Thermo Scientific Waterbook
Lab Water 101 E
H.O. It’s such a simple compound.
So why settle for a complicated lab water system?
Thermo Scientific Barnstead water purification systems
deliver pure and ultrapure water - with ease. With flexible
systems designed precisely for your applications, and multiple
water types from a single solution. Plus simple, efficient
operation without the need for maintenance plans, and
innovations like UV intensity monitoring to ensure accurate
total organic carbon (TOC) readings. It’s no surprise that the
smart choice in cost-effective lab water systems is the
familiar name you already trust.
Introduction 2
Thermo Scientific™ Barnstead™ Water Purification Technologies 6
Distillation, Filtration and Ultrafiltration, Reverse Osmosis
Deionization, Electrodeionization, Adsorption, Ultraviolet Oxidation
International Water Standards 14
Advanced Technologies Used to Monitor Purity 15
Conductivity and Resistivity
Build Your Own Water System 16
What Type of Water Do You Need?
Ultrapure (Type 1) Water
Pure (Type 2) Water
Reverse Osmosis (RO) Water
Cartridge and Filter Systems
Lab Case Studies
|
Thermo Scientific E
Water Purification
Products
Thermo Scientific Type 1 Ultrapure Water Purification Systems
Barnstead GenPure™ xCAD Plus
Barnstead GenPure Pro
Barnstead GenPure
Barnstead MicroPure™
Barnstead E-Pure™
Barnstead LabTower™ EDI
Barnstead Smart2Pure™
Thermo Scientific Type 2 Pure Water Purification Systems
Barnstead Pacific™ TII
Barnstead LabTower TII
Barnstead Mega-Pure™ Glass Stills
Barnstead Classic Stills
Barnstead Classic Still Storage Reservoirs and Accessories
Barnstead Cabinetized Stills
Barnstead Distillation 101
Thermo Scientific Reverse Osmosis Water Purification Systems
Barnstead LabTower RO
Barnstead Pacific RO
Pretreatment
Thermo Scientific Cartridge and Filter Systems
Barnstead B-Pure™
Barnstead Bantam™ Deionizer
Barnstead Hose Nipple Cartridges
Barnstead B-Pure 1/2 Size Filters
Legacy Water System Consumables
Type 1 systems
Type 2/3 systems
Support and Maintenance
Contact the Lab Water Experts
Services
Go Green
Common Conversions
Glossary
www.thermoscientific.com/purewater
+ a
$
22
26
30
34
38
42
44
48
52
56
60
64
68
70
72
73
74
80
82
86
92
96
100
101
102
104
104
105
106
106
107
108
109
110
ELAVE S
experts
For more than 130 years, Thermo Scientific lab water systems have
been a trusted resource for science and industry. Our complete line
of water purification technologies includes solutions for your most
critical and everyday application needs, from electrodeionization to
reverse osmosis and distillation.
Thermo Scientific Barnstead lab water systems deliver:
innovation
Our water purification portfolio features advanced ergonomics and
technology, including remote dispensing and UV intensity monitoring —
that offer users full control with confidence.
flexibility
Laboratory environments often have limited bench space. Our portfolio
offers numerous mounting options, small footprints and flexible
dispensing options to provide you the luxury of designing a configuration
that best suits your lab. Many water systems can be easily upgraded to
allow for additional capacity.
convenience
Our Thermo Scientific H20 Select™ analysis program and complete
all-in-one box ordering gives you the confidence to select the right
solution. Receive a complete water system using one part number and
have the components you need to easily maintain your new water
purification system.
innovation
that deliver accuracy
With innovative water monitoring
technology, Thermo Scientific water
purification systems eliminate expense
and lost time which may occur with
contaminated lab water.
Advanced feed water monitoring
Alerts the user to fluctuations in the
feed water quality. Poor feed water
will reduce cartridge life.
TOC measurements with
UV intensity monitoring
Continuously monitoring and
recording TOC measurements in
real-time, this technology ensures
ultrapure water that meets or exceeds
even the most stringent requirements
for sensitive applications. A photo
sensor continually checks the intensity
of the UV lamp. A drop in measured
UV radiation can result in an incorrect
TOC measurement.
EDI systems feature tank
recirculation to maintain high
purity water even during
long periods of inactivity
Automatic recirculation of the water
in the tank across a special polisher
actively protects against bacteria
growth even during long periods
of inactivity.
flexibility
system design
Mounting flexibility
Installation options include under the
cabinet, on the wall, on the bench,
or free-standing units with wheels
for added mobility.
Full system control at the
Thermo Scientific xCAD
remote dispenser
Eliminate the hassle of going back
to the primary system to adjust
parameters.
Upgradeable units
Growing the lab or planning for
changing needs? Many of our
systems can be upgraded to
accommodate greater capacity.
Dual water quality
Need more than one type of water?
Many of the systems produce two
types of water from just one system.
www.thermoscientific.com/purewater
convenience
with customized system selection
Based on the results of a Thermo Scientific
H2O Select analysis, we will recommend the
best water system for your application based
on your feed water quality, laboratory
applications, daily volume requirements and
budget. We do all the thinking for you.
How it works:
1.
Contact your local sales representative for
a complimentary H2O Select analysis kit.
. Fill the sample bottle with your anticipated
feed water.
. Answer the short questionnaire pertaining
to your water requirements, applications
and budget.
. Place the completed application and
water sample bottle in the return box. Add
postage and mail to the Thermo Scientific
Barnstead Water Lab (return label
included in box).
All-in-one-box ordering
Have confidence in knowing that there are
no surprises with added post sale costs.
Everything you need ships under one part
number!
Easy self maintenance
The Aquastop quick connections make
changing your cartridges quick and simple.
Sand, silt, clay and other
suspended particles cause water
to be turbid. These suspended
particles can interfere with
instrument operation, plug valves
and other narrow flow paths,
and foul reverse osmosis
membranes. They typically range
from 1 — 10 um in size.
Colloidal particles typically have a
slightly net negative charge,
range in size from 0.01 — 1.0 um,
and can be either organic or
inorganic. Unlike suspended
particles, colloids do not settle out
by gravity, but remain suspended
in the liquid that carries them.
Colloids clog filters, interfere with
instrument operation, foul reverse
osmosis membranes and can
bypass ion exchange resins,
resulting in lower resistivity in
deionized water systems.
Don't let impurities contaminate your sensitive
experiments. Thermo Scientific Barnstead water
purification systems are engineered to remove
impurities that threaten your research so you can
focus on what's important — your next discovery.
Impurities such as silicates, chlorides,
fluorides, bicarbonates, sulfates,
phosphates, nitrates and ferrous
compounds are present as cations
(positively charge ions) and anions
(negatively charged ions). Water
with a high concentration of ions
will conduct electricity readily and
have high conductivity and low
resistivity, as conductivity and
resistivity are inversely related. lons
will adversely affect the results of
inorganic analyses such as IC, AA,
ICP/MS and may retard cell and
tissue growth in biological research.
They can also affect the cartridge
life in deionized water systems.
Organic solids are present from
plant and animal decay and
from human activity. They may
include proteins, alcohols,
chloramines and residues of
pesticides, herbicides and
detergents. They foul ion
exchange resins, interfere with
organic analyses including
HPLC, gas chromatography and
fluoroscopy. They will also
hinder electrophoresis, tissue
and cell culture.
Speaking the Language of Lab Water
Application and Interest Areas
General Lab Purpose
Autoclave
Humidification
Glassware washing/rinsing
Media preparation
Analytical
lon chromatography (IC)
Atomic absorption (AA)
High performance liquid chromatography (HPLC)
Inductively coupled plasma spectroscopy (ICP)
Mass spectroscopy (MS)
Gas chromatography (GC)
Total organic carbon (TOC)
Life Sciences
Proteomics (ex. crystallography, electrophoresis)
Immunology (ex. monoclonal antibody production, blots)
Pharmacology
Cell and tissue culture
Drug discovery
Dissolved Gases
Water naturally contains
dissolved gases such as carbon
dioxide, nitrogen and oxygen.
Carbon dioxide dissolves in
water to form weakly acidic
carbonic acid (H2C03), which
can alter the pH of the water.
Additionally, oxygen, the most
common non-ionized gas, may
Cause corrosion of metal
surfaces.
Contaminants to Avoid in Your Lab Water
gases
Genomics (ex. PCR, mutagenesis)
Microorganisms
Bacteria, fungi and algae are
found in all natural water sources.
Chlorination eliminates harmful
bacteria, but tap water still
contains live microorganisms
which interfere with sterile
applications, such as cell and
tissue culture.
D
Pyrogens and Viruses
Pyrogens or bacterial
endotoxins are
lipopolysaccharide molecules
incorporated in the cell
membrane of gram negative
bacteria. Viruses are considered
to be non-living nucleic acids.
Both can adversely affect
laboratory experiments often
hindering cell and tissue growth
in culture.
www.thermoscientific.com/purewater
a
f-
E
E
h
q
p 4
a
$
Nucleases
RNase and DNase are naturally
occurring enzymes that are
instrumental in regulating bodily
functions. As important as these
enzymes are to the life process,
they can be devastating to nucleic
acid experiments. If these
contaminants are present in the
lab water used, the ability to
amplify DNA molecules will be
severely limited. Likewise,
experiments utilizing RNA can
be ruined.
To make pure and ultrapure water, the impurities discussed on the previous page must be
efficiently and effectively removed. Barnstead water purification systems employ multiple
technologies, some synergistically, to remove impurities and give you consistently PURE water.
Water purification is a step-by-step process often requiring a combination of
technologies, each of which varies in the ability to remove specific contaminants.
The table below illustrates which impurities are removed by each technology.
Electri- Ultrafiltrati Ultraviolet Combinat
Distillation i ah Deioization | anon | Filtration et n Adsorption ; cm Te
= pE
J a
— pr
-—
= Pm
— PW
Nucleases Ô À.
> &
TER.:
DG- D- Ge
a
G-- Gin
ee ec &
eee Bae
Tt O > ©
speaking the Language of Lab Water
Thermometer
Receiver Condenser
Distillate
Heat Source
A basic distillation diagram.
Distillation
Distillation has the broadest removal capabilities
of any single form of water purification.
Water is boiled and undergoes phase changes during the
distillation process, changing from liquid to vapor and back to
liquid. It is the change from liquid to vapor that separates the
water (in various degrees) from many dissolved impurities,
such as ions, organic contaminants with low boiling points
< 100°C , bacteria, pyrogens and particulates. Distillation can
not be used on its own to remove inorganic ions, ionized
gases, organics with boiling points higher than 100°C , or
dissolved non-ionized gases.
Benefits
e Offers the broadest removal capabilities
of any single form of water purification
: Classic Stills
e Requires no consumables
Limitations
e Requires periodic maintenance and manual cleaning of
system to maintain water purity
e Requires water for cooling
Systems that utilize this technology
e Thermo Scientific Barnstead Classic Stills and
Mega-Pure Stills
www.thermoscientific.com/purewater 7
Filtration
Barnstead water purification products offer both
depth (nominal) and membrane (absolute) filters.
Depth filters are most commonly used as a pretreatment and are
manufactured by winding fibers around hollow and slotted tubes. As
water passes through the wound fiber matrix toward the center tube
particles are retained on the fibers. Traditionally this type of filter
removes most of the impurities above the rated pore size of the filter.
Most often these filters are rated to remove larger particles (> 1 um)
to protect the technologies that follow.
Membrane filters are often termed absolute, meaning that they are
designed to remove all particles above the rated pore size of the filter.
These filters use a membrane, (in flat sheet or hollow fiber form), and
are most often used at the end of a system to remove bacteria or other
particles that are not removed by the preceding technologies.
Traditionally membrane filters in laboratory water systems have a
rated pore size below 0.45 um, most often 0.2 um.
Benefits
e Efficient operation
e Maintenance is change out only
Limitations
e Clogging
e Will not remove organics, nucleases, pyrogens, dissolved gases or
dissolved inorganics
Systems that utilize this technology
e Thermo Scientific Barnstead GenPure, MicroPure, E-Pure,
LabTower EDI, Smart2Pure, Pacific TII, LabTower TII water
purification systems
Ultrafiltration (UF)
In water purification, ultrafiltration is used to
remove pyrogens (bacterial endotoxins) and nucleases,
which is critical for tissue culture, cell culture and
media preparation.
Ultrafilters use size exclusion to remove particles and macromolecules.
By design, ultrafilters operate similar to reverse osmosis membranes;
particles are captured on the surface of the membranes and are
flushed from the membrane via a reject stream. Ultrafilters are
used at the end of systems ensuring the near total removal of
macromolecular impurities like pyrogens, nucleases and particulates.
z wall
Pe Pgs
Final Filter
Ultrafilter
Benefits
e Effectively removes molecules (pyrogens, nucleases,
microorganisms, particulates) above their rated size
e Long life
e Helps to remove pyrogens and nucleases
Limitations
e Will not remove dissolved inorganics, dissolved gases,
and organics
Systems that utilize this technology
e Barnstead GenPure, MicroPure, and Smart2Pure water
purification systems
speaking the Language of Lab Water
Reverse Osmosis
Reverse osmosis is the most economical method of
removing up to 99% of feed water contaminants. Pressure
To understand reverse osmosis you must first understand osmosis.
During natural osmosis, water flows from a less concentrated solution
through a semipermeable membrane to a more concentrated solution until
concentration and pressure on both sides of the membrane
are equal.
In water purification systems, external pressure is applied to the more
concentrated (feed water) side of the membrane to reverse the natural
osmotic flow. This forces the feed water through the semipermeable
membrane. The impurities are deposited on the membrane surface and sent
to drain and the water that passes through the membrane as product water XU
is, for the most part, free of impurities.
Saline
Solution
3
Semipermeable Membrane To Drain
A reverse osmosis membrane has a thin microporous surface that rejects
impurities, but allows water to pass through. The membrane rejects bacteria, Process of reverse osmosis
pyrogens and 90-95% of inorganic solids. Polyvalent ions are rejected
easier than monovalent ions. Organic solids with a molecular weight greater
than 200 Daltons are rejected by the membrane but dissolved gases are not
as effectively removed.
Reverse osmosis is a percent rejection technology. The purity of the product
water depends on the purity of the feed water. The product is typically
95-99% higher in purity than that of the feed water.
Due to the restrictive nature of the membrane, the flow rate is much slower
than other purification technologies. This slow flow rate means that all
RO systems require a storage reservoir to provide a constant supply of
RO water ready when you need it.
Benefits
e To varying degrees, removes most types of contaminants, bacteria,
pyrogens and 90-95% of inorganic ions
e Requires minimal maintenance
Limitations
e Limited flow rates through the membrane require intermediate storage
devices to meet user demand
e Does not remove dissolved gases
e Requires pretreatment to avoid damaging the membrane
> Oxidation — Chlorine
> Scaling — CaCO.
> Fouling — Organics and Colloids
> Piercing — Hard particles
Pacific RO and Lab Tower
RO water systems
Systems that utilize this technology
e Thermo Scientific Barnstead Smart2Pure, LabTower EDI, Pacific TII,
LabTower TII, Pacific RO, LabTower RO water purification systems
www.thermoscientific.com/purewater 9
Deionization
Deionization is also referred to as demineralization
or ion exchange.
The process removes ions from feed water with
the use of synthetic resins. These resins are chemically
altered to have an affinity for dissolved inorganic ions and are
divided into two classifications: cation removal resins and anion
removal resins.
Cations have a positive charge and include sodium (Na*),
calcium (Ca*?) and magnesium (Mg*). Anions have a negative
charge and include chloride (CI), sulfates (SO,"*), and
bicarbonates (HCO-). The ions are removed from the water
through a series of chemical reactions. These reactions take
place as the water passes through the ion exchange resin beds.
Cation resin contains hydrogen (H+) ions on the surface which
are exchanged for positively charged ions. Anion resin contains
hydroxide (OH’) ions on its exchange sites which are exchanged
for negatively charged ions. The final product of these two
exchanges is H* and OH", which combine to form water (H30).
Deionization is the only technology which produces the resistivity
requirement for Type 1 reagent grade water. In laboratory water
systems, cation and anion resins are most often mixed together
allowing them to achieve maximum ionic purity.
Two-bed deionization — The cation and anion resin are in
separate halves of a cartridge. In general, this method is less
effective deionizing water as compared to the mixed-bed
deionization; however, it is more tolerant of other types of
impurities.
Mixed-bed deionization — We use semi-conductor grade
mixed bed deionization resin to achieve maximum resistivity
and low TOC. Mixing the cation and anion resin drives the
deionization to completion, making it more efficient and more
effective at the removal of ions.
Benefits
e Removes dissolved inorganics ions very effectively
e Produces product water with a resistivity above 18 MQ.cm
Limitations
e Finite capacity — once all ion binding sites are occupied, ions
are no longer retained and the cartridge must be replaced
e Does not remove organics, particles, pyrogens or bacteria
Systems that utilize this technology
e Thermo Scientific Barnstead GenPure, MicroPure, E-Pure,
LabTower EDI, Smart2Pure, Pacific TII, LabTower TII, and the
Bantam water purification systems, Hose Nipple, and
B-Pure cartridges
Diagram showing how cations and
anions are exchanged on the resin.
50,000 to 300,000 O.cm 1.18 MO.cm
Two bed resin is shown on the left and
mixed bed resin in on the right.
speaking the Language of Lab Water
Purified water < 0,1yS!om
Concentrate
Cathode
Electrolyte
Contentirate
Elactratyte Concentrate Feodwater
Cation-permeable Feedwater Anion-panmeable
membrane Pemmeate from AO system, 4 = 30 pSicm mnervrane
Process of electrodeionization
Electrodeionization (EDI)
In contrast to conventional ion exchange in which resins are exhausted and must either be thrown
away or chemically regenerated, EDI utilizes an electric current for continual resin regeneration.
How EDI works Benefits
e Effectively removes ions
Several layers of ion selective membranes are positioned e Continuously regenerates automatically
between an anode and a cathode. Layered ion exchange resin
beds and concentrate chambers are alternately positioned Limitations
e Limited capacity — feed water must be of
high quality
between them.
On applying an electric voltage, water (H20) is split into H+ and e Does not remove organics, particles, pyrogens
OH- in the cell. The H+ and Na+ cations can migrate through the or bacteria
cation permeable membranes, anions through the anion
permeable membranes. Systems that utilize this technology
e Barnstead LabTower EDI water purification system
The ions migrate in the direction of the applied voltage, i.e.
anions to the positive pole (anode), cations to the negative pole
(cathode). The water ions H+ and OH- that migrate through an
ion exchange chamber displace salt ions retained by the ion
exchanger resins and so continually regenerate the resins. The
salt ions migrate through the appropriate ion selective
membranes into the concentrate chambers and are flushed out
of them by water. As all concentration chambers are flushed
through one after the other, excess H+ and OH- ions can again
combine to form H30.
www.thermoscientific.com/purewater 11
Adsorption
Adsorption uses high surface area activated
carbon to remove organics and chlorine from
feed water.
It is used as a first or second step in most water
purification systems and may be used as a final step,
in combination with ion exchange resins, to achieve ultra
low Total Organic Carbon (TOC). Organics and chlorine
adhere to the surface of the activated carbon and remain
attached to the carbon.
Mixed-bed deionization and adsorption — We use
a combination semiconductor grade mixed-bed
deionization resins and synthetic carbon in a single
cartridge to achieve maximum resistivity and low
Total Organic Carbon (TOC).
Benefits
e Removes dissolved organics and chlorine
e Long life
Limitations
e Will not remove ions and particulates
Systems that utilize this technology
e Barnstead GenPure, MicroPure, E-Pure, LabTower EDI,
Smart2Pure, Pacific TII, LabTower TII, and the Bantam
water purification systems, Hose Nipple, and B-Pure
cartridges
Selection of high quality resins used in our cartridges.
Chlorinated H20 Carbon H20 Free of Chlorine
and Some Organics
O i
R:
ó -3 ve b.
feed water with organic and chlorine contaminants come
into contact with the activated carbon in the cartridge.
The impurities adhere to the surface of the carbon,
allowing purified water to be produced.
Ultraviolet (UV) Oxidation
Photochemical oxidation with ultraviolet light eliminates trace
organics and inactivates microorganisms in feed water.
The UV lamps in our lab water systems generate light at two wavelengths,
185 and 254 nm. The light generated at 254 nm has the greatest anti-
bacterial action, reacting with their DNA, resulting in inactivation. The
combination 185/254 nm light oxidizes organic compounds, allowing for
total oxidizable carbon levels of less than 5 ppb.
Benefits
e Effective method to prevent bacterial contamination
e Qxidizes organics to produce pure water with
low TOC levels
Limitations
e Will not remove ions, colloids and particulates
Systems that utilize this technology
e Barnstead GenPure, MicroPure, LabTower EDI, Smart2Pure, Pacific TII,
Lab Tower TII water purification systems
Combination Ultraviolet Oxidation
and Ultrafiltration (UV/UF)
The use of ultraviolet oxidation and ultrafiltration technologies in
conjunction with adsorption and deionization in the same system produces
water virtually free of all impurities. These technologies have demonstrated
the ability to remove nucleases such as RNase and DNase as well as
pyrogens when challenged with known concentrations of the material.
The Type 1 systems with UV/UF options produce reagent grade water with
resistivity up to 18.2 MOQ.cm, TOC of 1-5 ppb, pyrogens <0.001 EU/mL and
no detectable RNase, DNase or DNA.
Benefits
e Removes nucleases and DNA
e Produces water with low TOC and pyrogen levels
Limitations
e Must be used in the same system
Systems that utilize this technology
e Barnstead GenPure, MicroPure, and Smart2Pure water purification
systems
www.thermoscientific.com/purewater 13
What does Type 1 water mean?
Reagent water has quantitative specifications that describe the level of purity
for the water. These specifications have been described by ASTM (American Society for
Testing and Materials) D1193, ISO (International Organization for Standardization) 3696 and
CLSI®-CLRW. (Clinical and Laboratory Standards Institute-Clinical Laboratory Reagent Water).
The most commonly used standards, ASTM D1193-6, are summarized in the tables below.
ASTM Standards for Reagent Water
Measurement (unit) Type | Type Il Type Ill
Resistivity (MO.cm) at 25°C >18 = >4
Total organic carbon (ppb) < 50 < 50 < 200
Sodium (ppb) <
Chloride (ppb) <
<5 < 10
<5 < 10
<3 < 500
Total silica (ppb) <8)
The ASTM standards are further subdivided into A, B and C.
These standards can be used in conjunction with the Type of water.
ASTM Standards for Reagent Water
Measurement (unit) O A (| C
Heterotrophic bacteria count (CFU/mL) 10/1000 10/100 1000/10
Endotoxin (units per mL) 0.25 n/a
Here are some additional definitions of the parameters they use to indicate the water’s purity.
Resistivity — the tendency
of water without ions to resist
conducting electricity.
The unit of measure is megohm-
centimeter (MQ.cm), often
shortened to MQ or “meg”. It is
generally used for high purity
water. The theoretical maximum is
18.2 MO.cm at 25°C . The higher
the ionic content — the lower the
resistivity and the lower the ionic
content — the higher the resistivity
(high resistivity is good!). In
ultrapure water systems this value
is determined using an in-line
meter. Conductivity and resistivity
measurements are inversely
related to each other.
Conductivity — the tendency
of water that contains ions
to conduct electricity.
The unit of measure is
microsiemens/centimeter (uS/cm)
or microhm/cm. The measurement
is used to measure feed water or
lower quality treated water. The
more ions present in the water, the
higher the conductivity. This is
measured by a conductivity meter.
Total Organic Carbon (TOC) -
a measure of the organic
contaminants found in water.
The unit of measure is parts per
million (ppm) or parts per billion
(ppb). Feed water can be in the
2-5 ppm range and the best high
purity water should be in the
1-5 ppb range. Measurement
of TOC is done using an in-line
system.
speaking the Language of Lab Water
Water full of ions Pure water has very
will conduct few ions, so it does not
electricity well. conduct electricity well.
Í conduct | Resistivity | Conductivity f resistivity
Conductivity and Resistivity
Electrical conductance or resistance is measured by two in-line electrodes. Electrical current moves through
water using ionic molecules as stepping stones. The fewer stepping stones, the more difficult the passage of
electricity. This causes less electrical conductance and more electrical resistance. The temperature of the water
also affects the conductivity/resistivity so readings are usually normalized to 25°C via temperature compensation.
We use resistivity to measure ion concentration in pure water. We understand water and realize that in order to
achieve Type 1 water, meeting the most stringent requirements of our customers, multiple technologies must
be used.
Speaking the Language of Lab Water
What Type of Water Do You Need?
When designing your water system, we suggest you take time to evaluate the applications and interest areas
of the lab now and in the future. Take a look at the table below to determine what type(s) of water you need.
Ultrapure Cartridge and
Application and interest areas Type 1 filter systems
General Lab Purpose
Glassware washing/rinsing O s i
General lab equipment (water baths, incubators, etc.) O i
Feed water to Type 1 systems O n oO
Chemical and biochemical reagent prep O Ea
Analytical l
High performance liquid chromatography (HPLC) ooo D
Gas chromatography (GC) ooo D
lon chromatography (IC) ooo D
Inductively coupled plasma spectroscopy (ICP) ooo D
Mass spectroscopy (MS) ooo D
Nomis ston AA — |
Total organic carbon (TOC) Cc kl Lv OO
Life Sciences :
Genomics (ex. PCR, mutagenesis) C—O OO
Proteomics (ex. crystallography, electrophoresis) C—O OOO
Immunology (ex. monoclonal antibody production, blots) ooo D
Cell and tissue culture ooo D
Drug discovery o B
www.thermoscientific.com/purewater 17
Barnstead GenPure
water purification system
What Thermo Scientific Barnstead
water systems provide
Our water systems are engineered to be used
independently or in conjunction with our other water
systems for more flexibility. Below is a summary of
our product lines for each water type.
Ultrapure (Type 1) Water
This grade of water is required for your most sensitive and
critical laboratory applications. Type 1 water can be made
pyrogen-, nuclease-, bacteria- and particulate-free. It has the
highest purity, but is also the most expensive to generate.
If your applications require different types of water, let our
experts assist with designing a water purification system
specific to your needs.
The below systems provide you with the Type 1 water
you need for your applications.
e Thermo Scientific Barnstead LabTower EDI
water purification system
e Thermo Scientific Barnstead Smart2Pure
water purification system
e Thermo Scientific Barnstead GenPure
water purification system
e Thermo Scientific Barnstead MicroPure
water purification system
e Thermo Scientific Barnstead E-Pure
water purification system
The ultrapure systems differ in their features and daily
volume output, so please see the Type 1 Section for
complete information.
Barnstead Smart2Pure
water purification system
Pure (Type 2) Water
Type 2 water is most widely used in general laboratory
applications, such as reagent preparation and glassware rinsing.
It is also commonly used to feed our Type 1 systems to create
a comprehensive water system.
The below systems provide you with the Type 2 water
you need for your applications.
e Thermo Scientific Barnstead Pacific TII
water purification system
e Thermo Scientific Barnstead LabTower TII
water purification system
e Thermo Scientific Barnstead Mega-Pure Glass Stills
water purification system
e Thermo Scientific Barnstead Classic Stills
water purification system
Reverse Osmosis (RO) Water
RO is a percent removal technology, thus the purity of the
product water is directly dependent on the quality of the feed
water. Accordingly, it can not be generally classified as a
specific “type” of water.
RO water is recommended for use in general laboratory
equipment such as the sterilizer, dishwasher and water baths.
The below systems provide you with the RO water
you need for your applications.
e Thermo Scientific Barnstead Pacific RO water systems
e Thermo Scientific Barnstead LabTower RO water systems
Barnstead Hose Nipple
Cartridge and Holder
speaking the Language of Lab Water
Barnstead GenPure xCAD Plus water purification
system, shown with two additional remote dispensers
Cartridge and Filter Systems
Cartridges are a great option for laboratories either needing point
of use polishing of pretreated water or single state treatment of
tap water.
The below cartridge and filter systems are available for
your specific application needs.
e Thermo Scientific Barnstead B-Pure water system
e Thermo Scientific Barnstead Hose nipple cartridges
e Thermo Scientific Barnstead Bantam deionizer
e Thermo Scientific Barnstead 1/2 Size B-Pure filters
Barnstead B-Pure Barnstead Bantam Deionizer
Cartridge Holder
www.thermoscientific.com/purewater 19
Pretreatment Barnstead Pacific TIl 30 L Polyethylene Barnstead GenPure xCAD Plus
water purification system Reservoir UV/UF water purification system
Ô
p
= ~ | J
Type 2 water RO reservoir
flows into water feeds
the reservoir the Barnstead-
Type 2 GenPure Type 1
Water Water
Tap water
Applications in the Lab: Cell and Tissue Culture, PCR, Media Prep and HPLC
Water Type(s) Needed: Type 1 (low organics, pyrogens and nucleases) and Type 2 water
Solution: Barnstead Pacific TII, 30 L reservoir, and Barnstead GenPure xCAD Plus UV/UF
The Watson Lab is a traditional cell and molecular biology lab, so they needed a system that is capable of producing Type 1 water free of
nucleases, pyrogens and bacteria. Our Barnstead GenPure xCAD Plus UV/UF system is perfect for their ultrapure water needs.
Our Barnstead Pacific TII, which will produce water for the general lab uses, will also serve as feed water for the GenPure xCAD Plus UV/UF.
Pretreatment Barnstead LabTower TII Barnstead GenPure Pro UV
water purification system water purification system
Ê
Tap water
LabTower TII reservoir
water feeds the
GenPure Pro
Applications in the Lab: ICP/MS, GC/MS, HPLC, Chemical and Buffer Prep
Water Type(s) Needed: Type 1 (with low organics) and Type 2 water
Barnstead LabTower TII and the Barnstead GenPure Pro UV
Solution:
The Le Lab performs analytical experiments on a daily basis. They would like to make their own buffers and reagents, so we suggested a
configuration that would give the lab both Type 1 and Type 2 water.
Our Barnstead LabTower TII converts tap water into Type 2 water, which is stored in the 100 L integrated reservoir. Water can be drawn
from the reservoir or from our Barnstead GenPure Pro UV (which has a 0.2 um on it to ensure bacteria-free water). The reservoir feeds our
Barnstead GenPure Pro system, which will deliver ultrapure (Type 1) water.
20
speaking the Language of Lab Water
Mix and Match for
Greater Flexibility
Dual Cartridge Deionizer Barnstead Mega-Pure Still with Barnstead MicroPure UV
Automatic Collection System water purification system
Purified > i Distilled water
, water flows =æ feeds the MicroPure
into the still a
Ô
| L, g | Gs r
: i - i
Tap water F |
Still water
flows into the
reservoir
Applications in the Lab: General lab use, rinsing of glass and plastic ware, media prep, HPLC
Water Type(s) Needed: Type 1 and Type 2 (distilled)
Solution: Barnstead Mega-Pure Still with Automatic Collection System and a Barnstead MicroPure UV
The Bauer Lab needed Type 1 water for their HPLC and analytical experiments (estimated to be less than 15 L a day) and distilled
water for general reagent preparation and glassware rinsing, thus our Barnstead MicroPure UV and a Barnstead Mega-Pure Still with
Automatic Collection System were recommended. A dual cartridge deionizer was also suggested as pretreatment to the still as the
lab’s tap water was especially hard.
Pretreatment Barnstead Smart2Pure UV/UF
water purification system
Tap water
Applications in the Lab: Protein purification and PCR
Water Type(s) Needed: Type 1
Solution: Barnstead Smart2Pure UV/UF
Biochemical techniques such as protein purification and PCR are important for the Simpson Lab, but they have serious space
constraints. Our Barnstead Smart2Pure UV/UF is the all-in-one solution for tap to Type 1 water. It converts tap water to ultrapure
water and has a small foot print. The UV/UF option will provide the lab with nuclease free water, perfect for their sensitive
applications.
www.thermoscientific.com/purewater 21
ultrapure
water purification systems
What sets Thermo Scientific Barnstead
water purification systems apart?
Our Barnstead water purification portfolio includes a
complete line of Type 1 systems to meet all your ultrapure
water needs. Why so many options? For you to have a
tailored system specifically for your needs. No need to
pay for technologies that you won’t use!
UV and feed water monitoring for
maximum efficiency
EDI systems with reservoir recirculation
maintains purity even between use
Quick-change cartridge design
simplifies self maintenance
All required parts and accessories ship
under one part number
Full system control at the
Thermo Scientific Barnstead
GenPure xCAD Plus remote
dispenser
q a
x
"a
www.thermoscientific.com/purewater ele)
Feed water
° TYPE 1
nermc ler 3arnsteac
ultrapure water purification system
selector guide
Select the water system that best l
fits your requirements Benefits
D @ D @
UV oxidation is necessary for the removal of organics
in the feed water, reduces organic levels to >5 ppb,
and protects against microorganisms
Ultra-low organic levels, <5 ppb
HPLC, TOC, GC/MS, ICP, ICP-MS
Cell culture, monoclonal antibody production,
Applications Ultrafiltration removes pyrogens from the feed water
electrophoresis
Nuclease and pyrogen-free applications such as UV/UF is the most common combination of technologies —
PCR, 2-D electrophoresis, cell culture, blotting used to reduce organics and remove pyrogens and nucleases
Photosensor continually checks the intensity of the UV lamp.
UV monitorin i ;
g A decrease could result in an incorrect TOC measurement result.
Feed water monitoring alerts you to fluctuations in
Technology Feed water monitoring S
Real-time monitor of the amount of organic materials
eL CTT C20 900) (DG) erior in the product water shown on the display
Dispense at the push of a button. Control from
Volumetric Dispensing 0.01-65 liters with an accurancy of <0.5%
Allows for full control of the system at the
GenPure xCAD Plus remote dispenser GenPure xCAD Plus remote dispenser
Ideal when bench space is tight. System sits under
Under-the-bench mounting the bench and out of sight.
RS-232 data printing at pre-programmed intervals Satisfies GLP guidelines, data available in print
Optimal amount of water to use daily to
sustain reasonable cartridge life Expands with your laboratory and application needs
24
Full control at
the GenPure Flexible Economical Smaller capacity Simple design,
xCAD Plus remote dispensing Type 1 water for optimal value great value
dispenser
Produces Compact unit
Type 1 and 2 with EDI producing
technology Type 1 and 2
SS oe oe os oe os se os
S
S
S
S
S
S
J J J z / J
200 L/day 200 L/day 200 L/day 15 L/day 100 L/day’ 200 L/day 150 L/day
“Applicable when using pre-treated feed water only.
www.thermoscientific.com/purewater 25
Thermo Scientific Barnstead GenPure xCAD Plus
water purification system
The Barnstead GenPure xCAD Plus system delivers ultrapure 18.2 MQ.cm water with consistent quality for
the most demanding and sensitive applications. The xCAD remote dispenser provides flexibility and control.
Molecular Biology and Microbiology
e Cell and tissue culture
e PCR, DNA sequencing
e Electrophoresis
Analytical Chemistry
e HPLC
e GC, GC-MS, ICP-MS, AA
e TOC Measurements, IC
26
All GenPure systems exceed international standards ASTM Type I, ISO 3696
Grade 1, ASTM D1193 and CLSI-CLRW.
Simultaneously dispense from up to three dispensers
e Each system ships with a single xCAD Plus remote dispenser
e For increased flexibility, add one or two more xCAD Plus dispensers
e Dispense from all three simultaneously
Integrated feed water monitoring
e Additional measuring cell monitors feed water conductivity. If the quality
of the feed water drops below the set value, a fault message will immediately
be displayed.
Online TOC measurement with UV intensity monitoring
e Real-time TOC monitoring for continual measurement of organic substances
present in the water
e Continuous monitoring of UV intensity removes the risk of false TOC values
due to diminished UV intensity
e Fault message alerts user when the UV lamp intensity is no longer sufficient
for accurate TOC measurements
UV Photo-oxidation 185/254 nm
e High performance UV assembly reliably reduces the content of
microorganisms and their metabolites
e UV oxidation also reduces organic compounds in the water to ultra-low levels
Leak detection
e İnternal leaks can be detected and an error displayed
Ready-to-use
e Feed water pressure switch, wall bracket, UV lamp, ultrapure cartridge, sterile
filter, all included in one part number
Measurement of conductivity/resistivity
e Conductivity cells are carefully calibrated prior to each measurement via
built-in reference resistance with cell constants at 0.01 cm“
e Temperature measurements are made by a platinum chip sensor with
+ 0.1°C accuracy
Quick-connect cartridge replacement
e Aquastop quick-connect capability enables cartridge replacement within
seconds even mid-operation
Exact dosing
e Electronic dosing for fully automatic volume control of 0.01-65 L with
< 2% accuracy
extreme flexibility
GLP-compliant documentation
e Real-time clock and code-protected operating system prevents unauthorized changes to system settings
e RS-232 interface with adjustable send-interval for safe data transfer of all measured data, faults, date and
time to a PC computer or log printer
e Digital microprocessor control automatically monitors and stores faults from
the last four weeks
e USP-compliant conductivity measurement with temperature compensation can be switched on or off
Quick Look Comparison
GenPure xCAD GenPure xCAD GenPure xCAD GenPure xCAD Plus GenPure xCAD Plus GenPure xCAD Plus
Plus system Plus UV system Plus UF system UV/UF system UV - TOC system UV/UF - TOC system
Inorganic and organic} Molecular biology, Molecular biology, Chemical analysis Biosciences
Applications AA, IC, ICP, trace analysis, microbiology, PCR, DNA, (trace analysis, (cell and tissue culture
PP standard buffer HPLC, ICP-MS, IC, IVF, monoclonal monoclonal antibodies, HPLC, IC, ICP-MS, media, PCR, DNA,
TOC analysis antibodies cell culture media TOC measurements monoclonal antibodies)
Resistance at 25°C,
Conductivity, uS/em 0.055 0.055
a 5
RNase, ng/ml n/a n/a n/a n/a <0.003
Ones, poli i i a
Bacteria, cFUmL | €a | a | a | a S a <1
Particles, 0.22 ym/mL | a | a | a d a S a <1
Endotoxins, EU/mL | ma | ma | <0 | <01 | ma _ | <o]
TOC monitor standard
Flow rate, L/min up to 2
Visible ultrapure water quality Non-Stop: System
Important measured values of conductivity/resistivity ready for dispensing
and TOC are easy to see during dispensing.
TC: temperature
compensation is on
18.2 MQ.cm: Resistivity of
the ultrapure water ="
— o
17.5°C: Temperature measured for
conductivity compensation e—— 1.00 L: Adjustable
volume to be
UV: UV lamp is switched on ————e dispensed
1 ppb: TOC value of the
ultrapure water
www.thermoscientific.com/purewater 27
SWIAISAS UONIYLN, 1878M aIndein
Thermo Scientific Barnstead GenPure xCAD Plus
water purification system (continued)
Our xCAD Plus remote dispenser shown left.
The GenPure system is under the bench
(not pictured) freeing up valuable bench space.
For increased flexibility, add up to two more
XCAD Plus remote dispensers.
Thermo Scientific xCAD Plus remote dispenser —
full system control in a compact design
e xCAD is short for “Extended Control and Dispenser.” The system provides more flexibility for ultrapure
water dispensing with an action radius of 32 inches (80 cm)
e Ergonomic dispensing arm provides precise volume dosing at the press of a button
e Turned, height adjusted or extended towards your vessel, you'll appreciate the flexibility of this
dispenser
e QOne-of-a-kind design provides access to all system controls at your fingertips
e Specify bench-top or wall-mount xCAD Plus dispenser for the installation option of your choice. The
small footprint of the bench-top xCAD Plus allows for more bench space while the wall-mount version
completely frees up horizontal workspace.
e Adjustable controller makes handling more practical and provides a clear view of critical settings
e In addition to flexible xCAD Plus installation options, GenPure systems can also be installed under the
bench or wall-mounted with included mounting brackets up to 2.5 m (8 ft) away from main system.
28
xCAD Dimensions
Dimensions W x D x H in (mm)
Benchtop xCAD 10.2 x 21 x 28.5 (260 x 530 x 725)
Wall mount xCAD 10.2 x 21 x 25.8 (260 x 530 x 655)
Feed water Requirements”
Potable tap water, pretreated by reverse osmosis,
SOUICE ion exchange or distillation
Feed water conductivity, pS/cm <2
TOC, ppb max 50
s 7 | Bacteria count, CFU/mL < 100
E R Turbidity, NTU <1.0
NG Complete water purification Temperature, °C 2-35
| system control via the xCAD Pressure, psi (bar) 1.4-87 (0.1-6)
C Plus remote dispenser
* Please see user manual for complete list of feed water requirements
Product Specifications
Operating pressure ; : Dimensions
ae Electrical requirements Power consumption Feed water connector WxDxH in (mm)
29-87 psi 90-240V, 50/60Hz 0.1kW 34” NPT 14.6 x 13 x 24
(2-6 bar)
GenPure xCAD
(372 x 330 x 615)
again GenPure xCAD GenPure xCAD GenPure xCAD GenPure xCAD Plus UV/UF -
Plus UV Plus UF Plus UV/UF Plus UV - TOC TOC
GenPure System*
Al systems include a wallbracket, | tener version (mE 50136152 50136150 50136151 50136153 50136146
ultrapure polisher cartridge, sterile
0.2 um filter, pressure regulator, UV with xCAD Plus
lamp and/or ultrafilter where applicable 50136165 50136170 50136167 50136169 50136171 50136172
Optional Accessories
Stainless steel DI cartridge, DI 1500
Required only when feed water does not meet feed water
requirements. Prolongs system cartridge life. For new 02.1500 02.1500 02.1500 02.1500 02.1500 02.1500
installations, 04.1690 is a required hose kit to adapt
cartridge to system.
XCAD Plus Remote Dispenser bern version version 50136494 50136494 50136494 50136494 Sogea 50136494
Additional remote dispenser for Er gg PENVEN
flexibility. Up to 2 additional dispensers
sane E cide Geni 50136505 50136505 50136505 50136505 50136505 50136505
Disinfection cartridge
Reusable cartridge needed to clean the water 09.2201 09.2201 09.2201 09.2201 09.2201 09.2201
purification system.
Printer
(hilizas HO-939 interacetoreate 120V, 50/60Hz AY1137X1 AY1137X1 AY1137X1 patton O aa AY1137X1
documentation of all measured values
and faults with date and time in 230V, 50Hz 09.2207 09.2207 09.2207 09.2207 09.2207 09.2207
compliance with GLP guidelines
Qualification documentation (IQ0Q) I0QDOCE50133918 | I0QDOCE50133918 | I0QDOCE50133918 | IOQDOCE50133918 | IOQDOCES50133918 |IOQDOCE50133918
Storage reservoir, 30 L, to feed system
Polyethylene tank, opaque to light
23.5 x 14.9 in (598 x 380 mm), H x W 06.5038 06.5038 06.5038 06.5038 06.5038 06.5038
Wall mount accessory is 06.5015
Storage reservoir, 60 L, to feed system
Polyethylene tank, opaque to light
35.9 x 14.9 in (912 x 380 mm), Hx W 06.5068 06.5068 06.5068 06.5068 06.5068 06.5068
Wall mount accessory is 06.5016
Replacement Consumables
Flow rate
up to 2 L/min
System Options
=
=
=
Q)
O
=
=
cD
jes)
mF
(gP)
s<
-U
=
-x
=h
(qp)
jas)
=
(æ)
=
WM
<
oe]
mF
(gP)
=
O)
Uitrapure polisher cartridge 09.2005
Sterile filter, 0.2 um 09.1003
Uitrafitter 50133980
UV lamp 09.2002
Europe/Asia Pacific 09.2202 09.2202 09.2202 09.2202 09.2202 09.2202
Cleaning solution North America/
CMX25 CMX25 CMX25 CMX25 CMX25 CMX25
www.thermoscientific.com/purewater * G C E 29
Thermo Scientific Barnstead GenPure Pro
water purification system
The Barnstead GenPure Pro system delivers ultrapure 18.2 MQ.cm water with consistent quality. Suitable for the most
demanding laboratory applications, this ultrapure water system will deliver water from a small footprint. The GenPure Pro
system can be used on a laboratory bench or on a wall. The new flexible dispenser offers maximum freedom while
dispensing ultrapure water up to 24 inches (60 cm) away from the unit.
Molecular Biology and Microbiology
e Cell and tissue culture
e PCR, DNA sequencing
e Electrophoresis
Analytical Chemistry
e HPLC
e GC, GC-MS, ICP-MS, AA
e TOC Measurements, IC
30
All GenPure systems exceed international standards ASTM Type |, ISO 3696
Grade 1, ASTM D 1193 and CLSI.
Dispensing for a variety of tasks
e New flexible dispenser offers a radius of 24 inches (60 cm) from the system for
filling larger vessels or glassware washing
Leak detection
e Internal leaks can be detected and an error displayed
Integrated feed water monitoring
e An additional measuring cell monitors feed water conductivity. Any exceeding of
the limiting value is immediately displayed to maximize cartridge life.
Online TOC measurement with UV intensity monitoring
e Real-time TOC monitoring for continual measurement of organic substances
present in the water
e Continuous monitoring of UV intensity removes the risk of false TOC values due
to diminished UV intensity
e Fault message alerts user when the UV lamp intensity is no longer sufficient for
accurate TOC measurements
UV Photo-oxidation 185/254 nm
e High performance UV assembly reliably reduces the content of microorganisms
and their metabolites
e UV oxidation also reduces organic compounds in the water to ultra-low levels
Ready-to-use
e Feed water pressure switch, wall bracket, UV lamp, ultrapure cartridge, sterile
filter, all included in one part number
e Leak detection standard and will alert user to leaks
Measurement of conductivity/resistivity
e Conductivity cells are carefully calibrated prior to each measurement via built-in
reference resistance with cell constants at 0.01 cm"
e Temperature measurements are made by a platinum chip sensor with
+ 0.1°C accuracy
Quick-connect cartridge replacement
e Aquastop quick-connect capability enables cartridge replacement within
seconds even mid-operation
Exact dosing
e High precision POM draw-off valve for dispensing with sterile filter
e Electronic dosing for fully automatic volume control of 0.01-65.0 L with
< 2% accuracy
Push button simplicity for easy dispensing
GLP-compliant documentation
e Real-time clock and code-protected operating system prevents unauthorized
changes to system settings
e RS-232 interface with adjustable send interval for safe data transfer of all
measured data, faults, date and time to a PC computer or log printer
e Digital microprocessor contro! automatically monitors and stores faults from the
last four weeks
e USP-compliant conductivity measurement with temperature compensation can
be switched on or off
Tilting Control Panels for Easy Viewing
e Ergonomically designed controller tilts for ease-of-use and better visibility
e |lluminated four-line alpha-numeric display
Quick Look Comparison
GenPure Pro GenPure Pro UV GenPure Pro UF GenPure Pro UV/UF GenPure Pro GenPure Pro
system system system system UV - TOC UV/UF - TOC
system system
Biosciences
(cell and tissue culture
media, PCR, DNA,
monoclonal antibodies)
Chemical analysis
(trace analysis,
HPLC, IC, ICP-MS,
TOC measurements)
Inorganic and
organic trace analysis,
HPLC, ICP-MS, IC,
TOC analysis
Molecular biology,
PCR, DNA,
monoclonal antibodies,
cell culture media
Microbiology,
IVF, monoclonal
antibodies
AA, IC, ICP,
Applications standard buffer
Resistance at 25°C,
RNase, ng/ml n/a n/a n/a n/a <0.003
DNase, pg/ul n/a n/a n/a n/a <0.4
Particles,
flexible dispensing
OTE > UU monitorinc
www.thermoscientific.com/purewater 31
=
=
=
Q)
O
=
-x
(gp)
pa)
J
tq)
=F
-U
=
-x
=h
(qp)
jas)
=g
(æ)
=
WM
<
O)
(a
(gP)
=
O)
32
Feed Water Requirements*
Source Potable tap water, pretreated by reverse osmosis,
ion exchange or distillation
Feed water conductivity, pS/cm <2
TOC, ppb max 50
Bacteria count, CFU/mL < 100
Turbidity, NTU =< 1.0
Temperature, °C 2-35
Pressure, psi (bar) 1.4-87 (0.1-6)
Please see user manual for complete list of feed water requirements
Product Specifications
Operating pressure 7 3 5 Dimensions
min/max Electrical requirements Power consumption Feed water connector Wx D x H in (mm)
29-87 psi i 18.6 x 13 x 24.2
up to 2 L/min (2-6 bar) 90-240V, 50/60Hz 0.1kW 3/4" NPT (472 x 330 x 615)
GenPure Pro ets Pro HUS Pro GenPure Pro GenPure Pro GenPure Pro
UV/UF UV - TOC UV/UF - TOC
GenPure Pro System*
Alsystems inciude a wall bracket, uirapure Posner 50131952 50131954 50131950 50131948 50131922
cartridge, sterile 0.2 um filter, pressure regulator,
and UV lamp and/or ultrafilter where applicable
Optional Accessories
Stainless steel DI cartridge, DI 1500
Required only when feed water does not meet feed
water requirements. Prolongs system cartridge life. 02.1500 02.1500 02.1500 02.1500 02.1500 02.1500
For new installations, 04.1690 is a required hose kit
to adapt cartridge to system.
Printer
safe documentation of all
measured values and faults
compliance with GLP guidelines
Qualification Documentation (IQ0Q) I0QDOCE50133919 | IOQDOCES01 33919 | IOQDOCESN133919 | IOQDOCES01 33919 | |OQDOCES013391 9 | IOQDOCES0133919
Storage reservoir, 30 L, to feed system
Polyethylene tank, opaque to light.
23.5 x 14.9 in (598 x 380 mm), H x W. 06.5038 06.5038 06.5038 06.5038 06.5038 06.5038
Wall mount accessory is 06.5015
Storage reservoir, 60 L, to feed system
Polyethylene tank, opaque to light.
35.9 x 14.9 in (912 x 380 mm), H x W. 06.5068 06.5068 06.5068 06.5068 06.5068 06.5068
Wall mount accessory is 06.5016
Disinfection cartridge
Reusable cartridge needed to clean the water 09.2201 09.2201 09.2201 09.2201 09.2201 09.2201
purification system.
Replacement Consumables
Ultrapure polisher cartridge 09.2005
Cleaning solution North Pe
CMX25 CMX25 CMX25 CMX25 CMX25 CMX25
'@ CE
Flow rate
System Options
www.thermoscientific.com/purewater 33
=
=F
—
jab)
O
=
FER
(qp)
ab)
F
iq)
=
-U
==
=
=
(aP)
o
=n
(æ)
=
op)
<
(e)
mF
cD
=
1p)
Thermo Scientific Barnstead GenPure
water purification system
The Barnstead GenPure system delivers ultrapure 18.2 MQ.cm water with consistent quality
for the most demanding and sensitive applications.
Molecular Biology and Microbiology
e Cell and tissue culture
e PCR, DNA sequencing
e Electrophoresis
Analytical Chemistry
e HPLC
e GC, GC-MS, ICP-MS, AA
e TOC Measurements, IC
34
All GenPure systems exceed international standard ASTM Type I, ISO 3696
Grade 1, ASTM D1193 and CLSI-CLRW
Integrated feed water monitoring
e An additional measuring cell monitors feed water conductivity. Any exceeding of
the limiting value is immediately displayed maximizing cartridge life
Online TOC measurement with UV intensity monitoring
e Real-time TOC monitoring for continual measurement of organic substances
present in the water
e Continuous monitoring of UV intensity removes the risk of false TOC values due
to diminished UV intensity
e Fault message alerts user when the UV lamp intensity is no longer sufficient for
accurate TOC measurements
UV Photo-oxidation 185/254 nm
e High performance UV assembly reliably reduces the content of microorganisms
and their metabolites
e UV oxidation also reduces organic compounds in the water to ultra-low levels
Ready-to-use
e Feed water pressure switch, wall bracket, UV lamp, ultrapure cartridge, sterile
filter, all included with one part number
Measurement of conductivity/resistivity
e Conductivity cells are carefully calibrated prior to each measurement via built-in
reference resistance with cell constants at 0.01 cm”
e Temperature measurements are made by a platinum chip sensor with
+ 0.1°C accuracy
Quick-connect cartridge replacement
e Aquastop quick-connect capability enables cartridge replacement within
seconds even mid-operation
GLP-compliant documentation
e Real-time clock and code-protected operating system prevents unauthorized
changes to system settings
RS-232 interface with adjustable send-interval for safe data transfer of all
measured data, faults, date and time to a PC computer or log printer
Digital microprocessor control automatically monitors and stores faults from the
last four weeks
USP-compliant conductivity measurement with temperature compensation can
be switched on or off
Tilting control panels for easy viewing
e Ergonomically designed controller tilts for optimal key pressing and easy
readability
e |lluminated four-line alpha-numeric display
|_|
ONTIC ATIO“
A
A
with options to meet your needs
Quick Look Comparison
GenPure GenPure UV GenPure UF GenPure UV/UF GenPure UV - TOC GenPure UV/UF - TOC
system system system system system system
Inorganic and organic Microbiolo Molecular biology, Chemical analysis Biosciences
Avolications AA, IC, ICP, trace analysis, WE mondel fae PCR, DNA, (trace analysis, (cell and tissue culture
pp standard buffer | HPLC, ICP-MS, IC, beani monoclonal antibodies, | HPLC, IC, ICP-MS, media, PCR, DNA,
TOC analysis cell culture media TOC measurements) monoclonal antibodies)
Resistance at 25°C,
Flow rate, L/min Up to 2 Up to 2 Up to 2 Up to 2 Up to 2 Up to 2
=
=
=
Q)
<2)
=
=“
CD
Q
mF
(gP)
sx
-U
=
=
=
(qp)
jes)
=g
(æ)
=
WM
<
O)
mF
(gP)
=
Sp)
www.thermoscientific.com/purewater 35
Thermo Scientific Barnstead GenPure
water purification system (continued)
= <a e a!
UV intensity monitoring provides superb reliability
Easy cartridge replacement
Feed Water Requirements*
Source Potable tap water, pretreated by reverse osmosis,
ion exchange or distillation
Feed water conductivity, pS/cm <2
TOC, ppb max 50
Bacteria count, CFU/mL < 100
Turbidity, NTU <10
Temperature, °C 2-35
Pressure, psi (bar) 1.4-87 (0.1-6)
* Please see user manual for complete list of feed water requirements
Product Specifications
OUE Operating pressure Electrical Power Feed water Dimensions
min/max requirements consumption connector W x D x H in (mm)
. 29-87 psi i ayn 14.6 x 13 x 24.2
up to 2 L/min (2-6 bar) 90-240V, 50/60Hz 0.1kW 4” NPT (372 x 330 x 615)
GenPure a he ee GenPure GenPure GenPure
system Options UV/UF UV-TOC UV/UF - TOC
GenPure system*
AI SISIEMs MO UCG a Wal Diacsel Wap ure DOs: e 50131243 50131235 50131217 50131229 50131256
cartridge, sterile 0.2 um filter, pressure regulator, UV
lamp and/or ultrafilter where applicable
Optional Accessories
Stainless steel DI cartridge, DI 1500
Required only when feed water does not meet feed
water requirements. Prolongs system cartridge life. 02.1500 02.1500 02.1500 02.1500 02.1500 02.1500
For new installations, 04.1690 is a required hose kit
to adapt cartridge to system.
Printer
Utilizes RS-239 interface tor eate 120V, 50/60Hz AY1137X1 AY1137X1 AY1137X1 AY1137X1 AY1137X1 AY1137X1
documentation of all measured
values and faults with date and time) oaqy sou 09.2207 09.2207 09.2207 09.2207 09.2207 09.2207
in compliance with GLP-guidelines
Qualification documentation (IQ0Q) I0QDOCE50133917 | IOQDOCE50133917 | I0QDO0CE50133917 | I0OQDOCE50133917 | I0QDOCE50133917 | I0QDOCE50133917
Disinfection cartridge
Reusable cartridge needed to clean the water 09.2201 09.2201 09.2201 09.2201 09.2201 09.2201
purification system.
Storage reservoir, 30 L, to feed system
Polyethylene tank, opaque to light.
23.5 x 14.9 in (598 x 380 mm), H x W. 06.5038 06.5038 06.5038 06.5038 06.5038 06.5038
Wall mount accessory is 06.5015
Storage reservoir, 60 L, to feed system
Polyethylene tank, opaque to light.
35.9 x 14.9 in (912 x 380 mm), H x W. 06.5068 06.5068 06.5068 06.5068 06.5068 06.5068
Wall mount accessory is 06.5016
Replacement Consumables
Ultrapure polisher cartridge 09.2005 09.2005 09.2005 09.2005 09.2005 09.2005
Sterile filter, 0.2 pm 09.1003 09.1003 09.1003 09.1003 09.1003 09.1003
Ultrafilter Se Oe 50133980 50133980 pa 50133980
UV lamp Ma | 092002 | 09.2002 | 2002 09.2002 | 2002 09.2002 | 2002 09.2002
Europe/ 09.2202 09.2202 09.2202 09.2202 09.2202 09.2202
; , Asia Pacific
Cleaning solution Norih Americal
CMX25 CMX25 CMX25 CMX25 CMX25 CMX25
"@ CE
www.thermoscientific.com/purewater 37
=
—
—
ee)
<2)
=
mm
(ap)
pa)
F
CD
—
-U
=
-x
=
(ap)
o
=
=)
=.
Tp)
<
Sp)
"F
tq)
=
O)
Thermo Scientific Barnstead MicroPure
water purification system
The Barnstead MicroPure system was designed for laboratories that require up to 15 L/day of ultrapure water such as
HPLC or other instrumental analyses, sample preparation, glassware rinsing, or molecular biology work in which
endotoxins and/or nucleases would interfere.
Molecular Biology and Microbiology
e Cell and tissue culture
e PCR, DNA sequencing
e Electrophoresis
Analytical Chemistry
e HPLC
e GC, GC-MS, ICP-MS, AA
e TOC Measurements, IC
compact system
Smart features
e Backlit display tilts for easy viewing
e Variable speed dispensing
e Optional integrated 6 L feed water reservoir so you can place the system
without direct access to a water line
Monitor feed water quality
e Good feed water quality leads to consistently ultrapure water and a longer
cartridge service life to maximize cartridge life
Smart design
e Recirculation pump prevents bacterial growth during standstill and allows for
constant monitoring of all system functions, allowing for the immediate display
of fault messages if a problem is detected
e Systems ship fully equipped with pressure reducer, ultrapure cartridge and
0.2 um sterile filter
Superior filters
e Ultrafilter is flushed automatically to assure the highest retention of endotoxins
and nucleases, which produces a long two year lifetime
e Validated 0.2 um final filter with folded membrane can be sterilized up to
5 times
UV Photo-oxidation 185/254 nm
e High performance UV assembly reliably reduces the content of microorganisms
and their metabolites
e UV oxidation also reduces organic compounds in the water to ultra-low levels
for small ultrapure water demands
38
Quick Look Comparison
Applications
Resistance at 25°C, MQ.cm
Conductivity, pS/cm
TOC, ppb
RNase, ng/ml
DNase, pg/ul
Bacteria, CFU/mL
Particles, 0.22 pm/mL
Endotoxines, EU/mL
Flow rate, L/min
Instrumental analytical High-sensitivity instrumental
methods such as analytical methods, such as
AAS, IC, ICP HPLC, ICP-MS, TOC-analyses
Molecular biology, cell culture
monoclonal antibodies
18.2 MQ.cm water
in a compact system
a/purewater
Microbiology, molecular
’ | biology, PCR, DNA, monoclonal
antibodies, cell culture media
18.2
0.055
IES
<0.003
<0.4
z]
<1
<0.001
39
SWƏJSÁS UORLIIJNd 1878M ƏMNdELIN
Thermo Scientific Barnstead MicroPure
water purification system (continued)
Dispense water which allows for drop by One, two, three... The MicroPure-ST series includes an
drop or quick dispensing optional 6 L feed water reservoir for
Rapid cartridge change with
pretreated water storage.
Aquastop quick-connect design
40
Feed Water Requirements*
Source Potable tap water pretreated by reverse osmosis,
ion exchange or distillation
Feed water conductivity, pS/cm <5)
TOC, ppb max 50
Turbidity, NTU <0
Temperature, °C 2-35
Pressure, psi (bar) 1.4-87 (0.1-6)
* Please see user manual for complete list of feed water requirements
Product Specifications
Dimensions Dimensions
MicroPure (no reservoir) MicroPure-ST
WxDxH in (mm) WxDxH in (mm)
Operating pressure Electrical Power Feed water
Flow rate : ‘ :
min/max requirements consumption connector
: 29-87 psi i 12 x 11.8 x 21.5 12 x 15.7 x 21.5
up to 1.5 L/min (2-6 bar) 90-240 V, 50/60Hz 0.06kW 3/4" NPT (305 x 300 x 545) (305 x 400 x 545)
System Options MicroPure MicroPure UV MicroPure UF MicroPure UV/UF
MicroPure system*
All systems include an ultrapure polisher cartridge, sterile 0.2 um filter, 50132366 50132373 50132368 50132370
pressure regulator, UV lamp and/or ultrafilter where applicable.
Stainless steel DI cartridge, DI 1500
Required only when feed water does not meet feed water requirements. 02.1500 02.1500 02.1500 02.1500
Prolongs system cartridge life for line-fed systems. For new installations,
04.1690 is a required hose kit to adapt cartridge to system.
Optional Accessories
Wall mounting bracket 09.2212 09.2212 09.2212 09.2212
Qualification Documentation (IQ0Q) I0QD0OCE50133913 | IOQDOCE50133913 | IOQDOCE50133913 | IOQDOCE50133913
Disinfection cartridge
Reusable cartridge needed to clean the water purification system. 09.1102 09.1102 09.1102 09.1102
Only for line-fed units.
MicroPure MicroPure UV MicroPure UF MicroPure UV/UF
with storage tank with storage tank with storage tank with storage tank
System Options
MicroPure with Storage tank system*
All systems include a 6L internal reservoir, ultrapure polisher cartridge, sterile 50132367 50132374 50132369 50132372
0.2 um filter, pressure regulator, UV lamp and/or ultrafilter where applicable
Optional Accessories
Stainless steel DI cartridge, DI 1500
Required only when feed water does not meet feed water requirements. 02.1500 02.1500 02.1500 02.1500
Prolongs system cartridge life for line-fed systems. For new installations,
04.1690 is a required hose kit to adapt cartridge to system.
Wall mounting bracket 09.2212 09.2212 09.2212 09.2212
Qualification Documentation (IQ0Q) I0QD0OCE50133914 | IOQDOCE50133914 | IOQDOCE50133914 | IOQDOCE50133914
Replacement Consumables for MicroPure systems and MicroPure with Storage Yank System
Ultrapure polisher cartridge 09.1006
Sterile filter, 0.2 ym 09.1003
Ultrafilter 50133981
Europe/Asia Pacific 09.2202 09.2202 09.2202 09.2202
Cleaning solution :
North America/
Latin America CMX25 CMX25 CMX25 CMX25
'@ CE
www.thermoscientific.com/purewater 41
=
—
—
ee)
<2)
=
-x
(ap)
Q
g
CD
=
-U
=
=
=
(ap)
pa)
fom
Q
=)
Tp)
<
Sp)
"F
tq?)
=
O)
Thermo Scientific Barnstead E-Pure
water purification system
The Barnstead E-Pure economically produces Type 1 water with low operating costs.
Large cartridges provide longer cartridge life and an impressive system flow rate.
Molecular Biology and Microbiology
e Cell culture
e Buffer preparation
e Electrophoresis
42
Product Features
Resistivities up to 18.2 MQ.cm and TOC levels below 10 ppb
Virgin polypropylene water pathways prevent recontamination
e Recirculation pump continuously recirculates water throughout the entire
system to maintain water purity and reduce the quantity of waste water
required for rinse-up
e Wall-mountable and completely assembled for easy installation
Quarter turn quick release canisters allow for easy cartridge replacement
0.2 um absolute final filter removes bacteria and particulates protecting the
integrity of your results
Digital resistivity meter is automatically temperature compensated to 25°C,
preventing fluctuating readings due to temperature changes
High-capacity cartridges provide low operating costs
Product Accessories
Remote dispenser
e Recirculates water through to tip of dispenser and includes a 0.2 um final filter
e Delivers water up to 8 ft (2.4 m) from the system
e Ships with a mounting bracket for increased flexibility in choosing a
mounting location
Low pressure pump protector
e |f you are feeding your E-Pure system from a pressurized feed line, it is to your
advantage to ensure that the pump is fully protected with the use of the low
pressure pump protector
e Interrupts power if pressurized feed water line pressure falls below 5 psig
(0.35 kg/cm?)
e Includes 6 ft (1.8 m) cord which plugs directly into the E-Pure
e Complete with 1/4 inch NPT “T” to install in your feed line
Low water level pump protector
e |f feeding your E-Pure from a storage reservoir, it is recommended that a low
water pump protector be added to the E-Pure system. This will ensure that the
pump is protected in the event the reservoir does not have a sufficient quantity
of water to satisfy the requirements of the system.
e Adaptable to most storage reservoirs, providing a 1/2 inch NPT connection is
available. Includes 6 ft (1.8 m) cord which plugs directly into the E-Pure
Quick Look Comparison
Resistivity at 25°C, MQ.cm 18.2
TOC, ppb <10
Bacteria, CFU/mL <1
Flow rate, L/min 2
Feed Water Requirements”
Depending on the cartridge pack chosen — potable tap water, or
water treated by reverse osmosis, ion exchange or distillation
4-49 (40-120)
gravity to 100
Source
Temperature, °C (°F)
Pressure, psig max
* Please see user manual for complete list of feed water requirements
Product Specifications
Overall dimensions W x H x D Feed water connector
29 x 28 x 7.5 in (73.7 x 71.1 x 19.1 mm) 1/4 in NPTF
35 X 28 x 7.5 in (88.9 x 71.1 x 19.1 mm) 1/4 in NPTF
E-Pure 3-holder
E-Pure 4-holder
E-Pure systems* 120V 2 L/min D4631
Ships with wall bracket and cartridge o-rings © 24W | min D4632-33
D5029
D0835 Pretreatment (1)
D5027 Ultrapure (2)
Required Accessories
Tap feed
Tap feed,
; i Organic free
Cartridge kits
Choose the cartridge pack according to your
feed water and need for organic free water
Pretreated feed
D5022
D0836 Macropure (
D5027 Ultrapure (1
Pretreated feed,
Organic free
)
{
)
D5021 Organic Free (1)
D3750
0.2 um final filter
Optional Accessories
Remote dispenser
Recirculates water through to tip of dispenser and includes a 0.2 um final filter.
Delivers water up to 8 ft (2.4 m) from the system. Ships with a mounting bracket.
Low pressure pump protector
Alerts the E-Pure of an inadequate feed water condition in a pressurized feed line
D8952
D2706
D50223
www.thermoscientific.com/purewater
Low water level pump protector
Alerts the E-Pure of an inadequate feed water condition when fed from a reservoir
Replacement Consumables
Cleaning cartridges
Set of three.
Inlet water temperature
40-120°F/4-49°C
40-120°F /4-49°C
D4641
D4642-33
D5028
D0835 Pretreatment (1)
D0803 High Capacity (1)
D5027 Ultrapure (2)
D5023
D0836 Macropure (1)
D0803 High Capacity (1)
D5027 Ultrapure (1)
D5021 Organic Free (1)
D50227
D0835 Pretreatment (1)
D0809 Ultrapure (1)
D5027 Ultrapure (2)
D50228
D0836 Macropure (1
D0809 Ultrapure (1)
D5027 Ultrapure (1)
D5021 Organic Free (1)
D3750
(1)
D8952
D2706
D0603
D0606
D50223
'®@ CE
43
SWƏJSÁS UOREIIJUNd 1978M ANdLNIN
Thermo Scientific Barnstead LabTower EDI
water purification system
The Barnstead LabTower EDI is an integrated system combining purification with EDI technology and storage in one,
as well as producing both Type 1 and Type 2 water. Stock high purity water safely and conveniently!
Ultrapure water which exceeds ASTM Type I standards, with a resistivity of
18.2 MOQ.cm and TOC 1-5 ppb with optional UV lamp.
High purity water ASTM Type II water, with resistivity of 15-10 MQ.cm, is ideal for
daily needs of 100 to 500 L.
Two systems in one
e Unique systems with pretreatment plus polisher to produce both Type 1 and
Type 2 water
e Type 2 water is stored in the integrated 100 L high purity water reservoir
e Water system sits on top of the reservoir saving critical bench space
Ready-to-use
e Feed water pressure switch, all filters and cartridges, sterile filter, all in one
package
Two ways to draw water
e Dispense ultrapure water directly from the system via the dispenser with sterile
filter. The water quality is measured immediately prior to the dispensing point.
e Type 2 water is accessible from the reservoir, which is an ideal supply for lab
equipment such as autoclaves
Performance for your application feeds
e High performance reverse osmosis module is paired with an EDI module and
polisher cartridge
e Two systems to choose from with capacities of 15 and 30 L per hour
Type 1 Water Applications
e Cell and tissue culture
e PCR, DNA sequencing
e Electrophoresis, TOC Measurements, IC
Quick Look Comparison
e HPLP, GC-MS, ICP-MS, AA
LabTower EDI 15 LabTower EDI 30
system system
Type 2 Water Applications Type 1 Water
e Rinsing lab glassware Resistivity at 25°C, MO.cm 18.2
saurane Conductivity, pS/cm 0.055
ultrapure water systems TOS; ppb DE l
e Preparing and diluting buffers, iiai — — —
pees ances Bacterial content in CFU/mL <1
Particles, 0.22 pm/mL <1
Flow rate at dispenser, L/min 1.5
Type 2 Water
Pure water production at 15°C L/hr 30
Resistivity at 25°C 15-10
Conductivity 0.067-0.1
“Specification only applicable if system has optional ultrafilter attached.
J4
Compact, stylish, mobile
e Free-standing unit takes up no bench space
e Easily relocated with bottom-mounted rollers
Safe operation
e Microprocessor control for automatic operation
e Continuous monitoring of all critical parameters
e Recirculation pump protects purified water from bacterial
growth during standstill
GLP-compliant documentation
e Real-time clock and code-protected operating system
prevents unauthorized changes to system settings
e RS-232 interface with adjustable send-interval for safe data
transfer of all measured data, faults, date and time to a PC
computer or log printer
Digital microprocessor contro! automatically monitors and
stores faults from the last four weeks
USP-compliant conductivity measurement with temperature
compensation that can be switched on or off
100 L Integrated polyethylene reservoir safely stores
Type 2 water
e Automatic water recirculation in the reservoir moves water
across a special polisher module ensuring fresh Type 2
water on demand
High-purity water reservoir outlet for convenient drainage
Efficient cleaning and disinfection enhanced by conical
bottom design for completely emptying reservoir
Integrated reservoir provides 100 L of purified water
storage
Sterile vent filter and reservoir overflow prevents internal
contamination by microorganisms from the surrounding air
Optional CO, adsorber prevents CO. adsorption into the
water, which would reduce cartridge life.
Highly visible reservoir volume display on LabTower
controller
e Customize volume stored in the reservoir via the controller
www.thermos ie
‘with EDI te
chnology
Quickly view reservoir level
(volume in %) with highly-
visible continuous monitor
G 8 +t AdAL
SWA}SAS UOHeINUN, JaVe\\ sundenjy
Thermo Scientific Barnstead LabTower EDI
water purification system (continued)
Purified water < 0. lyon
Cation-permeahle
Feedwater
membrana Permeate from RÒ item, 4 = 30 plom
Technologies that keep
you one step ahead
e Constant high efficiency of the ion exchange layer bed
produces consistently high quality water
e No regeneration chemicals required and no disposal of
cartridges, making this technology friendly for the environment
e No exchange of spent resins or cartridges saves cost
e High-purity water when you need it with no wait time
ip
Optional hand dispenser
46
Electrodeionization, EDI, unites two proven
technologies for producing ultrapure water:
Electrodialysis and ion exchange. In contrast to
conventional ion exchange in which resins must be
either chemically regenerated or the cartridge
discarded, EDI utilizes an electric current for
continual resin regeneration.
How EDI works
Several layers of ion selective membranes are situated between
an anode and a cathode. Layered ion exchange resin beds and
concentrate chambers are alternately positioned between them.
On applying an electric voltage, water (H20) is split into H* and
OH in the cell.
The H* and Na* cations can migrate through the cation
permeable membranes, anions through the anion permeable
membranes.
The ions migrate in the direction of the applied voltage, i.e.
anions to the positive pole (anode), cations to the negative pole
(cathode). The water ions that migrate through an ion exchange
chamber displace salt ions retained by the ion exchange resins
and so continually regenerate the resins.
The salt ions migrate through the appropriate ion selective
membranes into the concentrate chambers and are flushed out
by water. As all concentration chambers are flushed, excess H+
and OH" ions can again combine to form H30.
Feed Water Requirements* 2
Source Potable tap water softened or hardness stabilized "D
Conductivity, pS/cm <1500 LL
Colloid index <3 =
pH-range 4-11
Temperature, °C 2-35 Ss
Pressure, psi (bar) 1.4-87 (2-6)
* Please see user manual for complete list of feed water requirements
Product Specifications
Operating pressure - : 5 Dimensions
anak Electrical requirements Power consumption Feed water connector Wx Dx H in (mm)
29-87 psi 17.7 x 22.8 x 59.1
(2-6 bar) (450 x 580 x 1500)
Flow rate
up to 1.5 L/min 90-240V, 50/60Hz 0.25 kW 3/4" NPT
System Options LabTower EDI 15 LabTower EDI 30
LabTower EDI system*
All systems include an ultrapure polisher cartridge, RO membrane, RO pretreatment filters (5 um filter and hardness 50132395 50132396
stabilizer), EDI module, UV lamp, sterile 0.2 um filter, 10 inch 1 um filter (reservoir outlet) and pressure regulator
Required Accessories
Sterile overflow for reservoir
Prevents the penetration of bacteria and other microorganisms aooaa Ha
CO, adsorber + sterile filter, 0.2 m
Combination sterile filter with CO. adsorber will prevent CO. from entering the tank, saving cartridge life go oa Tee
=
—
—
pa)
<2)
=
-x
(ap)
pa)
F
CD
-x
-U
=
=
=e
(ap)
o
=g
(æ)
—
Sp)
<
(op)
(a
tq)
=
op)
Mix Multi Mini water softener
120V, 50/60Hz 50129892 50129892
Required if feed water silt density index (SDI) is greater than 3. Also required
for purchase with a softener is the softener salt, hardness detection kit, and the 240V 50130297 50130297
5 um filter with carbon.
Softener salt North America/Latin America 50129893 50129893
Required for use with the water softener Europe and Asia Pacific 06.2000 06.2000
5 um filter with carbon cartridge
Required when Mixed Multi is purchased 90134022 50134022
Europe 06.1000 06.1000
Hardness detection kit — required with purchase of softener
Alerts user when water is no longer softened North America/Latin America
Asia Pacific 90134335 50134335
Optional Accessories
Sterile 0.2 ym filter for reservoir outlet 06.5555 06.5555
Disinfection cartridge
Reusable cartridge needed to clean the water purification system. N Deed
Ultrafilter
Point-of-use ultrafilter to reduce levels of pyrogens and nucleases in the product water. 031022 Pe
Printer 120V, 50/60Hz AY1137X1 AY1137X1
Utilizes RS-232 interface for safe documentation of all measured values and
faults with date and time in compliance with GLP-Guidelines 230V, 50Hz 09.2207 09.2207
Hand Dispenser Kit
Hand dispenser with 3 meter cord that connects to tank (to dispense Type 2 water). 50138221 50138221
Ships with a 0.2 micron final filter.
Qualification documents (IQ0Q) IOQD0CE50133916 IOQD0CE50133916
Replacement Consumables
Ultrapure polisher cartridge 09.2005 09.2005
5 ym filter and hardness stabilizer 06.5204 06.5204
Sterile 0.2 ym filter for system 09.1003 09.1003
UV lamp for system 09.2002 09.2002
09.2202 09.2202
CMX25 CMX25
Europe/ Asia Pacific
Cleaning solution
North America/Latin America
Reverse osmosis membrane 22.0046 (requires 2) 22.0087 (requires 2)
“@ CE
www.thermoscientific.com/purewater 47
Thermo Scientific Barnstead Smart2Pure
water purification system
All in one! The Barnstead Smart2Pure system is a compact system which converts tap water to into both ASTM Type | and II water.
The Smart2Pure 3 and 6 feature a built-in 6 L reservoir to store the Type 2 water. The Smart2Pure 12 offers the choice of a 30 or
60 L reservoir for customizable storage capacity.
Powerful performance
e Based on your requirements, choose from capacities of 3, 6 or 12 L/hr
Lasting economy
e Water purification progresses through independent cartridges with Aquastop
quick-connect for fast replacement
Module 1 — Combination of pretreatment and the reverse osmosis
membrane
Module 2 — Polishing cartridge contains high-quality ultrapure resin for
consistent purity and long cartridge life
Easy-to-operate
e Dispensing is easy and features variable speed to control flow
e The display can be tilted for optimal reading
e Optional UV bulb and ultrafilter to customize ultrapure water quality
Placement options
e Position on laboratory bench
e Mount it on the wall
Smart2Pure 3 and 6 features smart, integrated 6 L reservoir
e Constructed with pigment-free materials
e Conical bottom outlet allows for complete draining and efficient cleaning and
Molecular Biology and Microbiology disinfection
e Cell and tissue culture Smart2Pure 12 offers reservoir options, either 30 or 60L
e Large opening for easy and effective cleaning by hand
e Sterile venting filter/reservoir overflow protects against contamination by
microorganisms
CO. adsorber prevents TOC value increases from drawn-in CO,
e Polyethylene reservoir is opaque to light
e Recirculation pump protects the high purity water from bacterial growth during
standstills and maintains the low conductivity value
e Wall-mount optional for simple space-savings
e Conical bottom outlet allows for complete draining and efficient cleaning and
disinfection
e PCR, DNA sequencing
e Electrophoresis
Analytical Chemistry
e HPLC
e GC, GC-MS, ICP-MS, AA
e TOC Measurements, IC
Routine Laboratory Work
e Preparing and diluting buffers and reagents
e Rinsing lab glassware
e Supplying autoclaves and other small lab
equipment
————————"_ compact
dual quality system
48
P.
oa
m
—
Qo
NO
Quick Look Comparison
Type 1 Water
Inorganic and organic trace OET: Molecular biology, PCR,
analysis, HPLC, ICP-MS, m eana a m= DNA, monoclonal antibodies,
IC, TOC analysis cell culture media
Conductivity, pS/cm 0.055 0.055 0.055 0.055
Endotoxines, EU/mL n/a n/a <0.001
Type 2 Water
Pure water production at 15°C, L/h 3,0 06 12 3, 6/06 12 3,0 06 12 3, 6 or 12
Resistivity at 25°C, MO.cm 15-10 15-10 15-10 B=)
Conductivity, pS/cm 0.067-0.1 0.067-0.1 0.067-0.1 0.067-0.1
AA, IC, ICP,
Applications standard buffer
SWƏJSÁS UONCDIUN, 1878M ƏMNdeNIN
Feed Water Requirements*
Source Tap water
pH range 4-11
Temperature, C° 2-35
Pressure, psi (bar) 1.4-87 (1-6)
* Please see user manual for complete list of feed water requirements
Space-Saving Design
Simply stand the Smart2Pure system on
the benchtop or mount it directly to the
wall, as shown by the Thermo Scientific
MicroPure, for more bench space
www.thermoscientific.com/purewater
Thermo Scientific Barnstead Smart2Pure
water purification system (continued)
50
Economical Design
The RO membrane with pretreatment cartridge is
separate from the DI cartridge, ensuring you only
replace each cartridge as needed
Flexible Storage
Store high purity water safely and conveniently in either
a 30 or 60 L reservoir (only for Smart2Pure 12)
UV-Oxidation 185/254 nm Flexible
Optional UV-oxidation for reducing Gain increased flexibility by adding a
the content of microorganisms and hand dispenser with 3 meter cord
their metabolites
Product Specifications — Storage Reservoirs
£ Dimensions
Volume Material Hx D in (mm)
Polyethylene, ultrapure water (598 x 380)
resistant, opaque to light 35.9 x15
aa (912 x 380)
Storage Reservoir Options for Smart2Pure
12 System Only
Tank
Choose a tank to meet your capacity needs 06.5040 06.5070
Required Accessories
Sterile overflow for reservoir 06.5001 06.5001
CO, adsorber + sterile filter, 0.2 ym 06.5002 06.5002
Optional Accessories
UV lamp assembly for the tank, 230V, 50Hz
Ships complete with assembly and UV lamp
06.5006 06.5006
Wall mounting bracket 06.5015 06.5016
Replacement Consumables
Replacement UV lamp (reservoir), 230V, 50Hz 09.5002 09.5002
Product Specifications - Smart2Pure 3, 6, 12 L/hr
Operating pressure Electrical : Feed water Dimensions
min/max requirements OTe C ay connector W x D x H in (mm)
. 29-87 psi i ji 12 x 15.7 x 21.5
up to 1 L/min 90-240V, 50/60Hz 0.06kW 3/4" NPT (305 x 400 x 545)
Flow rate
Smart2Pure System 3 and 6 L/hr*
All systems include an RO/pretreatment cartridge, 3 L/hr 90129869 90129872 90129870 50129688
ultrapure polisher cartridge, sterile 0.2 um filter,
pressure regulator, UV lamp and/or UF filter where
applicable. The 3 and 6 Iph models also include an | 6 L/hr 50129873 50129885 50129874 50129887
internal 6L tank with vent filter.
Required Accessories
Pretreatment filter
Required to prolong cartridge life. Ships with a filter housing and 1m filter. 09.4003 09.2003 09.4008 Bele
Optional Accessories
Wall mounting bracket 09.2212 09.2212 09.2212 09.2212
Qualification documents (IQ0Q) IOQDOCE50133911 IOQDOCE50133911 IOQDOCE50133911 IOQDOCE50133911
Hand Dispenser Kit
Hand dispenser with 3 meter cord that connects to tank. 50138221 50138221 50138221 50138221
Ships with a 0.2 micron final filter.
Smart2Pure System 12 L/hr*
systems include an RO/pretreatment cartridge, an ultrapure polisher
cartridge, sterile 0.2 um filter, pressure regulator, UV lamp and/or
UF filter where applicable
50129888 50129890 90129889 90129845
Required Accessories
Smart2Pure Reservoir
Choose a reservoir that fits your needs
See “Storage Reservoir Options”
Pretreatment filter
Required to prolong cartridge life 09.4003 09.4003 09.4003 09.4003
ships with a 10 inch filter housing and 1 um filter
Optional Accessories
Wall mounting bracket for the system 09.2212 09.2212 09.2212 09.2212
Qualification documents (1000 IOQDOCE50133912 | IOQDOCE50133912 | IOQDOCE50133912 | IOQDOCE50133912
Hand Dispenser Kit
Hand dispenser with 3 meter cord that connects to tank. 50138221 50138221 50138221 50138221
Ships with a 0.2 micron final filter.
Replacement Consumables - Smart2Pure 3, 6, 12 L/hr
09,200
RO membrane with integrated pretreatment 09.2006
Ultrapure polisher cartridge 09.1020
Sterile 0.2 ym filter for system 09.1003
Ultrafilter Om | a [| om 50133981
Europe/Asia Pacific 09.2202 09.2202 09.2202 09.2202
Cleaning solution
g North America/ CMX25 CMX25 CMX25 CMX25
Latin America
1 micron prefilter for 09.4003 | 06.5101 5101 | 06.5101 5101 06. | 06.5101 06.5101
Sterile vent filter for tank 3 L and 6 L/hr — = = — 22.0091
“"@ CE
www.thermoscientific.com/purewater 51
G 8 + AdAL
=
=
—
Q)
O
=
-x
(qp)
o
~F
(gP)
-=
“UO
=
=“
=e
(ap)
o
=F
=)
=.
Tp)
<
p]
mF
(gP)
=
Sp)
TYPE 2
ure
Pure water for a wide range of applications
Type 2 pure water is an essential part of creating consistently
pure chemical reagents, microbiological buffers and media.
Type 2 water is also recommended as a pretreatment for
Type 1 ultrapure systems.
Innovation
Advanced feed water monitoring alerts
user to fluctuations in feed water quality
to optimize cartridge
convenience’,
Ca
Aquastop connections allow users
to quickly change the cartridge and
minimize downtime
|
flexibility rs
Gain more space with numerous
installation options — on the bench,
wall or standalone
www.thermoscientific.com/purewater 53
* = Select the >
System
© TYPE 2
| Therm lentific Barn
< pure water purification system
a. selector guide
-ia
E ai Technology / Feature Benefits
& wy >
7s E
Take into account any new techniques you will
introduce in the coming years or new volume
demands you may have
Optimal amount of water to use daily to
sustain reasonable cartridge life
Technology UV Oxidation Protects against microorganism
Automatic operation Total operation of the system is automatic
Multiple choices of dispense Flexible options for dispensing
Upgradable If capacity needs increase, the system can be upgraded
54
p=: b =~
-— È
| i ul jiii
q 7 i “Stn f —
Koa eee SU Mega-Pure Stills Cabinetized Stills
water purification system § water purification system
Multiple capacities available Flexible dispensing All glass design Heke MIE UCR AUT Tin-lined
space saving design
3-40 L/hr 20-40 L/hr 1.4-13 L/hr 7.6-19 L/hr 1.9-38 L/hr
Optional Optional — Optional for reservoir Optional for reservoir
Standard Standard Optional Standard Optional
i Standard — — =
Standard Standard — — —
www.thermoscientific.com/purewater 55
Thermo Scientific Barnstead Pacific TII
water purification system
The Barnstead Pacific TII water purification system converts tap water into high purity water. The ultimate system for the
automatic and economical production of Type 2 water, the Pacific TII system supports daily requirements from 20 to 200 liters.
e Rinsing lab glassware
e Supplying autoclaves and
ultrapure water systems
e Preparing and diluting buffers,
reagents, and media
56
Multiple options for Type 2 water
e Five system options with permeate flows of 3, 7, 12, 20, or 40 L/hr
e Future system upgrades accommodate greater capacities to meet growing
water demands
e Space-saving design permits benchtop installation or wall mounting with
integrated mounting bracket
Operational reliability
e Microprocessor controlled for automatic operation with continuous monitoring of
all critical parameters
e Automatic return to “operating” mode ensures recirculation during standstill
periods
e Optional UV lamp prevents biological contamination
Easy-to-operate
e Resistivity/conductivity clearly displayed on large back-lit control panel that tilts
for optimum viewing
e Status of current operating mode clearly indicating “production”, “stand-by”,
“cleaning” or “disinfection” modes
e Reservoir fill-level shown as %
e System parameters are code-protected to prevent accidental changes to
set points
e Water is dispensed directly from storage tank
GLP-Compliant documentation
e Optional printer connects to RS-232 port for data recording and traceability
e Cell constant of 0.01cm"' ensures precise conductivity measurements
e Temperature compensation for the conductivity measurement has an accuracy
of +0.1°C (in conformity with USP 645)
Volume display
e Water level % in reservoir is shown automatically on the Pacific TII display
Clear information
Large, illuminated four-line display is easy to read and provides information on:
e Operating mode status, such as production, stand-by, disinfection
e Reservoir volume in %
e Temperature in °C
L) mi Ñ
NE SEL.
with ultimate flexibility
Quick Look Comparison
Pacific TII Pacific TII Pacific TII Pacific TII Pacific TII
3 L/hr system 7 L/hr system 12 L/hr system 20L/hr system 40 L/hr system
Resistivity at 25°C, MQ'cm 15-10 15-10 15-10 15-10 15-10
Conductivity, pS/cm 0.067-0.1 0.067-0.1 0.067-0.1 0.067-0.1 0.067-0.1
TOC, ppb <30 <30
SWƏJSÁS UONEONUNd 1978M Bund
Reverse osmosis membrane
The high performance reverse osmosis membrane removes
approximately 98% of inorganic ions and 99% of all dissolved
organic substances as well as microorganisms and particles.
High purity water cartridge
This cartridge further purifies the reverse osmosis permeate to
produce high purity water as required by international standards
(ASTM Type Il, CAP, ISO 3696, BS 3997 and CLS).
UV lamp (UV version only):
The 254 nm UV transmission ensures optimal UV irradiation. Light
of wavelength 254 nm acts as germicide.
Recirculation
Recirculation of the water between the storage reservoir and
Pacific TII is important for maintenance of the water quality. Water
from the reservoir is cycled through the high purity water cartridge
and the UV chamber, then back to the reservoir. (available only for
systems that include a tank with recirculation/pressure pump)
Mer
thermoscientific.com/purewater 57
= = popune." ro —— oo SS
S = —" —
= — _— =
a _
s
Thermo Scientific Barnstead Pacific TII
water purification system (continued)
The Barnstead Pacific TII system converts tap water to 15-10 MO:-cm high purity water.
Pacific TII reservoirs
e Store high purity water safely and conveniently!
Large opening
e For easy and effective cleaning by hand
Optional safety filters:
e A CO, adsorber prevents conductivity increases from drawn-in CO.
e Sterile overflow prevents microorganisms from entering and contaminating
reservoir water
Polyethylene reservoir
e Constructed with inert materials opaque to light
Recirculation pump
e Recirculation pump protects high purity water from bacterial growth during
standstill while maintaining a low conductivity value
Wall mount
e Simple and space-efficient wall mounting
Conical bottom outlet
e Allows complete draining and efficient cleaning and disinfection
Specifications and Ordering Information
Feed Water Specifications”
Source and pre-treatment Tap water, softened or hardness stabilized
Conductivity, pS/cm < 1500
Free chlorine concentration, mg/L <01
pH-Range 4-11
Temperature, °C 2-35°C
Pressure, psi (bar) 29-87 (2-6)
*complete list of feed water specifications can be found in the operational manual
Pacific TII System
Feed water Dimensions Ambient
Operating pressure Electrical requirements Power consumption
connector WxDxH temperature
29-87 psi 90-240V, R 14.6 x 13 x 23.7 in
(2-6 bar) 50/60HZ we eel (372 x 330 x 603 mm)
Storage Reservoir
Volume Material Dimensions
30 L 23.5 x 14.9 in (598 x 380 mm)
Polyethylene, ultrapure water resistant,
60 L opaque to light 35.9 x 14.9 in (912 x 380 mm)
100 L 49.2 x 14.9 in (1249 x 380 mm)
58
aw ™,
"A
D u >ý _~ J X bs b, td É
J Ea 3 " << = a è
System Options UV option Pacific TII 3 Pacific TII 7 Pacific TII 12 Pacific TII 20 Pacific TII 40
50132129 50132131 50132132 50131982 50132133
50132121 50132123 50132124 50132125 50132127
See “Storage Reservoir Options” below
Pacific TII Systems
All systems have a built-in wall bracket and
include an RO membrane, a high purity water
cartridge, pressure regulator, and UV lamp
where applicable
Required Accessories
Pacific TII Reservoir
Choose a reservoir that fits your needs
Double cartridge pretreatment system
A 5 um filter with activated carbon cartridge and a hardness stabilizer
cartridge ship complete with two 10 inch filter housings to control
chlorine, organic impurities and control hardness <250ppm TIS
For full pretreatment options, see p. 86
09.4000
Optional Accessories
Qualification documents (IQ0Q)
IOQDOCE50133915 | IOQDOCE50133915 | |OQDOCES0133915 | IOQDOCE50133915 | IOQDOCES0133915
16.0129 16.0129 16.0129 16.0129
Water watcher
Alerts the user to leaks — available as 230V, 50Hz only
Printer
T T estaeee 120V, 50/60Hz AY1137X1 AY1137X1 AY1137X1 AY1137X1
documentation of all measured values and
faults with date and time in compliance 230V, 50Hz 09.2207 09.2207 09.2207 09.2207 09.2207
with GLP-Guidelines
Hand Dispenser Kit
Hand dispenser with 3 meter cord that connects to tank. Use only
with a tank equipped with a pressure pump (06.5032, 06.5062, Tem SUNS ANE) 3019822] SUE
06.5082). Ships with a 0.2 micron final filter.
Replacement Consumables
High purity water cartridge 09.4011 09.4011 09.4011 09.4011 09.4011
Reverse Osmosis membrane
Pacific TII 3, 7, 12 only require a single RO membrane 22.0046 22.0046 22.0046 mae ae
Pacific TII 20 and 40 require two membranes as indicated
System UV lamp 09.4002 09.4002 09.4002 09.4002 09.4002
Europe/Asia Pacific 09.2202 09.2202 09.2202 09.2202 09.2202
Cleaning solution i
North America/ CMX25 CMX25 CMX25 CMX25 CMX25
Latin America
Activated carbon cartridge with 5 m prefilter 06.5201 06.5201 06.5201 06.5201 06.5201
Hardness stabilizing cartridge 06.5452 06.5452 06.5452
Storage Reservoir Options for Pacific TII 30 L
16.0129
SWA}SAS UONEONUNd 1978M Bund
AY1137X1
06.5452 06.5452
60 L 100 L
Reservoir with level display 06.5033 06.5063 06.5083
Choose a tank to meet your capacity and pump with level display and recirculation/pressure pump 06.5032 06.5062 06.5082
Required Accessories
Sterile overflow for reservoir 06.5001 06.5001 06.5001
sterile filter, 0.2 um (ideal choice for tanks without a 06.5003 06.5003 06.5003
Vent filter recirculation pump)
Choose the vent filter for your application needs Sterile filter, 0.2 um + CO, adsorber (ideal choice for
06.5002 06.5002 06.5002
tanks with a recirculation pump)
Optional Accessories
UV lamp assembly for reservoir with lamp, 230V, 50Hz 06.5006 06.5006 06.5006
Wall mounting bracket 06.5015 06.5016 na
Replacement Consumables
Replacement UV lamp (Reservoir) 09.5002 09.5002 09.5002
Sterile 0.2 um filter for system 09.1003 09.1003 09.1003
@ C€
www.thermoscientific.com/purewater
Thermo Scientific Barnstead LabTower TII
water purification system
The Barnstead LabTower TII converts tap water into high-purity water and provides water storage -
for a complete Type 2 water solution.
Consistent water quality
e Type 2 laboratory water meets ASTM Type Il, CSLS-CLRW and ISO 3696
international standards
e Designed to continuously recirculate purified reservoir water to preserve water
quality even during periods of inactivity
Compact mobile design
e Two system options with permeate flows of 20 or 40 L/hr
e Stand-alone design with integrated 100 L reservoir takes up zero bench space
e Castors allow easy relocation
e Systems can be upgraded later to accommodate growing water demands
Two ways to dispense water
e Dispense directly from the system via the dispensing valve for calibration
solutions, reagent preparation, filling of containers, general rinsing purposes, etc.
e Dispense from the reservoir to supply autoclaves, dishwashers, ultrapure water
systems, etc.
Integrated 100 L reservoir
e Up to 100 L of high purity water ready for dispensing when needed
e High purity polypropylene reservoir is opaque to light
e Conical bottom allows complete emptying for efficient cleaning and disinfection
e Adjustable setting for reservoir volume can be programmed for times when
demand is low, allowing you to only store water that you can use
Clear information on system display
e The large four-line display is code-protected to prevent accidental changes in
system settings
e Rinsing lab glassware
e Supplying autoclaves and e |lluminated and easily readable, the display provides information on resistivity or
ultrapure water systems conductivity, operating mode status, such as “production”, “stand-by” or
a sanitization, and volume of the reservoir in %
e Preparing and diluting buffers,
reagents, and media GLP-compliant documentation
e Developed to meet or exceed GLP requirements
e Recorded and traceable data can be obtained by print-out via the RS-232
interface and accessory printer
e Highly qualified and precise measurement of the conductivity is ensured by the
cell constant of 0.01 cm"! to an accuracy of + 0.1°C
60
with integrated 100 L tank mn
Quick Look Comparison
LabTower TII LabTower E
system system
Pure water production at 15°C, L/hr 20 or 40
Resistivity at 25°C, MA'cm 10-1
Conductivity, pS/cm 0.1-1
Bacteria content, CFU/mL, with sterile filter <]
Particle content (0.2 pm) per mL with sterile filter <i
iar
5 um prefilter and activated carbon in the combi-filter cartridge
protects the RO membrane from chlorine and particles
Hardness stabilizing cartridge protects the reverse osmosis
stage from hard water
f >l Sic >
Pretreated water is pressure-forced through the permeable
reverse osmosis module removing 97— 99% of all inorganic
ions, 99% of dissolved organic substances as well as
microorganisms and particles
The built-in 100 L reservoir has a conical bottom outlet to
optimize cleaning and sanitization
RO membrane removes up to 99% of impurities. All remaining
ions are removed by the low TOC, high-purity resins in the ion
exchange cartridge.
Irradiation with UV light (TII units with UV option only)
eliminates any bacteria or germs that are present
LabTower TII with optional
hand dispenser
IR
www.thermoscientific.com/p
La
hy
62
Thörn
Specifications and Ordering Information
Feed Water Specifications”
Source Potable tap water softened or hardness stabilized
< 3, with higher values, an upstream pretreatment
Blocking imdex (SD) (model no. 09.4000) is to be installed
Conductivity, pS/cm < 1500
Free chlorine, mg/L g 0i
Colloid index <3
ph-Range 4-11
Temperature, °C 2-35
Pressure, psi (bar) 29-87 (2 -6 )
*complete list of feed water specifications can be found in the operational manual.
63
LabTower TII
Feed water Dimensions Ambient
connector W x D x Hin (mm) temperature
90-240V, 17.7 x 22.8 x 59
50/60Hz even ae NE (450 x 580 x 1500)
LabTower Lab Tower LabTower
TII 20 TII 40 TII 60
LabTower TII Systems*
All systems include an RO membrane, a high purity Seon STs Suhel ae
water cartridge, 10 inch 5 um prefilter with hardness
Stabilizer cartridge, pressure regulator, 0.2 um filter, Somwa 50132191 50132196 50132393
Required Accessories
integrated 100 L reservoir and UV lamp where applicable
5um filter with activated carbon
Both cartridges are required for complete pretreatment
1pm filter with a 10" filter housing 09.4003 09.4003 09.4003
Sterile vent filter for reservoir 06.5003 06.5003 06.5003
Sterile overflow for reservoir 50132714 50132714 50132714
Optional Accessories
UV lamp assembly for reservoir, 230V, 50Hz only 06.5006 06.5006 06.5006
Includes holder and UV lamp
Water watcher
Alerts the user to leaks. Available as 230V, 50Hz only Joules OU oraa
Printer
Utilizes RS-232 interface for safe documentation of all i DONI ae RISTA AASER
measured values and faults with date and time in 230V, 50Hz 09.2207 09.2207 09.2207
compliance with GLP-Guidelines
Qualification documents (1Q/0Q0) I0QD0CE50134156 I0QD0OCE50134156 I0QD0OCE50134156
Hand Dispenser Kit
Hand dispenser with 3 meter cord that connects to tank. Ships with a 0.2 micron final filter. aeee DU iei MNS
Replacement Consumables
High purity water cartridge 02.2850-LAB 02.2850-LAB 02.2850-LAB
Reverse Osmosis membrane
LabTower TII 20 and 40 require two membranes, and LabTower TII 60 requires four
membranes, as indicated
System UV-lamp 09.4002 09.4002 09.4002
Sterile 0.2 ym filter 09.1003 09.1003 09.1003
Europe/Asia Pacific 9.2202 09.2202 09.2202
Cleaning solution
0
Activated carbon cartridge with 5 pm prefilter 06.5201
Hardness stabilizing cartridge 06.5452
Replacement UV lamp (reservoir, 230V, 50Hz only) 09.5002
5 pm prefilter and hardness stabilizer 06.5204
'@ CE
Operating Electrical
pressure requirements Power consumption
29-87 psi
(2-6 bar) 2-35°C
System Options UV option
22.0046 22.0087 22.0087 (must order 2)
(must order 2) (must order 2) and 22.0046 (must order 2)
www.thermoscientific.com/purewater
-U
(=
=
14>)
&
mF
CD
F
-U
=
=
=h
(qp)
&
=
(æ)
=
WM
<
(op)
(a
(gP)
=
Sp)
Thermo Scientific Barnstead Mega-Pure Glass Stills
Barnstead Mega-Pure Glass Stills effectively remove inorganic solids, organics with boiling points higher than water,
bacteria, and pyrogens. The stills are constructed of non-leaching components to ensure high purity water.
il.
Product Features
e Contact with only glass, quartz and Teflon® components ensures ultimate
purity and eliminates cross-contamination
Choice of five production capacities
Units are easily wall- or bench-mounted
Vertical condenser design provides maximum purity
High temperature cut-off shuts down the still if the temperature is too high,
preventing heating element burnout
Quick release cover provides easy cleaning access
Connection to Automatic Collection System (ACS) assures a 24-hour
automatic system
Includes feed water solenoid valve for automatic operation
Produces water with a resistivity of 1-10 MQ-cm, depending on feed
water purity
MP-1
e Compact, easy-to-use 1 L/hr glass still available with
or without a storage bottle
MP-3A, MP-6A and MP-11A
e Rinsing lab glassware e Ideal for larger volume demands with storage and options
e Supplying autoclaves and
ultrapure water systems MP-12A
e Built-in deionizer for pretreated feed to boiler. Distillate cooler allows product
water to be used as it is produced, cooling it from 85-55°C for ease of handling.
No need to wait for cooling
e Preparing and diluting buffers,
reagents, and media
Quick Look Comparison
MP-1 MP-3A MP-6A MP-11A MP-12A
Deionizer
and distillate
cooler
Cooling water capacity, L/hr ie 130 130
Resistivity at 25°C, MO'cm 1-10 1-10 LEO 1-10 1-10
Compact,
System features easy-to-use
Stills for larger volume demands
64
Product Accessories
Lr y
e All glass system designed to collect water from the
Mega-Pure Glass Stills and control their operation
Generous 45 L capacity
Easy wall- or bench-mount
Preset to shut off the power to the heaters and the
water supply to the still after the bottle has collected
approximately 45 L
The system will automatically restart the still and
refill the collection system when the purified water
supply has been depleted to approximately 38 L
Allows for pretreating feed water to Mega-Pure
Glass Stills
Mega-Pure single or dual cartridge deionizer
reduces scale build up and increases distillate purity
Greater flexibility in meeting varying feed water
qualities
Temperature-compensated purity meter measures
water quality and indicates when cartridges are
exhausted
Built-in drain valve for simple cartridge changes
Large cartridge capacity for extended cartridge use
Unit can be wall- or bench-mounted
Ss E
4 a
Plastic Bottle (413964)
biological applications ~
T
Glass Bottle (410535)
Automatic Collection System
www.thermoscientific.com/purewater
Mega-Pure Deionizer D2
65
Thermo Scientific Barnstead Mega-Pure Glass Stills (continued)
Specifications and Ordering Information
Product Specifications
Inlet water temperature°C (°F) Vent temperature°C (°F) Auto drain Inlet pressure (psig) Auto start/stop controls
4-37 (39.2-98.6) 85-96.7 (185-206) PN 20-100
system Options
Volume
output
(L/hr)*
Overall dimensions Electrical (50/60 Hz) Model number
ee) Volts Unit 6 L bottle included
18x 34x 975 Eee 028 | 80267
Ee! ae “° Meee
29445 x12 ere 7
MP-1**
MP-3A**
2 (58.4 x 114.3 x 30.5)
ne 23 x 45 x 12 ak paca E
29.2 x 63 x 14.4 240 A440118 ;
mes Ee |
20.2 x 53x 14. i amaan -
Model Number
440236
MP-11A**
MP-12A
Built-in deionizer (holds two
cartridges) and distillate cooler
Required Accessories
Dual solenoid MP-1 (240V), MP-3, MP-6A and MP-11A
Required if using pretreated boiler feed water and untreated cooling water
MP-1 (120V) RY798X2A
Deionization cartridges
Required for MP-12A. See Optional Accessories
Storage solutions
see Storage Options
Optional Accessories Model Number
Single cartridge deionizer (D1)
Single cartridge deionizer removes inorganic contaminants. Order one deionization cartridge to complete your system. D440046
Dimensions: W x H x D — 10.5 x 25.5 x 7.5 in (26.7 x 64.8 x 19 cm)
Dual cartridge deionizer (D2)
Provides increased capacity with chlorine and organic removal. Order two deionization cartridges to complete your system. D440066
Dimensions: W x H x D — 16.75 x 25.5 x 7.5 in (42.6 x 64.8 x 19 cm)
Still adapter kit 440376
— : Required to connect the Deionization System to any Mega-Pure Glass Still
Deionizer accessories
Solenoid valve accessory kit 440375
For use with the D1 or D2 when used as stand alone units
High purity cartridge
Used in the MP-12A, D1 and D2 unit for high purity D200
E : High capacity cartridge
Petonizauen cartridges Used in MP-12A, D1 and D2. Removes ionized solids for extended capacity ee
Organic removal cartridge
Used in D2 for organic and chlorine removal 0240209
*Volume Output for 208V units can be reduced up to 25% less than specified. kk G
66
Model Number
Plastic bottle, 6 L capacity
For use with MP-1 and MP-3A stills HIS
Glass bottle, 9 L capacity 410535
Storage bottles For use with MP-1 and MP-3A stills
For manual operation Glass bottle, 13 L capacity T
For use with any Mega-Pure Glass Still
Glass bottle, 45 L capacity 410164
For use with any Mega-Pure Glass Still
Automatic collection system (ACS) unit B440704
Automatic collection system (ACS) Flexible tubing adapter kit
For use with any Mega-Pure Glass Still. Needed when the supplied glass tubing is either too long or too short to reach still. Flexible 440138
Collects up to 45 L of water and controls the still. | tubing is not included. 0.5 inch Teflon tubing able to handle 80-90°C water is recommended
Dimensions: W x H x D
16.25 x 38 x 16.25 in (41.3 x 96.5 x 41.3 cm) ACS wall mounting bracket 400634
Adapter for ACS washer hook-up for glassware washers 440241
Storage Options
SW9]SAS UONEIIJLING 1978M ON
www.thermoscientific.com/purewater
Thermo Scientific Barnstead Classic Stills
Barnstead Classic Stills effectively remove inorganic solids, organics, bacteria, and pyrogens.
The stills are constructed of copper and bronze with a coating of pure tin. The inert nature of tin
prevents any leaching of contaminants into the water.
Product Features
e Double-walled boiler and preheating of feed water conserves electricity
e Vented condenser allows for stripping of gaseous impurities
e Unique de-concentrator removes scale forming impurities from the boiler
e Unique Thermo Scientific Q-Baffle ensures high quality pyrogen free water
by stripping contaminant laden water droplets from steam
e Space-saving horizontal condenser
e Metal construction withstands years of use
e Units are easily floor and bench mountable, depending on model
e İnert pure tin pathways assure product water quality
P e Controller unit can be wall mounted
Portable Stills
e Requires no permanent plumbing or electrical connections, allowing quick
ar set-up
e Includes low water cut-off for safety protection
e Bench-mounted
Floor Model Electric Stills
e Come standard with floor mounting stand
e New over temperature protection system improves safety
e New plug-and-play hardware allows for easier installation
e Capacities from 1 to 10 gal/hr
Low water cut-off protects heating elements when water supply is interrupted
Optional fully automatic controls allow for unattended operation
— Stops still when storage reservoir is full, starts still when water level falls
below preset level
— Drains still boiler at selected 4-hour intervals to reduce scale formation
Steam Still
e Utilize available in-house steam as heat source
e Optional automatic controls allow for unattended operation
— Stops still when storage reservoir is full, starts still when water level falls
below preset level
— Drains still boiler at selected 4-hour intervals to reduce scale formation
e Rinsing lab glassware
e Supplying autoclaves and
ultrapure water systems
e Preparing and diluting buffers,
reagents, and media
Quick Look Comparison
Portable ene Steam
Flectric Stills Floor Model Electric Stills Stills
al
i =
Ses
k
pe |
[s
j
Specifications and Ordering Information
Tin-Coated Storage Reservoir Specifications
Cooling Electrical (50/60 Hz)
WEL Phase
gal/hr (L/hr) Volts
Dimensions Model
W x Hx D in (cm) number
Output
gal/hr(L/hr)
SWA}SAS UONEONUNd 1978M Bund
1/2 gal/hr
1 gal/hr
Electric stills*
included
except A1007) es arre muat
10 gal/hr | 10(38) | 80 (303) | EIEN Cc 37 (94) | 89 (226) | 14(36) | A1016-D
eb Keres e Steam pressure Boiler Steam lb/hr Dimensions Model
Steam stills* fi Ihr) Lh (PSI) horsepower (kg/hr) W x Hx D in (cm) Number
10 gal/hr | 10(38) | 38 (144) 35-50 90 (41) | 374) | 90(229) | 14 (36) A1213
*“Volume Output for 208V units can be reduced up to 25% less than specified.
Required Accessories Model Number
Steam still floor stand For 10 gal/hr steam stills only G1000
Choose a storage reservoir that best fits your needs —
go to Thermo Scientific Barnstead Classic Still Storage Reservoirs and Accessories on pages 70-71
Storage reservoir
Optional Accessories
i For use with 1 and 2 gal/hr electric stills G2100
Fully automatic controls
120V (50/60Hz) includes feed water | For use with 5 gal/hr electric stills G2110
and drain solenoid valves, manual For use with 10 gal/hr electric still G2125
ES, PIPINO allel eve monte For use with 10 gal/hr steam still G2020
®
HU IQ
pure water
www.thermoscientific.com/purewater 69
Thermo Scientific Barnstead Classic Still
Storage Reservoirs and Accessories
Select a Barnstead Classic Still Storage Reservoir and mounting option that will best fit your needs. The Ventgard Air -
Filter, Water Seal and UV Light Assembly are required accessories that will protect your pure water during storage.
Storage reservoirs
e Available in 10 to 200 gallon reservoir options
e Crafted from copper and hand-wiped with pure tin to ensure the purity of the
distilled water
e All reservoirs include a removable cover, water level sight glass and a tin coated
draw-off faucet with serrated hose nipple
e Connections provide for optional accessories including pumps and fully
automated controls
e Requires a floor stand or wall bracket (10 and 25 gallon reservoirs only) for
proper installation
Required Accessories
Floor stand and wall bracket
Choose either a floor stand or wall bracket for proper installation of reservoir
Floor stands
e 10, 25 and 50 gallon reservoir stands are fabricated from heavy gauge sheet
metal and have adjustable feet
e 100 and 200 gallon reservoir stands are fabricated of thick steel angle-iron
Wall brackets
e 10 gallon reservoir brackets are fabricated from heavy gauge aluminum
e 25 gallon reservoir brackets are fabricated of thick steel angle-iron
Venitgard air filter and water seal
e Protects the stored water against airborne particulates, organics and CO.
e Water seal works as a one-way valve to allow distilled water into reservoir
e Prevents air from entering the reservoir via the condenser atmospheric vent
UV light assembly
e Maintains sterility in the reservoir
e UV lamp is enclosed by a tubular, transparent, inert sheath
e When lamp changes are necessary, only the lamp needs to be removed. The
reservoir cover and sheath remain in place eliminating any exposure of water to
contamination from the air
Storage Reservoir Storage Reservoir
Floor Stand Wall Bracket
70
Specifications and Ordering Information
system Options
Overall dimensions in (cm)
Reservoir options Distribution outlet (NPT) Drain outlet (NPT) Model number
D
200 gal* 11/2 in Ss 38 (96) 50 (128) 45 (114) B3049
For the 10 gal reservoir 11 (28) 27 (69) 11 (28)
For the 25 gal reservoir 19 (48) 27 (69) 19 (48)
Mounting options Floor stands For the 50 gal reservoir 22 (56) 20 (51) 22 (56) H1002
aaa ess ie For the 100 gal reservoir 29 (74) 11 (28) 29 (74) H1003
SWA}SAS UONeONUNd 1978M Bund
Required Accessories
your needs. For the 200 gal reservoir 39 (99) 22 (56) 39 (99) H3230
For the 10 For the 10 gal reservoir reservoir H3240
Wall brackets
For the 25 Kok a E reservoir H3242
UV light assembly H4005
Maintains water sterility in reservoir. Includes housing, on/off switch, 6 ft. cord, lamp and ballast
Ventgard air filter and water seal H3111
Replacement Consumables
Replacement UV lamp 04141
Ventgard air filter H3120
Protects stored water against airborne particulates, organics and CO»
Replacement water seal
ee H3130
Prevents air from entering storage reservoirs via condenser atmospheric vent
Ventgard filter element 95001-DB
The consumable portion of the Ventgard filter assembly
O
www.thermoscientific.com/purewater 71
Thermo Scientific Barnstead Cabinetized Stills
Our Barnstead Cabinetized Stills include a still and an appropriately matched tin-coated storage reservoir in a compact
storage cabinet. This space saving design uses less space than conventional units and allows for faster installation.
all-in-one |
tin-lined still and reservoir
Product Features
e Choice of two sizes; 2 or 5 gal/hr
e Q-Baffle ensures high quality pyrogen free product water
e Fully automatic operation allows for unattended operation. Still turns off when
the reservoir is full and restarts when reservoir empties. Automatically drains
the boiling chamber every time the unit is off and every 4 hours of operation,
helping to keep your still clean.
Model 210 Still — 2 gal/hr with 10 gallon reservoir
e Purity meter alerts user of distilled water purity in storage reservoir
e Includes low water cut-off for safety protection
Model 525 Still — 5 gal/hr with 25 gallon reservoir
The inside of e Purity meter alerts user of distilled water purity in storage reservoir
a Barnstead e Optional recirculation pump and base mounting stand available
Cabinetized Still
e Storage tank equipped with a UV lamp for improved bacterial control
Quick Look Comparison
ROUTINE LABORATORY WORK Model 210 Model 525
2 gal/hr
10 gal
5 gal/hr
25 gal
ar Flow rate
e Rinsing lab glassware
Storage reservoir
e Supplying autoclaves and
ultrapure water systems ,
Optional Accessories
e Preparing and diluting buffers,
reagents, and media Bench stand Model 210 only. A1066
Floor stand For Model 525 only. M521
Lx Wx D: 36 x 18.8 x 35 in (93 x 48 x 89 cm)
Recirculation pump M1522
For Model 525 only. Floor stand (A1521) included.
Specifications and Ordering Information
Product Specifications
s Output Voltage (50/60 Hz) af :
yaten gal/hr Heating Amps Phase Wire PEE Model number
options
(L/hr) Controller element
2 (7.6) 24 x 41 x 15.25 in (60 x 103 x 39 cm) A1065-B
210 still 2
2 (7.6) 24 x 41 x 15.25 in (60 x 103 x 39 cm) A1065-D
5 (19) 36.5 x 48 x 18.75 in (91 x 122 x 48 cm) A1085-B
525 still
(19) 36.5 x 48 x 18.75 in (91 x 122x 48cm) | A1085-D
(Sz)
72
Distillation effectively removes most inorganic solids, all organics with a boiling point greater than water (100°C ),
all bacteria and pyrogens. Gases and low molecular weight organics are not effectively removed by distillation.
Thermo Scientific Barnstead products Still components
include a broad range of stills A still includes a boiling chamber (boiler), electric or steam immersion
Our stills range in size from 1.4 to 38 L/hr. Select from stills heaters, pyrogen reducing baffle, condenser, constant level device
constructed of tin or glass. Many models offer fully and low water cutoff. Options include pretreatment solutions and fully
automatic options or pretreatment options to minimize scaling. automatic controls that allow stills to work automatically with
pretreated feed water and a storage reservoir.
Step-By-Step technologies used
in distillation systems
ae Feed water enters the still through
the Cooling Water/Feed Water Inlet.
As the water passes through the
Inlet, it becomes warmed as it makes
its way to the boiler. It in turn cools
the vapor entering the condenser.
U
=
=
(q»)
ja)
mt
4?)
=“
U
(=
-q
=
(qp)
o
=
(æ)
=]
(Fp)
<
(oe)
"tF
4?)
=
(oe)
©) Water flows from the condenser into -u
the constant level device, then into
the boiler.
COOLING WATER;
©) The water in the boiler is heated. a
Impurities with a boiling point higher
than water (100°C / 212°F) remain in
the boiler, while water and impurities ;
with a boiling point equal to or lower pa
than water are converted to water
vapor. The pure vapor moves up the
boiler through a pyrogens-reducing
baffle and into the condenser.
ATLL”
MATOS OUTLET
mesine
[CONSTANT LEVEL Divi
O In the condenser, the pure vapor is | DRAIN PURE
transported through the condenser
where it contacts tubes or coils
containing cooling water. The pure
vapor contacts these tubes and coils
and is condensed to produce pure
water.
ans
© The distilled water exits the condenser
and is stored in a reservoir through
the Distilled Water Outlet.
O Atmospheric vent allows for volatile
contaminants to be vented, increasing
the purity of the distilled water.
www.thermoscientific.com/purewater 73
reverse osmosis
water purification systems
Water purified using reverse osmosis is useful in
supplying water to lab equipment such as water
baths, dishwashers and autoclaves.
Innovation
Thermo Scientific Barnstead
LabTower RO system allows the
tank level to be set manually
convenience
Dispense easily from the tank
flexibility
Endless mounting choices —
on the bench, on the wall, or
free-standing
www.thermoscientific.com/purewater
reverse
osmosis
76
Reverse osmosis is economical
Reverse osmosis is the most economical method to remove up to 99% of impurities in feed water. The RO
membrane is semi-permeable with a thin microporous surface that rejects virtually all dissolved materials
including inorganic solids, organics, particles and microorganisms.
Reverse osmosis water is versatile
RO water can be used to prepare microbiological buffers and chemical reagents. Additionally, it is a great
option for use in general laboratory equipment, such as water baths, humidifiers, and autoclaves.
Reverse osmosis Is effective
As the feed water passes through the RO membrane, impurities deposit on the surface of the RO membrane
and are flushed away to the drain. The result is purified product water free of up to 99% of its impurities.
The specific rejection rates of all the impurities are shown in each of the product specifications.
Feed water factors
Certain characteristics of your feed water directly relate not only to membrane performance and lifetime
but also directly impact the quality of your product water.
Take advantage of our Thermo Scientific H20 Select Analysis Kit, our free comprehensive testing program
which will analyze your feed water to ensure optimum RO performance.
More More
Concentrated Concentrated
Pure Water Solution Pure Water Solution
External
Pressure
|
Pressure
Semi-permeable Semi-permeable
Membrane Membrane
Osmosis Reverse Osmosis
The natural osmosic flow of water through a semi-permeable membrane from less
concentrated solutions to more concentrated solutions. Reverse osmosis is achieved when
external pressure is applied to reverse this natural flow, as shown on the right.
fn SL
i ae O o $
- ——
æ
ail
Our technical service experts are a great resource
for any feed water questions you might have.
Here is an explanation of key characteristics impacting
RO performance:
Temperature
Volumes listed for the reverse osmosis product water are based on a feed
water temperature of 15°C (59°F). For every 1°C below 15°C (59°F), the
quantity of product water is reduced by 3%. Additionally, if the feed water
temperature goes beyond 25°C (77°F), the RO membrane may be damaged.
We recommend a hot and cold water mixing valve to regulate the temperature
to 15°C (59°F).
Alkalinity and calcium
Carbonates, bi-carbonates, hydroxides and calcium impurities in your feed
water contribute to RO membrane scaling. Both the Thermo Scientific
Barnstead Pacific RO and Thermo Scientific Barnstead LabTower RO systems
have pretreatment solutions to prevent this. Included in the pretreatment
system is a hardness stabilizer cartridge which binds calcium, thereby
protecting the RO membrane.
Chlorine
Chlorine can damage the RO membrane and reduce its performance and
useful life. Again, both Pacific RO and LabTower RO have solutions to pretreat
the water, which includes a 5 um prefilter + activated carbon cartridge to LabTower RO with optional hand dispenser
prevent entry of particles > 5 ym and high concentrations of free chlorine.
Turbidity
The turbidity level indicates the amount of suspended solids present. This
suspended material can shorten the life of filters and reverse osmosis
membranes if not removed. Our Pure Water Experts can recommend
pretreatment options if turbidity is an issue with your feed water. RO
membranes show very little fouling when the feed water has a turbidity of
less than 1 NTU.
SDI (Silt Density Index)
Suspended solids and colloidal materials in feed water are one of the biggest
problems in reverse osmosis systems. In order to have some measure of the
degree of this fouling problem, a concept called Silt Density Index is used.
Here a 0.45 um filter is exposed to the feed water under pressure and
filtration rates are calculated. A SDI of <5 is considered acceptable for the
reverse osmosis systems.
www.thermoscientific.com/purewater 77
TE ve
Sy ey
= 7 ;
~~.
af oS
"i af é
g> ;
*
-
Therm ientific Barnst
* reverse osmosis purification system
selector guide
Technology / Feature
> @
Optimal amount of water to use daily to
sustain reasonable cartridge life
Upgradable
Feed water monitoring
Integrated 100 L Reservoir
Pretreatment integrated into system
Benefits
> @
Choosing the right system will give you the most value.
Take into account any new applications you will introduce
in the coming years or new volume demands you may have.
If capacity needs increase, the system can be upgraded
Alerts you to fluctuations in feed water quality
Offers a stand-alone configuration for labs with
little bench space
Pretreatment integrated into system
— o i
Flexible mounting Integrated
options 100 L Reservoir
3, 7, 12, 20, 40 L/hr 20, 40 L/hr
Standard Standard
Standard Standard
— Standard
= Standard
ah 2 Oo
ay
|
Thermo Scientific Barnstead LabTower RO
water purification system
The Barnstead LabTower RO Converts Tap Water into RO Water and stores it in an integrated 100 L reservoir
Advanced technology in a mobile design
e An ultra-modern controller provides easy-to-read system parameters
e Completely drainable integrated 100 L high-purity water reservoir has a
low-noise pressure booster as a standard component
e Mounted on casters, the compact LabTower RO system is an ideal pure water
supply for any laboratory. Ideally suited as a feed water source for dishwashers,
autoclaves and general laboratory use
e A built-in pretreatment unit, consisting of a hardness stabilizer for protection of
the reverse osmosis module from hardness formers
e An activated carbon/5um combi-cartridge protects the system against free
chlorine and particles, ensures the long service life of downstream purification
stages
Compact and mobile design
e Two system options with permeate flows of 20 or 40 L/h
e Stand-alone design with integrated 100 L tank takes up ZERO bench space
e Casters allow for easy relocation
e Systems can be upgraded later to accommodate growing water capacity demands
Integrated 100 L reservoir
e 100 L RO water storage in a high-purity polyethylene PE opaque reservoir
e Adjustable reservoir volume can be programmed for times of low demand
e Dispense from the reservoir to supply autoclaves, glassware washers,
e Rinsing lab glassware incubators, etc
e Supplying autoclaves, water baths, i | Easy-to-operate clear display
incubators and glassware washers ‘|e se Resistivity/conductivity clearly displayed on large back-lit control panel that tilts
e Preparing and diluting buffers and reagents ` | for optimum viewing
.@ Status of current operating mode clearly indicating “production”, “stand-by”, or
“cleaning” modes
e General biotechnology
pe e Reservoir fill-level shown as %
e System parameters are code-protected to prevent accidental changes to
set points
GLP-compliant documentation
e Developed to fulfill GLP requirements
e Recorded and traceable data can be obtained by print out via the RS-232 interface
and accessory printer
e Highly qualified and precise measurement of the conductivity is ensured by the
cell constant of 0.16 cm"
Quick Look Comparison LabTower RO 20 LabTower RO 40
Pure water production at 15°C , L/hr 40
Withdrawal performance from reservoir at 1.5 bar, L/hr 180
Retention quota for inorganics, % > 98
Bacteria content, % > 99
Retention quota for particles, % > 99
SINNALSAS OH
3U water de 1-10
from an integrated system
Feed Water Requirements*
Source Potable tap water that has been softened or hardness stabilized
< 5. With higher values a pretreatment
SHE density Mex (SD) (model no. 09.4000) must be installed upstream of the system.
Conductivity, pS/cm < 1500
Free chlorine, mg/L aos]
pH-Range 4-11
Temperature, °C 2-35
*complete list of feed water specifications can be found in the operational manual
LabTower RO Product Specifications
Dimensions
WxDxH
l 17.7 x 22.8 x 59 in
3/4" NPT (450 x 580 x 1500 mm)
Operating pressure Electrical requirements Power consumption Feed water connector Temperature
90-240V, 50/60Hz 0.25kW
SWAISAS UONeINUNd 19}8M aNd
29-87 psi
(2-6 bar)
System Options LabTower LabTower LabTower
aia RO 20 RO 40 RO 60
LabTower RO Systems*
All systems include an RO membrane(s), 50132390 50132391 50132392
integrated 100 L reservoir, and pressure regulator
Required Accessories
Both are required for complete pretreatment solution 09.4003
Sterile vent filter for reservoir 06.5003
Sterile overflow for reservoir 50132714
Optional Accessories
Printer Utilizes
120V, H AY1137X1 AY1137X1 AY1137X1
RS-232 interface for safe documentation of all measured eve :
values and faults with date and time in compliance with 230V, 50Hz 09.2207 09.2207 09.2207
GLP guidelines
UV lamp assembly for the reservoir with lamp, 230V, 50Hz only 06.5006 06.5006 06.5006
Water watcher
Alerts the user to leaks. Available as 240V only. K Ket 16.0129
Hand Dispenser Kit
Hand dispenser with 3 meter cord that connects to tank. Ships with a 0.2 micron final filter. Ue Wew SUN
Replacement Consumables
Reverse Osmosis membrane
Lab Tower TII 20 and 40 require two membranes, and LabTower TII 60 requires four membranes,
as indicated
10" 5um filter with hardness stabilizer cartridge 06.5204 06.5204 06.5204
Replacement reservoir UV Lamp (230V, 50Hz only) 09.5002 09.5002 09.5002
; ; Europe/Asia Pacific 09.2202 09.2202 09.2202
Cleaning solution - - -
North America/Latin America CMX25 CMX25 CMX25
1pm filter prefilter for 09.4003 06.5101 06.5101 06.5101
5um prefilter + activated carbon 10 inch cartridge 06.5201 06.5201 06.5201
www.thermoscientific.com/purewater * G C € 81
22.0046 22.0087 22.0087 (must order 2) and
(must order 2) (must order 2) 22.0046 (must order 2)
Thermo Scientific Barnstead Pacific RO
water purification systems
The Barnstead Pacific RO system is a modularly designed laboratory reverse osmosis system specifically developed
for functional and economical production of high-purity water.
Product Features
e Five system options with permeate flows of 3, 7, 12, or 20, or 40 L/h
e Space-saving design allows system to sit on the laboratory bench or be
mounted on the wall
e RO membrane removes organic and inorganic contaminants, microorganisms,
particles and colloids
e Simple system upgrade accommodates future pure water capacity
requirements
Reliable operation
e Microprocessor control offers automatic operation with continual monitoring
of all important parameters
Easy-to-operate clear display
e Resistivity/conductivity clearly displayed on large back-lit control panel that
tilts for optimum viewing
e Status of current operating mode clearly indicates “production”, “stand-by”,
or “cleaning” modes
e Reservoir fill-level shown as %
ROUTINE LABORATORY WORK: Integrated feed water monitoring
e Good quality feed water is a prerequisite for high purity water and extends
e Rinsing lab glassware cartridge service life
e Supplying autoclaves, water baths,
GLP-compliant documentation
and incubators
e Real-time clock records system errors and faults
AERE ane: UNTO uererane ERGENS e Ongoing data storage collects four weeks information displayed in clear text
Den elenMIoteeanerody e Operating system is code-protected to prevent unauthorized changes to
system settings
RS-232 interface with adjustable sender interval allows for customized timing
of data transmission of measured values and faults to a PC or data printer
e Cell constant of 0.16 cm-' ensures precise conductivity measurements
Pacific RO pretreatment
e Two 10 inch (25.4 cm) cartridge filter housings with a 5 um prefilter +
activated carbon to prevent entry of particles > 5 um and high concentrations
of free chlorine. Also includes hardness stabilizer cartridge which binds
calcium and prevents its precipitation.
Worry-free pure water storage
e Reservoir are constructed of pigment-free polyethylene
e Conical bottom allows for easy cleaning, disinfecting and complete emptying
82
- ONTIC ATION >
á a
for your RO water needs” ;
=
Quick Look Comparison
Pacific RO Pacific RO Pacific RO Pacific RO Pacific RO ae
3 L/hr 7 L/hr 12 L/hr 20 L/hr 40 L/hr
systems systems systems systems systems
d
Pure water production at 15°C , L/h 40 -l
Salt retention, % En kx N
Retention, bacteria and particles, % ——— lel or lO 99
Feed Water Requirements*
Source Potable tap water that has been softened or hardness stabilized
Silt density index (SDI) < 5, With higher values, a pretreatment (model no. 09.4000 must be installed upstream of the system)
Conductivity, pS/cm < 1500
Prefiltration 5 um + activated carbon
Free chlorine, mg/L <01
pH-range 4-11
Temperature, C° 2-35
*complete list of feed water specifications can be found in the operational manual
www.thermoscientific.com/purewater 83
Thermo Scientific Barnstead Pacific RO
water purification system (continued)
Storage Reservoir
Volume Material Dimensions
30 L 23.5 X 14.9 in (598 x 380 mm)
Polyethylene, opaque to light
60 L 35.9 x 14.9 in (912 x 380 mm)
Pacific RO Product Specifications
Dimensions
WxDxH
Operating pressure,
psi (bar) Electrical requirements Power consumption Feed water connector
Temperature
90-240 V,
50/60Hz
14.6 x 13 x 23.7 in
(372 x 330 x 603 mm)
3/4" NPT 2-30
Ordering Table Pacific RO 3 Pacific RO 7 Pacific R012 PacificRO20 Pacific RO 40
Pacific RO Systems*
All systems have an integrated wall bracket and include an 50132385 50132386 50132387 50132388 50132389
RO membrane and pressure regulator
Required Accessories
Pacific RO Pretreatment
Includes two 10 inch (25.4 cm) cartridge housings, a 5 um prefilter 09.4000 09.4000 09.4000 09.4000 09.4000
+ activated carbon cartridge and hardness stabilizer cartridge
Pacific RO Reservoir
Choose a reservoir that fits your needs See “Storage Reservoir Options” the next page
Optional Accessories
Water watcher
Alerts the user to leaks. Available as 230V, 50Hz only. 16.0123 160123 10.0123 1610123 160123
Hand Dispenser Kit
Hand dispenser with 3 meter cord that connects to tank. Use only
with a tank equipped with a pressure pump (06.5034, 06.5064, 50138221 50138221 50138221 50138221 50138221
06.5084). Ships with a 0.2 micron final filter.
Replacement Consumables
Reverse Osmosis membrane
Pacific RO 3, 7, 12 only require a single RO membrane. 22.0046 22.0046 22.0046 E a
Pacific RO 20 and 40 require two membranes as indicated.
5um prefilter + activated carbon 10 inch cartridge 06.5201 06.5201 06.5201 06.5201 06.5201
Hardness stabilizing 10 inch cartridge 06.5452 06.5452 06.5452 06.5452 06.5452
Europe/Asia Pacific 09.2202 09.2202 09.2202 09.2202 09.2202
deaning solution
North America/Latin America CMX25 CMX25 CMX25 CMX25 CMX25
'@ CE
84
Storage Reservoir Options for Pacific RO 30 L 60 L 100 L
with level display 06.5033 06.5063 06.5083
Reservoir
with level display and pressure pump} 06.5034 06.5064 06.5084
Required Accessories
Sterile overflow for reservoir 06.5001 06.5001 06.5001
Vent filter ese
Choose the vent filter for your application needs SEEN Se pa ous pene
Optional Accessories
UV lamp assembly for the reservoir with lamp, 230V, 50Hz only 06.5006 06.5006 06.5006
Wall mounting bracket 06.5015 06.5016 na
Replacement Consumables
Replacement UV lamp (Reservoir) 09.5002 09.5002 09.5002
SIWNALSAS OH
SWAISAS UONPIIJUNd 1972M ANd
pretreatment
Not all feed water sources are equal!
Pretreatment is sometimes necessary to maximize the effectiveness of
water purification systems. Poor water quality can also shorten the life of
water system consumables.
Mixed Multi Water Softener
e ideal system to treat hard feed water
e Not only softens the water, but also protects the RO
membrane from blockage
e Removes calcium, magnesium, iron, and manganese and
a great variety of suspended matter and organic material
e Combination of multiple stages, from porous polymeric
adsorbers to ion exchangers
e Necessary for feed water with a silt density index (SDI)
that is greater than 3 or the total ionized solids (TIS) is
greater than 250 ppm
Single Pretreatment Cartridge
e Easy-to-use pretreatment cartridge protects the RO
membrane in a system against particles
e Ships with 10-inch filter housing and a 1 um filter
e ideal when feed water Silt Density Index (SDI) is 2-3
Double Pretreatment System
e Ships with two 10-inch filter housings, a combi-cartridge
which contains a 5 um filter and activated carbon, and a
hardness stabilizer cartridge
e Removes chlorine, organics, and hard ions
Triple Pretreatment System
e Ships with three 10 inch filter housings a combi-cartridge
which contains a 5 um filter and activated carbon, and a
hardness stabilizer cartridge, and a 1 um filter
e An effective triple pretreatment system removes chlorine,
organics, hard ions, and particles larger than 1 um
www.thermoscientific.com/purewater
Mixed Multi
Water Softener
Double Pretreatment System
Not sure what you need?
Request a complimentary Thermo Scientific
H20 Select analysis kit and let us analyze
your feed water. Your report will include a
recommendation of any pretreatment system
needed for your water purification system.
Thermc
RO Water
Deionized or
Distilled Water
Tap Water
Tap Water
Hard Tap Water
88
Barnsteac
lentifi
selector guide
Use pretreatment when your feed water quality doesn't match the requirements for your system.
DI 1500 cartridge
Required only when feed water does not meet feed water
requirements. Prolongs system cartridge life. For new
installations, 04.1690 is a required hose kit to adapt
cartridge to system.
Deionized and distilled water will meet the feed water requirements for the Thermo Scientific GenPure and MicroPure families.
No pretreatment is typcially required.
Pacific TII and reservoir or LabTower TII
Utilize a Type 2 system to pretreat the GenPure and MicroPure families
Pretreatment Filter, 1 um filter
Mix Multi Mini Water softener 120V,
The softener is required for most customers who have unsoftened 50/60Hz
tap water, or a TIS of more than 10ppm. Additionally, you will need to
replace the hardness stabilizer cartridge that ships with the unit with a 230V,
5 um filter with activated carbon. 50Hz
Pretreatment Filter, 1 pm filter
Ships with one 10 inch filter housing
It is ideal to place largest pore filter before smaller, so put the 5 um filter
with hardness stabilizer (ships with the unit) before the 1pm filter for optimal
performance. Designed for customers without chlorine in their tap water —
typically Europe and Asia Pacific
Pretreatment Filter with carbon
5 ym filter with activated carbon, 1 pm filter
Ships with two 10 inch filter housings
Designed for customers with chlorine in their tap water — typically
North America, Latin America and UK
Single Pretreatment System
5 um filter with hardness stabilizer cartridge
Ships with two 10 inch filter housings
Great option for customers with little/no chlorine in their tap water —
typically Europe and Asia Pacific
Double Pretreatment System
5 um filter with activated carbon cartridge,
hardness stabilizer cartridge
Ships with two 10 inch filter housings
Designed for customers with chlorine in their tap water — typically
North America, Latin America and UK
Triple Pretreatment System
5 um filter with activated carbon cartridge,
hardness stabilizer cartridge, 11m filter
Ships with two 10 inch filter housings
Mix Multi Mini Water softener 120V,
The softener will remove hardness and protect the RO membrane. 50/60Hz
Additionally, you will need to add a 5 um filter with activated carbon
and a 1 um filter. 230V,
Ships with two 10 inch filter housings 50Hz
Mix Multi Mini Water softener Uni
The softener will remove hardness to protect the RO membrane. £
Additionally, you will need to replace the hardness stabilizer cartridge
that ships with the unit with a 5 um filter with activated carbon. oe!
oOretrec
Stainless steel cartridge >
10 inch 1 um filter with housing >
Mixed multi softener >
5 um filter with activated carbon >
Mixed multi softener >
5 um filter with activated carbon >
10 inch 1 um filter with housing >
5 um filter with carbon >
10 inch 1 um filter with housing >
5 um filter with hardness stabilizer >
5 um filter with carbon and a
hardness stabilizer cartridge >
5 um filter with carbon and a
hardness stabilizer cartridge >
1um filter >
Mixed multi softener >
5 um filter with activated carbon >
1um filter >
Mixed multi softener >
5 um filter with activated carbon >
1um filter >
Mixed multi softener >
5 um filter with activated carbon >
Mixed multi softener >
5 um filter with activated carbon >
men
02.1500
see pages 56-63
09.4003
90129892
06.5201
90130297
06.5201
09.4003
90134022
09.4003
09.4001
09.4000
09.4000
09.4003
90129892
90134022
09.4003
90130297
90134022
09.4003
90129892
06.5201
90130297
06.5201
J J
Ships with 5um filter with hardness stabilizer thermoscientific.com/purewater 89
v w = f :
. ' = — æ < f — = %, a ee
à > lis 3 _— +» > we
= a d = MW r m i
-" ai ) > —, = k he. 7 Ca e : ps
€ ae — tee =. = 2
` — —— 4 et
k
k v ki eal |
i, s
&
pretreatment selecior guide —_—
(continued)
Replacement Consumables
Pretreatment
Model Number(s)
Component
Model Numbers
Pretreatment Description Component Description(s)
Single Pretreatment Cartridge 10 in (25.4 cm) 5 um filter and hardness stabilizer 06.5204
Single Pretreatment System 10 in (25.4 cm) 1 um filter 06.5101
| omw 10 in (25.4 cm) Activated carbon cartridge with 5 um filter 06.5201
Double Pretreament System 09.4000
10 in (25.4 cm) Hardness stabilizing cartridge 06.5452
10 in (25.4 cm) 5 um filter with activated carbon cartridge 06.5201
Triple Pretreatment System mate 10 in (25.4 cm) Hardness stabilizing cartridge 06.5452
10 in (25.4 cm) 1 um filter 06.5101
Wix Multi Mini, 2300, 50Hz 50130297 061000
Mix Multi Mini, 120V, 50/60Hz 50129892 50134335
Mix Multi Mini, 230V, 50Hz
Max flow rate, L/h 500
Filter volume, L 5
Capacity, m? at 10 °dH 2
Salt storage, kg 20
Operating pressure, psi (bar) 20-87 (1.4-6)
Water temperature max, °C 40
Controller time controlled
Dimensions, W x D x H, in (mm) 9 x 17.7 x 22 (230 x 450 x 560)
Model number 90130297
What is SDI? e SDI is a measure of the fouling capacity of water in RO systems
SDI stands for silt e The test measures the rate at which a 0.45 um filter is plugged
density index (SDI). when subjected to a constant water pressure of 30 psi
When the SDI of feed
e SDI gives the percent drop per minute in the flow rate of the
water through the filter, averaged over a period of time such as
15 minutes
water is >3, it can quickly
ruin your RO membrane
www.thermoscientific.com/purewater 91
92
cartridges
and filter systems
We offer a complete line of cartridge and filter systems
for all your single step purification and pretreatment
needs. Use the Thermo Scientific Bantam Deionizer,
Hose Nipple Cartridges or B-Pure cartridges for simple,
single- step purifications.
Innovation
Joints and seams are ultrasonically
welded to prevent contamination from
chemical adhesives
convenience
Quick-release designs provide
easy cartridge change-outs and
simplify maintenance, bypassing
the costs of service calls
flexibility
Versatile configurations meet
an array of specific applications
tific.com/purewater
you're purifying
Are the water systems »
under pressure?
Thermo Scientific Barnstead
cartridge & filter
selector guide
Choose the
feature you need Technology / Feature
~~ > @
Digital Purity Indicator
Pura-Lite “Go/No Go” /
Purity Indicators Analogue Resistivity Indicator
Color Change — Cartridge
Remote Dispenser
Wall Mounted
Added Features
Quick Release Canisters
Maximum Flow Rate L/min
94
Benefits
~~ @&
Digital purity indicator features real-time readout of
resistivity values; useful with more sensitive applications
Quick glance monitoring to notify user when it’s time
to install a new cartridge. Useful if cartridge system
feeds a piece of lab equipment, such as an autoclave,
where real time resistivity is not required.
Color change indicates when the cartridge is
beyond its useful life and must be replaced.
Useful for general lab applications.
Hand dispense water from the cartridge system.
Ideal for rinsing glassware or filling a waterbath.
saves laboratory bench space. Ideal configuration for
autoclaves and dishwashers where no bench space exists.
Allows for fast and simple cartridge change-outs.
m
Economical Filter
Holder
B-pure B-pure B-Pure
Double Holder Single Holder Half Size Holder sale Uli
Hose Nipple Bantam Deionizer
Smaller
capacity for
optimal value
Expanded
purification
with full features
Complete system Economical Simple system for Complete
with dispenser choice for nonpressurized nonpressurized
and cartridge particle filtration applications system
Single step
purification
Requires
/ J S vA hard piping to vA J
support unit
J "4 J J
4 4 2 4 2 0.75 0.63
www.thermoscientific.com/purewater 95
Thermo Scientific Barnstead B-Pure
water system
The Barnstead B-Pure is an economical laboratory grade water system with flow rates up to 4 L/min
that can be customized to meet your specific applications. Choose from single or double holders
depending on your application needs.
e Customize your water system to meet your application needs. Modular design
provides the ability to add additional holders when the need arises
e Produces up to four L/min
e Quarter turn quick release canisters make changing cartridges simple
e Accepts Thermo Scientific Barnstead Pura-Lite purity indicator or digital purity
meter to monitor water quality
e Available in full or half-size cartridge configurations supporting space
constraints
Single holder
e Produces up to four L/min
e Simple system without a draw-off valve or purity indicator
Double holder
e Produces up to four L/min
e Complete with draw-off valve
e Choose from models with digital purity meter or
Pura-Lite™ “Go/No Go” resistivity indicator
Half-size holder
e Produces up to 2 L/min
e Easily attaches to full size B-Pure systems
e Small size allows for flexibility in mounting location
e Pretreatment
e Deionization
e Organic and chlorine removal
e Feeding laboratory equipment
Quick Look Comparison
Resistivity reading Flow rate
Up to 4 L/min
1-10 MQ.cm (depending on cartridges used)
SADCdIaLYVO
8 NI aaie TC a
pretreatment or deionization needs
4
Harvey DI+ Cartridge System
mii
=
(q2)
T
Sp)
WM
<
O)
mF
(g2)
3
Sp)
e Turn-key system ships complete with a remote dispenser,
Pura-Lite (50 KQ-cm) indicator and a high capacity, two-bed
ion exchange cartridge to remove calcium, magnesium, and
other ions from water
e The Harvey DI+ system accepts a broad range of other
cartridges to remove impurities and produces pure water at
a flow rate of 4 L/min
Product Specifications
Overall dimensions Inlet Feed water Max feed Max flow
WxHxD connection temperature water pressure rate
i 7x24x7 in 7 A ,
Single holder (17.8 x 61 x 17.8 cm) 1/2 in NPTF 4-49°C (40-120°F) 100 psig 4 L/min
15x27x7 in oC 2 : : =
Double holder (38.1 x 68.65 x 17.8 cm) 1/2 in NPTF 4-49°C (40-120°F) 100 psig 4 L/min
Half size holder 7X15 x7 in 1/2 in NPTF 4-49°C (40-120°F) 100 psig 2 L/min
(17.8 x 38.1 x 17.8 cm)
7X 26Xx7 in - 3
Harvey Di+ ee 17.8 cm) 1/2 NPTF 4-49°C (40-120°F) 100 psig 4 L/min
Fe
ific.com/purewe J a” F 97
—
Thermo Scientific Barnstead B-Pure (continued)
Cartridges
Size Dimensions Length x Diameter
Full Size Cartridge 17.5 x 3.4 in
Half Size Cartridge 10.95 x 3.4 in
System Options Electrical
Double holder with digital purity meter
Double holder with Pura-Lite indicator (50 K0)
Double holder with Pura-Lite indicator (200 kQ)
Double holder with Pura-Lite indicator (1 MO)
Half size holder =i
98
Model number
D4511
D4521
D4522-33*
D4524
D5831
D5833
D4505
AY1273X4
'@ CE
Required Accessories
Choose the cartridge(s) according to your needs.
Anion removal
Effective removal of weakly ionized impurities, raises the pH of solutions,
recovers precious metal complex
Cation removal
Converts ionized salts to the acid form resulting in a product water that is
low in pH, ideal for precious metal or isotope recovery
High capacity
Removes ionized impurities, produces a larger quantity of water than that
of the Ultrapure (D0809), however at a lower resistivity
Pretreatment macropure
Effectively removes colloids and bacteria, increases filter life
Organic removal
Removes organics and chlorine.
Organic removal
Removes organics and chlorine. Ideal for pretreating water systems with high
organic levels in the feed water.
Oxygen removal
Maintains low oxygen content to prevent corrosion in cooling water loops, etc.
The feed water should contain less than 10 ppm of ionized solids.
Oxygen and demineralization
Ultrapure
Removes ionized impurities to produce high resistivity water with a neutral pH
Ultrapure and organic removal
Commonly used as still pretreatment. Removes ionized impurities and has a
layer of activated carbon to remove chlorine and organics.
Ultrapure and oxygen removal
Ultrapure, oxygen, and organic removal
Optional Accessories
Digital Purity Monitor — Resistivity range of 0.1-18.2 MQ.cm
Indicator light at 50,000 O.cm
Pura-Lite Indicator light at 200,000 ©.cm
Indicator light at 1,000,000 Q.cm
1 to 75 L/hr using 1/8 inch NPT inlet
Flow meters
0 to 190 L/hr using 1/8 inch NPT inlet
0.2 ym final filter — For use on Double Holder units
Resin type(s)
Strong anion exchange
Strong cation exchange
Two-bed ion exchange
Macroreticular,
activated carbon
Activated carbon
Extruded carbon
Porous strong
anion exchange
Cartridge
size
Full
Full
Full
Full
Half
Half
Oxygen removal
mixed-bed
Mixed-bed
Mixed-bed,
activated carbon
Ultrapure, oxygen removal
Ultrapure, oxygen and
organic removal
www.thermoscientific.com/purewater
Half
Full
Half
Full
Full
Capacity as CaCO,
1680 grains
3170 grains D0815
1760 grains D0803
2000 gal D0836
5000 gal D0813
5000 gal D50215
5000 gal D63112
18g D50214
275 grains / 9 g D50216
875 grains D0809
550 grains D50213
785 grains / 1000 gal D0832
275 grains / 2000 gal D50217
455 grains / 30 g D8809
365 grains / 2000 gal / 12 g D8811
Voltage
—
NO
(=æ)}
99
sJ9adld Lavo
TI
==
(qp)
a, *
(op)
Sp)
<=
Sp)
r=
(qp)
5
(op)
Thermo Scientific Bantam Deionizer
The Bantam Deionizer is an economical way to deionize your water. Easily view resistivity readings directly from unit.
Customizable to specific applications by selecting the appropriate cartridge listed below.
a =
h 4 Øg
e ideal for applications requiring up to 38 L/hr of purified water
e Select the cartridge to best meet your application needs
e Point of use polishing of pretreated water or single stage treatment of tap water
e Direct reading purity monitor
e Designed for non-pressurized applications. Output water must be diverted to an
atmospherically-vented receptacle, no back pressure can be accepted
e Minimum inlet pressure 5 psi, maximum inlet pressure 70 psi
e Includes 3 ft (0.9 m) of inlet feed tubing
Quick Look Comparison
Resistivity reading Flow rate
20,000-18,000,000 ©-cm Up to 38 L/hr
system Options
Overall dimensions Feed water : Model
WxHxD pressure Aada number
Bantam 6 x 28.5 x 8.75 in ne 120 VAC D0800
Deionizer* | (15.2 x 72.4 x 22.2 cm) p a E
Required Accessories
Choose the cartridge based on Resin Model
e Pretreatment
your application needs. Type(s) Capacity Number
e Deionization
High capacity
Removes ionized impurities, produces a larger
quantity of water than that of the Ultrapure (D0809),
however at a lower resistivity
Ultrapure
Removes ionized impurities to produce highest Mixed-Bed | 875 grains D0809
resistivity water with a neutral pH
Ultrapure and organic removal (pretreatment) Mixed-Bed
Commonly used as still pretreatment. Removes i ’ | 785 grains /
ae ae i Activated D0832
ionized impurities and has a layer of activated carbon Caon 1000 gal
to remove chlorine and organics
e Organic and chlorine removal
Two-Bed lon
Exchange
1760 grains D0803
'@ CE
Thermo Scientific Barnstead Hose Nipple Cartridges
The Barnstead Hose Nipple Cartridges are an economical way to purify water volumes up to 75 L/hr
Applications include softening, deionization, organic and chlorine removal.
sJa9adld Lavo
e Economical purification option
e ideal for small volume applications
e Same superior quality resins used in B-Pure cartridges
e Constructed of 100% virgin polypropylene cartridge
e Designed for non-pressure applications, these cartridges include 3/8 inch barb
hose connections on each end. D8822, D8950, and D8951 cartridges include
tapered straight nipple for 3/8 inch ID tubing
e Color change indicator identifies when resin is exhausted in specific cartridges
e Simple cartridge holder is easily wall mounted
TI
—
(qp)
m
(oe)
(Fp)
<
(oe)
rF
(qp)
=
(oe)
Product Specifications
1/2 Size 10.2 x 3.25 in (25.9 x 8.25 cm)
2/3 Size 13.3 x 3.25 in (33.8 x 8.25 cm)
Full Size 18.7 x 3.25 in (47.5 x 8.25 cm)
Hose nipple cartridge holder
, D8900
For easy wall mounting
Required Accessories
1/2 size mixed-bed Ultrapure ion exchange 430 grains | No D50220
Deionization 1/2 size mixed-bed Ultrapure mixed-bed 280 grains / D8822
Organic and chlorine removal with oxygen removal with strong anion exchange 4.4g
. . a ; Two-bed ion exchange :
Feeding laboratory equipment 2/3 size high capacity A Sane A SEE 1100 grains D8950
2/3 size mixed-bed and Mixed-bed ion exchange | 470 grains / Ves D8951
organic removal with activated carbon 2000 gal
Full size cation removal Cation exchange 3000 grains D8905
Full size high capacity Two-bed ion exchange 1650 grains D8901
Full size macroreticular, Macroreticular cation
Full size organic removal Activated carbon 5000 gal | No D8904
Full size oxygen removal Strong anion exchange | wg | No D8903
Full size pretreatment Mixed-bed and strong cation |1250 grains / Nes D8921
and scale eliminator exchange, activated charcoal | 1000 gal
Full size ultrapure Ultrapure ion exchange 915 grains | No | D8911
: Ultrapure mixed-bed ion
s Full size ultrapure 915 grains D8902
Full size ultrapure with Mixed-bed ion exchange | 730 grains / Yes D8922
g organic removal with activated carbon 2000 gal
1 Alcohol-containing samples can not be used in cartridges containing the color indicator
d ' www.thermoscientific.com/purewater 101
Thermo Scientific Barnstead 1/2 Size B-Pure Filter
Barnstead 1/2 Size B-Pure Filters will meet all your prefiltration needs.
The filters can be used to pretreat feed water or act as a final filter to ensure consistently pure water.
Product features
e Large surface area ensures long life
e Flow rates of up to two L/min
Choose from two holder options:
1/2 Size B-Pure Filter Holder
e Natural polypropylene material construction maintains purity
e Filters are easily and quickly replaced with quarter turn quick release canisters
e Accepts 10 inch (25.43 cm) pre- and post-filters
e Wall mounting bracket comes standard
Economy Filter Holder
e Accepts 10 inch (25.43 cm) double open-ended filters
e Can be piped into any water line
Optional accessory
Pressure Gauge Kit
e Attaches to any B-Pure system
e ( to 160 psi pressure gauge allows for monitoring inlet and outlet water
pressure
e Monitors pressure drop across any of the 10 inch (25.43 cm) filter cartridges
used in the 1/2 Size B-Pure Filter Holder
e Pressure drop of greater than 10 psi indicates need for filter change
e Particulate and bacteria removal
(En a
i n
IFA T
Economy Filter Holder
102
axible
filtration system
system Options Product Specifications
Overall dimensions Inlet Feed water Max feed Max flow
WxHxD connection temperature water pressure rate
7X15x7in : —
(17.8 x 38.1 x 17.8 cm) 1/2 in NPTF 4-49°C (40-120°F)
5.25 x 12 x 5.25 in , S Aan ;
(13.3 x 30.5 x 13.3 cm) 3/4 in NPTF 4-49°C (40-120°F)
1/2 Size B-Pure holder* 100 psi
Wall mount included psi
Economy filter holder* 100 psig
Required Accessory
1/2 size B-Pure Economy
Filter Holder Holder
FL583X4 18024
Pore Size Length in (cm) Diameter in (cm)
zi
according to 15 um Pre-filter 10 (25.4 FL583X3 18018
your needs
0.2 um Final Filter 10 (25.4 FL583X6 —
0.45 um Final Filter 10 (25.4
Optional Accessories
FL583X5 =
Dual pressure gauge kit D2780 —
Single pressure gauge D0780 -=
103
SADCdIeGLYVO
att
=
(q2)
A
O)
WM
<
O)
mF
(g)
=
Sp)
Cleaning your purification
system allows bacterial
contaminants to be
flushed away.
Changing the UV lamp protects the system
against microorganisms and oxidizes
organic compounds in the feed water,
allowing for TOC levels of less than 5ppb.
Thermo Scientific Barnstead NanoPure System Consumables
Standard unit D11901 D11911 D11921 D11931
+ TOC monitor D11941 D11951 D11961 D11971
Replacement Consumables
Diamond cartridge pack ||| | Deionized feed D50283 D50281 D50283 D50281
Choose the cartridge pack according
to your feed water and system.
Ships with 0.2 um final filter (03750) D50280
Ultraviolet lamp (system) LMX13
Ultraviolet lamp (TOC) LMX26
104
Thermo Scientific Barnstead EasyPure II System Consumables
EasyPure
TE
Replacement Consumables
Cartridge pack
to your feed water and system
0.2 um final filter D3750
Ultraviolet lamp
Ultrafilter
Cleaning syringe CMX25
Thermo Scientific Barnstead EasyPure RF System Consumables
= EasyPure EasyPure
ih oy RF UV
Pom D7031 D7035
Replacement Consumables
Cartridge pack D502124
Choose the cartridge pack
according to your RO or
feed water and system distilled feed D502125
0.2 um final filter D3750
Ultraviolet lamp n/a LMX13
Ventgard™ reservoir cap CV703X4A
Set of three empty cartridges for cleaning D7034
Thermo Scientific Barnstead TII System Consumables
Barnstead TII
TII 12 L/h D14031
Til 24 L/h D14041
Replacement Consumables
ae a oa filter (03750) D90213
1 pm pre-filter D502113
MPS cartridge D502114
Extruded carbon cartridge D502115
0.2 um final filter D3750
Reverse osmosis membrane FL1265X1
Ultraviolet lamp (system) LMX13
Ultraviolet lamp (reservoir) LMX31
Ventgard reservoir cap 25001-DB
ll
ie D7381
E
D3750 D3750
n/a n/a LMX13
CMX25 CMX25
EasyPure EasyPure
Il UV/UF
EasyPure
ll UV U
F
D7401 D7411 D8611
Deionized feed D502126 D502124 D502126
Choose the cartridge pack according
D502124
D502125
FL1192X1 FL1192X1
Thermo Scientific Barnstead EasyPure RoDi System Consumables
=
EasyPure RoDi
D13321
Replacement Consumables
Cartridge kit
Includes pre-filter, ultrapure mixed bed cartridge, and D502133
EasyPure high purity/low TOC cartridge
0.2 um final filter D3750
Ultraviolet lamp LMX13
Ventgard™ reservoir cap CV742X5A
Reverse osmosis membrane FL1332X2
Set of three empty cartridges for cleaning D7034
Thermo Scientific Barnstead RO System Consumables
Barnstead RO
RO 6 L/h D12671
RO 12 L/h D12651
RO 24 L/h D12661
Replacement Consumables
Reverse 6 and 12 L/h FL1265X1
osmosis
membrane 24 L/h FL1265X1
Requires 2 RO membranes
(please order 2)
1 pm pre-filter D502113
MPS cartridge D502114
Extruded carbon cartridge D502115
Ventgard reservoir cap CV742X5A
www.thermoscientific.com/purewater 105
=
m
Q)
>
©
<
O
O
Z
N)
C
S
>
UJ
m
m
Yn
support and maintenance
Contact the Lab Water Experts
Have a question or concern, contact our PURE Water Experts!
Technical Questions
Our technical service team is ready
to answer any of your questions on
your existing systems.
106
Customer Service
Let our professional and experienced
customer service representatives guide
you when choosing your water system.
They will evaluate your needs, develop
a system recommendation and
coordinate the installation of your
water system.
New Lab Construction
We offer the most comprehensive line
of water purification systems in the
world. We can design a water system
to meet your new lab’s needs.
Services
Maintaining your water purification system is crucial to the overall productivity of your laboratory, the long-term
performance of the system and the total cost of ownership. We offer a variety of services to suit your individual
needs. Professional service delivers improved productivity, convenience, peace-of-mind and budget control.
Preventive maintenance Installation
To ensure your system is working Our factory-trained technicians can
within specifications, regular install your system to ensure it operates
maintenance is essential. We offer with precision. With our services, you
various service options and preventative will receive:
maintenance, which will extend the
working life, protect your system and e Installation scheduled at your
prevent costly breakdown. convenience
e Assurance that all technical
specifications are met
e Practical hands-on instructions
Validation
We offer validation services according
to cCGMP/GLP regulations, certifying
that your system is performing to
pre-determined technical specifications.
Our validation services provide you with:
e Factory-trained experts —
experienced in cCGMP/GLP
environments and
Good Document Practice
e 10/00 factory-developed validation
protocols
Please ask your local sales representative for additional information about service offerings in your area.
www.thermoscientific.com/purewater
107
108
Go Green
Smart Green designs mean a great water system for you
and a smaller impact on the environment!
Our engineers created water systems with the environment in mind:
Reduce
Our cartridges use high quality resin to extend the useful life of the cartridge. Extended
life reduces the need to replace your cartridges which, in turn, reduces the waste
stream and improves your laboratory’s sustainability. You'll use your cartridges longer,
reducing the need to reorder, ship, handle and dispose of your cartridges.
Our units are designed to minimize the amount of water that is used during the analysis.
To provide the customer with pure water and low power consumption, our units go into
a low energy mode after dispensing without sacrificing water quality for your applications.
Reuse
Our cartridges were engineered with the environment in mind. The plastic cartridge
casings and endcaps are constructed using virgin polypropylene to allow for easy
recycling after end of life. The cartridge is assembled in a clean environment using
environmentally friendly ultrasonic welding that minimizes energy usage compared to
other joining as well as avoids the use of any environmentally unfriendly solvents. Our
conscious effort to avoid chemical solvents and adhesives makes the plastic and resin
suitable to be recovered, reground and reused for a variety of alternate uses.
Common Conversions
Common Conversions for Pure Water
1 U.S. Gallon (gal) = 231 Cubic in (in?) = 3.785 Liters (L)
Volume -1 Cubic Meter (m?) = 35.3 Cubic Feet (ft.3)
1 U.S. Ounce (0z) = 29.57 Milliliters (mL)
1 U.S. Gallon (gal) = 8.33 Ib. Water
1 Cubic Foot (ft.3) = 62.3 Ib. Water
°F = (°C x 9/5) + 32
Temperature K =°C + 273
°F = (K - 273.15) * 9/5 + 32
1 Ib = 453.6 grams (g) = 7000 grains (gr.)
1 kg = 2.205 Ib.
1 Atmosphere = 14.7 Pounds Per Square Inch (psi) = 101.325 Kilo Pascal (KPa)
psia (absolute) = psig (gauge) + 14.7
Pressure 9.92 in Hg = 33.83 ft. HO
1 kg/cm? = 14.233 psi
1 KPa = 0.145 psi
1 Grain Per Gallon (gr/gal) = 17.1 Parts Per Million (ppm)
”
Cc
U
U
O
JJ
—
>
=
g
=
>
=
mr
m
=
>
Z
©
m
Density
Mass
1 Grain Per Gallon as NaCl = 0.85 Grains Per Gallon as CaCO,
1 Part Per Million (ppm) = 1 Milligram Per Liter (mg/L)
Total ionized
solids concentration 1 ppm as NaCl = 0.85 ppm as CaCO;
1 ppm = 1,000 Parts Per Billion (ppb) = 1,000,000 Parts Per Trillion (ppt)
1 ppb = 1 Microgram Per Liter (ug/L)
1 ppm = 1.5 uS/cm
Resistivity/Conductivity 1 megohm-cm = 1/(uS/cm) = 1/( umho/cm)
Calculating lon Exchange Capacity
Cartridge Grain Capacity / Total Dissolved Solids (Grains/Gal) = Gallons Processed
Cartridge Grain Capacity x 17.1 / Total Dissolved Solids (ppm) = Gallons Processed
Cartridge Grain Capacity x 64.7 / Total Dissolved Solids (ppm) = Liters Processed
www.thermoscientific.com/purewater 109
Absorption — Process by which one substance is taken up by
another, either chemically or physically, as when a sponge
“soaks up” a liquid.
Activated Carbon — Material used to adsorb organic
impurities from water.
Anion Exchange Resin — An ion exchange material that
removes anions from solution by exchanging them with
hydroxyl ions.
Bed — Column of carbon, sand or ion exchange resins through
which the water passes during treatment.
Cation Exchange Resin — lon exchange resins capable of
removing cations by exchanging them for hydrogen ions.
Conductivity — The reciprocal of resistivity, it is a measure
of the ability to conduct an electric current. Since ionized
impurities increase the conductivity of water, it is also an
accurate measure of ionic purity. To measure it, current is
passed between two electrodes a fixed distance apart.
Conductivity is normally expressed as microsiemens/cm,
identical to micromhos/cm.
Deionization — Removing dissolved ions from solution by
passing it through a bed of ion exchange resins, consisting of
polymer beads that exchange hydrogen ions for cations and
hydroxyl ions for anions in solution. The ionic impurities
remain bound to the resins, and the hydrogen and hydroxyl
ions combine with each other to form water.
Dissolved Solids — Also referred to as Total Dissolved Solids
(TDS), it is the amount of nonvolatile matter dissolved in a
water sample and is usually expressed in parts-per-million by
weight.
Distillation — The process of separating water from
impurities by heating until it changes into vapor and then
cooling the vapor to condense it into purified water.
Electrodeionization (EDI)— Removes dissolved ions from
solution using electricity to ionize water and separate ions.
Effluent — The output or discharge from a water treatment
genem
=_= glossary = — = —
Process.
Endotoxin — A poisonous substance present in bacteria that
is released when the cell disintegrates. In water treatment, it
most often refers to pyrogens.
Exhaustion — When absorbents, such as activated carbon or
ion exchange resins, have depleted their capacity by using up
all active sites. lon exchange resins may be regenerated to
reverse the process.
Feed Water — Water entering a treatment process.
Filtration — Removal of suspended matter by passing it
through a porous matrix that prevents particles from getting
through, usually by entrapment on or in the filter matrix.
Fouling — When gelatinous coatings, colloidal masses or
dense bacterial growth form a compacted crust on membrane
or filter surfaces which blocks further flow.
Grains per Gallon — Concentration of dissolved ions in water,
generally as calcium carbonate. 7,000 grains is equal to a
pound. One grain per gallon is equivalent to 17.1 ppm of
Dissolved Solids.
Hardness — Concentration of calcium and magnesium salts
in water and is sometimes also taken to include iron and
manganese. High hardness can cause boiler or pipe scale
and failure of reverse osmosis membranes.
lon Exchange — Also called deionization. A process in which
harmless ions attached to the resin beads are exchanged for
undesirable ions in solution. Typically, hydrogen ions are
exchanged for any cations and hydroxyl ions for any anions.
The hydrogen and hydroxyl ions combine to form pure water.
Macroreticular Resin — An ion exchange resin with a
reticular porous matrix that makes it effective for removing
colloids and bacteria, as well as dissolved anions. It is
especially useful for preventing colloidal and organic fouling
of mixed-bed resins and premature clogging of final filters.
Megohm-cm — © A measure of ionic purity in water.
Resistivity (the reciprocal of conductivity) is a measure of
specific resistance to electrical flow. The fewer dissolved ions
in water the higher its resistivity. One megohm-cm is
equivalent to one million ohms of resistance measured
between two electrodes one centimeter apart. The theoretical
maximum ionic purity for water is 18.2 megohm-cm at 25°C .
Membrane -— Filtration membranes are thin polymer films
that are permeable to water and other fluids. Microporous
membrane filters have measurable pore structures which
physically remove particles or microorganisms larger than
pore size. Ultrafiltration membranes (sometimes called
molecular sieves), also remove molecules larger than a
specified molecular weight. Reverse osmosis membranes are
permeable to water molecules and very little else, rejecting
even dissolved ions in water.
Mho — Unit of measurement for conductance; the reciprocal
of ohm (resistance). See Megohm-cm.
Mixed-Bed lon Exchange — Mixing both anion and cation
resins in the same deionizer results in higher efficiency, but
lower capacity than separate-bed deionizers.
NPT — Abbreviation for National Pipe Thread.
Ohm — The practical unit of electrical resistance in a circuit,
where a potential difference of one volt produces a current of
one ampere.
Ohm-cm — Unit of specific resistance of water.
Osmosis — The diffusion of a solvent through a
semipermeable membrane from a less concentrated solution
to a more concentrated solution.
Percent Recovery — In reverse osmosis or ultrafiltration, the
ratio of pure water output to feed water input.
Percent Rejection — In reverse osmosis or ultrafiltration, the
ratio of impurities removed to total impurities in the incoming
feed water. For example, RO membranes typically remove
(reject) 90% of the dissolved inorganic contaminants in water.
Permeate — In reverse osmosis, the water that diffuses
through the membrane, thereby becoming purified water.
Pretreatment — Initial water treatment steps performed prior
to final processing to prolong the life of cartridges and filters
and to protect downstream elements from premature failure.
Product Water — The purified water produced as a result of
treatment.
Pyrogens — Lipopolysaccharides found in the outer cell walls
of certain bacteria which can trigger an immune response.
Recirculation — Continuous recirculation may be necessary
to maintain uniformly high purity in larger water systems.
Water is continuously recirculated and reprocessed to prevent
stagnation and to rinse out residual impurities in the system.
Bacteria flourish in stagnant water.
Reject — In reverse osmosis and ultrafiltration, those
impurities not able to permeate the membrane are said to be
rejected (removed). They are flushed away in the reject
(waste) stream.
Resin — lon exchange resins are usually bead-like spherical
materials with an affinity for particular ions. Cation exchange
resins, made of styrene and divinylbenzene containing
sulfonic acid groups, will exchange hydrogen ions for any
cations they encounter. Similarly, anion exchange resins,
made of styrene and divinyloenzene containing quaternary
ammonium groups, will exchange a hydroxyl ion for any
anions.
Resistivity — A measure of specific resistance to the flow of
electricity. In water, it is an accurate measure of ionic purity.
See Megohm-cm.
Reverse Osmosis — The reversal of osmosis to purify water.
In osmosis, water diffuses through a semipermeable
membrane from a less concentrated solution to a more
concentrated solution. The flow of water can be reversed with
an opposing pressure that exceeds osmotic pressure. With
Reverse Osmosis, water is forced out of a concentrated
solution, leaving the solute (impurities) behind.
www.thermoscientific.com/purewater 111
Q)
r
O
N
U)
>
JJ
=<
Salt Rejection — In reverse osmosis, the ratio of salts
removed (rejected) to the original salt concentration. See
Percent Rejection.
Scale — The mineral deposits that can coat the insides of
boilers or the surfaces of RO membranes. It consists mainly of
calcium carbonate, which precipitates out of solution under
certain conditions of pH, alkalinity and hardness.
Semipermeable — Membranes that do not have measurable
pores, but through which smaller molecules can pass.
Suspended Solids — Undissolved solids that can be removed
by filtration.
TDS — Abbreviation for total dissolved solids.
Total lonized Solids — Concentration of dissolved ions in
solution, expressed in concentration units of NaCl (sodium
chloride).
Total Organic Carbon (TOC) — A measure of the level of
organic impurities in water, which determines the operating life
of activated carbon beds.
Total Solids — Total solids in water include both dissolved
and suspended solids.
Turbidity — A suspension of fine particles that obscures light
rays but requires many days for sedimentation because of
small particle size.
Two-Bed — Separate beds or layers of cation and anion
exchange resins. Results in lower purity than mixed-bed
deionization, but provides higher capacity in terms of
throughput.
Ultrafiltration — Molecular sieves; membranes with pores
small enough to remove large molecules. Rated in terms of
nominal molecular weight cutoff. A 10,000 Dalton (molecular
weight) UF membrane, for example, will remove bacterial
pyrogens, which are typically in the range of 20,000 Daltons.
= glossary = =
Ultrapure Water — Water with a specific resistance higher
than 1 megohm-cm. In the laboratory, it usually refers to
ASTM D1193 Type 1 reagent grade water. Anything in
laboratory water that is not H0 is an impurity. Although
chemically pure water is not attainable, ultrapure water
systems are now capable of reducing impurities down to the
limits of detection.
UV Oxidation — Ultraviolet radiation is employed in water
purification for the photochemical oxidation of organic
impurities, resulting in HPLC grade water with organic
impurity levels below 5 ppb.
www.thermoscientific.com/purewater
© 2013 Thermo Fisher Scientific Inc. All rights reserved. All (other) trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries.
CLSI-CLRW is a registered trademark of the Clinical and Laboratory Standards Institute. Teflon is a registered trademark of E.I. du Pont de Nemours and
Company. Specifications, terms and pricing are subject to change. Not all products are available in all countries.
Please consult your local sales representative for details.
Australia +61 39757 4300 India toll free 1800 22 8374 Russia +7 812 703 42 15
Austria +43 1 801 40 0 India +91 22 6716 2200 Spain/Portugal +34 93 223 09 18
Belgium +32 53 73 42 41 Italy +32 02 95059 552 Switzerland +41 44 454 12 22
China +800 810 5118 or Japan +81 3 5826 1616 UK/Ireland +44 870 609 9203
+400 650 5118 Netherlands +31 76 579 55 55 USA/Canada +1 866 984 3766
France +33 2 2803 2180 New Zealand +64 9 980 6700
Germany national toll free 08001-536 376 Nordic/Baltic/CIS countries Other Asian countries +852 2885 4613
Germany international +49 6184 90 6000 +358 9 329 10200 Countries not listed: +49 6184 90 6000
BRWPBOOK 0313
Thermo
SCIENTIFIC
Part of Thermo Fisher Scientific