Milli-Q® Direct Water Purification System 


Pure & ultrapure water directly from tap water 





EMD Millipore is a division of Merck KGaA, Darmstadt, Germany 





Pure & ultrapure water from a single water system 


Scientists’ needs: 


Scientists need a system that can deliver pure and ultrapure 
water directly from tap water at the right price: 

e meeting increasing quality standards 

e providing convenience 

è optimizing lab space 

e allowing low running costs 


Optimum water production 
Pure water 


Tap water is first purified to pure (Type 3) water by reverse osmosis 
(RO) using techniques designed and optimized by EMD Millipore: 
e Progard® pretreatment cartridge validated to extend the 
lifetime of the RO cartridge. 

e Reject recirculation loop that recycles reject water treated by the 
Progard® to minimize tap water usage (recovery up to 66 %)* and 
extend Progard® lifetime while avoiding fouling or scaling issues 
that might shorten the RO cartridge lifetime. 

e Unique system adaptation to feed water temperature in order to 
avoid flow rate decrease during the wintertime when tap water is 
colder. 

e Unique safety device ensuring that only low ionic permeate 
water will be sent to the tank in order to warrant adequate pure 
water quality and to increase the lifetime of the ion-exchange 
cartridge used to produce ultrapure water. 

e Complete process monitoring system that systematically checks 
water temperature, pressure, conductivity and RO rejection using 
calibrated meters at different steps. 


Ultrapure water 


e Water is purified in a first step using unique Jetpore® ion- 
exchange resin, synthetic activated carbon and a UV lamp 
emitting at 185 and 254 nm to reach a resistivity of 18.2 MQ.cm 
at 25° and a TOC value below 5 ppb; both values are monitored by 
advanced analytical techniques. 

e This water is sent through a small recirculation loop to the 
Application Pak, where a final purification step, critical for specific 
expriments, removes contaminants just before water leaves the 
system. 


“depending on feed water quality 


The Milli-OQ® Direct answer: 


The Milli-OQ® Direct is designed as a single water system which produces 
pure and ultrapure water directly from tap water. The system: 

e exceeds the requirements of the most demanding norms 

e provides manual and volumetric water dispense at low and 
high flow rate 

e has a low footprint: wall-or bench-integrated installation 

e allows optimized global costs 


The pure water produced by reverse osmosis is stored in a tank 
designed to minimize risks of contamination during water 
storage. EMD Millipore's tank level sensor will allow the system 
to automatically start or stop producing water when you want 
to and will accurately display the tank's water level on the 
system's screen. Safety devices prevent overflow or the system 
from running dry. 


From the reservoir, water can be sourced though a front valve, 
sent by a delivery pump to feed instruments such as a glassware 
washing machine, or further processed by the Milli-Q® Direct 
to produce ultrapure (Type1) water. 


Convenience in water delivery: 





Easily prepare solutions with the 
low flow function to precisely 
adjust the meniscus in volumetric 
flasks. 


The 75 cm long tubing reaches the sink 
for easy glassware washing at mid or 
w~ high flow (up to 2 | per mn). 





Save time with the volumetric 
function automatically delivering 
the water volume you need, and 
the dispensing arm designed to 
fit the height and shape of all 
laboratory glassware. 


Deliver water hands-free using the 
footswitch option for more convenience. 





Select an Application Pak to get the best adapted media for your research: 
BioPak®, VOC-Pak™, EDS-Pak®, LC-Pak™, Millipak® polishers. 


BioPak® Polisher 


Pyrogen-free and 
nuclease-free water 


Catalogue N°: 
CDUFBIOO1 


VOC-Pak™ Polisher 


Water for volatile 
organic compounds 
analysis 


Catalogue N°: 
VOCPAKOO1 


EDS-Pak® Polisher 


Water for endocrine 
disrupters 
experiments 


Catalogue N°: 
EDSPAKOO1 


LC-Pak™ Polisher 


Water for ultratrace 
organic analysis 


Catalogue N°: 
LCPAKO001 


Millipak® Polisher 


Bacteria-free and 
particulate-free 
water 


Catalogue N°: 
MPGPO4001 





Milli-OQ® Direct System at a glance 


Dispenser removable from l l 
support E High recovery Reverse Osmosis for 


Built-in UV 185 nm lamp for pure water production at low cost 
TOC reduction & measure 







Application Pak adapted 
to specific contaminants 


removal Large digital & graphic screen with 


detailed procedures for full online 
support 


! E ā 
Milli-Q | 
Progard® pretreatment cartridge to 


increase RO module lifetime - with 
RFID tag for safety & traceability 


Consistent delivery of Ultrapure quality water 
adapted to your needs at low or high flow rate 
Q-Pak® polishing cartridge 
adapted to general application 
- with RFID tag for safety & 
traceability 


Dispenser on support adapted to glassware e 


Quick Reference Guide with all 
height and shape for automatic volume delivery ul uide wi 


needed information in left door 


1. Tap water feed 16. Resistivity & temperature measure for ultrapure 
2. Inlet Solenoid Valve 9. Permeate conductivity cell water TOC indicator 


3. Progard® pretreatment pack 10. 3-way solenoid valve 17. Q-Pak® polishing cartridge 

4. Booster pump 11. UV lamp 254 nm (optional) 18. Ultrapure water resistivity and temperature 

5. Measure of feed water conductivity and 12. Tank for Type 3 water storage measure 

temperature 13. Recirculation & delivery pump 19. Ultrapure water dispenser 

6. Reverse Osmosis cartridge(s) 14. UV lamp 185 nm 20. Application Pak polisher adapted to application 
7. RO reject recovery loop 15. 3-way solenoid valve - part of the TOC indicator 





Easy access to information 


e Simplified and detailed information in 
(local language). 

e Alerts & alarms (which can be enhanced 
by a buzzer) are visible on the system's main 
screen, with complete information on actions 
required accessible at the touch of a finger. 

e Sensors regularly monitor the operation of 
the system to ensure it operates within speci- 
fications. For instance, if ionic contamination 
of feed water exceeds specifications, causing 
high conductivity, the built-in Feed Water 
Conductivity Meter will trigger an alarm to 
alert you. 








e Clear graphics help you perform specific 
tasks such as maintenance. From the same 
screen, you can even print reports on the 
system's water quality and history. 







Maia =| 


e Critical information such as set points or 
units is accessible only to the designated 
responsible user and is protected by a login 
and a password. 

e Automatically stop ultrapure water dispense 
after a fixed time period set by the user, in 
order to avoid water loss or lab flooding. 






ote Pal gh JEn madj | 
qretiebeg ri saa | 
ETB a=. 


aa a | 
2 SS 
Praag s ia mart | 


| ee 








A Quick Reference Guide located in the door 
of the Milli-OQ® Direct water system provides 
all the information required to understand 
the operation and maintenance of the system. 


The system comes with a complete and 
detailed user manual in 8 languages on CD- 
ROM. A printed manual contains essential 
information in (local language). 





Easy and reduced maintenance 


Maintenance frequency is minimal, and the procedures are simplified. 


q 
p è = 
l Mil li =f 
j 


Progard® Pack 
replacement 


Mi= | i 


replacement 


» Millipak® Express 
40 replacement 





Service 


e Progard® pretreatment pack or the Q-Pak® polishing cartridge 
replacement takes less than 5 minutes. 


0-Pak® e Quick and easy traceability thanks to RFID tag which 
polishing automatically registers the catalog and other new consumables in 
cartridge the system's memory. 


e The system will alert you to replace consumables or schedule 
service visits at least 15 days before maintenance is actually 
required. 


EMD Millipore provides a comprehensive range of service programs performed by certified EMD Millipore field 
service Support engineers to thoroughly maintain and qualify your Milli-Q® system for full compliance with 


your industry's regulatory standards. 


The service program portfolio covers all maintenance requirements such as installation, customized user 
training, scientific and technical support, troubleshooting, preventive maintenance visits, and all validation 
requirements using ad hoc calibrated equipment, procedures, workbooks and suitability tests within a GXPs 


environment. 


Safety 


The Miulli-O® Direct system is tested by an 
independent and accredited company for 
compliance with the CE directives related to safety 
and electromagnetic compatibility. 

A certicate is delivered with the system and 
the report can be consulted on request at the 
manufacturing site. 

The Milli-O® Direct system is built using components 
and practices recommended by UL and has been cUL 
marked. The registration can be verified on the UL 
web site (http://www.ul.com). 


Certification 


The Milli-OQ® Direct system is delivered with a 
Certificate of Conformity ensuring that it has been 
built and tested fully assembled following EMD 
Millipore Standard Operating Procedures, and a 
Certificate of Calibration for the temperature and 
resistivity meters built in the system. The Milli-Q® 
Direct consumables are automatically delivered 
with a Certificate of Quality. 

EMD Millipore's manufacturing site is ISO 9001 
v.2000 and ISO 140001 certified. 


MILLI-Q® DIRECT SPECIFICATIONS 


Feed Water Specifications Type 3 Water production and delivery 




















Parameter Value & Unit Parameter Value & Unit 
Feed water quality Potable Tap Water Feed 8 |/hour 
Feed Water Conductivity < 2000 uS/cm at 25°C Production Flow Rate ic Direct 8) 
Feed Water TOC < 2000 ppb (Milli-O® Direct 16) 
Feed Water Pressure 1 - 6 bar From tap: 
Feed Water Temperature 5- 35°C up to 2.5 I/min 
Feed Water Chlorine < 3 ppm(*) Delivery Flow rate ee 
Feed Water Fouling Index < 12 up to 15 l/min at 
Feed water pH 4 to 10 pH units 1 bar 
Feed Water Connection 1/2 in Gaz M 

(*) Feed Water Chlorine < 1ppm with Progard® T3 and < 3ppm with Progard® Milli-Q® Direct System Dimensions 

T3 + Prepak 1 

Parameter Value & Unit 


Type 1 Product Water Quality 


System footprint 1606 cm2 (249 in2) 























Parameter Value & Unit system height l 
Sg e Cabinet (base) 497 mm (19.56 in) 
Resistivity 18.2 MQ.cm at 25 °C © Dispenser arm (top) 713 mm (28.07 in) 
Toc < 5 ppb (ug/l) System width 
Bacteria = < 0.1 cfu/ml e Cabinet (base) 332 mm (13.07 in) 
PE e Dispenser arm (top) 413 mm (16.25 in) 
(endotoxins) "= iliac i t ba 484 mm (19.05 in) 
HHKK ® Caoine ase mm . in 
RNases < 0.01 ng/ml (RNase-free) e Dispenser arm (top) 581 mm (22.87 in) 
DNases**** < 4 pg/ul (DNase-free) 24/25 k 
System weight (packaged) 8/16 9 
* Resistivity can be displayed temperature-compensated at 25 °C or non- á 2 i 7 (52.91/55.11 Ib) 
temperature-compensated as required by USP Syst one ty) 8/16 20/21 kg 
* TOC specs - Test Conditions: Milli-O® Direct System equipped with Progard® T3 ee aL ol (44.09/46.29 Ib) 
pretreatment pack and Q-Pak® TEX polishing cartridge and with feed (tap) water 27/28 kg 


quality within specifications. Product water quality may vary due to local feed System weight (with water) 8/16 
water conditions. 
*™* Results with Millipak® express 40 or BioPak® final polisher in place 


“* Results with BioPak® final polisher in place 


(59.52/61.73 Ib) 


Dispenser delivery loop length 750 mm (29.52 in) 


Electrical power supply cable 


290 cm (114.1 in) 
. length 
Type 1 Water Delivery 


Electrical power supply voltage 100 - 230 V + 10 % 





Parameter Value & Unit Electrical power supply frequency 50 - 60 Hz + 10 % 
. Adjustable between 50 and Feed water connection 1/2 in. Gaz F 
Manual dispense flow rate i 
2000 ml/min 


Data connection Ethernet (RJ45) 








100 ml, then 250 ml to 5 | 
by 250 ml increments 
5 | to 60 I by 1 | increments 


Automatic dispense volume 


Q-POD ® Accessory Dimensions 
3% for volumes between 
250 ml and 60 | 


0 
Volumetric dispense dispersion CV < 3% for volumes 


Volumetric dispense accuracy Vel lan 


579 mm (23.50 in) 
230 mm (9.05 in) 


Parameter 
Q-POD® height 


between 250 ml and 60 | O-POD® diameter 





Dispenser delivery loop length 800 mm (31.49 in) 





Q-POD® weight (packaged) 
Q-POD® weight (empty) 


7.2 kg (15.87 lb) 


Type 3 Water Quality 5 kg (11.02 Ib) 


Parameter 


Value & Unit 


97 to 98% with new RO 


lons rejection 


cartridge 





Organics Rejection 


> 99% for MW > 200 Dalton 
> 99% 


Particulates & Bacteria Rejection 


Q-POD® weight (with water) 


Loop & cable to system length 


5.5 kg (12.12 Ib) 
290 cm (114.1 in) 





Data connection Parallel Port 


(25-pinD-Sub) 
for print-out 


A report on conformity of Milli-O® Direct water quality with Type 1 water 
quality as described by ASTM®, ISO® 3696 and CLSI® norms and to Purified 
Water as described in USP and EP is available upon request. 


ACCESSORIES 


Customize your Milli-O® Direct system to meet your 
specific needs. 


Reservoirs 

© Select from the range of EMD Millipore tanks from 30 | to 350 
| designed for optimum pure water storage. 

Q-POD® Dispenser: Ultrapure water delivery at your fingertips 
e Save your bench space by removing the arm and dispenser 


from the Milli-O® Direct system and mounting it on the 
Q-POD® support. 





Q-POD® dispenser key features: 


e Variable water flow (slow flow to 2 l/min) controlled by 
plunger. 

e Volumetric water delivery controlled from the Q-POD® base. 
e Designed to accommodate all sizes of glassware - 250 ml 
cylinder, 5 | flask or even a 30 | carboy. 

e Graphic display shows at a glance the water quality 
specifications and all critical information you need (resistivity, 
TOC level, alerts, alarms, etc.). 

e Printer connection to instantly record water quality history. 


For more information, please visit our website: 
www.millipore.com/labwater 


Wall Mounting Bracket 


e Save space by installing the Milli-OQ® Direct on the wall or under 
the bench. 





Milli-OQ® Direct with Wall Mounting Bracket and 
Q-POD® 


Protectors: 


e Water Sensor - placed on the floor, this sensor stops water feed 
to the system if there is water on the floor. 

e Tank Level Sensor - transfers tank level information to the 
system to start & stop pure water production at levels selected 
by the user. A safety level prevents air from entering the ultrapure 
water part when the tank is empty. 

e Silicone Cover to protect your Q-POD® from harsh chemicals, 
such as strong acid & bases, aggressive solvents or etchants. 

e UV lamp 254 nm: installed upstream from the inlet to the tank, 
this optional UV lamp allows reduction of the level of bacteria in 
the permeate water by a factor of 1000. 


Footswitch 


e Connect the footswitch to the base of the Q-POD® dispenser or 
directly to the Milli-Q® system for hands-free water delivery: press 
once to start and once to stop. 





—— 


Millipore, Milli-Q, Progard, Jetpore, BioPak, EDS-Pak, Millipak, Q-POD, Q-Gard, Quantum, and Q-Pak are registered trademarks of Merck 
KGaA, Darmstadt, Germany. VOC-Pak, LC-Pak, EMD Millipore and the M mark are trademarks of Merck KGaA. ASTM, ISO, and CLSI are 


registered trademarks of their respective owners. 
Lit. No. PB1032ENUS 01/12. 
© 2012 EMD Millipore Corporation, Billerica, MA. All rights reserved.