 24 і 
р MOUTS DB5 > | 
р MOUTA 084 > | 
0 MOUT3 DB3 2 
АІ mout2 DB2 | | 
— | mourt DBI [20 | 
——*— MOUTO DBO 
RD 18 І 
RD | 
WR [16 | 
мт |5 

DVpp = " +3 V power supply input 


AVpp 3 ————— Е 
(Note 2) ii 
DGND ~ А 


AGND = 








(Note 1) Use a tantalum capacitor. 
(Note 2) The AVpp and DVpp should have different paths, respectively. 
(Note 3) The AGND and tuner ground should use the same ground. 


MSM9563 User's Manual 
Chapter 6 EXTERNAL CONNECTION EXAMPLE 


6-2 


Chapter 7 


APPLICATION CIRCUIT 





MSM9563 User's Manual 
Chapter 7 APPLICATION CIRCUIT 


7. APPLICATION CIRCUIT 


Antena 





FM 
tuner 


| 









































8 bits 
E NI | J о 
аїа ВЕ ulation (ROM) 
MSM9563 
Font LCD control 
SRAM ROM driver 























LCD display 


(16 kanji characters x 2 lines) 





7-1 


MSM9563 User's Manual 
Chapter 7 APPLICATION CIRCUIT 


7-2 


APPENDIX 





L-xipueddy 





































































































































































































































































































MSM9552/9553 (reference) MSM9562/9563 
Register] . Initial |Recommended| К Page | Initial |Recommended| Register] 
Category Register name R/W | Category Register name R/W 
address value value *1 No. value value *2 address 
0x00 Interrupt | Interrupt cause 0-000000 — R/W | Interrupt | Interrupt register 5-5 | 0000-000 —= R/W | 0x00 
0x01 Interrupt mask --000000 — W Interrupt mask 5-6 | 0000-00- — W | 0x01 
0x02 [Receive data, Receive block condition 00000000 — В |Весеме data | Receive port selection after first horizontal error correction 5-7 | ------ 0 — W | 0x02 
0x03 Receive data and first horizontal error correction data port Undefined — R Receive port after first horizontal error correction 5-8 Undefined = R/W | 0x03 
0x04 Receive RAM, data accumulation condition, and address clear | ------ 0- | 11111111 | W Operating mode) Main channel/subchannel mode setting 5-1 ---0---1 = W | 0x04 
0x05 Timing iming interrupt mode 5-22 | -0000-00 — W | 0x05 
0x06 interrupt | Interrupt timing. SUB (byte number 1/2) 5-24 |00000000 = R/W | 0x06 
0x07 BIC Monitor ----000 — R nterrupt timing _SUB (byte number 2/2) 5-25 | == 0 — R/W | 0x07 
0x08 Clock Fixed phase adjustment -0000000| 10000000 R nterrupt timing _SUB (packet number) 5-25 |00000000 = R/W | 0x08 
0x09 |regeneration | Bit gate ----0000 | 11110000 R nterrupt timing _SUB (frame interval) 5-26 | --000000 = R/W | 0x09 
0x0A Integration constant (1/4) ----0010 | 11110110 R Clock timing adjustment (subchannel) 5-27 | ----0000 = W | 0x0A 
0x0B Integration constant (2/4) ----0010 | 11110110 R Clock Fixed phase adjustment 5-28 |-0000000 — W | 0x0B 
0x0C Integration constant (3/4) --011000 | 11010000 В [regeneration | Integration constant before sysnchronization 5-28 | ----0010 | ----0110 W | 0x0C 
0x0D Integration constant (4/4) --011000| 11010000 R integration constant after synchronization 5-28 |--011000| --010000 | W | 0x0D 
ОХОЕ Phase correction step ----0101 | 11111111 В Phase correction step 5-29 |-001-001 | -011-011 W | ОХОЕ 
0x10 Block Allowable number of BIC errors ----0110 | 11111001 | W Block Allowable number of BIC errors 5-30 |01--0110| 00--1001 W | 0x10 
Ox11 |synchronizaiton| Number of block synchronization backward protection steps | ------ 01 | 11111101 | W [synchronization | Number of block synchronization backward protection steps | 5-31 | --00--01 | --01--10 М | 0х11 
0x12 Number of block synchronization forward protection steps ----1000 11111111 | W Number of clock synchronization forward protection steps 5-32 |10001000| 01001111 | R/W| 0x12 
0x13 Block synchronization monitor 0000---0 — R Block synchronization monitor 5-83 | ---0---0 — R 0x13 
0x14 Block synchronization setting/clearing 5-33 | --00--00 — W | 0x14 
0x15 Block synchronization clearing XXXXXXXX — W 0x15 
0x16 In-block bit number monitor (1/2) 00000000 = R Timing | Interrupt timing МАІМ (byte number 1/2) 5-23 [00000000 = R/W | 0x16 
0x17 In-block bit number monitor (2/2) | = 0 — R interrupt | Interrupt timing _MAIN (byte number 2/2) 5-23 | ------- 0 = RW | 0x17 
0x18 Frame Number of block synchronization backward protection steps | ------ 01 | 11111100 | W Frame Number of frame synchronization backward protection steps | 5-34 | ------ 01 | = 00 W | 0x18 
Ox19 |synchronization| Number of block synchronization forward protection steps ----0100 | 11110100 | W synchronization! Number of frame synchronization forward protection steps 5-34 | ----0100 = RW | 0x19 
ОМА Frame synchronization monitor 0000--0- m R Frame synchronization monitor 5-35 | ------- 0 = R ОМА 
Ox1B Frame synchronization setting 5-35 |Undefined — W | 0x1B 
0x1C Frame synchronization clearing XXXXXXXX — W Frame synchronization clearing 5-35 |Undefined == W | 0х1С 
0x1D In-frame block number monitor (1/2) 00000000 = R Timing | Interrupt timing МАІМ (packet number 1/2) 5-23 |00000000 = RW | 0х10 
0x1E In-frame block number monitor (2/2) — R interrupt | Interrupt timing МАІМ (packet number 2/2) 5-24 |0000--00 == RW | 0x1E 
Ox1F International frame format specification — W Operating mode| Frame format specification 5-1 | ------ 10 — W | 0x1F 











*1 Unused bits are entered as "1". 


*2 Unused bits are entered as '—'. 


(2/1) 593151999 JO 157 


XIGNAddV 


Jenue|y $.195П £9S6lA SIN 


c-xIpueddy 



















































































































































































MSM9552/9553 (reference) MSM9562/9563 
Register] . Initial |Recommended И Раде | Initial |Recommended| Register| 
Category Register name R/W! Category Register name R/W 
address value value No. value value address 

0x20 Error Internal address counter clear XXXXXXXX — W Error Internal address counter clear 5-36 | ------ 00 — W | 0x20 
0x21 | correction | Data transfer port for error correction Undefined — R/W | correction | Data transfer port for error correction 5-36 | -------- — R/W | 0x21 
0x22 Start signal for error correction = | 000 = R/W Start signal for error correction 5-36 | -------- == R/W | 0x22 
0x23 CRC Result display/second horizontal error | = 0-0 = R Number of corrections and error correction result 5-37 111111011 = R/W| 0x23 
0x24 Error correction result display 00000000 — R Vertical error correction result 5-37 100000000 — R 0x24 
0x25 Majority logic threshold value ---01000 | 11101001 | W Number of vertical error corrections and threshold value 5-37 |11101110 — W | 0x25 
0x28 Layer 4 CRC | Clear layer 4 CRC registers 11000000 R/W | Layer 4 CRC | Layer 4 CRC 5-38 |110-0000 = R/W| 0x28 
0x29 Layer 4 CRC data buffer 00000000 = RW Layer 4 CRC data buffer 5-38 |Undefined = R/W | 0x29 
0x2A Layer 4 CRC result display | == 0 — R Layer 4 CRC result display 5-39 | ------- 0 — R 0x2A 
0x2B Layer 4 CRC register (1/2) 00000000 — RW Layer 4 CRC register (upper 8 bits) 5-39 |00000000 — R/W | 0x2B 
0x2C Layer 4 CRC register (2/2) 00000000 = R/W Layer 4 CRC register (lower 8 bits) 5-39 [00000000 — R/W | 0x2C 
0x2D 

Ox2E 

0x30 {Analog control} Analog section control/monitor --000000 | 11111110 | W Analog control} Analog test 5-40 | -0000000 — W | 0x30 
0x31 |Power down | Power down register -000-000 10001111 | № |Power down} Power down 5-41 | -000-000 — W | 0x31 
0x32 | Test control | Test control 0 000----- 00011111 | W | Test control | Test control O 5-42 | 000----- — W | 0x32 
0x33 Test control 1 -0000000| 10010111 | W Test control 1 5-43 |-0000100 — W | 0x33 
0x34 Receive data | Receive interrupt conditions after first horizontal error correction | 5-11 100100000 — W | 0x34 
0x35 SI (service identifier) specification 532 |11111111 = W | 0x35 
0x37 Frame synchronization condition 5-20 |-0000000 — R/W | 0x37 
0x38 Receive port after second horizontal error correction 5-12 |Undefined — R/W | 0x38 
0x39 Frame memory access mode 5-18 100000100 — W | 0x39 
Ox3B Frame memory address (1/3) 5-19 |--000000 — R/W | Ox3B 
0x3C Frame memory address (2/3) 5-19 [00000000 == R/W | 0x3C 
0x3D Frame memory address (3/3) 5-19 | ------- 0 = R/W | Ox3D 
Ox3E Operating mode} Page mode/clear main channel 5-3 1-0-00000 = W | ОХЗЕ 
OxOF [Extension port! Extension port ---00000 — W  |Extension рогі] Extension port 5-43 | ---00000 — W | OxOF 















































(с/с) SH31SI938 JO 151 


XIGNAddV 


jenueyy S.19SN E9SGINSIN 


MSM9563 


User's Manual 





First Edition: January 1999 
Second Edition: December 1999 


© 1999 Oki Electric Industry Co., Ltd. 





FEUL9563-02