Water Specialist 
1" Control Valve Series Model: WS1CS 
1.25" Control Valve Series Model: WS1.25CS 


Operation and Instruction Manual for OEM Only. 


Please Note: 'This operation and instruction manual is for the training of the 
OEM and for the OEM to use to train their customers. This document is not 
to be used as the complete system manual. 





WS1CS & WS1.25CS Manual Page 3 


Table of Contents 
Control Valve Function and Cycles of Operation .................... riasenie rennen nnns 4 
OEM General InStrüctionS........ ecciesie ences oett qve teta ee etta E etae vene Slide vae vare dde eno eve icis 8 
OEM Softener: System Setup... e ei i eie ae ten b Ra p Co e ie pelo R nae e eo xe pa indue 9 
Setting Options Tables ———————————— E 10 
OEM Filter System Setup; ai a qe i aa apa EOS Re REA FIR Eae e E e I Re SA 11 
Installer Display Settings... itio teret tee ettet ttr bn ca E eau Vea dente eR Ve NA eda 12 
[UTD DEVON UIDI 12 
IEPGDIID Cc ——————————————————" 14 
Valve HIStory DR 15 
CS Front Cover and Drive Assembly ........: eee ertet tee rci vete tuve e dee et Ve ani t ea v ied 16 
WSICS Drive Cap Asy, Pistons and Spacer Stack Assembly irisi 17 
WS1.25CS Drive Cap Asy, Pistons and Spacer Stack Asy..................ssssssessssssseeeeeeee eene nennen nenne 18 
WS and WS1.25 Identification Figute......:.5..3: c ae notae cr ode i er de pliego 19 


FOR INFORMATION COMMON TO ALL 1” & 1.25” CONTROL VALVES REFER TO THE 
WS1 AND WS1.25 DRAWINGS AND SERVICE MANUAL 


Page 4 WS1CS & WS1.25CS Manual 


Control Valve Function and Cycles of Operation 


This glass filled Noryl' (or equivalent) fully automatic control valve is designed as the primary control center to direct and regulate 
all cycles of a water softener or filter. When the WSICS or WS1.25 control valve is manufactured as a softener, the control valve 
can be ordered to perform downflow or upflow regeneration. When the WSICS or WS1.25CS control valve is set up as a filter, 

the control valve can be set to perform downflow regeneration or simply backwash. The control valve can be set to regenerate on 
demand (consumption of a predetermined amount of water) and/or as a time clock (passage of a particular number of days). The 
control valve can be set so that a softener can meet the Water Quality Association (WQA) Standard S100 or NSF/ANSI Standard 44 
efficiency rating. 


It is not recommended to change control valves from downflow to upflow brining or vice versa in the field. The valve bodies 
for downflow and upflow are unique to the regeneration type and and should not be interchanged. A mismatch of valve body 
and regeneration piston will result in hard water bypass during service. 


The control valve is compatible with a variety of regenerants and resin cleaners. The control valve is capable of routing the flow 
of water in the necessary paths to regenerate or backwash water treatment systems. The injector regulates the flow of brine or 
other regenerants. The control valve regulates the flow rates for backwashing, rinsing, and the replenishing of treated water into a 
regenerant tank, when applicable. 


The control valve uses no traditional fasteners (e.g. screws); instead clips, threaded caps and nuts and snap type latches are used. 
Caps and nuts only need to be firmly hand tightened because radial seals are used. Tools required to service the valve include one 
small blade screw driver, one large blade screw driver, pliers and a pair of hands. A plastic wrench is available which eliminates the 
need for screwdrivers and pliers. Disassembly for servicing takes much less time than comparable products currently on the market. 
Control valve installation is made easy because the distributor tube can be cut 4” above to 4” below the top of tank thread. The 
distributor tube is held in place by an o-ring seal and the control valve also has a bayonet lock feature for upper distributor baskets. 


The AC adapter power pack comes with a 15 foot power cord and is designed for use with the control valve. The AC adapter power 
pack is for dry location use only. The control valve remembers all settings for up to 8 hours if the power goes out and the battery 

is not depleted. After 8 hours, the only item that needs to be reset is the time of day; other values are permanently stored in the 
nonvolatile memory. If a power loss lasts less than 8 hours and the time flashes on and off, the time of day should be reset and the 
non rechargeable battery should be replaced. 


Table 1 shows the order of the cycles when the valve is set up as a softener. The OEM has the option of having the regenerant refill 
after the rinse cycle or have the regenerant prefill before regeneration. If the OEM chooses to have the regenerant prefill before 
regeneration, the prefill starts two hours before the regeneration time set. During the 2-hour period in which the brine is being made, 
treated (softened) water is still available. For example: regeneration time = 2:00 am, prefill option selected, downflow softener. 

Fill occurs at 12:00 a.m., start of backwash cycle occurs at 2:00 a.m. Tables 2 and 3 show the length of the cycles when different 
program codes are selected. 


Table 1 
Regeneration Cycles Softening 


WSICS & WS1.25CS WSICS & WS125CS WSICS & WS1.25CS WSICS & WS1.25CS 
Downflow Regenerant Downflow Regenerant Upflow Regenerant Upflow Regenerant 
Refill After Rinse Prefill Refill After Rinse Prefill 
I* Cycle: Backwash I* Cycle: Fill 1“Cycle: Regenerate I* Cycle: Fill 
2"! Cycle: Regenerate 2" Cycle: Service 2" Cycle: Backwash 2*4 Cycle: Service 


3" Cycle: Second 3" Cycle: Backwash 3" Cycle: Rinse 3" Cycle: Regenerate 
Backwash* 4* Cycle: Regenerate 4" Cycle: Fill/Dissolve 4* Cycle: Backwash 
4* Cycle: Rinse 5* Cycle: Second 5* Cycle: Service 5" Cycle: Rinse 
5" Cycle: Fill/Dissolve Backwash* 6™ Cycle: Service 
6" Cycle: Service 6" Cycle: Rinse 
7* Cycle: Service 





*Second Backwash is optional 





! Noryl is a trademark of General Electric. 


WS1CS & WS1.25CS Manual 



























































































































































Table 2 
Downflow Softener Program Codes for WS1CS or WS1.25CS 
Program Main Piston 1* Brine/ Slow 2:5 Fast 
Code Backwash Rinse Backwash | Rinse 
P1 Down Flow 3 40 3 3 
P2 Down Flow 3 45 3 3 
P3 Down Flow 4 45 4 3 
P4 Down Flow 4 60 4 3 
P5 Down Flow 5 60 4 4 
P6 Down Flow 5 60 5 4 
P7 Down Flow 6 45 4 3 
P8 Down Flow 6 60 5 4 
P9 Down Flow 6 60 6 5 
P10 Down Flow 7 50 5 4 
Pll Down Flow 7 60 6 6 
P12 Down Flow Y 65 7 7 
P13 Down Flow 8 45 5 4 
P14 Down Flow 8 60 6 6 
P15 Down Flow 8 60 8 8 
P16 Down Flow 8 65 8 6 
P17 Down Flow 8 65 8 7 
P18 Down Flow 8 75 8 5 
P19 Down Flow 9 50 5 5 
P20 Down Flow 9 60 5 4 
P21 Down Flow 9 65 8 5 
P22 Down Flow 10 45 4 4 
P23 Down Flow 10 60 5 4 
P24 Down Flow 10 65 8 8 
P25 Down Flow 10 65 6 5 
P26 Down Flow 10 75 7 5 
P27 Down Flow 12 45 4 4 
P28 Down Flow 12 60 6 4 
P29 Down Flow 12 60 8 8 
P30 Down Flow 12 65 6 6 
P31 Down Flow 12 65 8 8 
P32 Down Flow 12 65 12 8 
P33 Down Flow 12 75 6 6 
P34 Down Flow 14 45 5 4 
P35 Down Flow 14 60 6 5 
P36 Down Flow 14 60 8 8 
P37 Down Flow 14 65 7 6 
P38 Down Flow 14 65 8 8 
P39 Down Flow 14 65 12 8 
P40 Down Flow 14 75 8 7 
P41 Down Flow 16 60 7 5 
P42 Down Flow 16 65 8 6 
P43 Down Flow 16 65 8 8 
P44 Down Flow 16 65 12 8 
P45 Down Flow 16 75 9 7 
P50 Down Flow 6 45 3 3 
P51 Down Flow 8 60 8 4 
P52 Down Flow 8 T3 10 6 


























Page 5 


Table 4 shows the order of the cycles when the 
valve is set up as a filter. If the control valve is set 
to regenerate for a filter, the OEM has the option 
of having the regenerant refill after the rinse cycle 
or have the regenerant prefill before regeneration. 
If the OEM chooses to have the regenerant prefill 
before regeneration, the prefill starts two hours 
before the regeneration time set. During the 
2-hour period in which the regenerant is being 
made, treated water is still available. For example: 
regeneration time = 2:00 am, prefill option 
selected, downflow filter. Fill occurs at 12:00 a.m., 
start of backwash cycle occurs at 2:00 a.m. 


When the control valve is used as a non- 
regenerating filter, the OEM has the option to 
specify one backwash or two backwashes. If two 
backwashes are specified, two rinses occur. Tables 
5 and 6 show the length of the cycles when the 
valve is set up as a filter. When used as a non- 
regenerating filter, the downflow piston must be 
installed, the regenerant piston removed, injector 
plugs must be installed in both the DN and UP 
injector locations and the refill elbow must be 
replaced with a refill port plug. 


NOTE: The program codes listed on this page 
and the following page should be used only as a 
guideline. Any program code listed can be applied 
to a softener or filter application for WS1CS 
valves. 


Page 6 WS1CS & WS1.25CS Manual 









































Table 3 
Upflow Softener Program Codes for WS1CS or WS1.25CS 
Program| Main ]* Brine/Slow 2» Fast 
Code Piston | Backwash Rinse Backwash | Rinse 
P60 Upflow N/A 45 6 4 
P61 Upflow N/A 45 8 6 
P62 Upflow N/A 60 10 6 
P63 Upflow N/A 60 12 8 
P64 Upflow N/A 75 10 6 
P65 Upflow N/A 75 12 8 
Table 4 


Regeneration Cycles Filtering for WS1CS or WS1.25CS 


Downflow Downflow Regenerant Prefill No Regenerant 
Regenerant Refill After Rinse 


]* Cycle: Backwash I* Cycle: Fill ]* Cycle: Backwash 
2"! Cycle: Regenerate 24 Cycle: Service 2"! Cycle: Rinse 


3" Cycle: Second Backwash* 3" Cycle: Backwash 3" Cycle: Second Backwash* 
4" Cycle: Rinse 4" Cycle: Regenerate 4" Cycle: Second Rinse 
5"Cycle: Fill 5* Cycle: Second Backwash* 5* Cycle: Service 
6* Cycle: Service 6* Cycle: Rinse 

7* Cycle: Service 





*Second Backwash is optional in some Program Codes 


































































































Table 5 
Regenerating Filter Program Codes for WS1CS or WS1.25CS 
Program | Main Piston 1* Brine/ 25 Fast 
Code Backwash Slow Backwash | Rinse 
Rinse 
P70 Downflow 6 20 6 6 
P71 Downflow 12 10 N/A 12 
P72 Downflow 4 50 N/A 4 
P73 Downflow 10 50 N/A 6 
P74 Downflow 12 60 N/A 10 
P75 Downflow 12 75 N/A 10 
Table 6 
Non-Regenerant Filter Program Codes for WS1CS or WS1.25CS 
Program | Main Piston ]* 1“ De 225 
Code Backwash | Fast Rinse | Backwash | Fast Rinse 
P80 Downflow 8 8 N/A N/A 
P81 Downflow 12 6 N/A N/A 
P82 Downflow 14 8 N/A N/A 
P83 Downflow 14 10 N/A N/A 
P84 Downflow 16 10 N/A N/A 
P85 Downflow 18 10 N/A N/A 
P86 Downflow 20 10 N/A N/A 
P90 Downflow 8 6 10 8 
P91 Downflow 12 6 12 10 
Note: For non-regenerant filters: 1) The regenerant piston is removed; 2) injector 
plugs are installed in both the UP and DN holes under the injector cap. 





WS1CS & WS1.25CS Manual Page 7 


Table 7 
DIR/Time Clock Options 


" 
DIR me "Reserve Capacity Softener Backwash Gallon 
Clock Regenerant 
Only Loses em 


EM — Automatically calculated aa | Auto | 


If desired enter a value less Any 
than estimated poem E Number 


Farm [Automatically calculated — | — — Any Number 
If desired enter a value less Any Number Any 
than estimated — number 


m oe [None — | m wm umet uu NUN 





The control valve with a water meter can be set for Demand Initiated Regeneration (DIR) only, Time Clock operation only or DIR and 
Time Clock which ever comes first, depending upon what settings are selected for Day Override and Gallon Capacity? See Table 7. 


If a control valve does not contain a meter, the valve can only act as a time clock, and day override should be set to any number and gallon 
capacity should be set to off. 


For DIR Softeners, there are two options for setting the Gallons Capacity. The Gallons Capacity is automatically calculated if set to AUTO. 
Reserve Capacity is automatically estimated based on water usage if AUTO is used. The other option is to set the Gallons Capacity to a 
specific number. If a specific number is set, reserve capacity is zero, unless the value is manually set (i.e. the 

manufacturer intentionally sets the gallon capacity number below the calculated capacity of the system). 


The control valve can also be set to regenerate immediately or at the next regeneration time by changing the Regeneration Time Option. 
There are three choices for settings: 


1l. "NORMAL" means regeneration will occur at the preset regeneration time. 
2. “on 0” means regeneration will occur when the gallons capacity reaches zero. 
3. “NORMAL” and “on 0” means the regeneration will occur at the preset regeneration time unless the gallons capacity reaches zero. If 


the gallons capacity reaches zero the regeneration will begin 10 minutes after no water usage. 


The user can initiate manual regeneration. The user has the option to request the manual regeneration at the delayed regeneration time or to 

have the regeneration occur immediately: 

1. Pressing and releasing the REGEN button. “Regen Today" will flash on the display and the regeneration will occur at the delayed 
regeneration time. The user can cancel the request by pressing and releasing the REGEN button. This method of manually initiating 
regeneration is not allowed when the system is set to “on 0,” i.e. immediately regenerate when the gallon capacity reaches zero. 

2. Pressing and holding the REGEN button for approximately 3 seconds will immediately start the regeneration. The user cannot cancel 
this request, except by resetting the control by pressing NEXT and REGEN buttons simultaneously for 3 seconds. 


A unique feature of this control valve is the ability to display actual water usage for the last 63 days. The values are initially stored as 
“----”. This means the value is unknown. As days pass values are stored as “0” for no flow or the actual number of gallons. The counting 
of the gallons starts at the regeneration time. If no regeneration time can be set (i.e. when the valve is set for immediate regeneration) the 
counting of gallons starts at 12 a.m. Day 1 is yesterday, day 2 the day before yesterday, etc. As new values are added the oldest history 
disappears. 


Another unique feature is that the valve automatically calculates a reserve capacity when set up as a softener with “Gallons 
Capacity" set to “AUTO” and the “Regeneration Time Option" set to “Normal” or “Normal + on 0”. The actual reserve capacity is 
compared to the gallons capacity remaining immediately prior to the preset regeneration time. A regeneration will occur if the actual 
reserve capacity is less than the gallons capacity remaining. The actual reserve capacity is calculated by using the estimated reserve 
capacity and adjusting it up or down for actual usage. 


The estimated reserve capacity for a given day of the week is the maximum value stored for the last three non-trivial water usages (i.e. 
more than 20 gallons/day) in seven day intervals. 





? See Installer Display Settings Step 3I, OEM Softener Setup Step 7S and OEM Filter Setup Step 6F for explanations of Day 
Override and Gallon Capacity. 


? Day Override and Gallon Capacity can not both be set to *oFF" at the same time. 


Page 8 WS1CS & WS1.25CS Manual 


OEM General Instructions 


The control valve offers multiple procedures that allow the valve to be modified to suit the needs of the installation. These 
procedures are: 


e OEM Softener Setup 

e OEM Filter Setup 

e Installer Displays & Settings 
e User Displays & Settings 

e Diagnostics 

e Valve History 


These procedures can be accessed in any order. Details on each of the procedures are provided on the following pages. 


At the discretion of the manufacturer, the field technician can access all settings. To “lock out" access to diagnostic and valve 
history displays and modifications to settings except hardness, day override, time of regeneration and time of day by anyone but 
the manufacturer, press W, NEXT, A, and SET CLOCK in sequence after settings are made. To “unlock”, so other displays can be 
viewed and changes can be made, press W, NEXT, A, and SET CLOCK in sequence. 


When in operation normal user displays such as time of day, gallons remaining or days remaining before regeneration are shown. 
When stepping through a procedure, if no buttons are pressed within five minutes the display returns to a normal user display. Any 
changes made prior to the five minute time out are incorporated. The one exception is current flow rate display under the diagnostic 
procedure. The current flow rate display has a 30 minute time out feature. 


To quickly exit OEM Softener Setup, OEM Filter Setup, Installer Display Settings, Diagnostic or Valve History press SET CLOCK. 
Any changes made prior to the exit are incorporated. 


When desired, all information in Diagnostics may be reset to zero when the valve is installed in a new location. To reset 
to zero, press NEXT and V buttons simultaneously to go to the Service/OEM 1 screen, and release. Press A and V 
simultaneously to reset diagnostic values to zero. Screen will return to User Display. 


Sometimes it is desirable to have the valve initiate and complete two regenerations within 24 hours and then return to the preset 
regeneration procedure. It is possible to do a double regeneration if the control valve is set to “NORMAL” or “NORMAL + on 0” in 


Step 8S or Step 7F. To do a double regeneration: 


1. Press the “REGEN” button once. REGEN TODAY will flash on the display. 
2. Press and hold the “REGEN” button for three seconds until the valve regeneration initiates. 


Once the valve has completed the immediate regeneration, the valve will regenerate one more time at the preset regeneration time. 


WS1CS & WS1.25CS Manual Page 9 





OEM Softener System Setup 
SET 


NEXT REGEN bos s : 
CLOCK | A V | This is a quick reference setup procedure. See OEM Softener System Setup Detail for more 
ii ud information on available settings. 

STEP 2S 


ae STEP 1S — Press NEXT and W buttons simultaneously for 3 seconds. If screen in step 2S 
does not appear in 5 seconds the lock on the valve is activated. To unlock press W, NEXT, 
A, and SET CLOCK in sequence, then press NEXT and W simultaneously for 3 seconds. 









































EUM NEXT A V REGEN STEP 2S — Choose Softening using V or A buttons. Press NEXT to go to Step 3S. Press 
REGEN to exit OEM Softener System Setup. 























a STEP 3S - Set Refill option using V or A buttons: 
REGEN D r1 D p e “PoST” to refill the brine tank after the final rinse; or 
Li J e “PrE” to refill the brine tank two hours before the regeneration time set. 


FILL 





Press NEXT to go to Step 4S. Press REGEN to return to previous step. 





SET 7 
dox | V | / | V | REGEN 
































STEP 4S — Program Code: Enter the desired program code from Table 2 or Table 3. 

r1 I Prior to selecting a Program Code, verify the correct valve body, main piston, regenerant 

| piston, and stack are being used, and that the injector or injector plug(s) are in the correct 
locations. See Compliance Table in WS1 and WS1.25 Drawings and Service Manual. 

Press NEXT to go to Step 5S. Press REGEN to return to previous step. 


SET 








SET 


crock || NT. | A \/ | REGEN 


SET CAPACITY 
c fT 
\/ || REGEN 


SET 
clock | NEXT | A 












































STEP 5S — Enter the ion exchange capacity in grains of hardness as calcium carbonate for 
the system based on test data using V or A buttons. Press NEXT to go to Step 6S. Press 
REGEN to return to previous step. 






































STEP 6S — Enter the pounds of salt per regeneration using W or A buttons. Press NEXT to 









































SET LBS go to Step 7S. Press REGEN to return to previous step. 
REGEN g D 
SET IX J REGEN STEP 7S — Set Gallons Capacity using V or A buttons: 
Crock e “AUTO” (reserve capacity automatically estimated and gallons capacity 


automatically calculated from grains capacity and water hardness); 



















































































SET e “OFF” (regeneration based on day override); or 
J l E r1 GAL * number of gallons (20 to 50,000). 
REGEN LJ J LJ See Setting Options Table for more detail. Press NEXT to go to Step 8S. Press REGEN to 
return to previous step. 
croc | Next | /\ | \/ | Regen 
i STEP 8S — Set Regeneration Time Option using V or A buttons: 
SETTIME * "NORMAL" means regeneration will occur at the preset time; 
P * "on 0" means regeneration will occur immediately when the gallons capacity reaches 
REGEN L1 l1 } Í O (zero); or 
= = * “NORMAL + on 0” means regeneration will occur at one of the following: 
NORMAL ; s : 
SET the preset time when the gallons capacity falls below the reserve or the specified number of 
dock | NEXT A | V REGEN * days between regenerations is reached whichever comes first; or 
i e after 10 minutes of no water usage when the gallon capacity reaches 0 (zero). 
RETURN TO See Setting Options Table for more detail. Press NEXT to exit OEM Softener System 
NORMAL Setup. Press REGEN to return to previous step. 


MODE 


Page 10 


Volume 
Capacity 


AUTO 


AUTO 


Any 
number 


OFF 


Any 
number 


AUTO 


Any 


number 


AUTO 


AUTO 


number 


= 
Se 


WS1CS & WS1.25CS Manual 


Setting Options Table 


Filters should only use shaded options 


Regeneration D 
: : Result 
Time Option Override 


v 
number 
number 


n 
number 

NORMAL on 0 
number 


ay 
FF 
E 
FF 
E 
FF 





Reserve capacity automatically estimated. 
Regeneration occurs when volume capacity falls below the reserve 
capacity at the next Regen Set Time 


Reserve capacity automatically estimated. 

Regeneration occurs at the next Regen Set Time when volume capacity 
falls below the reserve capacity or the specified number of days between 
regenerations is reached. 


Reserve capacity not automatically estimated. 
Regeneration occurs at the next Regen Set Time when volume 
capacity reaches 0. 


Reserve capacity not automatically estimated. 
Regeneration occurs at the next Regen Set Time when the specified 
number of days between regenerations is reached. 


Reserve capacity not automatically estimated. 

Regeneration occurs at the next Regen Set Time when volume 
capacity reaches 0 or the specified number of days between 
regenerations is reached. 


Reserve capacity not automatically estimated. 

Regeneration occurs immediately when volume capacity reaches 0. 
Time of regeneration will not be allowed to be set because regeneration 
will always occur when volume capacity reaches 0. 


Reserve capacity not automatically estimated. 

Regeneration occurs immediately when volume capacity reaches 0. 
Time of regeneration will not be allowed to be set because regeneration 
will always occur on 0. 


Reserve capacity automatically estimated. 

Regeneration occurs when volume capacity falls below the reserve 
capacity at the next Regen Set Time or regeneration occurs after 10 
minutes of no water usage when volume capacity reaches 0. 


Reserve capacity automatically estimated. 

Regeneration occurs at the next Regen Set Time when volume capacity 
falls below the reserve capacity or the specified number of days between 
regenerations is reached or regeneration occurs after 10 minutes of no 
water usage when volume capacity reaches 0. 


Reserve capacity not automatically estimated. 

Regeneration occurs at the next Regen Set Time when the specified 
number of days between regenerations is reached or regeneration occurs 
after 10 minutes of no water usage when volume capacity reaches 0. 





^Reserve capacity estimate is based on history of water usage. 


WS1CS & WS1.25CS Manual Page 11 


OEM Filter System Setup 


This is a quick reference setup procedure. See OEM Filter System Setup Detail for more 
information on available settings. 





ie NEXT A V REGEN STEP 1F — Press NEXT and Y simultaneously for 3 seconds. If screen in step 2F does not 


appear in 5 seconds the lock on the valve is activated. To unlock press W, NEXT, A, and 


























i SET CLOCK in sequence, then press NEXT and W simultaneously for 3 seconds. 
SET 
STEP 2F — Choose Filtering using W or A buttons. Press NEXT to go to step 3F. Press 
FILTERING REGEN to exit OEM Filter System Setup. 
SET 


























A NEXT | /N | \/ | REGEN 
+ 





STEP 3F - Set Refill option using V or A buttons: 

e “PoST” to refill the brine tank after the final rinse; or 

e “PrE” to refill the brine tank two hours before the regeneration time set. 
Press NEXT to go to step 4F. Press REGEN to return to previous step. 
































croc | Next | /N | \/ | REGEN 
STEP 4F — Program code: Enter the desired program code from Table 2, Table 5 or Table 6. 
Prior to selecting a Program Code, verify the correct valve body, main piston, regenerant 
r1 ( r1 piston, and stack are being used, and that the injector or injector plug(s) are in the correct 
Í Lf locations. See Compliance Table in WS1 and WS1.25 Drawings and Service Manual. Press 
NEXT to go to Step 5F. Press REGEN to return to previous step. 





SET 











SET 
clock | NEXT | A 



































STEP 5F — Enter “oFF” if regenerant is not used (i.e. backwash only) or enter the refill 
SET volume (in gallons) using V or A buttons. Press NEXT to go to step 6F. Press REGEN to 
r1 GAL return to previous step. 



































SET 
CLOCK E A V eee STEP 6F — Set Gallons Capacity using V or A buttons: 
e "oFF" (regeneration based on day override); or 


* number of gallons (20 to 50,000). 
See Setting Options Table for more detail. Press NEXT to go to step 7F. Press REGEN to 
return to previous step. 









































croc | Next | /N | \/ | REGEN m "uu 
db STEP 7F — Set Regeneration Time Option using V or A buttons: 
e "NORMAL" means regeneration will occur at the preset time; 












































SETTIME * "on 0" means regeneration will occur immediately when the gallons capacity reaches 
RS j 1 | 0 (zero); or 

REGEN L | J ( Li Í * "NORMAL + on 0” means regeneration will occur at one of the following: 
NORMAL * the preset time when the specified number of days between regenerations is 

SET reached; or 
EE T A V = e after 10 minutes of no water usage when the gallon capacity reaches 0 (zero). 

See Setting Options Table for more detail. Press NEXT to exit OEM Filter System Setup. 
RETURN TO Press REGEN to return to previous step. 
NORMAL 


MODE 


Page 12 





SET 
CLOCK 














SET 





HARDNESS 


[rer | A 
b4 

















SET 
CLOCK 




















REGEN 




















STEP 3I 







































































crock | NEXT | /N | MV | REGEN 
d 

SETTIME " 

^ a 

crock | Next | /N | \/ | REGEN 
i 

SETTINE 

REGEN 








eu 







































WS1CS & WS1.25CS Manual 


Installer Display Settings 
STEP 1I - Press NEXT and A simultaneously for 3 seconds. 


STEP 2I — Hardness: Set the amount of hardness in grains of hardness as calcium 
carbonate per gallon using the W or A buttons. The default is 20 with value ranges from 1 
to 150 in 1 grain increments. Note: The grains per gallon can be increased if soluble iron 
needs to be reduced. This display will show “—nA—” if “FILTER” is selected in Step 2F or 
if ‘AUTO’ is not selected in Step 7S. Press NEXT to go to step 3I. Press REGEN to exit 
Installer Display Settings. 


STEP 3I — Day Override: When gallon capacity is set to off, sets the number of days 
between regenerations. When gallon capacity is set to AUTO or to a number, sets the 
maximum number of days between regenerations. If value set to *oFF" regeneration 
initiation is based solely on gallons used. If value is set as a number (allowable range from 
1 to 28) a regeneration initiation will be called for on that day even if sufficient number of 
gallons were not used to call for a regeneration. Set Day Override using V or A buttons: 

* number of days between regeneration (1 to 28); or 

. “FP”, 
See Setting Options Table for more detail on setup. Press NEXT to go to step 4I. Press 
REGEN to return to previous step. 


STEP 4I — Next Regeneration Time (hour): Set the hour of day for regeneration using V or 
A buttons. AM/PM toggles after 12. The default time is 2:00 a.m. This display will show 
“REGEN on 0 GAL” if “on 0" is selected in Step 8S or Step 7F. Press NEXT to go to step 
5I. Press REGEN to return to previous step. 


STEP 5I — Next Regeneration Time (minutes): Set the minutes of day for regeneration us- 
ing V or A buttons. This display will not be shown if “on 0” is selected in Step 8S or Step 
TF. Press NEXT to exit Installer Display Settings. Press REGEN to return to previous step. 











































































































SET | ur | A V REGEN To initiate a manual regeneration immediately, press and hold the “REGEN” button for 
CLOCK £N : : : : 
I three seconds. The system will begin to regenerate immediately. The control valve may be 
stepped through the various regeneration cycles by pressing the “REGEN” button. 
RETURN TO E : » y TE . 
NORMAL 
MODE 
User Display Settings 
General Operation 
CAPACITY REMAINING REMAINING 
When the system is operating one of two displays will SOFTENING r1 
be shown. Pressing NEXT will alternate between the REGEN D GAL OR 
displays. One of the displays is always the current time TODAY DAY 
of day. The second display is one of the following: days SET | ^ v7 SET \ 

e M MN: NEXT | / \/ |) REGEN NEXT REGEN 
remaining or gallons remaining. Days remaining is the CLOCK ALY ELDER AV 
number of days left before the system goes through a 
regeneration cycle. Capacity remaining is the number of l 
gallons that will be treated before the system goes through TIME 
a regeneration cycle. The user can scroll between the REGEN TODAY will ra hJ 5 n 

i i i i REGEN = 
displays as desired. show if a regeneration TODAY 
is expected “Tonight. 
If the system has called for a regeneration that will occur E NEXT | A \/ REGEN | 


at the preset time of regeneration, the words REGEN 


TODAY will appear on the display. 





























When water is being treated (i.e. water is flowing through 
the system) the word “Softening” or “Filtering” flashes on 


the display if a water meter is installed. 


WS1CS & WS1.25CS Manual Page 13 


-g Bee 


BACKWASH 





Regeneration Mode 

Typically a system is set to regenerate at a time of low water usage. An example of a time 
with low water usage is when a household is asleep. If there is a demand for water when the 
system is regenerating, untreated water will be used. 








When the system begins to regenerate, the display will change to include information 
about the step of the regeneration process and the time remaining for that step to be completed. The system runs through the steps 
automatically and will reset itself to provide treated water when the regeneration has been completed. 


Manual Regeneration 
Sometimes there is a need to regenerate the system sooner than when the system calls for it, usually 
referred to as manual regeneration. There may be a period of heavy CAPACITY REMAINING 


water usage because of guests or a heavy laundry day. REGEN TODAY will r1 
Flash if a regeneration GAL 
REGEN Lj 


TODAY 








is expected “Tonight.” 





To initiate a manual regeneration at the preset delayed regeneration 

time, when the regeneration time option is set to “NORMAL” or 

& z « B x SET || NEXT a \/ | REGEN 
NORMAL + on 0”, press and release “REGEN”. The words “REGEN CLOCK V 

TODAY" will flash on the display to indicate that the system will 

regenerate at the preset delayed regeneration time. If you pressed the “REGEN” button in 

error, pressing the button again will cancel the request. Note: If the regeneration time option is set to *on 0” there is no set delayed 

regeneration time so “REGEN TODAY” will not activate if “REGEN” button is pressed. 






































To initiate a manual regeneration immediately, press and hold the “REGEN” button for three seconds. The system will begin to 
regenerate immediately. The request cannot be cancelled. 


Note: For softeners, if brine tank does not contain salt, fill with salt and wait at least two hours before regenerating. 





Set Time of Da 
NEXT A^ V REGEN The user can also set the time of day. Time of day should only need to be set after power 
CLOCK : : 
outages lasting more than 8 hours, if the battery has been depleted and a power outage 


occurs, or when daylight saving time begins or ends. If a power outage lasting more than 8 
SETTIME hours occurs, the time of day will flash on and off which indicates the time of day should 
hJ 0 PAN be reset. If a power outage lasts less than 8 hours and the time of day flashes on and off, the 























time of day should be reset and the battery replaced. 
































SET | uer | /N |) \ REGEN 
oe AV STEP 1U — Press SET CLOCK. 


$ 


SET TIME STEP 2U - Current Time (hour): Set the hour of the day using V or A buttons. AM/PM 


645 2i toggles after 12. Press NEXT to go to step 3U. 


STEP 3U - Current Time (minutes): Set the minutes of the day using W or A buttons. Press 


SET / i i 
cioe || NEXT A | V REGEN NEXT to exit Set Clock. Press REGEN to return to previous step. 









































Power Loss 

If the power goes out, the system will keep time for up to 8 hours or until the battery is depleted. If a power outage of more than 8 
hours occurs, the time of day will flash on and off which indicates the time of day should be reset. The system will remember the 
rest. If a power outage lasts less than 8 hours and the time of day flashes on and off, the non rechargeable battery should be replaced. 


Error Message 
If the word “ERROR” and a number are alternately flashing on the display contact the 


OEM for help. This indicates that the valve was not able to function properly. 





Error 


Hite 


















































































































































































































































































































































Page 14 
P 1D 
crock | NEXT | A | V. | REGEN 
a 
REGEN c 
DAY 
crock | Next | /\ |) V. | REGEN 
i STEP 3D 
342" 
REGEN 
crock | NET | /\ | V | Regen 
i STEP 4D 
DAY H h 
crock | Next | A | \/ | REGEN 
L STEP 5D 
DAY H 
crock | Nexr || /\ | V. | REGEN 
i STEP 6D 
EB: 
MIN 
croc | NET | /N | \/ | Regen 
i STEP 7D 
(ITa 
IL. (7 
croc | Next | /\ || V. | REGEN 
1 STEP 8D 
s: 
x1000 
croc | Next | /\ | VI. | REGEN 
i STEP 9D 
. Hi 
crock | Next | /\ | V. | REGEN 
I IS P 10D 
REGEN | g 
croc | Next |. /N || AZ | REGEN 



































i 


RETURN TO 
NORMAL MODE 


WS1CS & WS1.25CS Manual 


Diagnostics 
STEP 1D -Press V and A simultaneously for three seconds. If screen in step 2D does not appear 
in 5 seconds the lock on the valve is activated. To unlock press W, NEXT, A, and SET CLOCK in 
sequence, then press A and V simultaneously for 3 seconds. 


STEP 2D - Days, since last regeneration: This display shows the days since the last 
regeneration occurred. Press the NEXT button to go to Step 3D. Press REGEN to exit 
Diagnostics. 


STEP 3D - Gallons, since last regeneration: This display shows the number of gallons that 
have been treated since the last regeneration. This display will equal zero if a water meter is not 
installed. Press the NEXT button to go to Step 4D. Press REGEN to return to previous step. 


STEP 4D — Gallons, reserve capacity used for last 7 days: If the valve is set up as a softener, a meter 
is installed and Set Gallons Capacity is set to “Auto,” this 
ER 





display shows 0 day (for today) and flashes the reserve 
capacity. Pressing the A button will show day 1 (which 
would be yesterday) and flashes the reserve capacity 
used. Pressing the A button again will show day 2 (the 
day before yesterday) and the reserve capacity. Keep 
pressing the A button to show the gallons for days 3, 4, 5 
and 6. The W button can be pressed to move backwards 
in the day series. Press the NEXT button at any time to 
go to Step 5D. Press REGEN to return to previous step. 














15- 











STEP 5D - Gallons, 63 day usage history: This display 

shows day 1 (for yesterday) and flashes the number of 

gallons treated yesterday. Pressing the A button will 
show day 2 (which would be the day before yesterday) and flashes the number of gallons treated 
on that day. Continue to press the A button to show the maximum number of gallons treated for 
the last 63 days. This display will show dashes if a water meter is not installed. Press the NEXT 
button at any time to go to Step 6D. Press REGEN to return to previous step. 


STEP 6D - Flow rate, current: Turn the water on at one or more taps in the building. The flow 
rate in gallons per minute will be displayed. If flow stops the value will fall to zero in a few 
seconds. This display will equal zero if a water meter is not installed. Press the NEXT button to 
go to Step 7D. Press REGEN to return to previous step. 


STEP 7D - Flow rate, maximum last seven days: The maximum flow rate in gallons per minute 
that occurred in the last seven days will be displayed. This display will equal zero if a water meter 
is not installed. Press the NEXT button to go to Step 8D. Press REGEN to return to previous step. 


STEP 8D — Gallons, total used since last reset: The total number of gallons used since last reset 
will be displayed. This display will equal zero if a water meter is not installed. Press the NEXT 
button to go to Step 9D. Press REGEN to return to previous step. 


STEP 9D — Days, total number since last reset: The total number of days the control valve has 
been in service since last reset will be displayed. Press the NEXT button to go to Step 10D. Press 
REGEN to return to previous step. 


STEP 10D — Regenerations, total number since last reset: The total number of regenerations that 
have occurred since last reset will be displayed. Press the NEXT button to exit Diagnostics. Press 
REGEN to return to previous step. 


When desired, all information in Diagnostics may be reset to zero when the valve is installed 
in a new location. To reset to zero, press NEXT and V buttons simultaneously to go to the 
Service/OEM screen, and release. Press V and A simultaneously to reset diagnostic values 
to zero. Screen will return to user display. 


WS1CS & WS1.25CS Manual Page 15 


STEP 1VH 



























































SET 
NEXT REGEN 
EE A V Valve History 
y STEP 1VH - Press V and A simultaneously for three seconds and release. Then 
P press V and A simultaneously and release. If screen in step 2VH does not appear in 
SET 5 seconds the lock on the valve is activated. To unlock press V, NEXT, A, and SET 
crock | NEXT | /\ || \/ | REGEN 
CLOCK in sequence, then press W and A simultaneously for 3 seconds and release. 








Then press W and A simultaneously and release. 





STEP 2VH - Software Version: This display shows the software version of the valve. 
Press the NEXT button to go to Step 3VH. Press REGEN to exit Valve History. 


-L 
TI 
LMI 





STEP 3VH? - Flow rate, maximum since startup: This display shows the maximum 






































flow rate in gallons per minute that has occurred since startup. This display will equal 
SEC) next || /\ || V. | REGEN TNR 
CLOCK zero if a water meter is not installed. Press the NEXT button to go to Step 4VH. Press 
ag REGEN to return to previous step. 





STEP 4VH - Gallons, total used since start-up: This display shows the total gallons 
treated since startup. This display will equal zero if a water meter is not installed. 
Press the NEXT button to go to Step 5VH. Press REGEN to return to previous step. 


e 
5e 
= 


4 











a 














/ | REGEN 











ET | next | A 
CLOCK STEP 5VH - Days, total since start-up: This display shows the total days since 
l startup. Press the NEXT button to go to Step 6VH. Press REGEN to return to 
previous step. 






































| c q D SE STEP 6VH - Regenerations, total number since start-up: This display shows the total 
x1000 number of regenerations that have occurred since startup. Press the NEXT button to 
E | — ^ | V nn go to Step 7VH. Press REGEN to return to previous step. 
i STEP 7VH - Error Log: This display shows a history of the last 10 errors generated 
by the control during operation. Press the W or A buttons to review each error 
71 rl recorded. Press the NEXT button to exit Valve History. Press REGEN to return to 
Í LJ previous step. 
DAY 








SET E7 
chock | NExT | /N | \/_ | REGEN 


- 275 
































aE] 











SET 


clock | NEXT 


\/ | REGEN 























E (uu 


crock | NEXT | /\ | V. | REGEN 


RETURN TO 
NORMAL 
MODE 








m | 48] 





















































5 Values in steps 3VH through 7VH cannot be reset. 


Page 16 WS1CS & WS1.25CS Manual 


CS Front Cover and Drive Assembly 

























































































Drawing No. | Order No. Description Quantity 
1 V3175-01 | WS1 FRONT COVER ASY 1 
2 V3107-01 | WSI MOTOR 1 
3 V3106-01 |WSI DRIVE BRACKET & SPRING CLIP 1 
4 V3108CS-01 | WS1/125 CS PC W BAT 1 
5 V3110 WS1 DRIVE REDUCING GEAR 12X36 3 
6 V3109 WS1 DRIVE GEAR COVER 1 
V3002 WS1 DRIVE ASY n 
Not Shown V3186 WS1 AC ADAPTER 110V - 12V 1 
AC Adapter US. International 
Supply Voltage 120 VAC 230V AC 
Supply Frequency 60 Hz 50 Hz 
Output Voltage 12 VAC 12 VAC 
Output Current 500 mA 500 mA 
When replacing the battery, align Correct 
positives and push down to fully seat. Battery | <— Battery replacement is 
Orienta- 3 volt lithium coin cell 


tion 





type 2032. 









































WS1CS & WS1.25CS Manual Page 17 


WSICS Drive Cap Assembly, Downflow Piston, Upflow Piston, Regenerant Piston and Spacer Stack Assembly 


1 
2 
3 
a 
b 


| 8 — | V3I05 | O-ring 215 (Distributor Tube) 
V3001 | WS1 Body ASY Downflow nm 


V3011-01* | WS1 Piston Upflow ASY 


V3001-02 | WS1 Mixing Valve Body ASY 
Not Shown 1 
V3001UP | WS1 Body ASY Upflow 
V3001-02UP | WS1 Mixing Valve Body Upflow ASY 
V3013 | WS1 Mixing Valve ASY 


*V3011 is labeled with DN and V3011-01 is labeled with UP. 
Note: The regenerant piston is not used in backwash only applications. 

















Black Plug 





Page 18 WS1CS & WS1.25CS Manual 


WS1.25CS Drive Cap Assembly, Downflow Piston, Upflow Piston, Regenerant Piston and Spacer Stack Assemblies 




































































Drawing No. Order No. Description Quantity 
la V3430 WS1.5 Spacer Stack Assembly i 
1b V3005 WSI Spacer Stack Assembly 
2 V3004 Drive Cap Assembly 1 
3 V3178 WS1 Drive Back Plate 1 
4a V3407 WS1.5 Piston Downflow Assembly 
4b V3011-01 WSI Piston Upflow Assembly : 
5 V3174 WSI Regenerant Piston 1 

V3135 O-ring 228 1 
7 V3180 O-ring 337 1 
g V3358 O-ring 219 (Distributor tube opening 1.32”) i 
V3357 O-ring 218 (Distributor tube opening 32mm) 
V3020 WS1.25 Body Assembly Downflow (Distributor tube opening 1.32") 
V3020-01 WS1.25 Mixing Valve Body Downflow Asy (Distributor tube opening 1.32") 
Net Show V3020-02 WS1.25 Body Assembly Downflow (Distributor tube opening 32mm) i 
V3020-03 WS1.25 Mixing Valve Body Downflow Asy (Distributor tube opening 32mm) 
V3020UP WS1.25 Body Assembly Upflow (Distributor tube opening 1.32") 
V3020-02UP | WS1.25 Body Assembly Upflow (Distributor tube opening 32mm) 


Note: The regenerant piston is not used in backwash only applications. 


Grey Plug on all 
WS1.25 bodies 


*Grey Ring 


*Grey Distributor 
O-ring retainer 


© 9 





*Only for valves that have a 
32mm Distributor Tube Opening 


WS1CS & WS1.25CS Manual Page 19 


WS1 & WS1.25 Identification Figure 


WSI with 1.050" Distributor Tube Opening Identification 


Spacer Color: 
Grey 





x 
1.25" 
v 


Black Plug Note: The WS1 downflow piston is a solid 
amber color. The WS1 upflow piston is black 


and amber. 


WS1.25 with 1.32" Distributor Tube Opening Identification 


Down flow and Backwash 


Spacer Color: 
Black 


1.5" 





Grey Plug 


Upflow 


Spacer Color: 
Grey 





Note: The WS1 downflow piston is a solid 
amber color. The WSI upflow piston is black 
and amber. 


WS1.25 with 32mm Distributor Tube Opening Identification 


Down flow and Backwash 


Spacer Color: 
Black 


AW tg 





Grey Plug 
Grey Distributor O-ring Retainer 


Upflow 


Spacer Color: 
Grey 








Note: The WS1 downflow piston is a solid 
amber color. The WSI upflow piston is black 
and amber. 


Page 20 WS1CS & WS1.25CS Manual 


Revision History: 


4/2/2009 


PAGE 5: 
Added P50-P52 Program Codes 


10/6/2011 


PAGE 3: 
TOC - WS1.25CS Drive Cap Asy, Pistons and Spacer Stack Asy 


PAGE 4: 
Added - or the WS1.25 
removed - The WS1.25 control valve is only available in downflow regeneration. 


PAGE 6: 
Added - Table 3 Upflow Softener Program Codes for WS1CS or WS1.25CS 


PAGE 9: 
Step 4S -Removed the Note: 


PAGE 18: 
New Table and Drawing - Added WS1.25CS upflow information 


PAGE 19: 
Modified Drawings - Added WS1.25CS upflow information 


Form No. V3115CS * 10/6/2011